{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,14]],"date-time":"2026-03-14T16:48:46Z","timestamp":1773506926610,"version":"3.50.1"},"reference-count":24,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2017,1,27]],"date-time":"2017-01-27T00:00:00Z","timestamp":1485475200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"the Japanese Ministry of Internal Affairs and Communications","award":["132308004"],"award-info":[{"award-number":["132308004"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>In this study, we describe a technique for estimating meal times using an earphone-type wearable sensor. A small optical sensor composed of a light-emitting diode and phototransistor is inserted into the ear hole of a user and estimates the meal times of the user from the time variations in the amount of light received. This is achieved by emitting light toward the inside of the ear canal and receiving light reflected back from the ear canal. This proposed technique allowed \u201cmeals\u201d to be differentiated from having conversations, sneezing, walking, ascending and descending stairs, operating a computer, and using a smartphone. Conventional devices worn on the head of users and that measure food intake can vibrate during running as the body is jolted more violently than during walking; this can result in the misidentification of running as eating by these devices. To solve this problem, we used two of our sensors simultaneously: one in the left ear and one in the right ear. This was based on our finding that measurements from the left and right ear canals have a strong correlation during running but no correlation during eating. This allows running and eating to be distinguished based on correlation coefficients, which can reduce misidentification. Moreover, by using an optical sensor composed of a semiconductor, a small and lightweight device can be created. This measurement technique can also measure body motion associated with running, and the data obtained from the optical sensor inserted into the ear can be used to support a healthy lifestyle regarding both eating and exercise.<\/jats:p>","DOI":"10.3390\/s17020252","type":"journal-article","created":{"date-parts":[[2017,1,27]],"date-time":"2017-01-27T11:23:02Z","timestamp":1485516182000},"page":"252","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":21,"title":["A Novel Earphone Type Sensor for Measuring Mealtime: Consideration of the Method to Distinguish between Running and Meals"],"prefix":"10.3390","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5774-5124","authenticated-orcid":false,"given":"Kazuhiro","family":"Taniguchi","sequence":"first","affiliation":[{"name":"Graduate School of Information Sciences, Hiroshima City University, 3-4-1 Ozukahigashi, Asaminami-ku, Hiroshima 731-3194, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hikaru","family":"Chiaki","sequence":"additional","affiliation":[{"name":"Graduate School of Information Sciences, Hiroshima City University, 3-4-1 Ozukahigashi, Asaminami-ku, Hiroshima 731-3194, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mami","family":"Kurosawa","sequence":"additional","affiliation":[{"name":"Graduate School of Science and Technology, Shinshu University, 3-15-1, Tokida, Ueda, Nagano 386-8567, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5669-1726","authenticated-orcid":false,"given":"Atsushi","family":"Nishikawa","sequence":"additional","affiliation":[{"name":"Faculty of Textile Science and Technology, Shinshu University, 3-15-1, Tokida, Ueda, Nagano 386-8567, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2017,1,27]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Winokur, E.S., He, D.D., and Sodini, C.G. (September, January 28). A wearable vital signs monitor at the ear for continuous heart rate and Pulse Transit Time measurements. Proceedings of the 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), San Diego, CA, USA.","DOI":"10.1109\/EMBC.2012.6346527"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Shen, C.L., Kao, T., Huang, C.T., and Lee, J.H. (2006, January 11\u201314). Wearable band using a fabric\u2013based sensor for exercise ECG monitoring. Proceedings of the 2006 10th IEEE International Symposium on Wearable Computers, Montreux, Switzerland.","DOI":"10.1109\/ISWC.2006.286367"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Hung, K., Zhang, Y.T., and Tai, B. (2004, January 1\u20134). Wearable Medical Devices for Tele-Home Healthcare. Proceedings of the 26th Annual International Conference of the IEEE on Engineering in Medicine and Biology Society, San Francisco, CA, USA.","DOI":"10.1109\/IEMBS.2004.1404503"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1109\/MCE.2014.2317895","article-title":"How Wearables Intersect with the Cloud and the Internet of Things Considerations for the Developers of Wearables","volume":"3","author":"Wei","year":"2014","journal-title":"IEEE Consum. Electron. Mag."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Constant, N., Prawl, O.D., Johnson, S., and Mankodiya, K. (2015, January 9\u201312). Pulse-glasses: An unobtrusive, wearable HR monitor with Internet-of-Things functionality. Proceedings of the 2015 IEEE 12th International Conference on Wearable and Implantable Body Sensor Networks (BSN), Cambridge, MA, USA.","DOI":"10.1109\/BSN.2015.7299350"},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Salehizadeh, S.M.A., Noh, Y., and Chon, K.H. (2016, January 27\u201329). Heart rate monitoring during intense physical activities using a motion artifact corrupted signal reconstruction algorithm in wearable electrocardiogram sensor. Proceedings of the IEEE 1st International Conference on Connected Health: Applications, Systems and Engineering Technologies (CHASE), Washington, DC, USA.","DOI":"10.1109\/CHASE.2016.8"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1109\/JBHI.2015.2458779","article-title":"BioWatch: A Noninvasive Wrist-Based Blood Pressure Monitor That Incorporates Training Techniques for Posture and Subject Variability","volume":"20","author":"Thomas","year":"2016","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_8","unstructured":"Zhang, H., Sun, Y., Lu, Y., Lan, J., and Ji, Y. (2015, January 19). A novel motion and Noise Artifacts Reduction Mechanism (MNARM) for wearable PPG-based heart rate extraction. Proceedings of the 2015 IET International Conference on Biomedical Image and Signal Processing (ICBISP 2015), Beijing, China."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Preejith, S.P., Alex, A., Joseph, J., and Sivaprakasam, M. (2016, January 15\u201318). Design, development and clinical validation of a wrist-based optical heart rate monitor. Proceedings of the 2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA), Benevento, Italy.","DOI":"10.1109\/MeMeA.2016.7533786"},{"key":"ref_10","unstructured":"Ye, X., Chen, G., and Cao, Y. (2015, January 14\u201317). Automatic eating detection using head-mount and wrist-worn accelerometers. Proceedings of the 17th International Conference on e-Health Networking, Application & Services (HealthCom), Boston, MA, USA."},{"key":"ref_11","unstructured":"Long, X., Yin, B., and Aarts, R. (2009, January 2\u20136). Single-accelerometer-based daily physical activity classification. Proceedings of the Annual International Conference of the IEEE on Engineering in Medicine and Biology Society, Minneapolis, MN, USA."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"656","DOI":"10.20965\/jrm.2007.p0656","article-title":"Evaluation of a Wearable Sensor System Monitoring Posture Changes and Activities for Use in Rehabilitation","volume":"19","author":"Motoi","year":"2007","journal-title":"J. Robot. Mechatron."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Mannini, A., and Sabatini, A. (September, January 30). On-line classification of human activity and estimation of walk-run speed from acceleration data using support vector machines. Proceedings of the 2011 IEEE Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Boston, MA, USA.","DOI":"10.1109\/IEMBS.2011.6090896"},{"key":"ref_14","unstructured":"James, D.A., Davey, N., and Rice, T. (2004, January 24\u201327). An accelerometer based sensor platform for in situ elite athlete performance analysis. Proceedings of the IEEE Sensors, Vienna, Austria."},{"key":"ref_15","unstructured":"B\u00e4chlin, M., F\u00f6rster, K., and Tr\u00f6ster, G. (October, January 30). SwimMaster: A wearable assistant for swimmer. Proceedings of the 11th International Conference on Ubiquitous Computing, Orlando, FL, USA."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Atallah, L., Aziz, O., Lo, B., and Yang, G.Z. (2009, January 3\u20135). Detecting walking gait impairment with an ear-worn sensor. Proceedings of the 6th International Workshop on Wearable and Implantable Body Sensor Networks, Berkeley, CA, USA.","DOI":"10.1109\/BSN.2009.41"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"848","DOI":"10.1016\/j.cmet.2012.04.019","article-title":"Time-Restricted Feeding without Reducing Caloric Intake Prevents Metabolic Diseases in Mice Fed a High-Fat Diet","volume":"15","author":"Hatori","year":"2012","journal-title":"Cell Metab."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Farooq, M., and Sazonov, E. (2016). A Novel Wearable Device for Food Intake and Physical Activity Recognition. Sensors, 16.","DOI":"10.3390\/s16071067"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1772","DOI":"10.1109\/TBME.2014.2306773","article-title":"Automatic Ingestion Monitor: A Novel Wearable Device for Monitoring of Ingestive Behavior","volume":"61","author":"Fontana","year":"2014","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"260","DOI":"10.20965\/jrm.2008.p0260","article-title":"KOMEKAMI Switch: A Novel Wearable Input Device Using Movement of Temple","volume":"20","author":"Taniguchi","year":"2008","journal-title":"Int. J. Robot. Mechatron."},{"key":"ref_21","unstructured":"Taniguchi, K., Nishikawa, A., Miyazaki, F., and Kokubo, A. (2015). Input Device, Wearable Computer, and Input Method. (8,994,647), U.S. Patent."},{"key":"ref_22","unstructured":"Taniguchi, K., Horise, Y., Nishikawa, A., and Iwaki, S. (2012, January 8\u201311). A novel wearable input device using movement of ear-canals. Proceedings of the 2012 5th Textile Bioengineering and Informatics symposium (TBIS), Ueda, Japan."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"270","DOI":"10.2186\/jjps.33.270","article-title":"Changes in Chewing Rhythm During Repetitive Series of Mastication in Normal Adults as a Function of Time Elapsed and the Four Basic Taste Stimuli","volume":"33","author":"Amano","year":"1989","journal-title":"Nihon Hotetsu Shika Gakkai Zasshi"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Liu, J.D., Johns, E., Atallah, L., Pettitt, C., Lo, B., Frost, G., and Yang, G.Z. (2012, January 9\u201312). An Intelligent Food-Intake Monitoring System Using Wearable Sensors. Proceedings of the 2012 9th International Conference on Wearable and Implantable Body Sensor Networks, London, UK.","DOI":"10.1109\/BSN.2012.11"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/2\/252\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T18:27:09Z","timestamp":1760207229000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/2\/252"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,1,27]]},"references-count":24,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2017,2]]}},"alternative-id":["s17020252"],"URL":"https:\/\/doi.org\/10.3390\/s17020252","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,1,27]]}}}