{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T05:08:22Z","timestamp":1793250502222,"version":"4.5.0"},"reference-count":31,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2017,1,15]],"date-time":"2017-01-15T00:00:00Z","timestamp":1484438400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A new technique of modulation index adjustment for pure wavelength modulation spectroscopy second harmonic signal waveforms recovery is presented. As the modulation index is a key parameter in determining the exact form of the signals generated by the technique of wavelength modulation spectroscopy, the method of modulation index adjustment is applied to recover the second harmonic signal with wavelength modulation spectroscopy. By comparing the measured profile with the theoretical profile by calculation, the relationship between the modulation index and average quantities of the scanning wavelength can be obtained. Furthermore, when the relationship is applied in the experimental setup by point-by-point modulation index modification for gas detection, the results show good agreement with the theoretical profile and signal waveform distortion (such as the amplitude modulation effect caused by diode laser) can be suppressed. Besides, the method of modulation index adjustment can be used in many other aspects which involve profile improvement. In practical applications, when the amplitude modulation effect can be neglected and the stability of the detection system is limited by the sampling rate of analog-to-digital, modulation index adjustment can be used to improve detection into softer inflection points and solve the insufficient sampling problem. As a result, measurement stability is improved by 40%.<\/jats:p>","DOI":"10.3390\/s17010163","type":"journal-article","created":{"date-parts":[[2017,1,16]],"date-time":"2017-01-16T09:44:02Z","timestamp":1484559842000},"page":"163","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Modulation Index Adjustment for Recovery of Pure Wavelength Modulation Spectroscopy Second Harmonic Signal Waveforms"],"prefix":"10.3390","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8768-2072","authenticated-orcid":false,"given":"Wei","family":"Wei","sequence":"first","affiliation":[{"name":"School of Information Science and Engineering and Shandong Provincial Key Laboratory of Laser Technology and Application, Shandong University, Jinan 250100, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun","family":"Chang","sequence":"additional","affiliation":[{"name":"School of Information Science and Engineering and Shandong Provincial Key Laboratory of Laser Technology and Application, Shandong University, Jinan 250100, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qiang","family":"Wang","sequence":"additional","affiliation":[{"name":"School of Information Science and Engineering and Shandong Provincial Key Laboratory of Laser Technology and Application, Shandong University, Jinan 250100, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zengguang","family":"Qin","sequence":"additional","affiliation":[{"name":"School of Information Science and Engineering and Shandong Provincial Key Laboratory of Laser Technology and Application, Shandong University, Jinan 250100, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2017,1,15]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1007\/s00340-009-3882-4","article-title":"Measurements of the temperature and water vapor concentration in a hot zone by tunable diode laser absorption spectrometry","volume":"100","author":"Bolshov","year":"2010","journal-title":"Appl. Phys. B Lasers Opt."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1007\/s00340-008-3095-2","article-title":"Absolute, high resolution water transpiration rate measurements on single plant leaves via tunable diode laser absorption spectroscopy (TDLAS) at 1.37 \u03bcm","volume":"92","author":"Hunsmann","year":"2008","journal-title":"Appl. Phys. B Lasers Opt."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1007\/s00340-010-3924-y","article-title":"Near infrared diode laser spectroscopy of C2H2, H2O, CO2 and their isotopologues and the application to TDLAS, a tunable diode laser spectrometer for the martian PHOBOS-GRUNT space mission","volume":"99","author":"Durry","year":"2010","journal-title":"Appl. Phys. B Lasers Opt."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"421","DOI":"10.7452\/lapl.201210015","article-title":"Detection of water vapor concentration based on difference value of two adjacent absorption peaks","volume":"9","author":"Wang","year":"2012","journal-title":"Laser Phys. Lett."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"2839","DOI":"10.1016\/j.ijleo.2015.07.041","article-title":"Modified balanced ratio metric detection system used for high sensitive vapor detection","volume":"126","author":"Wei","year":"2015","journal-title":"Optik"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1016\/j.snb.2010.06.058","article-title":"Tunable diode laser spectroscopy with wavelength modulation: Elimination of residual amplitude modulation in a phasor decomposition approach","volume":"150","author":"Ruxton","year":"2010","journal-title":"Sens. Actuators B Chem."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"718","DOI":"10.1364\/AO.31.000718","article-title":"Frequency modulation and wavelength modulation spectroscopies: Comparison of experimental methods using a lead\u2013salt diode laser","volume":"31","author":"Bomse","year":"1992","journal-title":"Appl. Opt."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1185","DOI":"10.1364\/AO.21.001185","article-title":"Atmospheric pressure monitoring of trace gases using tunable diode lasers","volume":"21","author":"Cassidy","year":"1982","journal-title":"Appl. Opt."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1063\/1.1653222","article-title":"High\u2013resolution infrared spectroscopy with a tunable diode laser","volume":"16","author":"Hinkley","year":"1970","journal-title":"Appl. Phys. Lett."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/0022-4073(88)90118-5","article-title":"Diode laser harmonic spectroscopy applied to in situ measurements of atmospheric trace molecules","volume":"40","author":"Loewenstein","year":"1988","journal-title":"J. Quant. Spectrosc. Radiat. Transf."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1806","DOI":"10.1364\/AO.17.001806","article-title":"High sensitivity point monitoring of atmospheric gases employing tunable diode lasers","volume":"17","author":"Reid","year":"1978","journal-title":"Appl. Opt."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1364\/AO.17.000300","article-title":"High sensitivity pollution detection employing tunable diode lasers","volume":"17","author":"Reid","year":"1978","journal-title":"Appl. Opt."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"5211","DOI":"10.1364\/AO.32.005211","article-title":"Diode laser spectroscopy of methane overtone transitions","volume":"32","author":"Lucchesini","year":"1993","journal-title":"Appl. Opt."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1007\/BF01833797","article-title":"Diode laser spectroscopy of overtone bands of acetylene","volume":"63","author":"Lucchesini","year":"1996","journal-title":"Appl. Phys. B Lasers Opt."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1007\/BF00325250","article-title":"Frequency and wavelength\u2013modulation spectroscopies: Comparison of experimental methods using an AlGaAs diode laser","volume":"56","author":"Pavone","year":"1993","journal-title":"Appl. Phys. B Lasers Opt."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1945","DOI":"10.1364\/JOSAB.14.001945","article-title":"Modulation spectroscopy with a semiconductor diode laser by injection\u2013current modulation","volume":"14","author":"Zhu","year":"1997","journal-title":"J. Opt. Soc. Am. B"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"382","DOI":"10.1016\/j.flowmeasinst.2010.04.009","article-title":"Simultaneous measurement on gas concentration and particle mass concentration by tunable diode laser","volume":"21","author":"Wang","year":"2010","journal-title":"Flow Meas. Instrum."},{"key":"ref_18","first-page":"290","article-title":"Measurement of CO2 concentration in flame based on tunable diode laser absorption spectroscopy","volume":"2","author":"Wang","year":"2007","journal-title":"J. Atmos. Environ. Opt."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"3114","DOI":"10.1109\/JLT.2007.904937","article-title":"Tunable diode-laser spectroscopy with wavelength modulation: A calibration-free approach to the recovery of absolute gas absorption line shapes","volume":"25","author":"Duffin","year":"2007","journal-title":"J. Lightwave Technol."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1007\/s00340-014-5956-1","article-title":"Wavelength modulation spectroscopy with signal\u2013reference beam method for highly sensitive gas detection","volume":"118","author":"Wei","year":"2015","journal-title":"Appl. Phys. B"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"5546","DOI":"10.1364\/AO.48.005546","article-title":"Calibration-free wavelength-modulation spectroscopy for measurements of gas temperature and concentration in harsh environments","volume":"48","author":"Rieker","year":"2009","journal-title":"Appl. Opt."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1364\/AO.55.000479","article-title":"Fiber-coupled diode-laser sensors for calibration-free stand-off measurements of gas temperature, pressure, and composition","volume":"55","author":"Goldenstein","year":"2016","journal-title":"Appl. Opt."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"6728","DOI":"10.1364\/AO.42.006728","article-title":"Wavelength modulation spectroscopy: Combined frequency and intensity laser modulation","volume":"42","author":"Schilt","year":"2003","journal-title":"Appl. Opt."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"6090","DOI":"10.1364\/AO.32.006090","article-title":"Laser diode wavelength\u2013modulation spectroscopy for simultaneous measurement of temperature, pressure and velocity in shock-heated oxygen flows","volume":"32","author":"Philippe","year":"1993","journal-title":"Appl. Opt."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"25943","DOI":"10.1364\/OE.24.025943","article-title":"Purely wavelength- and amplitude-modulated quartz-enhanced photoacoustic spectroscopy","volume":"24","author":"Patimisco","year":"2016","journal-title":"Opt. Express"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"9602","DOI":"10.1364\/OE.17.009602","article-title":"Elimination of residual amplitude modulation in tunable diode laser wavelength modulation spectroscopy using an optical fiber delay line","volume":"17","author":"Chakraborty","year":"2009","journal-title":"Opt. Express"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1364\/OE.18.000267","article-title":"Influence of the wavelength-dependence of fiber couplers on the background signal in wavelength modulation spectroscopy with RAM-nulling","volume":"18","author":"Chakraborty","year":"2010","journal-title":"Opt. Express"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"9582","DOI":"10.3390\/s150409582","article-title":"Immunity to Laser Power Variation in a DFB Diode Laser Based Optical Gas Sensor Using a Division Process","volume":"15","author":"Chang","year":"2015","journal-title":"Sensors"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1015","DOI":"10.1007\/s00340-014-5922-y","article-title":"Dual-beam wavelength modulation spectroscopy for sensitive detection of water vapor","volume":"117","author":"Wang","year":"2014","journal-title":"Appl. Phys. B"},{"key":"ref_30","first-page":"811","article-title":"Recovery of Absolute Gas Absorption Line Shapes Using Tunable Diode Laser Spectroscopy with Wavelength Modulation\u2014Part I: Theoretical Analysis","volume":"29","author":"Stewart","year":"2011","journal-title":"J. Lightwave Technol."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1109\/JSEN.2014.2343653","article-title":"Continuously wavelength-tunable light source with constant-power output for elimination of residual amplitude modulation","volume":"15","author":"Zhu","year":"2015","journal-title":"IEEE Sens. J."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/1\/163\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T18:26:16Z","timestamp":1760207176000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/1\/163"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,1,15]]},"references-count":31,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2017,1]]}},"alternative-id":["s17010163"],"URL":"https:\/\/doi.org\/10.3390\/s17010163","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,1,15]]}}}