{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T12:04:04Z","timestamp":1777377844404,"version":"3.51.4"},"reference-count":53,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2017,5,4]],"date-time":"2017-05-04T00:00:00Z","timestamp":1493856000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The article describes the results of the project \u201copen source smart lamp\u201d aimed at designing and developing a smart object able to manage and control the indoor environmental quality (IEQ) of the built environment. A first version of this smart object, built following a do-it-yourself (DIY) approach using a microcontroller, an integrated temperature and relative humidity sensor, and techniques of additive manufacturing, allows the adjustment of the indoor thermal comfort quality (ICQ), by interacting directly with the air conditioner. As is well known, the IEQ is a holistic concept including indoor air quality (IAQ), indoor lighting quality (ILQ) and acoustic comfort, besides thermal comfort. The upgrade of the smart lamp bridges the gap of the first version of the device providing the possibility of interaction with the air exchange unit and lighting system in order to get an overview of the potential of a nearable device in the management of the IEQ. The upgraded version was tested in a real office equipped with mechanical ventilation and an air conditioning system. This office was occupied by four workers. The experiment is compared with a baseline scenario and the results show how the application of the nearable device effectively optimizes both IAQ and ILQ.<\/jats:p>","DOI":"10.3390\/s17051021","type":"journal-article","created":{"date-parts":[[2017,5,4]],"date-time":"2017-05-04T11:44:18Z","timestamp":1493898258000},"page":"1021","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":72,"title":["Design and Development of a Nearable Wireless System to Control Indoor Air Quality and Indoor Lighting Quality"],"prefix":"10.3390","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3215-3979","authenticated-orcid":false,"given":"Francesco","family":"Salamone","sequence":"first","affiliation":[{"name":"ITC-CNR, Construction Technologies Institute\u2014National Research Council of Italy, Via Lombardia 49-20098 San Giuliano M.se, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1341-0602","authenticated-orcid":false,"given":"Lorenzo","family":"Belussi","sequence":"additional","affiliation":[{"name":"ITC-CNR, Construction Technologies Institute\u2014National Research Council of Italy, Via Lombardia 49-20098 San Giuliano M.se, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ludovico","family":"Danza","sequence":"additional","affiliation":[{"name":"ITC-CNR, Construction Technologies Institute\u2014National Research Council of Italy, Via Lombardia 49-20098 San Giuliano M.se, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Theodore","family":"Galanos","sequence":"additional","affiliation":[{"name":"NEAPOLI SDN BHD 894646-M Environmental Design and Engineering, D-8-5, Megan Avenue 1, 189 Jalan Tun Razak, 50400 Kuala Lumpur, Malaysia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matteo","family":"Ghellere","sequence":"additional","affiliation":[{"name":"ITC-CNR, Construction Technologies Institute\u2014National Research Council of Italy, Via Lombardia 49-20098 San Giuliano M.se, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Italo","family":"Meroni","sequence":"additional","affiliation":[{"name":"ITC-CNR, Construction Technologies Institute\u2014National Research Council of Italy, Via Lombardia 49-20098 San Giuliano M.se, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2017,5,4]]},"reference":[{"key":"ref_1","unstructured":"(2017, April 18). Nearable Definition. Available online: https:\/\/en.wikipedia.org\/wiki\/Nearables#cite_note-1."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1016\/S0306-2619(03)00059-X","article-title":"Towards sustainable-energy buildings","volume":"76","author":"Chwieduk","year":"2003","journal-title":"Appl. Energy"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1016\/j.procir.2014.01.059","article-title":"A semantic framework for sustainable factories","volume":"17","author":"Terkaj","year":"2014","journal-title":"Procedia CIRP"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1080\/16864360.2014.962432","article-title":"An ontology-based framework for sustainable factories","volume":"12","author":"Gagliardo","year":"2015","journal-title":"Comput. Aided Des. Appl."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Danza, L., Belussi, L., Meroni, I., Mililli, M., and Salamone, F. (2016). Hourly calculation method of air source heat pump behavior. Buildings, 6.","DOI":"10.3390\/buildings6020016"},{"key":"ref_6","unstructured":"Belussi, L., Danza, L., Meroni, I., Salamone, F., Ragazzi, F., and Mililli, M. (2014). Energy Performance of Buildings: A Study of the Differences between Assessment Methods. Energy Consumption: Impacts of Human Activity, Current and Future Challenges, Environmental and Socio-Economic Effects, University of Liege, Architecture and Urban Planning."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1515\/oere-2015-0008","article-title":"Energy performance assessment with empirical methods: Application of energy signature","volume":"23","author":"Belussi","year":"2015","journal-title":"Opto-Electron. Rev."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1016\/j.egypro.2016.11.013","article-title":"A Simplified Thermal Model to Control the Energy Fluxes and to Improve the Performance of Buildings","volume":"101","author":"Danza","year":"2016","journal-title":"Energy Procedia"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Danza, L., Barozzi, B., Belussi, L., Meroni, I., and Salamone, F. (2016). Assessment of the performance of a ventilated window coupled with a heat recovery unit through the co-heating test. Buildings, 6.","DOI":"10.3390\/buildings6010003"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Pasini, D., Ventura, S.M., Rinaldi, S., Bellagente, P., Flammini, A., and Ciribini, A.L.C. (2016, January 12\u201315). Exploiting Internet of Things and building information modeling framework for management of cognitive buildings. Proceedings of the 2016 IEEE International Smart Cities Conference (ISC2), Trento, Italy.","DOI":"10.1109\/ISC2.2016.7580817"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1645","DOI":"10.1016\/j.future.2013.01.010","article-title":"Internet of Things (IoT): A vision, architectural elements, and future directions","volume":"29","author":"Gubbi","year":"2013","journal-title":"Future Gener. Comput. Syst."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Mej\u00edas, A., Herrera, R.S., M\u00e1rquez, M.A., Calder\u00f3n, A.J., Gonz\u00e1lez, I., and And\u00fajar, J.M. (2017). Easy Handling of Sensors and Actuators over TCP\/IP Networks by Open Source Hardware\/Software. Sensors, 17.","DOI":"10.3390\/s17010094"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1016\/j.chb.2016.08.009","article-title":"Preference for multitasking, technological dependency, student metacognition & pervasive technology use: An experimental intervention","volume":"65","author":"Terry","year":"2016","journal-title":"Comput. Hum. Behav."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.egypro.2016.11.021","article-title":"Integration of a do it yourself Hardware in a Lighting Device for the Management of Thermal Comfort and Energy Use","volume":"101","author":"Salamone","year":"2016","journal-title":"Energy Procedia"},{"key":"ref_15","first-page":"5","article-title":"Occupancy Estimation in Smart Building Using Hybrid CO2\/Light Wireless Sensor Network","volume":"1","author":"Huang","year":"2017","journal-title":"J. Appl. Sci. Arts"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1260\/1351-010X.22.2.123","article-title":"Improvement of Fa\u00e7ades Sound Insulation of Schools near the Bergamo-Orio al Serio International Airport: Case Study","volume":"22","author":"Torchia","year":"2015","journal-title":"Build. Acoust."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1177\/1351010X16670173","article-title":"Correlation between facade sound insulation and urban noise: A contribution to the acoustic classification of existing buildings","volume":"23","author":"Casini","year":"2016","journal-title":"Build. Acoust."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Salamone, F., Belussi, L., Danza, L., Ghellere, M., and Meroni, I. (2016). An Open Source \u201cSmart Lamp\u201d for the Optimization of Plant Systems and Thermal Comfort of Offices. Sensors, 16.","DOI":"10.3390\/s16030338"},{"key":"ref_19","unstructured":"(2017, April 18). Construction Technologies Institute of the National Research Council of Italy (ITC-CNR). Available online: http:\/\/www.itc.cnr.it\/."},{"key":"ref_20","unstructured":"Anderson, C. (2010). The New Industrial Revolution, Crown Business."},{"key":"ref_21","unstructured":"(2017, April 18). How to Make Almost Anything. Available online: http:\/\/cba.mit.edu\/docs\/papers\/12.09.FA.pdf."},{"key":"ref_22","unstructured":"Hatch, M. (2014). The Maker Movement Manifesto, McGraw-Hill Education."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"13012","DOI":"10.3390\/s150613012","article-title":"Design and Development of nEMoS, an All-in-One, Low-Cost, Web-Connected and 3D-Printed Device for Environmental Analysis","volume":"15","author":"Salamone","year":"2015","journal-title":"Sensors"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/j.measurement.2016.06.014","article-title":"Internet of Things Cloud Enabled MISSENARD Index Measurement for Indoor Occupants","volume":"96","author":"Ray","year":"2016","journal-title":"Measurement"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"27990","DOI":"10.3390\/s151127990","article-title":"An Open Source Low-Cost Wireless Control System for a Forced Circulation Solar Plant","volume":"15","author":"Salamone","year":"2015","journal-title":"Sensors"},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Mor\u00f3n, C., D\u00edaz, J.P., Ferr\u00e1ndez, D., and Ramos, M.P. (2016). Mechatronic Prototype of Parabolic Solar Tracker. Sensors, 16.","DOI":"10.3390\/s16060882"},{"key":"ref_27","unstructured":"(2017, April 18). oDocs Eye Care. Available online: http:\/\/www.odocs-tech.com\/."},{"key":"ref_28","unstructured":"(2017, April 18). OBM\u2014Open BioMedical Initiative. Available online: http:\/\/www.openbiomedical.org\/."},{"key":"ref_29","unstructured":"(2017, April 18). Arduino UNO r3 Datasheet. Available online: https:\/\/www.arduino.cc\/en\/Main\/ArduinoBoardUno."},{"key":"ref_30","unstructured":"(2017, April 18). Wireless SD Shield datasheet. Available online: https:\/\/www.arduino.cc\/en\/Main\/ArduinoWirelessShield."},{"key":"ref_31","unstructured":"(2017, April 18). XBee S2 Module Datasheet. Available online: https:\/\/cdn.sparkfun.com\/datasheets\/Wireless\/Zigbee\/ds_xbeezbmodules.pdf."},{"key":"ref_32","unstructured":"(2017, April 18). RTC Module Based on DS1307 Chip, Datasheet. Available online: https:\/\/cdn.sparkfun.com\/datasheets\/BreakoutBoards\/DS1307.pdf."},{"key":"ref_33","unstructured":"(2017, April 18). K30-CO2 Concentration Sensor, Datasheet. Available online: http:\/\/co2meters.com\/Documentation\/Datasheets\/DS30-01%20-%20K30.pdf."},{"key":"ref_34","unstructured":"(2017, April 18). External Wall as Defined by Input Output Reference\u2014EnergyPlus. Available online: http:\/\/bigladdersoftware.com\/epx\/docs\/8-2\/input-output-reference\/group-thermal-zone-description-geometry.html#wallexterior."},{"key":"ref_35","unstructured":"(2017, April 18). Adiabatic Wall as Defined by Input Output Reference\u2014EnergyPlus. Available online: http:\/\/bigladdersoftware.com\/epx\/docs\/8-2\/input-output-reference\/group-thermal-zone-description-geometry.html#walladiabatic."},{"key":"ref_36","unstructured":"(2017, April 18). Adiabatic Floor as Defined by Input Output Reference\u2014EnergyPlus. Available online: http:\/\/bigladdersoftware.com\/epx\/docs\/8-2\/input-output-reference\/group-thermal-zone-description-geometry.html#flooradiabatic."},{"key":"ref_37","unstructured":"(2017, April 18). Roof as Defined by Input Output Reference\u2014EnergyPlus. Available online: http:\/\/bigladdersoftware.com\/epx\/docs\/8-2\/input-output-reference\/group-thermal-zone-description-geometry.html#roof."},{"key":"ref_38","unstructured":"(2017, April 18). 2-Channel Relay Module Datasheet. Available online: http:\/\/www.microbot.it\/documents\/mr009-004_datasheet.pdf."},{"key":"ref_39","unstructured":"(2017, April 18). 5V\/3.3V Power Supply Module. Available online: http:\/\/www.dfrobot.com\/index.php?route=product\/product&product_id=488#.V5C9q9KLSUk."},{"key":"ref_40","unstructured":"Faludi, R. (2010). Building Wireless Sensor Networks: With ZigBee, XBee, arduino, and Processing, O\u2019Reilly Media, Inc."},{"key":"ref_41","unstructured":"Alliance, Z. (2017, April 18). IEEE 802.15. 4, ZigBee Standard. Available online: http:\/\/www.zigbee.org."},{"key":"ref_42","doi-asserted-by":"crossref","unstructured":"Liu, X., Chen, H., Wang, M., and Chen, S. (2012, January 7\u20139). An XBee-Pro Based Energy Monitoring System. Proceedings of the 2012 Australasian Telecommunication Networks and Applications Conference (ATNAC), Brisbane, Australia.","DOI":"10.1109\/ATNAC.2012.6398052"},{"key":"ref_43","unstructured":"(2017, April 18). UNI 10339:1995. Available online: http:\/\/store.uni.com\/magento-1.4.0.1\/index.php\/uni-10339-1995.html."},{"key":"ref_44","unstructured":"Roudsari, M.S., Pak, M., and Smith, A. (2013, January 25\u201330). Ladybug: A parametric environmental plugin for grasshopper to help designers create an environmentally-conscious design. Proceedings of the 13th International IBPSA Conference, Lyon, France."},{"key":"ref_45","unstructured":"(2017, April 18). OpenFoam Site. Available online: http:\/\/www.openfoam.com\/."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"2378","DOI":"10.1016\/j.buildenv.2009.03.025","article-title":"Interactions with window openings by office occupants","volume":"44","author":"Haldi","year":"2009","journal-title":"Build. Environ."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"588","DOI":"10.1016\/j.buildenv.2006.06.031","article-title":"Towards a model of user behaviour regarding the manual control of windows in office buildings","volume":"43","author":"Herkel","year":"2008","journal-title":"Build. Environ."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1177\/1420326X13508566","article-title":"On-site measurements of ventilation performance and indoor air quality in naturally ventilated high-rise residential buildings in Hong Kong","volume":"24","author":"Ai","year":"2013","journal-title":"Indoor Built Environ."},{"key":"ref_49","unstructured":"(2017, April 18). EN 15251:2008. Available online: http:\/\/store.uni.com\/magento-1.4.0.1\/index.php\/uni-en-15251-2008.html."},{"key":"ref_50","unstructured":"(2017, April 18). UNI EN 12464-1:2011. Available online: http:\/\/store.uni.com\/magento-1.4.0.1\/index.php\/uni-en-12464-1-2011.html."},{"key":"ref_51","unstructured":"(2017, April 18). Grasshopper, Graphical Algorithm Editor. Available online: http:\/\/www.grasshopper3d.com\/."},{"key":"ref_52","unstructured":"(2017, April 18). TTToolbox Plugin. Available online: http:\/\/www.food4rhino.com\/project\/tttoolbox?etx."},{"key":"ref_53","unstructured":"(2017, April 18). RIGERS Project. Available online: http:\/\/www.urbancenterbologna.it\/images\/2017_03_03_BolognaCittaResiliente\/Tavolo_Servizi\/BO-Resiliente_RIGERS1.pdf."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/5\/1021\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T18:34:38Z","timestamp":1760207678000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/5\/1021"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,5,4]]},"references-count":53,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2017,5]]}},"alternative-id":["s17051021"],"URL":"https:\/\/doi.org\/10.3390\/s17051021","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,5,4]]}}}