{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T09:40:13Z","timestamp":1789551613009,"version":"build-2803163510"},"reference-count":22,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2017,1,20]],"date-time":"2017-01-20T00:00:00Z","timestamp":1484870400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A common feature of the inflammatory response in patients who have actually contracted influenza is the generation of a number of volatile products of the alveolar and airway epithelium. These products include a number of volatile organic compounds (VOCs) and nitric oxide (NO). These may be used as biomarkers to detect the disease. A portable 3-sensor array microsystem-based tool that can potentially detect flu infection biomarkers is described here. Whether used in connection with in-vitro cell culture studies or as a single exhale breathalyzer, this device may be used to provide a rapid and non-invasive screening method for flu and other virus-based epidemics.<\/jats:p>","DOI":"10.3390\/s17010199","type":"journal-article","created":{"date-parts":[[2017,1,20]],"date-time":"2017-01-20T10:10:12Z","timestamp":1484907012000},"page":"199","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":38,"title":["Novel Isoprene Sensor for a Flu Virus Breath Monitor"],"prefix":"10.3390","volume":"17","author":[{"given":"Pelagia-Irene","family":"Gouma","sequence":"first","affiliation":[{"name":"Department of Materials Science &amp; Engineering &amp; IPPM-UTARI, University of Texas at Arlington, Arlington, TX 76019, USA"},{"name":"Center for Nanomaterials and Sensor Development, State University of New York, Stony Brook, NY 11794, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lisheng","family":"Wang","sequence":"additional","affiliation":[{"name":"Center for Nanomaterials and Sensor Development, State University of New York, Stony Brook, NY 11794, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sanford","family":"Simon","sequence":"additional","affiliation":[{"name":"Center for Nanomaterials and Sensor Development, State University of New York, Stony Brook, NY 11794, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Milutin","family":"Stanacevic","sequence":"additional","affiliation":[{"name":"Center for Nanomaterials and Sensor Development, State University of New York, Stony Brook, NY 11794, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2017,1,20]]},"reference":[{"key":"ref_1","unstructured":"CDC: Flu Activity Expands, Available online: http:\/\/www.cdc.gov\/flu\/news\/flu-activity-expands.htm."},{"key":"ref_2","unstructured":"Weekly US Influenza Surveillance Report, Available online: http:\/\/www.cdc.gov\/flu\/weekly."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"10370","DOI":"10.1128\/JVI.78.19.10370-10377.2004","article-title":"Analysis of Human Peripheral Blood Samples from Fatal and Nonfatal Cases of Ebola (Sudan) Hemorragic Fever: Cellular Responses, Virus Load, and Nitric Oxide Levels","volume":"78","author":"Sanchez","year":"2004","journal-title":"J. Virol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"037107","DOI":"10.1088\/1752-7155\/5\/3\/037107","article-title":"Effect of influenza A (H1N1) live attenuated intranasal vaccine on nitric oxide (FENO) and other volatiles in exhaled breath","volume":"5","author":"Mashir","year":"2011","journal-title":"J. Breath Res."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"026001","DOI":"10.1088\/1752-7155\/4\/2\/026001","article-title":"Effect of influenza vaccination on oxidative stress products in breath","volume":"4","author":"Phillips","year":"2010","journal-title":"J. Breath Res."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"037110","DOI":"10.1088\/1752-7155\/8\/3\/037110","article-title":"Volatile emanations from in vitro airway cells infected with human rhinovirus","volume":"8","author":"Schivo","year":"2014","journal-title":"J. Breath Res."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"037110","DOI":"10.1088\/1752-7155\/5\/3\/037110","article-title":"A Selective Nanosensor Device for Exhaled Breath Analysis","volume":"5","author":"Gouma","year":"2011","journal-title":"J. Breath Res."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"S48","DOI":"10.1088\/0957-4484\/17\/4\/008","article-title":"Selective Nanoprobes for \u2018Signaling Gases\u2019","volume":"17","author":"Gouma","year":"2006","journal-title":"Nanotechnology"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1109\/JSEN.2009.2036050","article-title":"Chemical sensor and breath analyzer for ammonia detection in exhaled human breath","volume":"10","author":"Gouma","year":"2010","journal-title":"IEEE Sens."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1166\/sl.2010.1334","article-title":"Nanosensor Device for Breath Acetone Detection","volume":"8","author":"Wang","year":"2010","journal-title":"Sens. Lett."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"787","DOI":"10.1166\/sam.2011.1204","article-title":"Nanoscale Polymorphic Oxides for Selective Chemosensors","volume":"3","author":"Gouma","year":"2011","journal-title":"Sci. Adv. Mater."},{"key":"ref_12","first-page":"186","article-title":"Controlling Gas Selectivity through Polyorphic Selection for Metal Oxide Chemical Detectors","volume":"20","author":"Gouma","year":"2004","journal-title":"Chem. Sens."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"045001","DOI":"10.1088\/2053-1613\/2\/4\/045001","article-title":"An overview of the translation of selective semiconducting gas sensors from first results to automotive exhaust gas monitors to a platform for breath-based diagnostics","volume":"2","author":"Gouma","year":"2015","journal-title":"Transl. Mater. Res."},{"key":"ref_14","first-page":"123","article-title":"Nanostructured Polymorphic Oxides for Advanced Chemosensors","volume":"5","author":"Gouma","year":"2003","journal-title":"Rev. Adv. Mater. Sci."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Carpenter, M.A., Mathur, S., and Kolmakov, A. (2013). Metal Oxide Nanomaterials for Chemical Sensors, Springer.","DOI":"10.1007\/978-1-4614-5395-6"},{"key":"ref_16","unstructured":"Wang, L. (2008). Tailored Synthesis and Characterization of Selective Metabolite-Detecting Nanoprobes for Handheld Breath Analysis. [Ph.D. Thesis, Stony Brook University]."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1016\/0022-4596(79)90199-3","article-title":"Structural study of a new hexagonal form of tungsten trioxide","volume":"29","author":"Gerand","year":"1979","journal-title":"J. Solid State Chem."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"2641","DOI":"10.1021\/ac062334y","article-title":"Can breath isoprene be measured by ozone chemiluminescence?","volume":"79","author":"Ohira","year":"2007","journal-title":"Anal. Chem."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1016\/j.snb.2006.01.027","article-title":"Sensing of organic vapors by flame-made TiO2 nanoparticles","volume":"119","author":"Teleki","year":"2006","journal-title":"Sens. Actuators B"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.proeng.2014.11.254","article-title":"Selective Chemosensing and diagnostic Breathalyzer","volume":"87","author":"Gouma","year":"2014","journal-title":"Proced. Eng."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Perrone, L.A., Belser, A.J., Wadford, D.A., Katz, J.M., and Tumpey, T.M. (2013). Inducible Nitric Oxide Contributes to Viral Pathogenesis Following Highly Pathogenic Influenza Virus Infection in Mice. J. Infect. Dis., 207.","DOI":"10.1093\/infdis\/jit062"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1040","DOI":"10.1002\/cbic.201300695","article-title":"Cellular Scent of Influenza Virus Infection","volume":"15","author":"Askenov","year":"2014","journal-title":"ChemBioChem"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/1\/199\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T18:26:39Z","timestamp":1760207199000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/1\/199"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,1,20]]},"references-count":22,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2017,1]]}},"alternative-id":["s17010199"],"URL":"https:\/\/doi.org\/10.3390\/s17010199","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,1,20]]}}}