{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,18]],"date-time":"2026-01-18T13:26:28Z","timestamp":1768742788848,"version":"3.49.0"},"reference-count":45,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2016,12,30]],"date-time":"2016-12-30T00:00:00Z","timestamp":1483056000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Instrument operation in harsh environments often significantly impacts the trust level of measurement data. While commercial instrument manufacturers clearly define the deployment conditions to achieve trustworthy data in typical standard applications, it is frequently unavoidable in scientific field applications to operate instruments outside these commercial standard application specifications. Scientific instrumentation, however, is employing cutting-edge technology and often highly optimized but also lacks long-term field tests to assess the field vs. laboratory performance. Recently, we developed the Selective Extractive Laser Diode Hygrometer (SEALDH-II), which addresses field and especially airborne applications as well as metrological laboratory validations. SEALDH-II targets reducing deviations between airborne hygrometers (currently up to 20% between the most advanced hygrometers) with a new holistic, internal control and validation concept, which guarantees the transfer of the laboratory performance into a field scenario by capturing more than 80 instrument internal \u201chousekeeping\u201d data to nearly perfectly control SEALDH-II\u2019s health status. SEALDH-II uses a calibration-free, first principles based, direct Tuneable Diode Laser Absorption Spectroscopy (dTDLAS) approach, to cover the entire atmospheric humidity measurement range from about 3 to 40,000 ppmv with a calculated maximum uncertainty of 4.3% \u00b1 3 ppmv. This is achieved not only by innovations in internal instrument monitoring and design, but also by active control algorithms such as a high resolution spectral stabilization. This paper describes the setup, working principles, and instrument stabilization, as well as its precision validation and long-term stress tests in an environmental chamber over an environmental temperature and humidity range of \u0394T = 50 K and \u0394RH = 80% RH, respectively.<\/jats:p>","DOI":"10.3390\/s17010068","type":"journal-article","created":{"date-parts":[[2016,12,30]],"date-time":"2016-12-30T08:48:53Z","timestamp":1483087733000},"page":"68","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["SEALDH-II\u2014An Autonomous, Holistically Controlled, First Principles TDLAS Hygrometer for Field and Airborne Applications: Design\u2013Setup\u2013Accuracy\/Stability Stress Test"],"prefix":"10.3390","volume":"17","author":[{"given":"Bernhard","family":"Buchholz","sequence":"first","affiliation":[{"name":"Physikalisch-Technische Bundesanstalt Braunschweig, Braunschweig 38114, Germany"},{"name":"Physikalisch Chemisches Institut, Universit\u00e4t Heidelberg, Heidelberg 69120, Germany"},{"name":"Department of Civil and Environmental Engineering, Princeton University, Princeton, NJ 08540, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S\u00f6ren","family":"Kallweit","sequence":"additional","affiliation":[{"name":"Physikalisch-Technische Bundesanstalt Braunschweig, Braunschweig 38114, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1394-3097","authenticated-orcid":false,"given":"Volker","family":"Ebert","sequence":"additional","affiliation":[{"name":"Physikalisch-Technische Bundesanstalt Braunschweig, Braunschweig 38114, Germany"},{"name":"Physikalisch Chemisches Institut, Universit\u00e4t Heidelberg, Heidelberg 69120, Germany"},{"name":"Center of Smart Interfaces, Technische Universit\u00e4t Darmstadt, Darmstadt 64287, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2016,12,30]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1391","DOI":"10.5194\/acp-8-1391-2008","article-title":"Trends and variability of midlatitude stratospheric water vapour deduced from the re-evaluated Boulder balloon series and HALOE","volume":"8","author":"Scherer","year":"2008","journal-title":"Atmos. Chem. Phys."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1399","DOI":"10.1126\/science.1135199","article-title":"When dry air is too humid","volume":"314","author":"Peter","year":"2006","journal-title":"Science"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1038\/nature12829","article-title":"Spread in model climate sensitivity traced to atmospheric convective mixing","volume":"505","author":"Sherwood","year":"2014","journal-title":"Nature"},{"key":"ref_4","unstructured":"Fahey, D., and Gao, R. Summary of the AquaVIT Water Vapor Intercomparison: Static Experiments. Available online: https:\/\/aquavit.icg.kfa-juelich.de\/WhitePaper\/AquaVITWhitePaper_Final_23Oct2009_6MB.pdf."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"3159","DOI":"10.5194\/amt-7-3177-2014","article-title":"The AquaVIT-1 intercomparison of atmospheric water vapor measurement techniques","volume":"7","author":"Fahey","year":"2014","journal-title":"Atmos. Meas. Tech."},{"key":"ref_6","unstructured":"Mangold, A., and Team, W. Intercomparison of Water Vapour Detectors under Field and Defined Conditions. Available online: http:\/\/adsabs.harvard.edu\/abs\/2003EAEJA.....9330M."},{"key":"ref_7","unstructured":"Hoff, A. WVSS-II Assessment at the DWD Deutscher Wetterdienst\/German Meteorological Service Climate Chamber of the Meteorological Observatory Lindenberg, Available online: https:\/\/amdar.noaa.gov\/docs\/WVSS-II_Assessment_DWD.pdf."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Buchholz, B., and Ebert, V. (2014). Offsets in fiber-coupled diode laser hygrometers caused by parasitic absorption effects and their prevention. Meas. Sci. Technol., 25.","DOI":"10.1088\/0957-0233\/25\/7\/075501"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/S1386-1425(97)00227-8","article-title":"A review of recent advances in semiconductor laser based gas monitors","volume":"54","author":"Werle","year":"1998","journal-title":"Spectrochim. Acta A Mol. Biomol. Spectrosc."},{"key":"ref_10","first-page":"65","article-title":"Tunable diode laser absorption spectroscopy (TDLAS) in the process industries\u2014A review","volume":"23","author":"Lackner","year":"2011","journal-title":"Rev. Chem. Eng."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"829","DOI":"10.1364\/AO.40.000829","article-title":"Wavelength-modulation laser hygrometer for ultrasensitive detection of water vapor in semiconductor gases","volume":"40","author":"Hovde","year":"2001","journal-title":"Appl. Opt."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1163\/156856794X00441","article-title":"The use of tunable diode laser absorption spectroscopy for atmospheric measurements","volume":"20","author":"Schiff","year":"1994","journal-title":"Res. Chem. Intermed."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1364\/AO.44.000091","article-title":"Lightweight diode laser spectrometer \u2018CHILD\u2019 for balloon-borne measurements of water vapor and methane","volume":"44","author":"Gurlit","year":"2005","journal-title":"Appl. Opt."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Diskin, G.S., Podolske, J.R., Sachse, G.W., and Slate, T.A. (2002, January 10\u201311). Open-path airborne tunable diode laser hygrometer. Proceedings of the Diode Lasers and Applications in Atmospheric Sensing, Seattle, WA, USA.","DOI":"10.1117\/12.453736"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"19161","DOI":"10.1029\/98JD01678","article-title":"Open-path, near-infrared tunable diode laser spectrometer for atmospheric measurements of H2O","volume":"103","author":"May","year":"1998","journal-title":"J. Geophys. Res."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Mayinger, F., and Feldmann, O. (2000). Optical Measurements\u2014Techniques and Applications (Heat and Mass Transfer), Springer. [2nd ed.].","DOI":"10.1007\/978-3-642-56443-7"},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Tropea, C., Yarin, A.L., and Foss, J.F. (2007). Handbook of Experimental Fluid Mechanics, Springer.","DOI":"10.1007\/978-3-540-30299-5"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Farooq, A., Jeffries, J., and Hanson, R. (2008). In situ combustion measurements of H2O and temperature near 2.5 \u03bcm using tunable diode laser absorption. Meas. Sci. Technol., 19.","DOI":"10.1088\/0957-0233\/19\/7\/075604"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"8745","DOI":"10.1364\/AO.36.008745","article-title":"Diode laser sensor for measurements of CO, CO2, and CH4 in combustion flows","volume":"36","author":"Mihalcea","year":"1997","journal-title":"Appl.Opt."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1007\/s00340-014-5775-4","article-title":"Absolute validation of a diode laser hygrometer via intercomparison with the German national primary water vapor standard","volume":"116","author":"Buchholz","year":"2014","journal-title":"Appl. Phys. B"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"2347","DOI":"10.1016\/S1386-1425(02)00049-5","article-title":"In situ detection of potassium atoms in high-temperature coal-combustion systems using near-infrared-diode lasers","volume":"58","author":"Schlosser","year":"2002","journal-title":"Spectrochim. Acta A Mol. Biomol. Spectrosc."},{"key":"ref_22","unstructured":"Wunderle, K., Fernholz, T., and Ebert, V. (2006). VDI Berichte, VDI Verlag."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1007\/s00340-012-5242-z","article-title":"Absolute, spatially resolved, in situ CO profiles in atmospheric laminar counter-flow diffusion flames using 2.3 \u03bcm TDLAS","volume":"109","author":"Wagner","year":"2012","journal-title":"Appl. Phys. B"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1016\/j.jqsrt.2009.02.013","article-title":"The HITRAN 2008 molecular spectroscopic database","volume":"110","author":"Rothman","year":"2009","journal-title":"J. Quant. Spectrosc. Radiat. Transf."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1007\/s00340-008-3095-2","article-title":"Absolute, high resolution water transpiration rate measurements on single plant leaves via tunable diode laser absorption spectroscopy (TDLAS) at 1.37 \u03bcm","volume":"92","author":"Hunsmann","year":"2008","journal-title":"Appl. Phys. B"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1007\/s00340-012-5143-1","article-title":"Validation of an extractive, airborne, compact TDL spectrometer for atmospheric humidity sensing by blind intercomparison","volume":"110","author":"Buchholz","year":"2013","journal-title":"Appl. Phys. B"},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Buchholz, B., B\u00f6se, N., Wagner, S., and Ebert, V. (2012, January 22\u201323). Entwicklung eines r\u00fcckf\u00fchrbaren, selbstkalibrierenden, absoluten TDLAS-Hygrometers in kompakter 19\u201d Bauweise. Proceedings of the 16. GMA\/ITG-Fachtagung Sensoren und Messsysteme, Wunstorf, Germany.","DOI":"10.5162\/sensoren2012\/3.2.3"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1524\/teme.72.1.23.56689","article-title":"Fibre-Coupled in-situ Laser Absorption Spectrometer for the Selective Detection of Water Vapour Traces down to the ppb-Level","volume":"72","author":"Ebert","year":"2004","journal-title":"TM Tech. Mess."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1007\/s00340-012-5228-x","article-title":"TDLAS-based open-path laser hygrometer using simple reflective foils as scattering targets","volume":"109","author":"Seidel","year":"2012","journal-title":"Appl. Phys. B"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1007\/s00340-012-5225-0","article-title":"High-speed tunable diode laser absorption spectroscopy for sampling-free in-cylinder water vapor concentration measurements in an optical IC engine","volume":"109","author":"Witzel","year":"2012","journal-title":"Appl. Phys. B"},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Ebert, V. (2006, January 6\u20137). In situ absorption spectrometers using near-IR diode lasers and rugged multi-path-optics for environmental field measurements. Proceedings of the Laser Applilcations to Chemical, Security and Environmental Analysis, Incline Village, NV, USA.","DOI":"10.1364\/LACSEA.2006.WB1"},{"key":"ref_32","unstructured":"Wunderle, K., Al-Zaitone, B., Pa\u0161ti, I., Wagner, S., Hunsmann, S., Tropea, C., and Ebert, V. (2008). VDI Berichte, VDI Verlag."},{"key":"ref_33","unstructured":"Hunsmann, S., Wagner, S., Saathoff, H., M\u00f6hler, O., Schurath, U., and Ebert, V. (2006). VDI Berichte, VDI Verlag."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1016\/j.jqsrt.2006.11.015","article-title":"Speed-dependent Voigt profile for water vapor in infrared remote sensing applications","volume":"105","author":"Boone","year":"2007","journal-title":"J. Quant. Spectrosc. Radiat. Transf."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"472","DOI":"10.1103\/PhysRev.89.472","article-title":"The effect of collisions upon the Doppler width of spectral lines","volume":"89","author":"Dicke","year":"1953","journal-title":"Phys. Rev."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"023111","DOI":"10.1063\/1.4941748","article-title":"Direct single-mode fibre-coupled miniature White cell for laser absorption spectroscopy","volume":"87","author":"Wagner","year":"2016","journal-title":"Rev. Sci. Instrum."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1364\/JOSA.66.000411","article-title":"Very long optical paths in air","volume":"66","author":"White","year":"1976","journal-title":"J. Opt. Soc. Am."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"055109","DOI":"10.1063\/1.4872076","article-title":"Compact, compression-free, displaceable, and resealable vacuum feedthrough with built-in strain relief for sensitive components such as optical fibers","volume":"85","author":"Buchholz","year":"2014","journal-title":"Rev. Sci. Instrum."},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"Muecke, R.J., Scheumann, B., Slemr, F., and Werle, P.W. (1993, January 11\u201314). Calibration procedures for tunable diode laser spectrometers. Proceedings of the Tunable Diode Laser Spectroscopy, Lidar, and DIAL Techniques for Environmental and Industrial Measurement, Atlanta, GA, USA.","DOI":"10.1117\/12.177289"},{"key":"ref_40","unstructured":"Joint Committee for Guides in Metrology (JCGM) (2008). Evaluation of Measurement Data\u2014Guide to the Expression of Uncertainty in Measurement JCGM 100:2008, Bureau International des Poids et Mesures (BIPM)."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1109\/PROC.1966.4634","article-title":"Statistics of atomic frequency standards","volume":"54","author":"Allan","year":"1966","journal-title":"Proc. IEEE"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1007\/BF00425997","article-title":"The limits of signal averaging in atmospheric trace-gas monitoring by tunable diode-laser absorption spectroscopy (TDLAS)","volume":"57","author":"Werle","year":"1993","journal-title":"Appl. Phys. B"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"81","DOI":"10.6028\/jres.081A.010","article-title":"The NBS two-pressure humidity generator, mark 2","volume":"81","author":"Hasegawa","year":"1977","journal-title":"J. Res. Natl. Bur. Stand. Sect. A Phys. Chem."},{"key":"ref_44","unstructured":"Model 2500 Two-Pressure Humidity Generator. Available online: www.thunderscientific.com."},{"key":"ref_45","unstructured":"MBW 373HX MBW Calibration Ltd.. Available online: http:\/\/www.mbw.ch\/wp-content\/uploads\/2014\/11\/MBW_373_Datasheet_EN_V2.1.pdf."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/1\/68\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T19:29:36Z","timestamp":1760210976000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/1\/68"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,12,30]]},"references-count":45,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2017,1]]}},"alternative-id":["s17010068"],"URL":"https:\/\/doi.org\/10.3390\/s17010068","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,12,30]]}}}