{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,2]],"date-time":"2026-04-02T16:07:33Z","timestamp":1775146053256,"version":"3.50.1"},"reference-count":26,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2016,12,23]],"date-time":"2016-12-23T00:00:00Z","timestamp":1482451200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>An 8-electrode capacitance tomography (ECT) sensor was built and used to measure moisture content (MC) and mass flow of pine chip flows. The device was capable of directly measuring total water quantity in a sample but was sensitive to both dry matter and moisture, and therefore required a second measurement of mass flow to calculate MC. Two means of calculating the mass flow were used: the first being an impact sensor to measure total mass flow, and the second a volumetric approach based on measuring total area occupied by wood in images generated using the capacitance sensor\u2019s tomographic mode. Tests were made on 109 groups of wood chips ranging in moisture content from 14% to 120% (dry basis) and wet weight of 280 to 1100 g. Sixty groups were randomly selected as a calibration set, and the remaining were used for validation of the sensor\u2019s performance. For the combined capacitance\/force transducer system, root mean square errors of prediction (RMSEP) for wet mass flow and moisture content were 13.42% and 16.61%, respectively. RMSEP using the combined volumetric mass flow\/capacitance sensor for dry mass flow and moisture content were 22.89% and 24.16%, respectively. Either of the approaches was concluded to be feasible for prediction of moisture content in pine chip flows, but combining the impact and capacitance sensors was easier to implement. In situations where flows could not be impeded, however, the tomographic approach would likely be more useful.<\/jats:p>","DOI":"10.3390\/s17010020","type":"journal-article","created":{"date-parts":[[2016,12,23]],"date-time":"2016-12-23T04:09:09Z","timestamp":1482466149000},"page":"20","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Simultaneous Moisture Content and Mass Flow Measurements in Wood Chip Flows Using Coupled Dielectric and Impact Sensors"],"prefix":"10.3390","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2653-3836","authenticated-orcid":false,"given":"Pengmin","family":"Pan","sequence":"first","affiliation":[{"name":"Biosystems Engineering Department, Auburn University, 200 Corley Building, Auburn University, Auburn, AL 36849, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Timothy","family":"McDonald","sequence":"additional","affiliation":[{"name":"Biosystems Engineering Department, Auburn University, 200 Corley Building, Auburn University, Auburn, AL 36849, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John","family":"Fulton","sequence":"additional","affiliation":[{"name":"Department of Food, Agricultural and Biological Engineering, Ohio State University, 590 Woody Hayes Drive, Columbus, OH 43210-1057, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brian","family":"Via","sequence":"additional","affiliation":[{"name":"School of Forestry and Wildlife Sciences, Auburn University, 602 Duncan Drive, Auburn University, Auburn, AL 36849, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John","family":"Hung","sequence":"additional","affiliation":[{"name":"Electrical &amp; Computer Engineering Department, Auburn University, 200 Broun Hall, Auburn University, Auburn, AL 36849, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2016,12,23]]},"reference":[{"key":"ref_1","first-page":"52","article-title":"Long-term monitoring of timber moisture content below the fiber saturation point using wood resistance sensors","volume":"51","author":"Dai","year":"2001","journal-title":"For. Prod. J."},{"key":"ref_2","first-page":"28","article-title":"Experimental study of resistance type wood moisture sensors for monitoring wood drying process above fibre saturation point","volume":"59","author":"Tamme","year":"2013","journal-title":"For. Stud."},{"key":"ref_3","first-page":"85","article-title":"Relationship between stress wave velocities of green and dry veneer","volume":"54","author":"Brashaw","year":"2004","journal-title":"For. Prod. J."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1007\/s00226-010-0350-6","article-title":"Effects of moisture content and temperature on acoustic velocity and dynamic MOE of radiata pine sapwood boards","volume":"45","author":"Chan","year":"2011","journal-title":"Wood Sci. Technol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1007\/s10086-005-0724-9","article-title":"Predicting moisture content and density distribution of Scots pine by microwave scanning of sawn timber II: Evaluation of models generated on a pixel level","volume":"52","author":"Lundgren","year":"2006","journal-title":"J. Wood Sci."},{"key":"ref_6","first-page":"69","article-title":"Microwave moisture measurement system for lumber drying","volume":"57","author":"Moschler","year":"2007","journal-title":"For. Prod. J."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1139\/x04-160","article-title":"Nondestructive estimation of Pinus taeda L. wood properties for samples from a wide range of sites in Georgia","volume":"35","author":"Jones","year":"2005","journal-title":"Can. J. For. Res."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1007\/BF00767290","article-title":"Estimation of Pinus radiata D. Don clear wood properties by near-infrared spectroscopy","volume":"48","author":"Schimleck","year":"2002","journal-title":"J. Wood Sci."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"653","DOI":"10.1007\/s00226-009-0263-4","article-title":"Dielectric spectroscopy of Scots pine","volume":"43","author":"Tomppo","year":"2009","journal-title":"Wood Sci. Technol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"809","DOI":"10.1093\/treephys\/16.10.809","article-title":"Measuring stem water content in four deciduous hardwoods with a time-domain reflectometer","volume":"16","author":"Wullschleger","year":"1996","journal-title":"Tree Physiol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1016\/S1537-5110(03)00131-4","article-title":"A general dielectric model for time domain reflectometry","volume":"86","author":"Woodhead","year":"2003","journal-title":"Biosyst. Eng."},{"key":"ref_12","first-page":"27","article-title":"Detection of transverse moisture gradients in timber by measurements of capacitance using a multiple-electrode arrangement","volume":"50","author":"Jazayeri","year":"2000","journal-title":"For. Prod. J."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1177\/002029400904200306","article-title":"Applied research on moisture content measurement: One sided capacitance sensors","volume":"42","author":"Xinguang","year":"2009","journal-title":"Meas. Control"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"935","DOI":"10.1016\/j.biombioe.2006.06.005","article-title":"Moisture content determination in solid biofuels by dielectric and NIR reflection methods","volume":"30","author":"Jensen","year":"2006","journal-title":"Biomass Bioenergy"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1049\/el:19880283","article-title":"Capacitance-based tomographic flow imaging system","volume":"24","author":"Huang","year":"1988","journal-title":"Electron. Lett."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1007\/s10086-010-1106-5","article-title":"Improvement of simple impedance tomography method in RF range for estimating moisture distribution in squared timbers","volume":"56","author":"Sobue","year":"2010","journal-title":"J. Wood Sci."},{"key":"ref_17","first-page":"476","article-title":"Void fraction measurement in oil-gas transportation pipeline using an improved electrical capacitance tomography system","volume":"12","author":"Niu","year":"2004","journal-title":"Chin. J. Chem. Eng."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1088\/0957-0233\/19\/4\/045503","article-title":"Mass flow measurement of pneumatically conveyed solids using electrical capacitance tomography","volume":"19","author":"Sun","year":"2008","journal-title":"Meas. Sci. Technol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1088\/0957-0233\/8\/4\/010","article-title":"Velocity and mass flow rate profiles of dry powders in a gravity of drop conveyor using and electrodynamic tomography system","volume":"8","author":"Green","year":"1997","journal-title":"Meas. Sci. Technol."},{"key":"ref_20","first-page":"1","article-title":"Development of a variable density flow meter for an industrial application using tomographic imaging","volume":"14","author":"Young","year":"1996","journal-title":"IEE Colloq. Adv. Electr. Tomogr."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/j.flowmeasinst.2012.10.003","article-title":"Decoupling the joint effect of moisture and mass in dense phase pneumatic conveying","volume":"34","author":"Chen","year":"2013","journal-title":"Flow Meas. Instrum."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.biosystemseng.2015.12.005","article-title":"Predicting moisture content of chipped pine samples with a multi-electrode capacitance sensor","volume":"145","author":"Pan","year":"2016","journal-title":"Biosyst. Eng."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1016\/0168-1699(95)00049-6","article-title":"Comparison of sensors and techniques for crop yield mapping","volume":"14","author":"Birrell","year":"1996","journal-title":"Comput. Electron. Agric."},{"key":"ref_24","first-page":"89","article-title":"Electrical capacitance tomography for flow imaging: System model for development of image reconstruction algorithms and design of primary sensors","volume":"139","author":"Xie","year":"1992","journal-title":"Circuits Devices Syst."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1049\/ip-smt:19990008","article-title":"New AC-based capacitance tomography system","volume":"146","author":"Yang","year":"1999","journal-title":"IEE Proc. Sci. Meas. Technol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1049\/iet-smt:20060108","article-title":"Simulation design of electrical capacitance tomography sensors","volume":"1","author":"Olmos","year":"2007","journal-title":"IET Sci. Meas. Technol."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/1\/20\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T19:29:09Z","timestamp":1760210949000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/1\/20"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,12,23]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2017,1]]}},"alternative-id":["s17010020"],"URL":"https:\/\/doi.org\/10.3390\/s17010020","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,12,23]]}}}