{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T04:11:29Z","timestamp":1760242289072,"version":"build-2065373602"},"reference-count":64,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2017,3,3]],"date-time":"2017-03-03T00:00:00Z","timestamp":1488499200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Research Grants Council of HKSAR","award":["CUHK 416712","14113214"],"award-info":[{"award-number":["CUHK 416712","14113214"]}]},{"DOI":"10.13039\/501100003452","name":"Innovation and Technology Commission","doi-asserted-by":"publisher","award":["GHP\/028\/14SZ","ITS\/293\/14FP"],"award-info":[{"award-number":["GHP\/028\/14SZ","ITS\/293\/14FP"]}],"id":[{"id":"10.13039\/501100003452","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100010877","name":"Science, Technology and Innovation Commission of Shenzhen Municipality","doi-asserted-by":"publisher","award":["CXZZ20140606164105361"],"award-info":[{"award-number":["CXZZ20140606164105361"]}],"id":[{"id":"10.13039\/501100010877","id-type":"DOI","asserted-by":"publisher"}]},{"name":"CUHK Technology and Business Development Fund","award":["TBF16MED002","TBF16MED004"],"award-info":[{"award-number":["TBF16MED002","TBF16MED004"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Dynamic magnetic resonance imaging (MRI) has been extensively utilized for enhancing medical living environment visualization, however, in clinical practice it often suffers from long data acquisition times. Dynamic imaging essentially reconstructs the visual image from raw (k,t)-space measurements, commonly referred to as big data. The purpose of this work is to accelerate big medical data acquisition in dynamic MRI by developing a non-convex minimization framework. In particular, to overcome the inherent speed limitation, both non-convex low-rank and sparsity constraints were combined to accelerate the dynamic imaging. However, the non-convex constraints make the dynamic reconstruction problem difficult to directly solve through the commonly-used numerical methods. To guarantee solution efficiency and stability, a numerical algorithm based on Alternating Direction Method of Multipliers (ADMM) is proposed to solve the resulting non-convex optimization problem. ADMM decomposes the original complex optimization problem into several simple sub-problems. Each sub-problem has a closed-form solution or could be efficiently solved using existing numerical methods. It has been proven that the quality of images reconstructed from fewer measurements can be significantly improved using non-convex minimization. Numerous experiments have been conducted on two in vivo cardiac datasets to compare the proposed method with several state-of-the-art imaging methods. Experimental results illustrated that the proposed method could guarantee the superior imaging performance in terms of quantitative and visual image quality assessments.<\/jats:p>","DOI":"10.3390\/s17030509","type":"journal-article","created":{"date-parts":[[2017,3,3]],"date-time":"2017-03-03T11:30:04Z","timestamp":1488540604000},"page":"509","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Reconstruction of Undersampled Big Dynamic MRI Data Using Non-Convex Low-Rank and Sparsity Constraints"],"prefix":"10.3390","volume":"17","author":[{"given":"Ryan","family":"Liu","sequence":"first","affiliation":[{"name":"Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Shatin 999077, N.T., Hong Kong, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lin","family":"Shi","sequence":"additional","affiliation":[{"name":"Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Shatin 999077, N.T., Hong Kong, China"},{"name":"Chow Yuk Ho Technology Center for Innovative Medicine, The Chinese University of Hong Kong, Shatin 999077, N.T., Hong Kong, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Simon","family":"Yu","sequence":"additional","affiliation":[{"name":"Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Shatin 999077, N.T., Hong Kong, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0394-4635","authenticated-orcid":false,"given":"Naixue","family":"Xiong","sequence":"additional","affiliation":[{"name":"Department of Mathematics and Computer Science, Northeastern State University, Tahlequah, OK 74464, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Defeng","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Shatin 999077, N.T., Hong Kong, China"},{"name":"Research Center for Medical Image Computing, The Chinese University of Hong Kong, Shatin 999077, N.T., Hong Kong, China"},{"name":"Shenzhen Research Institute, The Chinese University of Hong Kong, Shenzhen 518057, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2017,3,3]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1056\/NEJM199303183281109","article-title":"Magnetic resonance imaging","volume":"328","author":"Edelman","year":"1993","journal-title":"N. Engl. J. Med."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1109\/JSAC.2009.090512","article-title":"Comparative analysis of quality of service and memory usage for adaptive failure detectors in healthcare systems","volume":"27","author":"Xiong","year":"2009","journal-title":"IEEE J. Sel. Areas Commun."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1038\/nrclinonc.2012.2","article-title":"Dynamic contrast-enhanced MRI in clinical trials of antivascular therapies","volume":"9","author":"Jackson","year":"2012","journal-title":"Nat. Rev. Clin. Oncol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1254","DOI":"10.1109\/TPDS.2010.29","article-title":"A distributed efficient flow control scheme for multirate multicast networks","volume":"21","author":"Xiong","year":"2010","journal-title":"IEEE Trans. Parallel Distrib. Syst."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"820","DOI":"10.1016\/j.mri.2010.03.038","article-title":"The clinical usefulness of preoperative dynamic MRI to select decompression levels for cervical spondylotic myelopathy","volume":"28","author":"Harada","year":"2010","journal-title":"Magn. Reson. Imaging"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1451","DOI":"10.1007\/s00330-012-2446-x","article-title":"Imaging vascular function for early stage clinical trials using dynamic contrast-enhanced magnetic resonance imaging","volume":"22","author":"Leach","year":"2012","journal-title":"Eur. Radiol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1016\/j.ins.2016.12.030","article-title":"EPCBIR: An efficient and privacy-preserving content-based image retrieval scheme in cloud computing","volume":"387","author":"Xia","year":"2016","journal-title":"Inf. Sci."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"7309","DOI":"10.1088\/0031-9155\/58\/20\/7309","article-title":"Accelerating free breathing myocardial perfusion MRI using multi coil radial k-t SLR","volume":"58","author":"Lingala","year":"2013","journal-title":"Phys. Med. Biol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"625","DOI":"10.1109\/42.476104","article-title":"Reconstruction of 3-D left ventricular motion from planar tagged cardiac MR images: An estimation theoretic approach","volume":"14","author":"Denney","year":"1995","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1002\/1522-2594(200009)44:3<457::AID-MRM17>3.0.CO;2-R","article-title":"Prospective acquisition correction for head motion with image-based tracking for real-time fMRI","volume":"44","author":"Thesen","year":"2000","journal-title":"Magn. Reson. Med."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"756","DOI":"10.1109\/TBME.2013.2289306","article-title":"Prostate MRI segmentation using learned semantic knowledge and graph cuts","volume":"61","author":"Mahapatra","year":"2014","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1947","DOI":"10.1007\/s11042-014-2381-8","article-title":"Steganalysis of LSB matching using differences between nonadjacent pixels","volume":"75","author":"Xia","year":"2016","journal-title":"Multimed. Tools Appl."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"778","DOI":"10.1016\/j.patcog.2016.06.020","article-title":"An improved anisotropic hierarchical fuzzy c-means method based on multivariate student t-distribution for brain MRI segmentation","volume":"60","author":"Chen","year":"2016","journal-title":"Pattern Recognit."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"10049","DOI":"10.1016\/j.eswa.2011.02.012","article-title":"A hybrid method for MRI brain image classification","volume":"38","author":"Zhang","year":"2011","journal-title":"Expert Syst. Appl."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1016\/j.ins.2014.10.040","article-title":"A rapid learning algorithm for vehicle classification","volume":"295","author":"Wen","year":"2015","journal-title":"Inf. Sci."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1109\/TNNLS.2015.2508025","article-title":"A locality-constrained and label embedding dictionary learning algorithm for image classification","volume":"28","author":"Li","year":"2017","journal-title":"IEEE Trans. Neural Netw. Learn. Syst."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"5167","DOI":"10.1118\/1.4927793","article-title":"A two-step optimization approach for nonlocal total variation-based Rician noise reduction in magnetic resonance images","volume":"42","author":"Liu","year":"2015","journal-title":"Med. Phys."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1016\/j.mri.2016.12.024","article-title":"Bayesian MRI denoising in complex domain","volume":"38","author":"Baselice","year":"2017","journal-title":"Magn. Reson. Imaging"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/j.media.2016.12.001","article-title":"Perfusion deconvolution in DSC-MRI with dispersion-compliant bases","volume":"36","author":"Pizzolato","year":"2017","journal-title":"Med. Image Anal."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"886","DOI":"10.1002\/mrm.22868","article-title":"Issues of discontinuity in the impulse residue function for deconvolution analysis of dynamic contrast-enhanced MRI data","volume":"66","author":"Koh","year":"2011","journal-title":"Magn. Reson. Med."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"741","DOI":"10.1016\/j.mri.2012.02.001","article-title":"Temporal\/spatial resolution improvement of in vivo DCE-MRI with compressed sensing-optimized FLASH","volume":"30","author":"Han","year":"2012","journal-title":"Magn. Reson. Imaging"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"10807","DOI":"10.1073\/pnas.162368899","article-title":"In vivo quantification of localized neuronal activation and inhibition in the rat brain using a dedicated high temporal-resolution \u03b2+-sensitive microprobe","volume":"99","author":"Pain","year":"2002","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_23","unstructured":"Boschetto, D., Di Prima, P., Castellaro, M., Bertoldo, A., and Grisan, E. (May, January 29). Baseline constrained reconstruction of DSC-MRI tracer kinetics from sparse fourier data. Proceedings of the IEEE International Symposium on Biomedical Imaging, Beijing, China."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1109\/TIT.2005.862083","article-title":"Robust uncertainty principles: Exact signal reconstruction from highly incomplete frequency information","volume":"52","author":"Candes","year":"2006","journal-title":"IEEE Trans. Inf. Theory"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1289","DOI":"10.1109\/TIT.2006.871582","article-title":"Compressed sensing","volume":"52","author":"Donoho","year":"2006","journal-title":"IEEE Trans. Inf. Theory"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1182","DOI":"10.1002\/mrm.21391","article-title":"Sparse MRI: The application of compressed sensing for rapid MR imaging","volume":"58","author":"Lustig","year":"2007","journal-title":"Magn. Reson. Med."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1109\/MSP.2007.914728","article-title":"Compressed sensing MRI","volume":"25","author":"Lustig","year":"2008","journal-title":"IEEE Signal Process. Mag."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"546814","DOI":"10.1155\/2014\/546814","article-title":"Energy preserved sampling for compressed sensing MRI","volume":"2014","author":"Zhang","year":"2014","journal-title":"Comput. Math. Method Med."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.ins.2015.06.017","article-title":"Exponential wavelet iterative shrinkage thresholding algorithm for compressed sensing magnetic resonance imaging","volume":"322","author":"Zhang","year":"2015","journal-title":"Inf. Sci."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"160139","DOI":"10.1155\/2013\/160139","article-title":"Accelerating dynamic cardiac MR imaging using structured sparse representation","volume":"2013","author":"Cai","year":"2013","journal-title":"Comput. Math. Methods Med."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1002\/mrm.21757","article-title":"k-t FOCUSS: A general compressed sensing framework for high resolution dynamic MRI","volume":"61","author":"Jung","year":"2009","journal-title":"Magn. Reson. Med."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"3201","DOI":"10.1088\/0031-9155\/52\/11\/018","article-title":"Improved k-t BLAST and k-t SENSE using FOCUSS","volume":"52","author":"Jung","year":"2007","journal-title":"Phys. Med. Biol."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1002\/mrm.24440","article-title":"Highly accelerated real-time cardiac cine MRI using k-t SPARSE-SENSE","volume":"70","author":"Feng","year":"2013","journal-title":"Magn. Reson. Med."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1007\/s10208-009-9045-5","article-title":"Exact matrix completion via convex optimization","volume":"9","author":"Candes","year":"2009","journal-title":"Found. Comput. Math."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"1125","DOI":"10.1002\/mrm.25240","article-title":"Low-rank plus sparse matrix decomposition for accelerated dynamic MRI with separation of background and dynamic components","volume":"73","author":"Otazo","year":"2015","journal-title":"Magn. Reson. Med."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1109\/TIP.2015.2503238","article-title":"A truncated nuclear norm regularization method based on weighted residual error for matrix completion","volume":"25","author":"Liu","year":"2016","journal-title":"IEEE Trans. Image Process."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"1828","DOI":"10.1109\/TCYB.2015.2454521","article-title":"Robust semi-supervised subspace clustering via non-negative low-rank representation","volume":"46","author":"Fang","year":"2016","journal-title":"IEEE Trans. Cybern."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"1042","DOI":"10.1109\/TMI.2010.2100850","article-title":"Accelerated dynamic MRI exploiting sparsity and low-rank structure: k-t SLR","volume":"30","author":"Lingala","year":"2011","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"1809","DOI":"10.1109\/TMI.2012.2203921","article-title":"Image reconstruction from highly undersampled (k,t)-space data with joint partial separability and sparsity constraints","volume":"31","author":"Zhao","year":"2012","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1145\/1970392.1970395","article-title":"Robust principal component analysis?","volume":"58","author":"Candes","year":"2011","journal-title":"J. ACM"},{"key":"ref_41","first-page":"167","article-title":"Sparse and low-rank matrix decomposition via alternating direction methods","volume":"9","author":"Yuan","year":"2013","journal-title":"Pac. J. Optim."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1137\/100781894","article-title":"Recovering low-rank and sparse components of matrices from incomplete and noisy observations","volume":"21","author":"Tao","year":"2011","journal-title":"SIAM J. Optim."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1093\/imaiai\/iat002","article-title":"Compressive principal component pursuit","volume":"2","author":"Wright","year":"2013","journal-title":"Inf. Inference"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"1689","DOI":"10.1109\/TMI.2014.2321190","article-title":"Dynamic MR image reconstruction-separation from undersampled (k,t)-space via low-rank plus sparse prior","volume":"33","author":"Dikaios","year":"2014","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1016\/j.mri.2010.09.001","article-title":"An algorithm for sparse MRI reconstruction by Schatten p-norm minimization","volume":"29","author":"Majumdar","year":"2011","journal-title":"Magn. Reson. Imaging"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1109\/TMI.2008.927346","article-title":"Highly undersampled magnetic resonance image reconstruction via homotopic l0-minimization","volume":"28","author":"Trzasko","year":"2009","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1016\/j.mri.2012.10.026","article-title":"Improved dynamic MRI reconstruction by exploiting sparsity and rank-deficiency","volume":"31","author":"Majumdar","year":"2013","journal-title":"Magn. Reson. Imaging"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1109\/CC.2016.7489970","article-title":"Efficient algorithm for k-barrier coverage based on integer linear programming","volume":"13","author":"Zhang","year":"2016","journal-title":"China Commun."},{"key":"ref_49","first-page":"639","article-title":"Non-convex joint-sparsity regularization for synergistic PET and SENSE MRI reconstruction","volume":"57","author":"Mehranian","year":"2016","journal-title":"J. Nucl. Med."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"1364","DOI":"10.1109\/LSP.2015.2406314","article-title":"Artifact-free wavelet denoising: Non-convex sparse regularization, convex optimization","volume":"22","author":"Ding","year":"2015","journal-title":"IEEE Signal Process. Lett."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"1246","DOI":"10.1109\/TIP.2016.2515985","article-title":"CONCOLOR: Constrained non-convex low-rank model for image deblocking","volume":"25","author":"Zhang","year":"2016","journal-title":"IEEE Trans. Image Process."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1109\/LSP.2007.898300","article-title":"Exact reconstruction of sparse signals via nonconvex minimization","volume":"14","author":"Chartrand","year":"2007","journal-title":"IEEE Signal Process. Lett."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"035020:1","DOI":"10.1088\/0266-5611\/24\/3\/035020","article-title":"Restricted isometry properties and nonconvex compressive sensing","volume":"24","author":"Chartrand","year":"2008","journal-title":"Inverse. Probl."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1109\/CC.2016.7559076","article-title":"Fingerprint liveness detection based on multi-scale LPQ and PCA","volume":"13","author":"Yuan","year":"2016","journal-title":"China Commun."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"4686","DOI":"10.1109\/TSP.2009.2026004","article-title":"Recovering sparse signals with a certain family of nonconvex penalties and DC programming","volume":"57","author":"Gasso","year":"2009","journal-title":"IEEE Trans. Signal Process."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"702","DOI":"10.1016\/j.mri.2014.03.004","article-title":"Generalized total variation-based MRI Rician denoising model with spatially adaptive regularization parameters","volume":"32","author":"Liu","year":"2014","journal-title":"Magn. Reson. Imaging"},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"1942","DOI":"10.1109\/TNNLS.2013.2297381","article-title":"Multilinear sparse principal component analysis","volume":"25","author":"Lai","year":"2014","journal-title":"IEEE Trans. Neural Netw. Learn. Syst."},{"key":"ref_58","doi-asserted-by":"crossref","unstructured":"Zhou, X., Yang, C., Zhao, H., and Yu, W. (2015). Low-rank modeling and its applications in image analysis. ACM Comput. Surv., 47.","DOI":"10.1145\/2674559"},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1561\/2200000016","article-title":"Distributed optimization and statistical learning via the alternating direction method of multipliers","volume":"3","author":"Boyd","year":"2011","journal-title":"Found. Trends Mach. Learn."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"1956","DOI":"10.1137\/080738970","article-title":"A singular value thresholding algorithm for matrix completion","volume":"20","author":"Cai","year":"2010","journal-title":"SIAM J. Optim."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"1900","DOI":"10.1109\/TCYB.2015.2457611","article-title":"Low-rank preserving projections","volume":"46","author":"Lu","year":"2016","journal-title":"IEEE Trans. Cybern."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1109\/18.382009","article-title":"De-noising by soft-thresholding","volume":"41","author":"Donoho","year":"1995","journal-title":"IEEE Trans. Inf. Theory"},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"1413","DOI":"10.1002\/cpa.20042","article-title":"An iterative thresholding algorithm for linear inverse problems with a sparsity constraint","volume":"57","author":"Daubechies","year":"2004","journal-title":"Commun. Pure Appl. Math."},{"key":"ref_64","doi-asserted-by":"crossref","unstructured":"Zuo, W.M., Meng, D.Y., Zhang, L., Feng, X.C., and Zhang, D. (2013, January 1\u20138). A generalized iterated shrinkage algorithm for non-convex sparse coding. Proceedings of the IEEE International Conference on Computer Vision, Sydney, Australia.","DOI":"10.1109\/ICCV.2013.34"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/3\/509\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T18:29:41Z","timestamp":1760207381000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/3\/509"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,3,3]]},"references-count":64,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2017,3]]}},"alternative-id":["s17030509"],"URL":"https:\/\/doi.org\/10.3390\/s17030509","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2017,3,3]]}}}