{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T05:32:24Z","timestamp":1792733544422,"version":"4.5.0"},"reference-count":29,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2016,12,26]],"date-time":"2016-12-26T00:00:00Z","timestamp":1482710400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003958","name":"STW","doi-asserted-by":"publisher","award":["P11-13"],"award-info":[{"award-number":["P11-13"]}],"id":[{"id":"10.13039\/501100003958","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A range of complex percutaneous procedures, such as biopsy or regional anesthesia, rely heavily on accurate needle insertion. Small variations in the mechanical properties of the pierced tissue can however cause deviations from the projected needle path and can thus result in inaccurate placement of the needle. Navigation of a rigid needle towards the target tissue is traditionally based on the surgeons capacity to interpret small variations in the needle insertion force. A more accurate measurement of these small force variations enables improvement in needle targeting, can potentially aid in enhancing force feedback in robotic needle placement and can provide valuable information on tissue-tool interaction. In this study we investigated several concepts for the design of a force sensor based on a fiber-optic Fabry-P\u00e9rot interferometer to measure needle-tissue interaction forces on the tip of a 18 G needle, where special attention was given to concepts for a sensor with (1), an intrinsic low cross-sensitivity to temperature and (2), elementary design and fabrication. Three concepts, using either a quartz capillary, an Invar capillary or a thin polyimide film as the force sensitive element were prototyped and subjected to both static and dynamic testing. The force transducer based on a quartz capillary presented the lowest cross-sensitivity to temperature (    12   m N  \/ \u2218     C) and good accuracy (maximum measurement error of 65     m N    \/10    N   ) in a measurement of static forces. However, limited strength of the sensor is expected to prevent usage of the quartz capillary in small diameter needles. The concepts for a sensor based on an Invar capillary or a thin polyimide film proved a higher cross-sensitivity to temperature (    50   m N  \/ \u2218     C and     220   m N  \/ \u2218     C, respectively) and higher maximum measurement error (350     m N    \/10    N   , 800     m N    \/10    N   ), comparable to those of FBG-based sensors reported in literature, but are likely to be more suitable for integration in very small biopsy needles.<\/jats:p>","DOI":"10.3390\/s17010038","type":"journal-article","created":{"date-parts":[[2016,12,28]],"date-time":"2016-12-28T11:22:14Z","timestamp":1482924134000},"page":"38","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":19,"title":["Fiber-Optic Fabry-P\u00e9rot Interferometers for Axial Force Sensing on the Tip of a Needle"],"prefix":"10.3390","volume":"17","author":[{"given":"Steven","family":"Beekmans","sequence":"first","affiliation":[{"name":"Department of Physics and Astronomy and LaserLab Amsterdam, Vrije Universiteit Amsterdam, Amsterdam 1081 HV, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Lembrechts","sequence":"additional","affiliation":[{"name":"Department of Biomechanical Engineering, Delft University of Technology, Delft 2628 CD, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Van den Dobbelsteen","sequence":"additional","affiliation":[{"name":"Department of Biomechanical Engineering, Delft University of Technology, Delft 2628 CD, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dennis","family":"Van Gerwen","sequence":"additional","affiliation":[{"name":"Department of Biomechanical Engineering, Delft University of Technology, Delft 2628 CD, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2016,12,26]]},"reference":[{"key":"ref_1","unstructured":"Van Gerwen, D.J. (2013). Needle-Tissue Interaction by Experiment. [Ph.D. Thesis, Delft University of Technology]."},{"key":"ref_2","unstructured":"Barb\u00e9, L., Bayle, B., De Mathelin, M., and Gangi, A. (2006, January 20\u201322). Online Robust Model Estimation and Haptic Clues Detection during In Vivo Needle Insertions. Proceedings of the First IEEE\/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, Pisa, Italy."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"965","DOI":"10.1109\/TBME.2005.846734","article-title":"Needle steering and motion planning in soft tissues","volume":"52","author":"DiMaio","year":"2005","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1016\/j.medengphy.2006.07.003","article-title":"Needle insertion into soft tissue: A survey","volume":"29","author":"Abolhassani","year":"2007","journal-title":"Med. Eng. Phys."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1167","DOI":"10.1109\/TBME.2005.847548","article-title":"Interactive simulation of needle insertion models","volume":"52","author":"DiMaio","year":"2005","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1146\/annurev-bioeng-070909-105249","article-title":"Image-Guided Interventions: Technology Review and Clinical Applications","volume":"12","author":"Cleary","year":"2010","journal-title":"Annu. Rev. Biomed. Eng."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1707","DOI":"10.1109\/TBME.2004.831542","article-title":"Force modeling for needle insertion into soft tissue","volume":"51","author":"Okamura","year":"2004","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1109\/4233.826856","article-title":"Schemes for the identification of tissue types and boundaries at the tool point for surgical needles","volume":"4","author":"Brett","year":"2000","journal-title":"IEEE Trans. Inf. Technol. Biomed."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Maurin, B., Barbe, L., Bayle, B., Zanne, P., Gangloff, J., De Mathelin, M., and Gangi, A. (2004, January 11\u201312). In vivo study of forces during needle insertions. Proceedings of the Scientific Workshop on Medical Robotics, Navigation, and Visualization (MRNV\u201904), Remagen, Germany.","DOI":"10.1142\/9789812702678_0056"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Su, H., Zervas, M., Cole, G., Furlong, C., and Fischer, G. (2011, January 9\u201313). Real-time MRI-guided needle placement robot with integrated fiber optic force sensing. Proceedings of the 2011 IEEE International Conference on Robotics and Automation (ICRA), Shanghai, China.","DOI":"10.1109\/ICRA.2011.5979539"},{"key":"ref_11","unstructured":"Henken, K. (2014). Smart Needles for Percutaneous Interventions. [Ph.D. Thesis, Delft University of Technology]."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Elayaperumal, S., Bae, J., Christensen, D., Cutkosky, M., Daniel, B., Black, R., Costa, J., Faridian, F., and Moslehi, B. (2013, January 14\u201317). MR-compatible biopsy needle with enhanced tip force sensing. Proceedings of the World Haptics Conference (WHC), Daejeon, Korea.","DOI":"10.1109\/WHC.2013.6548393"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Udd, E., and Spillman, W.B. (2011). Fiber Optic Sensors, Jonh Wiley & Sons. [2nd ed.].","DOI":"10.1002\/9781118014103"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Heijmans, J., Cheng, L., and Wieringa, F. (2008, January 23\u201327). Optical fiber sensors for medical applications \u2014 Practical engineering considerations. Proceedings of the 4th European Conference of the International Federation for Medical and Biological Engineering, Antwerp, Belgium.","DOI":"10.1007\/978-3-540-89208-3_559"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1016\/j.media.2009.02.001","article-title":"Towards a teleoperated needle driver robot with haptic feedback for RFA of breast tumors under continuous MRI","volume":"13","author":"Kokes","year":"2009","journal-title":"Med. Image Anal."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1016\/j.sna.2004.04.057","article-title":"A micro optical force sensor for force feedback during minimally invasive robotic surgery","volume":"115","author":"Peirs","year":"2004","journal-title":"Sens. Actuators A Phys."},{"key":"ref_17","unstructured":"L\u00f3pez-Higuera, J.M. (2002). Handbook of Optical Fibre Sensing Technology, John Wiley & Sons, Ltd."},{"key":"ref_18","unstructured":"G\u00e4hler, M. (2012). Forces in Needle Interventions. [Ph.D. Thesis, Delft University of Technology]."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"665","DOI":"10.1016\/j.medengphy.2012.04.007","article-title":"Needle\u2013tissue interaction forces\u2014A survey of experimental data","volume":"34","author":"Dankelman","year":"2012","journal-title":"Med. Eng. Phys."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"3247","DOI":"10.1088\/0957-0233\/18\/10\/S30","article-title":"Fibre-top cantilevers: Design, fabrication and applications","volume":"18","author":"Iannuzzi","year":"2007","journal-title":"Meas. Sci. Technol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"2588","DOI":"10.1063\/1.101987","article-title":"Improved fiber-optic interferometer for atomic force microscopy","volume":"55","author":"Rugar","year":"1989","journal-title":"Appl. Phys. Lett."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"7112","DOI":"10.1364\/OE.20.007112","article-title":"Spheroidal Fabry-Perot microcavities in optical fibers for high-sensitivity sensing","volume":"20","author":"Favero","year":"2012","journal-title":"Opt. Express"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1007\/s10544-016-0039-1","article-title":"Characterizing tissue stiffness at the tip of a rigid needle using an opto-mechanical force sensor","volume":"18","author":"Beekmans","year":"2016","journal-title":"Biomed. Microdevices"},{"key":"ref_24","unstructured":"Micco, A., Quero, G., Crescitelli, A., Ricciardi, A., and Cusano, A. (2014). Sensors and Microsystems, Springer International Publishing."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1109\/JPHOT.2014.2319101","article-title":"Temperature-Independent Ultrasensitive Fabry-Perot All-Fiber Strain Sensor Based on a Bubble-Expanded Microcavity","volume":"6","author":"Yin","year":"2014","journal-title":"IEEE Photon. J."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Lin, J., Deng, P., Lam, G., Lu, B., Lee, Y.K., and Tai, Y.C. (2011, January 5\u20139). Creep of parylene-C film. Proceedings of the 2011 16th International Solid-State Sensors, Actuators and Microsystems Conference (TRANSDUCERS), Beijing, China.","DOI":"10.1109\/TRANSDUCERS.2011.5969483"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"4893","DOI":"10.1016\/j.polymer.2006.05.035","article-title":"Thermo-optic coefficients of polymers for optical waveguide applications","volume":"47","author":"Zhang","year":"2006","journal-title":"Polymer"},{"key":"ref_28","unstructured":"Norton, R.L. (2006). Machine Design, Prentice Hall. [3rd ed.]."},{"key":"ref_29","unstructured":"Kuo, C.T., Yip, M.C., and Chiang, K.N. (2002, January 10\u201312). Time and temperature dependent mechanical characterization of polyimide materials in electronic packaging application. Proceedings of the 4th Electronics Packaging Technology Conference, Singapore."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/1\/38\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T19:29:18Z","timestamp":1760210958000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/1\/38"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,12,26]]},"references-count":29,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2017,1]]}},"alternative-id":["s17010038"],"URL":"https:\/\/doi.org\/10.3390\/s17010038","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,12,26]]}}}