{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T03:31:44Z","timestamp":1780371104875,"version":"3.54.1"},"reference-count":22,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2017,3,24]],"date-time":"2017-03-24T00:00:00Z","timestamp":1490313600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003132","name":"Agentschap voor Innovatie door Wetenschap en Technologie","doi-asserted-by":"publisher","award":["120057"],"award-info":[{"award-number":["120057"]}],"id":[{"id":"10.13039\/501100003132","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Real-time detection of multiple stance events, more specifically initial contact (IC), foot flat (FF), heel off (HO), and toe off (TO), could greatly benefit neurorobotic (NR) and neuroprosthetic (NP) control. Three real-time threshold-based algorithms have been developed, detecting the aforementioned events based on kinematic data in combination with a biomechanical model. Data from seven subjects walking at three speeds on an instrumented treadmill were used to validate the presented algorithms, accumulating to a total of 558 steps. The reference for the gait events was obtained using marker and force plate data. All algorithms had excellent precision and no false positives were observed. Timing delays of the presented algorithms were similar to current state-of-the-art algorithms for the detection of IC and TO, whereas smaller delays were achieved for the detection of FF. Our results indicate that, based on their high precision and low delays, these algorithms can be used for the control of an NR\/NP, with the exception of the HO event. Kinematic data is used in most NR\/NP control schemes and is thus available at no additional cost, resulting in a minimal computational burden. The presented methods can also be applied for screening pathological gait or gait analysis in general in\/outside of the laboratory.<\/jats:p>","DOI":"10.3390\/s17040671","type":"journal-article","created":{"date-parts":[[2017,3,24]],"date-time":"2017-03-24T11:38:27Z","timestamp":1490355507000},"page":"671","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":39,"title":["Real-Time Gait Event Detection Based on Kinematic Data Coupled to a Biomechanical Model \u2020"],"prefix":"10.3390","volume":"17","author":[{"given":"Stefan","family":"Lambrecht","sequence":"first","affiliation":[{"name":"Division PMA, Department of Mechanical Engineering, Katholieke Universiteit Leuven, 3000 Leuven, Belgium"},{"name":"Department of Biomedical Kinesiology, Katholieke Universiteit Leuven, 3000 Leuven, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna","family":"Harutyunyan","sequence":"additional","affiliation":[{"name":"AI Laboratory, Vrije Universiteit Brussel, 1050 Ixelles, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin","family":"Tanghe","sequence":"additional","affiliation":[{"name":"Division PMA, Department of Mechanical Engineering, Katholieke Universiteit Leuven, 3000 Leuven, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maarten","family":"Afschrift","sequence":"additional","affiliation":[{"name":"Department of Biomedical Kinesiology, Katholieke Universiteit Leuven, 3000 Leuven, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joris","family":"De Schutter","sequence":"additional","affiliation":[{"name":"Division PMA, Department of Mechanical Engineering, Katholieke Universiteit Leuven, 3000 Leuven, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ilse","family":"Jonkers","sequence":"additional","affiliation":[{"name":"Department of Biomedical Kinesiology, Katholieke Universiteit Leuven, 3000 Leuven, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2017,3,24]]},"reference":[{"key":"ref_1","unstructured":"Reinkensmeyer, D.J., Hogan, N., Krebs, H.I., Lehman, S.L., Lum, P.S., and Newman, D.J. (2000). Biomechanics and Neural Control of Posture and Movement, Springer."},{"key":"ref_2","first-page":"701","article-title":"A mechanized gait trainer for restoration of gait","volume":"37","author":"Hesse","year":"2000","journal-title":"J. Rehabil. Res. Dev."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1109\/TNSRE.2003.823266","article-title":"Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait","volume":"12","author":"Blaya","year":"2004","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1016\/j.gaitpost.2003.10.001","article-title":"Assessment and validation of a simple automated method for the detection of gait events and intervals","volume":"20","author":"Ghoussayni","year":"2004","journal-title":"Gait Posture"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1016\/S0021-9290(02)00008-8","article-title":"Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes","volume":"35","author":"Aminian","year":"2002","journal-title":"J. Biomech."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1109\/TNSRE.2014.2337914","article-title":"A Novel Adaptive, Real-Time Algorithm to Detect Gait Events From Wearable Sensors","volume":"23","author":"Ambrosini","year":"2015","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1016\/j.jbiomech.2015.12.035","article-title":"Gait recording with inertial sensors\u2014How to determine initial and terminal contact","volume":"49","author":"Marti","year":"2016","journal-title":"J. Biomech."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1016\/j.medengphy.2010.03.007","article-title":"Methods for gait event detection and analysis in ambulatory systems","volume":"32","author":"Rueterbories","year":"2010","journal-title":"Med. Eng. Phys."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1251","DOI":"10.1007\/s11517-010-0692-0","article-title":"An adaptive gyroscope-based algorithm for temporal gait analysis","volume":"48","author":"Greene","year":"2010","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1016\/j.neunet.2008.03.006","article-title":"Powered ankle-foot prosthesis to assist level-ground and stair-descent gaits","volume":"21","author":"Au","year":"2008","journal-title":"Neural Netw."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1016\/j.medengphy.2009.10.014","article-title":"Inertial Gait Phase Detection for control of a drop foot stimulator Inertial sensing for gait phase detection","volume":"32","author":"Kotiadis","year":"2010","journal-title":"Med. Eng. Phys."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1109\/7333.928571","article-title":"A reliable gait phase detection system","volume":"9","author":"Pappas","year":"2001","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1109\/TNSRE.2002.806832","article-title":"A review of portable FES-based neural orthoses for the correction of drop foot","volume":"10","author":"Lyons","year":"2002","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_14","unstructured":"Ott, E., Munih, M., Benko, H., and Kralj, A. (1998, January 22\u201324). Comparison of foot-switch and hand-switch triggered FES correction of foot drop. Proceedings of the 6th Vienna Inter- national Workshop on Functional Electrostimulation, Vienna, Austria."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1007\/s11517-009-0545-x","article-title":"\u2018Outwalk\u2019: A protocol for clinical gait analysis based on inertial and magnetic sensors","volume":"48","author":"Cutti","year":"2010","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1109\/TNSRE.2007.891391","article-title":"The Optimal Controller Delay for Myoelectric Prostheses","volume":"15","author":"Farrell","year":"2007","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1109\/TOH.2013.50","article-title":"Human Detection and Discrimination of Tactile Repeatability, Mechanical Backlash, and Temporal Delay in a Combined Tactile-Kinesthetic Haptic Display System","volume":"6","author":"Doxon","year":"2013","journal-title":"IEEE Trans. Haptics"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1940","DOI":"10.1109\/TBME.2007.901024","article-title":"OpenSim: Open-source software to create and analyze dynamic simulations of movement","volume":"54","author":"Delp","year":"2007","journal-title":"IEEE Trans. Bio-Med. Eng."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"2709","DOI":"10.1016\/j.jbiomech.2010.06.025","article-title":"Muscle contributions to propulsion and support during running","volume":"43","author":"Hamner","year":"2010","journal-title":"J. Biomech."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"3390","DOI":"10.1016\/j.jbiomech.2008.09.035","article-title":"Kalman smoothing improves the estimation of joint kinematics and kinetics in marker-based human gait analysis","volume":"41","author":"Jonkers","year":"2008","journal-title":"J. Biomech."},{"key":"ref_21","unstructured":"Chia Bejarano, N., Lambrecht, S., Urendes, E., Moreno, J.C., Ambrosini, E., Ferrante, S., and Pons, J.L. (2014, January 14\u201319). Real-time detection of gait and stance events from WR embedded sensors. Proceedings of the 1st International Workshop on Wearable Robotics (WeRob), Baiona, Spain."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"1","author":"Bland","year":"1986","journal-title":"Lancet"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/4\/671\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T18:31:11Z","timestamp":1760207471000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/4\/671"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,3,24]]},"references-count":22,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2017,4]]}},"alternative-id":["s17040671"],"URL":"https:\/\/doi.org\/10.3390\/s17040671","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,3,24]]}}}