{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,6]],"date-time":"2026-01-06T05:05:04Z","timestamp":1767675904235,"version":"build-2065373602"},"reference-count":37,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2017,6,12]],"date-time":"2017-06-12T00:00:00Z","timestamp":1497225600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Spanish Government","award":["DPI-2013-46982-C2-2-R","DPI-2016-78831-C2-2-R"],"award-info":[{"award-number":["DPI-2013-46982-C2-2-R","DPI-2016-78831-C2-2-R"]}]},{"name":"National Council of Technological and Scientific Development, CNPq - Brazil","award":["202050\/2015-7"],"award-info":[{"award-number":["202050\/2015-7"]}]},{"DOI":"10.13039\/100008722","name":"University of Girona","doi-asserted-by":"publisher","award":["BR2014\/51"],"award-info":[{"award-number":["BR2014\/51"]}],"id":[{"id":"10.13039\/100008722","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Agency for Management of University and Research Grants of the Government of Catalonia, Spain","award":["Beatriu de Pin\u00f3s [BP-DGR 2013]"],"award-info":[{"award-number":["Beatriu de Pin\u00f3s [BP-DGR 2013]"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Continuous glucose monitors (CGMs) are prone to inaccuracy due to time lags, sensor drift, calibration errors, and measurement noise. The aim of this study is to derive the model of the error of the second generation Medtronic Paradigm Veo Enlite (ENL) sensor and compare it with the Dexcom SEVEN PLUS (7P), G4 PLATINUM (G4P), and advanced G4 for Artificial Pancreas studies (G4AP) systems. An enhanced methodology to a previously employed technique was utilized to dissect the sensor error into several components. The dataset used included 37 inpatient sessions in 10 subjects with type 1 diabetes (T1D), in which CGMs were worn in parallel and blood glucose (BG) samples were analyzed every 15 \u00b1 5 min Calibration error and sensor drift of the ENL sensor was best described by a linear relationship related to the gain and offset. The mean time lag estimated by the model is 9.4 \u00b1 6.5 min. The overall average mean absolute relative difference (MARD) of the ENL sensor was 11.68 \u00b1 5.07% Calibration error had the highest contribution to total error in the ENL sensor. This was also reported in the 7P, G4P, and G4AP. The model of the ENL sensor error will be useful to test the in silico performance of CGM-based applications, i.e., the artificial pancreas, employing this kind of sensor.<\/jats:p>","DOI":"10.3390\/s17061361","type":"journal-article","created":{"date-parts":[[2017,6,12]],"date-time":"2017-06-12T10:27:59Z","timestamp":1497263279000},"page":"1361","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Modeling the Error of the Medtronic Paradigm Veo Enlite Glucose Sensor"],"prefix":"10.3390","volume":"17","author":[{"given":"Lyvia","family":"Biagi","sequence":"first","affiliation":[{"name":"Institut d\u2019Inform\u00e0tica i Aplicacions, Universitat de Girona, Campus de Montilivi, s\/n, Edifici P4, 17071 Girona, Spain"},{"name":"Federal University of Technology\u2014Paran\u00e1, 85053-252 Guarapuava, Brazil"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2868-2918","authenticated-orcid":false,"given":"Charrise","family":"Ramkissoon","sequence":"additional","affiliation":[{"name":"Institut d\u2019Inform\u00e0tica i Aplicacions, Universitat de Girona, Campus de Montilivi, s\/n, Edifici P4, 17071 Girona, Spain"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8041-2280","authenticated-orcid":false,"given":"Andrea","family":"Facchinetti","sequence":"additional","affiliation":[{"name":"Department of Information Engineering, University of Padova, 35131 Padova, Italy"}]},{"given":"Yenny","family":"Leal","sequence":"additional","affiliation":[{"name":"Service of Diabetes, Endocrinology and Nutrition (UDEN), Institut d\u2019Investigaci\u00f3 Biom\u00e9dica de Girona (IdIBGi), Avinguda de Fran\u00e7a s\/n, 17007 Girona, Spain"},{"name":"CIBER Pathophysiology of Obesity and Nutrition, Instituto de Salud Carlos III, 28029 Madrid, Spain"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6884-9789","authenticated-orcid":false,"given":"Josep","family":"Vehi","sequence":"additional","affiliation":[{"name":"Institut d\u2019Inform\u00e0tica i Aplicacions, Universitat de Girona, Campus de Montilivi, s\/n, Edifici P4, 17071 Girona, Spain"}]}],"member":"1968","published-online":{"date-parts":[[2017,6,12]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"S35","DOI":"10.1089\/15209150050214104","article-title":"Clinical utility of the continuous glucose monitoring system","volume":"2","author":"Bode","year":"2000","journal-title":"Diabetes Technol. Ther."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"2672","DOI":"10.2337\/db11-0654","article-title":"Artificial Pancreas: Past, Present, Future","volume":"60","author":"Cobelli","year":"2011","journal-title":"Diabetes"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1089\/15209150050214078","article-title":"The MiniMed Continuous Glucose Monitoring System","volume":"2","author":"Mastrototaro","year":"2000","journal-title":"Diabetes Technol. Ther."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1111\/nyas.12431","article-title":"The artificial pancreas: Current status and future prospects in the management of diabetes","volume":"1311","author":"Peyser","year":"2014","journal-title":"Ann. N. Y. Acad. Sci."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"769","DOI":"10.1089\/152091503322526978","article-title":"A Continuous Glucose Sensor Based on Wired Enzyme\u2122 Technology\u2014Results from a 3-Day Trial in Patients with Type 1 Diabetes","volume":"5","author":"Feldman","year":"2003","journal-title":"Diabetes Technol. Ther."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1089\/dia.2009.0158","article-title":"Enhanced Accuracy of Continuous Glucose Monitoring by Online Extended Kalman Filtering","volume":"12","author":"Facchinetti","year":"2010","journal-title":"Diabetes Technol. Ther."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1109\/TBME.2013.2284023","article-title":"Modeling the Glucose Sensor Error","volume":"61","author":"Facchinetti","year":"2014","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1259","DOI":"10.1007\/s11517-014-1226-y","article-title":"Model of glucose sensor error components: Identification and assessment for new Dexcom G4 generation devices","volume":"53","author":"Facchinetti","year":"2015","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"5996","DOI":"10.3390\/s120505996","article-title":"A Critical Review of Glucose Biosensors Based on Carbon Nanomaterials: Carbon Nanotubes and Graphene","volume":"12","author":"Zhu","year":"2012","journal-title":"Sensors"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1177\/193229680700100302","article-title":"Modeling of Calibration Effectiveness and Blood-to-Interstitial Glucose Dynamics as Potential Confounders of the Accuracy of Continuous Glucose Sensors during Hyperinsulinemic Clamp","volume":"1","author":"King","year":"2007","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_11","unstructured":"Kovatchev, B.P., King, C., Breton, M., and Anderson, S. (September, January 31). Clinical Assessment and Mathematical Modeling of the Accuracy of Continuous Glucose Sensors (CGS). Proceedings of the 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, New York, NY, USA."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1177\/1932296813514502","article-title":"The UVA\/PADOVA Type 1 Diabetes Simulator: New Features","volume":"8","author":"Micheletto","year":"2014","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Facchinetti, A. (2016). Continuous Glucose Monitoring Sensors: Past, Present and Future Algorithmic Challenges. Sensors, 16.","DOI":"10.3390\/s16122093"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"(2016). FDA Advisory Panel Votes to Recommend Non-Adjunctive Use of Dexcom G5 Mobile CGM. Diabetes Technol. Ther., 18, 512\u2013516.","DOI":"10.1089\/dia.2016.07252.mr"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Edelman, S.V. (2016). Regulation Catches Up to Reality: Nonadjunctive Use of Continuous Glucose Monitoring Data. J. Diabetes Sci. Technol., 1\u20135.","DOI":"10.1177\/1932296816667749"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1177\/193229680800200517","article-title":"Analysis, modeling, and simulation of the accuracy of continuous glucose sensors","volume":"2","author":"Breton","year":"2008","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1177\/193229681000400102","article-title":"Modeling the error of continuous glucose monitoring sensor data: Critical aspects discussed through simulation studies","volume":"4","author":"Facchinetti","year":"2010","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1016\/j.bspc.2012.12.003","article-title":"Postprandial performance of Dexcom SEVEN PLUS and Medtronic Paradigm Veo: Modeling and statistical analysis","volume":"10","author":"Laguna","year":"2014","journal-title":"Biomed. Signal Process. Control"},{"key":"ref_19","unstructured":"ClinicalTrials.gov (2015). Improving Postprandial Glycaemia by a New Developed Closed-Loop Control System -Closedloop4meals (CL4M-Controls)-NCT02100488."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Rossetti, P., Quir\u00f3s, C., Moscard\u00f3, V., Comas, A., Gim\u00e9nez, M., Ampudia-Blasco, F.J., Le\u00f3n, F., Montaser, E., Conget, I., and Bondia, J. (2017). Closed-loop control of postprandial glycemia using an insulin-on-board limitation through continuous action on glucose target. Diabetes Technol. Ther., in press.","DOI":"10.1089\/dia.2016.0443"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"2113","DOI":"10.1109\/TBME.2013.2247602","article-title":"Safety Auxiliary Feedback Element for the Artificial Pancreas in Type 1 Diabetes","volume":"60","author":"Revert","year":"2013","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"2664","DOI":"10.1109\/TBME.2011.2161083","article-title":"Online Denoising Method to Handle Intraindividual Variability of Signal-to-Noise Ratio in Continuous Glucose Monitoring","volume":"58","author":"Facchinetti","year":"2011","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_23","first-page":"E561","article-title":"Subcutaneous glucose predicts plasma glucose independent of insulin: Implications for continuous monitoring","volume":"277","author":"Rebrin","year":"1999","journal-title":"Am. J. Physiol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"881","DOI":"10.1089\/dia.2013.0077","article-title":"A New-Generation Continuous Glucose Monitoring System: Improved Accuracy and Reliability Compared with a Previous-Generation System","volume":"15","author":"Christiansen","year":"2013","journal-title":"Diabetes Technol. Ther."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1436","DOI":"10.1177\/193229681300700604","article-title":"Dexcom G4AP: An advanced continuous glucose monitor for the artificial pancreas","volume":"7","author":"Garcia","year":"2013","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1089\/dia.2011.0199","article-title":"Accuracy of the Enlite 6-Day Glucose Sensor with Guardian and Veo Calibration Algorithms","volume":"14","author":"Keenan","year":"2012","journal-title":"Diabetes Technol. Ther."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"10936","DOI":"10.3390\/s101210936","article-title":"Estimating Plasma Glucose from Interstitial Glucose: The Issue of Calibration Algorithms in Commercial Continuous Glucose Monitoring Devices","volume":"10","author":"Rossetti","year":"2010","journal-title":"Sensors"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1177\/1932296816629982","article-title":"Feasibility of an Orthogonal Redundant Sensor incorporating Optical plus Redundant Electrochemical Glucose Sensing","volume":"10","author":"McAuley","year":"2016","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"768","DOI":"10.1177\/193229680800200504","article-title":"A review of the foreign-body response to subcutaneously- implanted devices: Role of macrophages and cytokines in biofouling and fibrosis","volume":"2","author":"Ward","year":"2008","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1177\/193229681100500313","article-title":"Metabolic biofouling of glucose sensors in vivo: Role of tissue microhemorrhages","volume":"5","author":"Klueh","year":"2011","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"706","DOI":"10.2337\/dc11-1929","article-title":"The Accuracy Benefit of Multiple Amperometric Glucose Sensors in People With Type 1 Diabetes","volume":"35","author":"Castle","year":"2012","journal-title":"Diabetes Care"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1089\/dia.2009.0075","article-title":"New Features and Performance of a Next-Generation SEVEN-Day Continuous Glucose Monitoring System with Short Lag Time","volume":"11","author":"Bailey","year":"2009","journal-title":"Diabetes Technol. Ther."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1089\/15209150050194332","article-title":"Can interstitial glucose assessment replace blood glucose measurements?","volume":"2","author":"Rebrin","year":"2000","journal-title":"Diabetes Technol. Ther."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"1833","DOI":"10.1007\/s00125-005-1852-x","article-title":"Interstitial fluid glucose dynamics during insulin-induced hypoglycaemia","volume":"48","author":"Steil","year":"2005","journal-title":"Diabetologia"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"59","DOI":"10.2337\/dc06-1407","article-title":"The accuracy of the FreeStyle Navigator continuous glucose monitoring system in children with type 1 diabetes","volume":"30","author":"Wilson","year":"2007","journal-title":"Diabetes Care"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1089\/dia.2011.0101","article-title":"Effects of everyday life events on glucose, insulin, and glucagon dynamics in continuous subcutaneous insulin infusion-treated type 1 diabetes: Collection of clinical data for glucose modeling","volume":"14","author":"Schmidt","year":"2012","journal-title":"Diabetes Technol. Ther."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1111\/dom.12378","article-title":"Accuracy of two continuous glucose monitoring systems: A head-to-head comparison under clinical research centre and daily life conditions","volume":"17","author":"Kropff","year":"2015","journal-title":"Diabetes Obes. Metab."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/6\/1361\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T18:38:47Z","timestamp":1760207927000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/6\/1361"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,6,12]]},"references-count":37,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2017,6]]}},"alternative-id":["s17061361"],"URL":"https:\/\/doi.org\/10.3390\/s17061361","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2017,6,12]]}}}