{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,4]],"date-time":"2026-07-04T07:03:56Z","timestamp":1783148636436,"version":"3.54.6"},"reference-count":32,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2016,12,23]],"date-time":"2016-12-23T00:00:00Z","timestamp":1482451200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100000781","name":"European Research Council","doi-asserted-by":"publisher","award":["267351"],"award-info":[{"award-number":["267351"]}],"id":[{"id":"10.13039\/501100000781","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001711","name":"Schweizerischer Nationalfonds zur F\u00f6rderung der Wissenschaftlichen Forschung","doi-asserted-by":"publisher","award":["142440"],"award-info":[{"award-number":["142440"]}],"id":[{"id":"10.13039\/501100001711","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["8R21GM103467-03"],"award-info":[{"award-number":["8R21GM103467-03"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["RR025761"],"award-info":[{"award-number":["RR025761"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Surface modification of microelectrodes is a central step in the development of microsensors and microsensor arrays. Here, we present an electrodeposition scheme based on voltage pulses. Key features of this method are uniformity in the deposited electrode coatings, flexibility in the overall deposition area, i.e., the sizes and number of the electrodes to be coated, and precise control of the surface texture. Deposition and characterization of four different materials are demonstrated, including layers of high-surface-area platinum, gold, conducting polymer poly(ethylenedioxythiophene), also known as PEDOT, and the non-conducting polymer poly(phenylenediamine), also known as PPD. The depositions were conducted using a fully integrated complementary metal-oxide-semiconductor (CMOS) chip with an array of 1024 microelectrodes. The pulsed potentiostatic deposition scheme is particularly suitable for functionalization of individual electrodes or electrode subsets of large integrated microelectrode arrays: the required deposition waveforms are readily available in an integrated system, the same deposition parameters can be used to functionalize the surface of either single electrodes or large arrays of thousands of electrodes, and the deposition method proved to be robust and reproducible for all materials tested.<\/jats:p>","DOI":"10.3390\/s17010022","type":"journal-article","created":{"date-parts":[[2016,12,23]],"date-time":"2016-12-23T09:47:26Z","timestamp":1482486446000},"page":"22","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Robust Functionalization of Large Microelectrode Arrays by Using Pulsed Potentiostatic Deposition"],"prefix":"10.3390","volume":"17","author":[{"given":"Joerg","family":"Rothe","sequence":"first","affiliation":[{"name":"ETH Zurich, Department of Biosystems Science and Engineering, Bio Engineering Laboratory, Mattenstrasse 26, CH-4058 Basel, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Olivier","family":"Frey","sequence":"additional","affiliation":[{"name":"ETH Zurich, Department of Biosystems Science and Engineering, Bio Engineering Laboratory, Mattenstrasse 26, CH-4058 Basel, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rajtarun","family":"Madangopal","sequence":"additional","affiliation":[{"name":"Agricultural and Biological Engineering, Biomedical Engineering, Physiological Sensing Facility at the Bindley Bioscience Center and Birck Nanotechnology Center, Purdue University, West Lafayette, IN 47907, USA"},{"name":"Intramural Research Program of the National Institute on Drug Abuse, National Institutes of Health, Baltimore, MD 21224, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jenna","family":"Rickus","sequence":"additional","affiliation":[{"name":"Agricultural and Biological Engineering, Biomedical Engineering, Physiological Sensing Facility at the Bindley Bioscience Center and Birck Nanotechnology Center, Purdue University, West Lafayette, IN 47907, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3838-2468","authenticated-orcid":false,"given":"Andreas","family":"Hierlemann","sequence":"additional","affiliation":[{"name":"ETH Zurich, Department of Biosystems Science and Engineering, Bio Engineering Laboratory, Mattenstrasse 26, CH-4058 Basel, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2016,12,23]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1007\/s00216-003-2149-x","article-title":"Biological application of microelectrode arrays in drug discovery and basic research","volume":"377","author":"Stett","year":"2003","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"553","DOI":"10.1016\/0956-5663(95)96931-N","article-title":"The use of neuronal networks on multielectrode arrays as biosensors","volume":"10","author":"Gross","year":"1995","journal-title":"Biosens. Bioelectron."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1192","DOI":"10.1038\/nbt873","article-title":"Electrochemical DNA sensors","volume":"21","author":"Drummond","year":"2003","journal-title":"Nat. Biotechnol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1394","DOI":"10.1021\/ac702409s","article-title":"Spatially and temporally resolved single-cell exocytosis utilizing individually addressable carbon microelectrode arrays","volume":"80","author":"Zhang","year":"2008","journal-title":"Anal. Chem."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"9028","DOI":"10.1021\/ac102002k","article-title":"Label-free voltammetric detection using individually addressable oligonucleotide microelectrode arrays","volume":"82","author":"Kalantari","year":"2010","journal-title":"Anal. Chem."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/j.neuron.2014.04.044","article-title":"High-Fidelity Reproduction of Spatiotemporal Visual Signals for Retinal Prosthesis","volume":"83","author":"Jepson","year":"2014","journal-title":"Neuron"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.electacta.2015.05.011","article-title":"Development of label-free impedimetric platform based on new conductive polyaniline polymer and three-dimensional interdigitated electrode array for biosensor applications","volume":"173","author":"Bratov","year":"2015","journal-title":"Electrochim. Acta"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1016\/j.bios.2010.07.073","article-title":"Enzyme-based choline and L-glutamate biosensor electrodes on silicon microprobe arrays","volume":"26","author":"Frey","year":"2010","journal-title":"Biosens. Bioelectron."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"243","DOI":"10.4236\/jbnb.2012.322030","article-title":"Transparent Electrode Materials for Simultaneous Amperometric Detection of Exocytosis and Fluorescence Microscopy","volume":"3","author":"Kisler","year":"2012","journal-title":"J. Biomater. Nanobiotechnol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"2767","DOI":"10.1039\/C5LC00133A","article-title":"High-resolution CMOS MEA platform to study neurons at subcellular, cellular, and network levels","volume":"15","author":"Ballini","year":"2015","journal-title":"Lab Chip"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"8","DOI":"10.3389\/fneng.2012.00008","article-title":"PEDOT-CNT Composite Microelectrodes for Recording and Electrostimulation Applications: Fabrication, Morphology, and Electrical Properties","volume":"5","author":"Gerwig","year":"2012","journal-title":"Front. Neuroeng."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1295","DOI":"10.1109\/TBME.2005.847523","article-title":"Impedance characterization and modeling of electrodes for biomedical applications","volume":"52","author":"Franks","year":"2005","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1550","DOI":"10.1016\/j.bios.2008.08.004","article-title":"Permselective and enzyme-entrapping behaviours of an electropolymerized, non-conducting, poly(o-aminophenol) thin film-modified electrode: A critical study","volume":"24","author":"Guerrieri","year":"2009","journal-title":"Biosens. Bioelectron."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1021\/cr0684467","article-title":"DNA biosensors and microarrays","volume":"108","author":"Sassolas","year":"2008","journal-title":"Chem. Rev."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1016\/S0956-5663(97)00064-X","article-title":"Electrosynthesized non-conducting polymers as permselective membranes in amperometric enzyme electrodes: A glucose biosensor based on a co-crosslinked glucose oxidase\/overoxidized polypyrrole bilayer","volume":"13","author":"Guerrieri","year":"1998","journal-title":"Biosens. Bioelectron."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1016\/j.snb.2012.11.057","article-title":"Anti-fouling PEDOT:PSS modification on glassy carbon electrodes for continuous monitoring of tricresyl phosphate","volume":"177","author":"Yang","year":"2013","journal-title":"Sens. Actuators B Chem."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"3313","DOI":"10.1016\/j.electacta.2007.11.054","article-title":"Pulse and pulse reverse plating\u2014Conceptual, advantages and applications","volume":"53","author":"Chandrasekar","year":"2008","journal-title":"Electrochim. Acta"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1499","DOI":"10.1149\/1.2133100","article-title":"Pulsed Potentiostatic Deposition of Gold from Solutions of the Au(I) Sulfite Complex","volume":"124","author":"Horkans","year":"1977","journal-title":"J. Electrochem. Soc."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"4477","DOI":"10.1016\/j.electacta.2005.12.027","article-title":"Electrodeposited platinum revisited: Tuning nanostructure via the deposition potential","volume":"51","author":"Plyasova","year":"2006","journal-title":"Electrochim. Acta"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1016\/j.electacta.2014.05.082","article-title":"Shape-Controllable Pulse Electrodeposition of Ultrafine Platinum Nanodendrites for Methanol Catalytic Combustion and the Investigation of their Local Electric Field Intensification by Electrostatic Force Microscope and Finite Element Method","volume":"136","author":"Liu","year":"2014","journal-title":"Electrochim. Acta"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"6425","DOI":"10.1021\/ac500862v","article-title":"Fully Integrated CMOS Microsystem for Electrochemical Measurements on 32 \u00d7 32 Working Electrodes at 90 Frames Per Second","volume":"86","author":"Rothe","year":"2014","journal-title":"Anal. Chem."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1595\/003214059X324753","article-title":"Electrochemical Properties of the Platinum Metals","volume":"3","author":"Pourbaix","year":"1959","journal-title":"Platin. Met. Rev."},{"key":"ref_23","first-page":"55","article-title":"Permselectivity of films prepared by electrochemical oxidation of phenol and amino-aromatic compounds","volume":"158","author":"Ohnuki","year":"1983","journal-title":"J. Electroanal. Chem. Interfacial Electrochem."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1195","DOI":"10.1021\/ed077p1195","article-title":"Determination of the Real Surface Area of Pt Electrodes by Hydrogen Adsorption Using Cyclic Voltammetry","volume":"77","year":"2000","journal-title":"J. Chem. Educ."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/S0003-2670(01)01399-X","article-title":"Electrochemical nucleic acid biosensors","volume":"469","author":"Wang","year":"2002","journal-title":"Anal. Chim. Acta"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1808","DOI":"10.1149\/1.2115966","article-title":"A Cyclic Voltammetric Study of the Gold-Oxygen System","volume":"131","author":"Hoare","year":"1984","journal-title":"J. Electrochem. Soc."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1408","DOI":"10.1002\/elan.200603552","article-title":"Amperometric Glucose Biosensor Based on Entrapment of Glucose Oxidase in a Poly(3,4-ethylenedioxythiophene) Film","volume":"18","author":"Nien","year":"2006","journal-title":"Electroanalysis"},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Madangopal, R., Stensberg, M., Porterfield, M., Rickus, J., and Pulliam, N. (2012, January 28\u201331). Directed enzyme deposition via electroactive polymer-based nanomaterials for multi-analyte amperometric biosensors. Proceedings of the 2012 IEEE Sensors, Taipei, Taiwan.","DOI":"10.1109\/ICSENS.2012.6411166"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1007\/s00604-003-0067-4","article-title":"Recent Advances in Electropolymerized Conducting Polymers in Amperometric Biosensors","volume":"143","author":"Vidal","year":"2003","journal-title":"Microchim. Acta"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1002\/elan.201300547","article-title":"Application of PEDOT-CNT Microelectrodes for Neurotransmitter Sensing","volume":"26","author":"Samba","year":"2014","journal-title":"Electroanalysis"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/S0022-0728(00)00206-0","article-title":"Electrochemical impedance spectroscopy of oxidized poly(3,4-ethylenedioxythiophene) film electrodes in aqueous solutions","volume":"489","author":"Bobacka","year":"2000","journal-title":"J. Electroanal. Chem."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1754","DOI":"10.1021\/ac00082a025","article-title":"Characterization of Glucose Oxidase-Modified Poly(phenylenediamine)-Coated Electrodes in vitro and in vivo: Homogeneous Interference by Ascorbic Acid in Hydrogen Peroxide Detection","volume":"66","author":"Lowry","year":"1994","journal-title":"Anal. Chem."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/1\/22\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T19:29:13Z","timestamp":1760210953000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/1\/22"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,12,23]]},"references-count":32,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2017,1]]}},"alternative-id":["s17010022"],"URL":"https:\/\/doi.org\/10.3390\/s17010022","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,12,23]]}}}