{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T16:42:49Z","timestamp":1788540169102,"version":"build-2803163510"},"reference-count":43,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2017,1,25]],"date-time":"2017-01-25T00:00:00Z","timestamp":1485302400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>We propose a novel simple method for quantitative and qualitative finger-tapping assessment based on miniature inertial sensors (3D gyroscopes) placed on the thumb and index-finger. We propose a simplified description of the finger tapping by using a single angle, describing rotation around a dominant axis. The method was verified on twelve subjects, who performed various tapping tasks, mimicking impaired patterns. The obtained tapping angles were compared with results of a motion capture camera system, demonstrating excellent accuracy. The root-mean-square (RMS) error between the two sets of data is, on average, below 4\u00b0, and the intraclass correlation coefficient is, on average, greater than 0.972. Data obtained by the proposed method may be used together with scores from clinical tests to enable a better diagnostic. Along with hardware simplicity, this makes the proposed method a promising candidate for use in clinical practice. Furthermore, our definition of the tapping angle can be applied to all tapping assessment systems.<\/jats:p>","DOI":"10.3390\/s17020203","type":"journal-article","created":{"date-parts":[[2017,1,25]],"date-time":"2017-01-25T09:50:44Z","timestamp":1485337844000},"page":"203","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":37,"title":["Quantification of Finger-Tapping Angle Based on Wearable Sensors"],"prefix":"10.3390","volume":"17","author":[{"given":"Milica","family":"Djuri\u0107-Jovi\u010di\u0107","sequence":"first","affiliation":[{"name":"Innovation Center, School of Electrical Engineering, University of Belgrade, Bulevar kralja Aleksandra 73, 11120 Belgrade, Serbia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nenad","family":"Jovi\u010di\u0107","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering, University of Belgrade, Bulevar kralja Aleksandra 73, 11120 Belgrade, Serbia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6196-7229","authenticated-orcid":false,"given":"Agnes","family":"Roby-Brami","sequence":"additional","affiliation":[{"name":"Institut des Syst\u00e8mes Intelligents et de Robotique, Universit\u00e9 Pierre et Marie Curie, 4 Place JUSSIEU, 75005 Paris, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mirjana","family":"Popovi\u0107","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering, University of Belgrade, Bulevar kralja Aleksandra 73, 11120 Belgrade, Serbia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vladimir","family":"Kosti\u0107","sequence":"additional","affiliation":[{"name":"Institute for Neurology, School of Medicine, University of Belgrade, Dr. Suboti\u0107a 6, 11120 Belgrade, Serbia"},{"name":"Serbian Academy of Sciences and Arts, Knez Mihajlova 35, 11001 Belgrade, Serbia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonije","family":"Djordjevi\u0107","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering, University of Belgrade, Bulevar kralja Aleksandra 73, 11120 Belgrade, Serbia"},{"name":"Serbian Academy of Sciences and Arts, Knez Mihajlova 35, 11001 Belgrade, Serbia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2017,1,25]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"624","DOI":"10.1136\/jnnp.67.5.624","article-title":"Bradykinesia akinesia in co-ordination test (BRAIN TEST): An objective computerized assessment of upper limb motor function","volume":"67","author":"Giovannoni","year":"1999","journal-title":"J. Neurol. Neurosurg. Psychiatry"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1136\/jnnp.57.1.22","article-title":"Measuring ataxia: Quantification based on the standard neurological examination","volume":"57","author":"Notermans","year":"1994","journal-title":"J. Neurol. Neurosurg. Psychiatry"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"714","DOI":"10.1136\/jnnp.50.6.714","article-title":"Arm function after stroke: Measurement and recovery over the first three months","volume":"50","author":"Heller","year":"1987","journal-title":"J. Neurol. Neurosurg. Psychiatry"},{"key":"ref_4","first-page":"71","article-title":"Quantitative assessment of movement in Alzheimer\u2019s disease","volume":"8","author":"Ott","year":"1995","journal-title":"J. Geriatr. Psychiatry Neurol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1186\/s12938-015-0067-8","article-title":"Quantitative assessment of parkinsonian bradykinesia based on an inertial measurement unit","volume":"14","author":"Dai","year":"2015","journal-title":"Biomed. Eng. Online"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1109\/JBHI.2015.2412656","article-title":"Instrumental assessment of bradykinesia: A comparison between motor tasks","volume":"20","author":"Mentzel","year":"2016","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"18813","DOI":"10.3390\/s150818813","article-title":"Upper limb kinematics using inertial and magnetic sensors: Comparison of sensor-to-segment calibrations","volume":"15","author":"Bouvier","year":"2015","journal-title":"Sensors"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1016","DOI":"10.1109\/TBME.2015.2480242","article-title":"A method for automatic and objective scoring of bradykinesia using orientation sensors and classification algorithms","volume":"63","author":"Roosma","year":"2016","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1628","DOI":"10.1002\/mds.25628","article-title":"Quantitative wearable sensors for objective assessment of Parkinson\u2019s disease","volume":"28","author":"Maetzler","year":"2013","journal-title":"Mov. Disord."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"2129","DOI":"10.1002\/mds.22340","article-title":"Movement Disorder Society-sponsored revision of the Unified Parkinson\u2019s Disease Rating Scale (MDS-UPDRS): Scale presentation and clinimetric testing results","volume":"23","author":"Goetz","year":"2008","journal-title":"Mov. Disord."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1002\/mds.10313","article-title":"Impairment of individual finger movements in Parkinson\u2019s disease","volume":"18","author":"Agostino","year":"2003","journal-title":"Mov. Disord."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1017\/S0317167100009197","article-title":"Tasks of attention augment rigidity in mild Parkinson disease","volume":"35","author":"Mendonca","year":"2008","journal-title":"Can. J. Neurol. Sci."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.1002\/mds.22014","article-title":"Provocation of Parkinsonian tremor","volume":"23","author":"Raethjen","year":"2008","journal-title":"Mov. Disord."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1453","DOI":"10.1002\/mds.20220","article-title":"Assuring interrater reliability for the UPDRS motor section: Utility of UPDRS teaching tape","volume":"19","author":"Goetz","year":"2004","journal-title":"Mov. Disord."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1007\/s11517-010-0697-8","article-title":"Quantification of bradykinesia during clinical finger taps using a gyrosensor in patients with Parkinson\u2019s disease","volume":"49","author":"Kim","year":"2011","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1859","DOI":"10.1002\/mds.23740","article-title":"The modified bradykinesia rating scale for Parkinson\u2019s disease: Reliability and comparison with kinematic measures","volume":"26","author":"Heldman","year":"2011","journal-title":"Mov. Disord."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"717853","DOI":"10.1155\/2013\/717853","article-title":"Finger tapping clinimetric score prediction in Parkinson\u2019s disease using low-cost accelerometers","volume":"2013","author":"Stamatakis","year":"2013","journal-title":"Comput. Intell. Neurosci."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1141","DOI":"10.1093\/brain\/aws038","article-title":"Hypokinesia without decrement distinguishes progressive supranuclear palsy from Parkinson\u2019s disease","volume":"135","author":"Ling","year":"2012","journal-title":"Brain"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.jneumeth.2004.05.009","article-title":"Analysis of finger-tapping movement","volume":"141","author":"Harcos","year":"2005","journal-title":"J. Neurosci. Methods"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"013119","DOI":"10.1063\/1.3683444","article-title":"Finger tapping movements of Parkinson\u2019s disease patients automatically rated using nonlinear delay differential equations","volume":"22","author":"Lainscsek","year":"2012","journal-title":"Chaos"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/1353-8020(95)00001-1","article-title":"Measurement and analysis of single and multiple finger tapping in normal and parkinsonian subjects","volume":"1","author":"Muir","year":"1995","journal-title":"Parkinsonism Relat. Disord."},{"key":"ref_22","unstructured":"Okuno, R., Yokoe, M., Akazawa, K., Abe, K., and Sakoda, S. (September, January 31). Finger taps movement acceleration measurement system for quantitative diagnosis of Parkinson\u2019s disease. Proceedings of the 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, New York, NY, USA."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1016\/j.parkreldis.2008.11.003","article-title":"Opening velocity, a novel parameter, for finger tapping test in patients with Parkinson\u2019s disease","volume":"15","author":"Yokoe","year":"2009","journal-title":"Parkinsonism Relat. Disord."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1007\/s11517-012-0863-2","article-title":"Statistical characteristics of finger-tapping data in Huntington\u2019s disease","volume":"50","author":"Antoniades","year":"2012","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Shima, K., Tsuji, T., Kan, E., Kandori, A., Yokoe, M., and Sakoda, S. (2008, January 20\u201325). Measurement and evaluation of finger tapping movements using magnetic sensors. Proceedings of the 30th Annual International IEEE EMBS, Vancouver, BC, Canada.","DOI":"10.1109\/IEMBS.2008.4650490"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"16965","DOI":"10.3390\/s131216965","article-title":"Automatic and objective assessment of alternating tapping performance in Parkinson\u2019s disease","volume":"13","author":"Memedi","year":"2013","journal-title":"Sensors"},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Van den Noort, J.C., Kortier, H.G., van Beek, N., Veeger, D.H., and Veltink, P.H. (2016). Measuring 3D Hand and Finger Kinematics\u2014A Comparison between Inertial Sensing and an Opto-Electronic Marker System. PLoS ONE, 11.","DOI":"10.1371\/journal.pone.0164889"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1109\/TBME.2006.886670","article-title":"Quantification of tremor and bradykinesia in Parkinson\u2019s disease using a novel ambulatory monitoring system","volume":"54","author":"Salarian","year":"2007","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"10571","DOI":"10.3390\/s111110571","article-title":"Kinematics of gait: New method for angle estimation based on accelerometers","volume":"11","year":"2011","journal-title":"Sensors"},{"key":"ref_30","first-page":"1","article-title":"Wireless distributed functional electrical stimulation system","volume":"9","author":"Saranovac","year":"2012","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_31","unstructured":"Goldstein, H., Poole, C., and Safko, J. (2000). Classical Mechanics, Addison Wesley."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1093\/comjnl\/7.4.308","article-title":"A simplex method for function minimization","volume":"7","author":"Nelder","year":"1965","journal-title":"Comput. J."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"2849","DOI":"10.1016\/j.jbiomech.2012.08.028","article-title":"Nonlinear Optimization for Drift Removal in Estimation of Gait Kinematics Based on Accelerometers","volume":"45","year":"2012","journal-title":"J. Biomech."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"8536","DOI":"10.3390\/s110908536","article-title":"Angle estimation of simultaneous orthogonal rotations from 3D gyroscope measurements","volume":"11","year":"2011","journal-title":"Sensors"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"2465","DOI":"10.1002\/sim.4780132310","article-title":"A critical discussion of intraclass correlation coefficients","volume":"13","year":"1994","journal-title":"Stat. Med."},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Hrabia, C.E., Wolf, K., and Wilhelm, M. (2013, January 7\u20138). Whole hand modeling using 8 wearable sensors: Biomechanics for hand pose prediction. Proceedings of the 4th Augmented Human International Conference, Stuttgart, Germany.","DOI":"10.1145\/2459236.2459241"},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Hoffman, J.D., and McNames, J. (September, January 30). Objective measure of upper extremity motor impairment in Parkinson\u2019s disease with inertial sensors. Proceedings of the 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Boston, MA, USA.","DOI":"10.1109\/IEMBS.2011.6091086"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1016\/j.jneumeth.2011.03.019","article-title":"Kinematic optimization of deep brain stimulation across multiple motor symptoms in Parkinson\u2019s disease","volume":"198","author":"Mera","year":"2011","journal-title":"J. Neurosci. Meth."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1016\/S1050-6411(98)00050-9","article-title":"Comparative analysis of diadochokinetic movements","volume":"9","author":"Marquardt","year":"1999","journal-title":"J. Electromyogr. Kines."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"2504","DOI":"10.1002\/mds.23893","article-title":"Differential response of speed, amplitude, and rhythm to dopaminergic medications in Parkinson\u2019s disease","volume":"26","author":"Espay","year":"2011","journal-title":"Mov. Disord."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.jocn.2015.10.053","article-title":"Finger tapping analysis in patients with Parkinson\u2019s disease and atypical Parkinsonism","volume":"30","year":"2016","journal-title":"J. Clin. Neurosci."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"2187","DOI":"10.3390\/s90302187","article-title":"Measurement and evaluation of finger tapping movements using log-linearized Gaussian mixture networks","volume":"9","author":"Shima","year":"2009","journal-title":"Sensors"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"590","DOI":"10.1016\/j.parkreldis.2014.02.022","article-title":"Clinician versus machine: Reliability and responsiveness of motor endpoints in Parkinson\u2019s disease","volume":"20","author":"Heldman","year":"2014","journal-title":"Parkinsonism Relat. Disord."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/2\/203\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T18:26:56Z","timestamp":1760207216000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/2\/203"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,1,25]]},"references-count":43,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2017,2]]}},"alternative-id":["s17020203"],"URL":"https:\/\/doi.org\/10.3390\/s17020203","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,1,25]]}}}