{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,12]],"date-time":"2025-11-12T13:54:17Z","timestamp":1762955657923,"version":"build-2065373602"},"reference-count":28,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2016,12,28]],"date-time":"2016-12-28T00:00:00Z","timestamp":1482883200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Japan Society for the Promotion of Science, KAKENHI","award":["JP16H01805"],"award-info":[{"award-number":["JP16H01805"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>In this paper, we propose a blood pressure calculation and associated measurement method that by using a fiber Bragg grating (FBG) sensor. There are several points at which the pulse can be measured on the surface of the human body, and when a FBG sensor located at any of these points, the pulse wave signal can be measured. The measured waveform is similar to the acceleration pulse wave. The pulse wave signal changes depending on several factors, including whether or not the individual is healthy and\/or elderly. The measured pulse wave signal can be used to calculate the blood pressure using a calibration curve, which is constructed by a partial least squares (PLS) regression analysis using a reference blood pressure and the pulse wave signal. In this paper, we focus on the influence of individual differences from calculated blood pressure based on each calibration curve. In our study, the calculated blood pressure from both the individual and overall calibration curves were compared, and our results show that the calculated blood pressure based on the overall calibration curve had a lower measurement accuracy than that based on an individual calibration curve. We also found that the influence of the individual differences on the calculated blood pressure when using the FBG sensor method were very low. Therefore, the FBG sensor method that we developed for measuring the blood pressure was found to be suitable for use by many people.<\/jats:p>","DOI":"10.3390\/s17010048","type":"journal-article","created":{"date-parts":[[2016,12,28]],"date-time":"2016-12-28T11:22:14Z","timestamp":1482924134000},"page":"48","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":39,"title":["Influence of Individual Differences on the Calculation Method for FBG-Type Blood Pressure Sensors"],"prefix":"10.3390","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4297-7648","authenticated-orcid":false,"given":"Shouhei","family":"Koyama","sequence":"first","affiliation":[{"name":"Institute for Fiber Engineering, Shinshu University, 3-15-1 Tokida, Ueda City, Nagano 386-8567, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroaki","family":"Ishizawa","sequence":"additional","affiliation":[{"name":"Institute for Fiber Engineering, Shinshu University, 3-15-1 Tokida, Ueda City, Nagano 386-8567, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Keisaku","family":"Fujimoto","sequence":"additional","affiliation":[{"name":"Department of Clinical Laboratory Sciences, School of Health Sciences, Shinshu University, 3-1-1 Asahi, Matsumoto City, Nagano 390-8621, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shun","family":"Chino","sequence":"additional","affiliation":[{"name":"Graduate School of Science and Technology, Shinshu University, 3-15-1 Tokida, Ueda City, Nagano 386-8567, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuka","family":"Kobayashi","sequence":"additional","affiliation":[{"name":"Graduate School of Science and Technology, Shinshu University, 3-15-1 Tokida, Ueda City, Nagano 386-8567, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2016,12,28]]},"reference":[{"key":"ref_1","unstructured":"Cabinet Office, Government of Japan Situation on Aging, Annual Report on the Aging Society 2015, Available online: http:\/\/www8.cao.go.jp\/kourei\/english\/annualreport\/2015\/pdf\/c1-1.pdf."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Tam, H.Y., Liu, S.Y., Guan, B.O., Chung, W.H., Chan, T.H., and Cheng, L.K. (2005). Fiber bragg grating sensors for structural and railway applications. Proc. SPIE, 5634.","DOI":"10.1117\/12.580803"},{"key":"ref_3","first-page":"1905","article-title":"A fiber bragg grating sensor system for train axle counting","volume":"10","author":"Wei","year":"2014","journal-title":"IEEE Sens. J."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Wei, C.L., Xin, Q., Chung, W.H., Liu, S.Y., Tam, H.Y., and Ho, S.L. (2012). Real-time train wheel condition monitoring by fiber bragg grating sensors. Int. J. Distrib. Sens. Netw.","DOI":"10.1155\/2012\/409048"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1007\/s12200-009-0066-0","article-title":"FBG-based smart bed system for healthcare applications","volume":"1","author":"Hao","year":"2010","journal-title":"Front. Optoelectron."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1614","DOI":"10.1088\/0957-0233\/15\/8\/032","article-title":"A \u2018smart\u2019 bed for non-intrusive monitoring of patient physiological factors","volume":"15","author":"Spillman","year":"2004","journal-title":"Meas. Sci. Technol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1669","DOI":"10.1166\/sl.2014.3382","article-title":"Embedded fiber bragg grating based strain sensor as smart costume for vital signal sensing","volume":"12","author":"Elsarnagawy","year":"2014","journal-title":"Sens. Lett."},{"key":"ref_8","unstructured":"Kawamura, M., Ishizawa, H., Sato, S., and Koyama, S. (2011, January 13\u201318). Application to vital signs by fiber bragg grating sensing. Proceedings of the SICE Annual Conference 2011 Final Program and Papers, Tokyo, Japan."},{"key":"ref_9","unstructured":"Miyauchi, Y., Ishizawa, H., and Koyama, S. (2012, January 24\u201329). The pulse rate measuring system which use FBG sensors. Proceedings of the 13th International Symposium on the Science and Technology of Lighting, New York, NY, USA."},{"key":"ref_10","unstructured":"Sato, S., Ishizawa, H., Hattori, A., and Miyauchi, Y. (2012, January 20\u201323). Study of fixed points in pulse rate measurement by FBG sensor. Proceedings of the SICE Annual Conference 2012 Final Program and Papers, Akita, Japan."},{"key":"ref_11","unstructured":"Miyauchi, Y., Ishizawa, H., Koyama, S., and Sato, S. (2012, January 20\u201323). Verification of the systolic blood-pressure measurement principle by FBG Sensors. Proceedings of the SICE Annual Conference 2012 Final Program and Papers, Akita, Japan."},{"key":"ref_12","unstructured":"Takagi, T., Ishizawa, H., Niimura, M., Koyama, S., Miyauchi, Y., and Katsuragawa, Y. (October, January 28). Basis study on systolic blood pressure measurement by using FBG sensors. Proceedings of the International Symposium on Fiber Science and Technology 2014, Tokyo, Japan."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"2240","DOI":"10.1109\/JLT.2016.2521440","article-title":"Fiber-Bragg-grating based single axial mode Fabry-Perot interferometer and its strain and acceleration sensing applications","volume":"34","author":"Yoshino","year":"2016","journal-title":"J. Lightwave Tech."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1970","DOI":"10.1049\/el:19991328","article-title":"Passive, light intensity-independent interferometric method for fiber Bragg grating interrogation","volume":"35","author":"Todd","year":"1999","journal-title":"Electron. Lett."},{"key":"ref_15","unstructured":"Chino, S., Ishizawa, H., Hosoya, S., Koyama, S., and Fujimoto, K. (2016, January 20\u201323). Non-invasive blood pressure measurement\u2014The study of measuring points. Proceedings of the SICE Annual Conference 2016, Tsukuba, Japan."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Katsuragawa, Y., and Ishizawa, H. (2015, January 11\u201314). Non-invasive blood pressure measurement by pulse wave analysis using FBG sensor. Proceedings of the 2015 IEEE International Instrumentation and Measurement Technology Conference (I2MTC), Pisa, Italy.","DOI":"10.1109\/I2MTC.2015.7151320"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1016\/0009-9120(93)80013-K","article-title":"Near-infrared spectroscopic determination of serum total proteins, albumin, globulins, and urea","volume":"26","author":"Hall","year":"1993","journal-title":"Clin. Biochem."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1255\/jnirs.156","article-title":"Clinical chemistry and near infrared spectroscopy: Technology for non-invasive glucose monitoring","volume":"6","author":"Heise","year":"1998","journal-title":"J. Near Infrared Spectrosc."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1651","DOI":"10.1093\/clinchem\/45.9.1651","article-title":"Noninvasive prediction of glucose by near-infrared diffuse reflectance spectroscopy","volume":"45","author":"Malin","year":"1999","journal-title":"Clin. Chem."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1016\/j.chemolab.2005.08.014","article-title":"Improvement of partial least squares models for in vitro and in vivo glucose quantifications by using near-infrared spectroscopy and searching combination moving window partial least squares","volume":"82","author":"Kasemsumran","year":"2006","journal-title":"Chemom. Intel. Lab. Syst."},{"key":"ref_21","first-page":"153","article-title":"Non-destructive identification and mixture ratio analysis of cotton-polyester blended textile products by IR spectroscopy","volume":"2","author":"Koyama","year":"2013","journal-title":"Text. Light Ind. Sci. Technol."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1137\/0905052","article-title":"The collinearity problem in linear regression, The partial least squares (PLS) approach to generalized inverses","volume":"5","author":"Wold","year":"1984","journal-title":"SIAM. J. Sci. Stat. Comput."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/S0169-7439(01)00155-1","article-title":"PLS-regression, a basic tool of chemometrics","volume":"58","author":"Wold","year":"2001","journal-title":"Chemom. Intel. Lab. Syst."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1002\/cem.1180010105","article-title":"A theoretical foundation for the PLS algorithm","volume":"1","author":"Lorber","year":"1987","journal-title":"J. Chemom."},{"key":"ref_25","unstructured":"Martens, H., and Neas, T. (1989). Multivariate Calibration, John Wiley & Sons."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"111","DOI":"10.4258\/hir.2015.21.2.111","article-title":"Wave detection in acceleration plethysmogram","volume":"21","author":"Ahn","year":"2015","journal-title":"Healthc. Inf. Res."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1186\/1475-925X-13-139","article-title":"Detection of a and b waves in the acceleration photoplethysmogram","volume":"13","author":"Elgendi","year":"2014","journal-title":"BioMed. Eng. Online"},{"key":"ref_28","first-page":"17","article-title":"Evaluation of peripheral circulation with accelerated plethysmography and its practical applications report 2. Quantification of inflection points of a waveform","volume":"68","author":"Sano","year":"1988","journal-title":"Bull. Phys. Fit. Res. Inst."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/1\/48\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T19:29:24Z","timestamp":1760210964000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/1\/48"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,12,28]]},"references-count":28,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2017,1]]}},"alternative-id":["s17010048"],"URL":"https:\/\/doi.org\/10.3390\/s17010048","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2016,12,28]]}}}