{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T20:10:35Z","timestamp":1760213435761,"version":"build-2065373602"},"reference-count":30,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2016,12,30]],"date-time":"2016-12-30T00:00:00Z","timestamp":1483056000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>There has been substantial progress over the last decade towards miniaturizing implantable microelectrodes for use in Active Implantable Medical Devices (AIMD). Compared to the rapid development and complexity of electrode miniaturization, methods to monitor and assess functional integrity and electrical functionality of these electrodes, particularly during long term stimulation, have not progressed to the same extent. Evaluation methods that form the gold standard, such as stimulus pulse testing, cyclic voltammetry and electrochemical impedance spectroscopy, are either still bound to laboratory infrastructure (impractical for long term in vivo experiments) or deliver no comprehensive insight into the material\u2019s behaviour. As there is a lack of cost effective and practical predictive measures to understand long term electrode behaviour in vivo, material investigations need to be performed after explantation of the electrodes. We propose the analysis of the electrode and its environment in situ, to better understand and correlate the effects leading to electrode failure. The derived knowledge shall eventually lead to improved electrode designs, increased electrode functionality and safety in clinical applications. In this paper, the concept, design and prototyping of a sensor framework used to analyse the electrode\u2019s behaviour and to monitor diverse electrode failure mechanisms, even during stimulation pulses, is presented. We focused on the electronic circuitry and data acquisition techniques required for a conceptual multi-sensor system. Functionality of single modules and a prototype framework have been demonstrated, but further work is needed to convert the prototype system into an implantable device. In vitro studies will be conducted first to verify sensor performance and reliability.<\/jats:p>","DOI":"10.3390\/s17010059","type":"journal-article","created":{"date-parts":[[2016,12,30]],"date-time":"2016-12-30T08:48:53Z","timestamp":1483087733000},"page":"59","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Concept and Development of an Electronic Framework Intended for Electrode and Surrounding Environment Characterization In Vivo"],"prefix":"10.3390","volume":"17","author":[{"given":"Stefan","family":"Rieger","sequence":"first","affiliation":[{"name":"Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering (IMTEK), University of Freiburg, Georges-K\u00f6hler-Allee 102, 79110 Freiburg, Germany"},{"name":"Cortec GmbH, Georges-K\u00f6hler Allee 010, 79110 Freiburg, Germany"}]},{"given":"Jennifer","family":"Pfau","sequence":"additional","affiliation":[{"name":"Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering (IMTEK), University of Freiburg, Georges-K\u00f6hler-Allee 102, 79110 Freiburg, Germany"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7349-4254","authenticated-orcid":false,"given":"Thomas","family":"Stieglitz","sequence":"additional","affiliation":[{"name":"Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering (IMTEK), University of Freiburg, Georges-K\u00f6hler-Allee 102, 79110 Freiburg, Germany"},{"name":"BrainLinks-BrainTools Center, University of Freiburg, Georges-K\u00f6hler-Allee 79, 79110 Freiburg, Germany"}]},{"given":"Maria","family":"Asplund","sequence":"additional","affiliation":[{"name":"Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering (IMTEK), University of Freiburg, Georges-K\u00f6hler-Allee 102, 79110 Freiburg, Germany"},{"name":"BrainLinks-BrainTools Center, University of Freiburg, Georges-K\u00f6hler-Allee 79, 79110 Freiburg, Germany"}]},{"given":"Juan","family":"Ordonez","sequence":"additional","affiliation":[{"name":"Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering (IMTEK), University of Freiburg, Georges-K\u00f6hler-Allee 102, 79110 Freiburg, Germany"},{"name":"Freiburg Institute for Advanced Studies (FRIAS), University of Freiburg, Albertstra\u00dfe 19, 79104 Freiburg, Germany"},{"name":"Medtronic, Medtronic Eindhoven Design Center, Neuromodulation High Tech Campus 41, 5656 AE Eindhoven, The Netherlands"}]}],"member":"1968","published-online":{"date-parts":[[2016,12,30]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1016\/j.snb.2012.12.051","article-title":"Charge transfer and stability of implantable electrodes on flexible substrate","volume":"178","author":"Howlader","year":"2013","journal-title":"Sens. Actuators B Chem."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1016\/j.jneumeth.2004.10.020","article-title":"Electrical stimulation of excitable tissue: Design of efficacious and safe protocols","volume":"141","author":"Merrill","year":"2005","journal-title":"J. Neurosci. Methods"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1146\/annurev.bioeng.10.061807.160518","article-title":"Neural stimulation and recording electrodes","volume":"10","author":"Cogan","year":"2008","journal-title":"Annu. Rev. Biomed. Eng."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1016\/j.bioelechem.2003.10.033","article-title":"Thin film platinum cuff electrodes for neurostimulation: In vitro approach of safe neurostimulation parameters","volume":"63","author":"Mailley","year":"2004","journal-title":"Bioelectrochemistry"},{"key":"ref_5","unstructured":"Hu, Z., Troyk, P.R., Brawn, T.P., Margoliash, D., and Cogan, S.F. (September, January 31). In vitro and in vivo charge capacity of AIROF microelectrodes. Proceedings of the IEEE 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBS\u201906), New York, NY, USA."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"056017","DOI":"10.1088\/1741-2560\/11\/5\/056017","article-title":"Laser patterning of platinum electrodes for safe neurostimulation","volume":"11","author":"Green","year":"2014","journal-title":"J. Neural Eng."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Ghoreishizadeh, S.S., Carrara, S., and De Micheli, G. (2013, January 8\u201312). A configurable IC to contol, readout, and calibrate an array of biosensors. Proceedings of the European Conference on Circuit Theory and Design (ECCTD), Dresden, Germany.","DOI":"10.1109\/ECCTD.2013.6662331"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1109\/JSSC.2011.2170633","article-title":"A 3\u00b5 CMOS glucose sensor for wireless contact-lens tear glucose monitoring","volume":"47","author":"Liao","year":"2012","journal-title":"IEEE J. Solid-State Circuits"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"3524","DOI":"10.1109\/JSEN.2015.2392105","article-title":"An implantable telemetry platform system with ASIC for in vivo monitoring of gastrointestinal physiological information","volume":"15","author":"Lu","year":"2015","journal-title":"IEEE Sens. J."},{"key":"ref_10","unstructured":"Stett, A., and Al, E. (2014, January 24\u201325). SMART implant: Electronic implants for diagnosis and monitoring. Proceedings of the 2014 7th GMM-Workshop Energy Self-Sufficient Sensors, Magdeburg, Germany."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Cavallini, A., Baj-Rossi, C., Ghoreishizadeh, S., De Micheli, G., and Carrara, S. (2012, January 28\u201330). Design, fabrication, and test of a sensor array for perspective biosensing in chronic pathologies. Proceedings of the  IEEE Biomedical Circuits and Systems Conference (BioCAS), Hsinchu, Taiwan.","DOI":"10.1109\/BioCAS.2012.6418404"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1109\/JSEN.2014.2356851","article-title":"A highly miniaturized low-power CMOS-based pH monitoring platform","volume":"15","author":"Croce","year":"2015","journal-title":"IEEE Sens. J."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Ativanichayaphong, T., Tang, S.-J., Hsu, L.-C., Huang, W.-D., Seo, Y.-S., Tibbals, H.F., Spechler, S., and Chiao, J.-C. (2010, January 23\u201328). An implantable batteryless wireless impedance sensor for gastroesophageal reflux diagnosis. Proceedings of the IEEE MTT-S International Microwave Symposium, Anaheim, CA, USA.","DOI":"10.1109\/MWSYM.2010.5516775"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1016\/j.yexcr.2005.01.014","article-title":"New insights into the nanometer-scaled cell-surface interspace by cell-sensor measurements","volume":"305","author":"Lehmann","year":"2005","journal-title":"Exp. Cell Res."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Ordonez, J.S., Rudmann, L., Cvancara, P., Bentler, C., and Stieglitz, T. (2015, January 25\u201329). Mechanical deformation of thin film platinum under electrical stimulation. Proceedings of the 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Milano, Italy.","DOI":"10.1109\/EMBC.2015.7318544"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1138","DOI":"10.1149\/1.2108800","article-title":"Piezoelectric Response to Surface Stress Change of Platinum Electrode","volume":"133","author":"Seo","year":"1986","journal-title":"J. Electrochem. Soc."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1515\/cdbme-2015-0126","article-title":"Integration of temperature sensors in polyimide-based thin-film electrode arrays","volume":"1","author":"Cruz","year":"2015","journal-title":"Curr. Dir. Biomed. Eng."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"S121-8","DOI":"10.1088\/1741-2560\/2\/1\/013","article-title":"Fabrication of implantable microelectrode arrays by laser cutting of silicone rubber and platinum foil","volume":"2","author":"Schuettler","year":"2005","journal-title":"J. Neural Eng."},{"key":"ref_19","unstructured":"Porto Cruz, M.F. (2014). Integration of Temperature Sensors in Polyimide-Based Thin-Film Electrode-Arrays. [Master\u2018s Thesis, University of Freiburg]."},{"key":"ref_20","unstructured":"De Sousa, M.J. (2015). Strain Gauges for the Mechanical Characterization of Implantable Microelectrodes. [Master\u2018s Thesis, University of Freiburg]."},{"key":"ref_21","unstructured":"Ultra Low Input Bias Current Instrumentation Amplifier, INA116, Burr Brown. Available online: http:\/\/www.ti.com\/lit\/ds\/symlink\/ina116.pdf."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"4224","DOI":"10.1039\/C5AN00377F","article-title":"An iridium oxide microelectrode for monitoring acute local pH changes of endothelial cells","volume":"140","author":"Ng","year":"2015","journal-title":"Analyst"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1303","DOI":"10.1016\/j.bios.2006.05.033","article-title":"Differential pH measurements of metabolic cellular activity in nl culture volumes using microfabricated iridium oxide electrodes","volume":"22","author":"Ges","year":"2007","journal-title":"Biosens. Bioelectron."},{"key":"ref_24","unstructured":"1 MSPS, 12-Bit Impedance Converter, Network Analyzer, AD5933, Rev. E, Analog Devices. Available online: http:\/\/www.analog.com\/media\/en\/technical-documentation\/data-sheets\/AD5933.pdf."},{"key":"ref_25","unstructured":"Evaluation Board User Guide UG-364, Rev. 0, Anlog Devices. Available online: http:\/\/www.analog.com\/media\/en\/technical-documentation\/evaluation-documentation\/UG-364.pdf."},{"key":"ref_26","unstructured":"Horowitz, P., and Hill, W. (2015). The Art of Electronics, Cambridge University Press. [3rd ed.]."},{"key":"ref_27","unstructured":"Balanced Modulator\/Demodulator, AD630, Rev. F, Analog Devices. Available online: http:\/\/www.analog.com\/media\/en\/technical-documentation\/data-sheets\/AD630.pdf."},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Horch, K.W., and Dhillon, G.S. (2004). Neuroprosthetics Theory Pract, World Scientific.","DOI":"10.1142\/9789812561763"},{"key":"ref_29","unstructured":"Ordonez, J.S., Boehler, C., Schuettler, M., and Stieglitz, T. (September, January 28). Improved polyimide thin-film electrodes for neural implants. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, San Diego, CA, USA."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"590","DOI":"10.1557\/mrs.2012.117","article-title":"Thin films and microelectrode arrays for neuroprosthetics","volume":"37","author":"Ordonez","year":"2012","journal-title":"MRS Bull."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/1\/59\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T19:29:33Z","timestamp":1760210973000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/1\/59"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,12,30]]},"references-count":30,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2017,1]]}},"alternative-id":["s17010059"],"URL":"https:\/\/doi.org\/10.3390\/s17010059","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2016,12,30]]}}}