{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,18]],"date-time":"2026-01-18T09:49:28Z","timestamp":1768729768150,"version":"3.49.0"},"reference-count":47,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2017,5,30]],"date-time":"2017-05-30T00:00:00Z","timestamp":1496102400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Currently, Cystic Fibrosis (CF) patients lack the ability to track their lung health at home, relying instead on doctor checkups leading to delayed treatment and lung damage. By leveraging the ubiquity of the smartphone to lower costs and increase portability, a smartphone-based peripheral pH measurement device was designed to attach directly to the headphone port to harvest power and communicate with a smartphone application. This platform was tested using prepared pH buffers and sputum samples from CF patients. The system matches within ~0.03 pH of a benchtop pH meter while fully powering itself and communicating with a Samsung Galaxy S3 smartphone paired with either a glass or Iridium Oxide (IrOx) electrode. The IrOx electrodes were found to have 25% higher sensitivity than the glass probes at the expense of larger drift and matrix sensitivity that can be addressed with proper calibration. The smartphone-based platform has been demonstrated as a portable replacement for laboratory pH meters, and supports both highly robust glass probes and the sensitive and miniature IrOx electrodes with calibration. This tool can enable more frequent pH sputum tracking for CF patients to help detect the onset of pulmonary exacerbation to provide timely and appropriate treatment before serious damage occurs.<\/jats:p>","DOI":"10.3390\/s17061245","type":"journal-article","created":{"date-parts":[[2017,5,30]],"date-time":"2017-05-30T10:26:55Z","timestamp":1496140015000},"page":"1245","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Smartphone-Based pH Sensor for Home Monitoring of Pulmonary Exacerbations in Cystic Fibrosis"],"prefix":"10.3390","volume":"17","author":[{"given":"Alexander","family":"Sun","sequence":"first","affiliation":[{"name":"Department of Electrical and Computer Engineering, University of California, San Diego, La Jolla, CA 92093, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tom","family":"Phelps","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering, University of California, San Diego, La Jolla, CA 92093, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chengyang","family":"Yao","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering, University of California, San Diego, La Jolla, CA 92093, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Venkatesh","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering, University of California, San Diego, La Jolla, CA 92093, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Douglas","family":"Conrad","sequence":"additional","affiliation":[{"name":"Department of Medicine, University of California, San Diego, La Jolla, CA 92093, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0674-074X","authenticated-orcid":false,"given":"Drew","family":"Hall","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering, University of California, San Diego, La Jolla, CA 92093, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2017,5,30]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1038\/nrg3849","article-title":"Cystic fibrosis genetics: From molecular understanding to clinical application","volume":"16","author":"Cutting","year":"2015","journal-title":"Nat. Rev. Genet."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"566","DOI":"10.1542\/peds.2009-2791","article-title":"Cystic Fibrosis and Transition to Adult Medical Care","volume":"125","author":"Tuchman","year":"2010","journal-title":"Pediatrics"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1056\/NEJMra1300109","article-title":"Origins of Cystic Fibrosis Lung Disease","volume":"372","author":"Stoltz","year":"2015","journal-title":"N. Engl. J. Med."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"3999","DOI":"10.1039\/C4AN00675E","article-title":"Electrochemistry provides a point-of-care approach for the marker indicative of Pseudomonas aeruginosa infection of cystic fibrosis patients","volume":"139","author":"Metters","year":"2014","journal-title":"Analyst"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1016\/j.cyto.2010.02.004","article-title":"Sputum biomarker profiles in cystic fibrosis (CF) and chronic obstructive pulmonary disease (COPD) and association between pulmonary function","volume":"50","author":"Eickmeier","year":"2010","journal-title":"Cytokine"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"8148","DOI":"10.4049\/jimmunol.0901716","article-title":"Decreased Levels of Secretory Leucoprotease Inhibitor in the Pseudomonas-Infected Cystic Fibrosis Lung Are Due to Neutrophil Elastase Degradation","volume":"183","author":"Weldon","year":"2009","journal-title":"J. Immunol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"822","DOI":"10.1164\/rccm.200609-1354OC","article-title":"Association between Pulmonary Function and Sputum Biomarkers in Cystic Fibrosis","volume":"175","author":"Aitken","year":"2007","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1136\/thx.2003.017327","article-title":"Exhaled breath condensate pH and exhaled nitric oxide in allergic asthma and in cystic fibrosis","volume":"60","author":"Ojoo","year":"2005","journal-title":"Thorax"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"2005","DOI":"10.1378\/chest.125.6.2005","article-title":"Breath condensate pH in children with cystic fibrosis and asthma*: A new noninvasive marker of airway inflammation?","volume":"125","author":"Carpagnano","year":"2004","journal-title":"Chest"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1279","DOI":"10.1007\/s11136-011-0091-5","article-title":"Erratum to: Psychometric evaluation of the Cystic Fibrosis Questionnaire-Revised in a national, US sample","volume":"21","author":"Quittner","year":"2012","journal-title":"Qual. Life Res."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1610","DOI":"10.1378\/chest.08-1190","article-title":"DEtermination of the minimal clinically important difference scores for the cystic fibrosis questionnaire-revised respiratory symptom scale in two populations of patients with cystic fibrosis and chronic pseudomonas aeruginosa airway infection","volume":"135","author":"Quittner","year":"2009","journal-title":"Chest"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"370","DOI":"10.1097\/00008483-200511000-00011","article-title":"Minimal clinically important difference for the UCSD Shortness of Breath Questionnaire","volume":"25","author":"Kupferberg","year":"2005","journal-title":"J. Cardpulm. Rehabil."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1378\/chest.113.3.619","article-title":"Validation of a new dyspnea measure: The ucsd shortness of breath questionnaire","volume":"113","author":"Eakin","year":"1998","journal-title":"Chest"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"474","DOI":"10.1016\/j.snb.2015.11.080","article-title":"Chromogenic device for cystic fibrosis precocious diagnosis: A \u201cpoint of care\u201d tool for sweat test","volume":"225","author":"Cannavale","year":"2016","journal-title":"Sens. Actuators B Chem."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1788","DOI":"10.1016\/j.bios.2008.07.051","article-title":"Early determination of cystic fibrosis by electrochemical chloride quantification in sweat","volume":"24","author":"Mas","year":"2009","journal-title":"Biosens. Bioelectron."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1245","DOI":"10.1016\/j.bios.2010.06.047","article-title":"Impedimetric genosensing of DNA polymorphism correlated to cystic fibrosis: A comparison among different protocols and electrode surfaces","volume":"26","author":"Bonanni","year":"2010","journal-title":"Biosens. Bioelectron."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1049\/ip-cds:20050022","article-title":"Magnetic biosensors for genetic screening of cystic fibrosis","volume":"152","author":"Lagae","year":"2005","journal-title":"IEE Proc. Circuits Devices Syst."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1007\/s00604-015-1660-z","article-title":"Screening for cystic fibrosis via a magnetic and microfluidic immunoassay format with electrochemical detection using a copper nanoparticle-modified gold electrode","volume":"183","author":"Benuzzi","year":"2016","journal-title":"Microchim. Acta"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1699","DOI":"10.1021\/acsnano.5b07939","article-title":"A Digital\u2013Analog Microfluidic Platform for Patient-Centric Multiplexed Biomarker Diagnostics of Ultralow Volume Samples","volume":"10","author":"Piraino","year":"2016","journal-title":"ACS Nano"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1016\/j.snb.2012.02.010","article-title":"Concept and development of an autonomous wearable micro-fluidic platform for real time pH sweat analysis","volume":"175","author":"Curto","year":"2012","journal-title":"Sens. Actuators B Chem."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1725","DOI":"10.1039\/C3LC51451J","article-title":"Development of the smartphone-based colorimetry for multi-analyte sensing arrays","volume":"14","author":"Hong","year":"2014","journal-title":"Lab Chip"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"4240","DOI":"10.1039\/c2lc40741h","article-title":"Point-of-care colorimetric detection with a smartphone","volume":"12","author":"Shen","year":"2012","journal-title":"Lab Chip"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1327","DOI":"10.1016\/j.snb.2012.06.048","article-title":"Real-time sweat pH monitoring based on a wearable chemical barcode micro-fluidic platform incorporating ionic liquids","volume":"171\u2013172","author":"Curto","year":"2012","journal-title":"Sens. Actuators B Chem."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1016\/j.snb.2015.05.088","article-title":"Simultaneous color sensing of O2 and pH using a smartphone","volume":"220","author":"Xu","year":"2015","journal-title":"Sens. Actuators B Chem."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"3232","DOI":"10.1039\/c3lc50431j","article-title":"Smartphone based health accessory for colorimetric detection of biomarkers in sweat and saliva","volume":"13","author":"Oncescu","year":"2013","journal-title":"Lab Chip"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1039\/C2AN36422K","article-title":"Tattoo-based potentiometric ion-selective sensors for epidermal pH monitoring","volume":"138","author":"Bandodkar","year":"2012","journal-title":"Analyst"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"11984","DOI":"10.1073\/pnas.1405679111","article-title":"Universal mobile electrochemical detector designed for use in resource-limited applications","volume":"111","author":"Nemiroski","year":"2014","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1016\/j.aca.2010.08.035","article-title":"Recent trends in potentiometric sensor arrays\u2014A review","volume":"678","author":"Bratov","year":"2010","journal-title":"Anal. Chim. Acta"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1109\/JSEN.2007.912522","article-title":"Review Paper: Materials and Techniques for In Vivo pH Monitoring","volume":"8","author":"Korostynska","year":"2008","journal-title":"IEEE Sens. J."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"3027","DOI":"10.3390\/s7123027","article-title":"Review on State-of-the-art in Polymer Based pH Sensors","volume":"7","author":"Korostynska","year":"2007","journal-title":"Sensors"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jbbm.2005.02.001","article-title":"New technology for the detection of pH","volume":"63","author":"Yuqing","year":"2005","journal-title":"J. Biochem. Biophys. Methods"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1016\/S0925-4005(01)00972-8","article-title":"A long-term stable iridium oxide pH electrode","volume":"81","author":"Wang","year":"2002","journal-title":"Sens. Actuators B Chem."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"5054","DOI":"10.1021\/ac980608e","article-title":"Electrodeposited iridium oxide pH electrode for measurement of extracellular myocardial acidosis during acute ischemia","volume":"70","author":"Marzouk","year":"1998","journal-title":"Anal. Chem."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/S0022-0728(84)80045-5","article-title":"Preparation of an oxidized iridium electrode and the variation of its potential with pH","volume":"163","author":"Burke","year":"1984","journal-title":"J. Electroanal. Chem. Interfacial Electrochem."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"12233","DOI":"10.1016\/j.polymer.2005.10.095","article-title":"Potentiometric pH sensors based on electrodeposited polymers","volume":"46","author":"Lakard","year":"2005","journal-title":"Polymer"},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Kuo, Y.-S., Schmid, T., and Dutta, P. (2010, January 17\u201318). Hijacking power and bandwidth from the mobile phone\u2019s audio interface. Proceedings of the First ACM Annual Symposium on Computing for Development, London, UK.","DOI":"10.1145\/1926180.1926210"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"273re1","DOI":"10.1126\/scitranslmed.aaa0056","article-title":"A smartphone dongle for diagnosis of infectious diseases at the point of care","volume":"7","author":"Laksanasopin","year":"2015","journal-title":"Sci. Transl. Med."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1016\/j.snb.2014.12.017","article-title":"Audio jack based miniaturized mobile phone electrochemical sensing platform","volume":"209","author":"Wang","year":"2015","journal-title":"Sens. Actuators B Chem."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"994","DOI":"10.1016\/j.snb.2015.09.041","article-title":"Protein detecting with smartphone-controlled electrochemical impedance spectroscopy for point-of-care applications","volume":"222","author":"Zhang","year":"2016","journal-title":"Sens. Actuators B Chem."},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Yao, C., Sun, A., and Hall, D.A. (2015, January 8\u201311). Efficient Power Harvesting from the Mobile Phone Audio Jack for mHealth Peripherals. Proceedings of the 2015 IEEE Global Humanitarian Technology Conference (GHTC), Seattle, WA, USA.","DOI":"10.1109\/GHTC.2015.7343976"},{"key":"ref_41","doi-asserted-by":"crossref","unstructured":"Sun, A., Wambach, T., Venkatesh, A.G., and Hall, D.A. (2014, January 22\u201324). A low-cost smartphone-based electrochemical biosensor for point-of-care diagnostics. Proceedings of the 2014 IEEE Biomedical Circuits and Systems Conference (BioCAS), Lausanne, Switzerland.","DOI":"10.1109\/BioCAS.2014.6981725"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/j.snb.2016.05.010","article-title":"An efficient power harvesting mobile phone-based electrochemical biosensor for point-of-care health monitoring","volume":"235","author":"Sun","year":"2016","journal-title":"Sens. Actuators B Chem."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"H29","DOI":"10.1149\/1.1353582","article-title":"A pH Electrode Based on Melt-Oxidized Iridium Oxide","volume":"148","author":"Yao","year":"2001","journal-title":"J. Electrochem. Soc."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1016\/0014-4886(86)90132-9","article-title":"Histopathologic evaluation of prolonged intracortical electrical stimulation","volume":"92","author":"Agnew","year":"1986","journal-title":"Exp. Neurol."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1016\/S0928-4931(02)00098-X","article-title":"Electrochemical and structural characterizations of electrodeposited iridium oxide thin-film electrodes applied to neurostimulating electrical signal","volume":"21","author":"Mailley","year":"2002","journal-title":"Mater. Sci. Eng. C"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/j.sna.2010.09.016","article-title":"New dry electrodes based on iridium oxide (IrO) for non-invasive biopotential recordings and stimulation","volume":"164","author":"Dias","year":"2010","journal-title":"Sens. Actuators Phys. A"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"1055","DOI":"10.1016\/j.biomaterials.2009.10.029","article-title":"Neuronal cell growth on iridium oxide","volume":"31","author":"Kuenzel","year":"2010","journal-title":"Biomaterials"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/6\/1245\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T18:37:23Z","timestamp":1760207843000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/6\/1245"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,5,30]]},"references-count":47,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2017,6]]}},"alternative-id":["s17061245"],"URL":"https:\/\/doi.org\/10.3390\/s17061245","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,5,30]]}}}