{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,6]],"date-time":"2026-05-06T04:57:55Z","timestamp":1778043475985,"version":"3.51.4"},"reference-count":68,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2017,7,27]],"date-time":"2017-07-27T00:00:00Z","timestamp":1501113600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Raman spectroscopy provides label-free biochemical information from tissue samples without complicated sample preparation. The clinical capability of Raman spectroscopy has been demonstrated in a wide range of in vitro and in vivo applications. However, a challenge for in vivo applications is the simultaneous excitation of auto-fluorescence in the majority of tissues of interest, such as liver, bladder, brain, and others. Raman bands are then superimposed on a fluorescence background, which can be several orders of magnitude larger than the Raman signal. To eliminate the disturbing fluorescence background, several approaches are available. Among instrumentational methods shifted excitation Raman difference spectroscopy (SERDS) has been widely applied and studied. Similarly, computational techniques, for instance extended multiplicative scatter correction (EMSC), have also been employed to remove undesired background contributions. Here, we present a theoretical and experimental evaluation and comparison of fluorescence background removal approaches for Raman spectra based on SERDS and EMSC.<\/jats:p>","DOI":"10.3390\/s17081724","type":"journal-article","created":{"date-parts":[[2017,7,27]],"date-time":"2017-07-27T11:28:56Z","timestamp":1501154936000},"page":"1724","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":49,"title":["Evaluation of Shifted Excitation Raman Difference Spectroscopy and Comparison to Computational Background Correction Methods Applied to Biochemical Raman Spectra"],"prefix":"10.3390","volume":"17","author":[{"given":"Eliana","family":"Cordero","sequence":"first","affiliation":[{"name":"Leibniz Institute of Photonic Technology (IPHT), Albert-Einstein-Stra\u00dfe 9, Jena 07743, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Florian","family":"Korinth","sequence":"additional","affiliation":[{"name":"Leibniz Institute of Photonic Technology (IPHT), Albert-Einstein-Stra\u00dfe 9, Jena 07743, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Clara","family":"Stiebing","sequence":"additional","affiliation":[{"name":"Leibniz Institute of Photonic Technology (IPHT), Albert-Einstein-Stra\u00dfe 9, Jena 07743, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christoph","family":"Krafft","sequence":"additional","affiliation":[{"name":"Leibniz Institute of Photonic Technology (IPHT), Albert-Einstein-Stra\u00dfe 9, Jena 07743, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Iwan","family":"Schie","sequence":"additional","affiliation":[{"name":"Leibniz Institute of Photonic Technology (IPHT), Albert-Einstein-Stra\u00dfe 9, Jena 07743, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J\u00fcrgen","family":"Popp","sequence":"additional","affiliation":[{"name":"Leibniz Institute of Photonic Technology (IPHT), Albert-Einstein-Stra\u00dfe 9, Jena 07743, Germany"},{"name":"Institute of Physical Chemistry and Abbe Center of Photonics, Friedrich Schiller University Jena, Helmholtzweg 4, Jena 07743, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2017,7,27]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1819","DOI":"10.1039\/C5CS00564G","article-title":"Development in spontaneous and coherent Raman scattering microscopic imaging for biomedical applications","volume":"45","author":"Krafft","year":"2016","journal-title":"Chem. Soc. Rev."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"4392","DOI":"10.1002\/anie.201607604","article-title":"Label-free molecular imaging of biological cells and tissues by linear and non-linear Raman spectroscopic approaches","volume":"56","author":"Krafft","year":"2017","journal-title":"Angew. Chem."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1657","DOI":"10.1007\/s00216-006-0937-9","article-title":"The use of Raman spectroscopy to provide an estimation of the gross biochemistry asociated with urological pathologies","volume":"387","author":"Stone","year":"2007","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1232","DOI":"10.1111\/j.1464-410X.2004.04852.x","article-title":"The use of Raman spectroscopy to identify and characterize transitional cell carcicoma in vitro","volume":"93","author":"Crow","year":"2004","journal-title":"BJU Int."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1515\/plm-2014-0004","article-title":"Applications of Raman spectroscopy to the urinary bladder for cancer diagnostics","volume":"3","author":"Kerr","year":"2014","journal-title":"Photonics Lasers Med."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1126","DOI":"10.1016\/j.urology.2004.12.058","article-title":"Assesment of fiberoptic Near-infrared Raman spectroscopy for diagnostics of bladder and prostate cancer","volume":"65","author":"Crow","year":"2005","journal-title":"J. Urol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1053\/j.gastro.2013.11.002","article-title":"Fiberoptic confocal Raman spectroscopy for real-time in vivo diagnosis of dysplasia in Barrett\u2019s esophagus","volume":"146","author":"Bergholt","year":"2014","journal-title":"Gastroenterology"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"773","DOI":"10.1586\/14737159.2015.1036744","article-title":"Advantages and limitations of Raman spectroscopy for molecular diagnostics: An update","volume":"15","author":"Eberhardt","year":"2015","journal-title":"Expert Rev. Mol. Diagn."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"031113","DOI":"10.1117\/1.1920247","article-title":"Real-time Raman system for in vivo disease diagnosis","volume":"10","author":"Motz","year":"2005","journal-title":"J. Biomed. Opt."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"5993","DOI":"10.1021\/ac100448p","article-title":"In Vivo Bladder Cancer Daignosis by High-Volume Raman Spectroscopy","volume":"82","author":"Draga","year":"2010","journal-title":"Anal. Chem."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1771","DOI":"10.1016\/S0022-5347(05)64411-4","article-title":"Identification of bladder wall layers by Raman spectroscopy","volume":"168","author":"Schut","year":"2002","journal-title":"J. Urol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/S1387-2656(05)11007-2","article-title":"Cell and tissue autofluorescence research and diagnostic applications","volume":"11","author":"Monici","year":"2005","journal-title":"Biotechnol. Annu. Rev."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"10975","DOI":"10.1364\/OE.16.010975","article-title":"Multi-excitation Raman Spectroscopy Technique for Fluorescence Rejection","volume":"16","author":"McCain","year":"2008","journal-title":"Opt. Express"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"830","DOI":"10.1002\/jrs.1510","article-title":"On the use of photobleaching to reduce fluorescence background in Raman spectroscopy to improve the reliability of pigment identification on painted textiles","volume":"37","author":"Macdonald","year":"2006","journal-title":"J. Raman Spectrosc."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1016\/j.vibspec.2014.06.007","article-title":"Photobleaching as a useful technique in reducing of fluorescence in Raman spectra of blue automobile paint samples","volume":"74","author":"Michalska","year":"2014","journal-title":"Vib. Spectrosc."},{"key":"ref_16","first-page":"617","article-title":"Shifted-excitation difference spectroscopy for in vitro and in vivo biological samples analysis","volume":"1","author":"Riveiro","year":"2017","journal-title":"Biomed. Opt. Express"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1002\/jrs.2500","article-title":"An intelligent background-correction algorithm for highly fluorescent samples in Raman spectroscopy","volume":"41","author":"Zhang","year":"2009","journal-title":"J. Raman Spectrosc."},{"key":"ref_18","unstructured":"Venables, B., Hornik, K., and Maechler, M. (2017, July 26). Polynom: A Collection of Functions to Implement a Class for Univariate Polynomial Manipulations. Available online: https:\/\/rdrr.io\/github\/eestileib\/ComplexPoly\/."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1155\/2012\/530791","article-title":"Background estimation of biomedical Raman spectra using a geometric approach","volume":"27","author":"Kourkoumelis","year":"2012","journal-title":"Spectrosc. Int. J."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1140\/epjti\/s40485-015-0018-6","article-title":"Review of multidimensional data processing approaches for Raman and infrared spectroscopy","volume":"2","author":"Gautam","year":"2015","journal-title":"EPJ Tech. Instrum."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1363","DOI":"10.1366\/000370203322554518","article-title":"Automated Method for Subtraction of Fluorescence from Biological Raman Spectra","volume":"57","author":"Lieber","year":"2003","journal-title":"Appl. Spectrosc."},{"key":"ref_22","first-page":"1587","article-title":"Improved methods for fluorescence background substraction from Raman spectra","volume":"44","author":"Cadusch","year":"2013","journal-title":"Mater. Sci."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1021\/ac020194w","article-title":"Light scattering and ligth absorbance separated by extended multiplicative signal correction. Application to near-infrared transmission analysis of powder mixtures","volume":"75","author":"Martens","year":"2003","journal-title":"Anal. Chem."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.apcbee.2014.10.003","article-title":"A Polynomial Curve Fitting Method for Baseline Drift Correction in the Chromatographic Analysis of Hydrocarbons in Environmental Samples","volume":"10","author":"Mecozzi","year":"2014","journal-title":"APCBEE Procedia"},{"key":"ref_25","unstructured":"Massart, D.L., Vandeginste, B.G.M., Buydens, L.C.M., Jong, S.D., Lewi, P.J., and Smeyers-Verbeke, J. (1997). Data Handling in Science and Technology, Handbook of Chemometrics and Qualimetrics, Vols. 20A and 20B, Elsevier."},{"key":"ref_26","unstructured":"Vinzi, V.E., Chin, W.W., Henseler, J., and Wang, H. (2010). Handbook of Partial Least Squares: Concepts, Methods and Applications, Springer Science & Business Media."},{"key":"ref_27","first-page":"17","article-title":"Baseline correction using asymmetrically reweighted penalized least squares smoothing","volume":"140","author":"Baek","year":"2014","journal-title":"Analyst"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"643","DOI":"10.1002\/jrs.4886","article-title":"Model-based pre-processing in Raman spectroscopy of biological samples","volume":"47","author":"Liland","year":"2015","journal-title":"J. Raman Spectrosc."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"642","DOI":"10.1016\/S0009-2614(99)01427-X","article-title":"Separation of Raman spectra from fluorescence emission background by principal component analysis","volume":"317","author":"Hasegawaa","year":"2000","journal-title":"Chem. Phys. Lett."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"2083","DOI":"10.1109\/TBME.2011.2143713","article-title":"Signal Decomposition of Transmembrane Voltage-Sensitive Dye Fluorescence Using a Multiresolution Wavelet Analysis","volume":"58","author":"Asfour","year":"2011","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_31","first-page":"838","article-title":"Background correction in near-infrared spectra of plant extracts by orthogonal signal correction","volume":"6","author":"Qu","year":"2015","journal-title":"J. Zhejiang Univ. Sci. B"},{"key":"ref_32","unstructured":"Dennis, A. (2007). Photo-Bleaching and Automatic Baseline Correction for Raman Spectroscopy, PerkinElmer. R Package v 1.2-1."},{"key":"ref_33","first-page":"20049","article-title":"Development of a time-gated system for Raman spectroscopy of biological samples","volume":"18","author":"Knorr","year":"2010","journal-title":"J. Opt. Soc. Am."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1366\/0003702924125122","article-title":"Effective Rejection of Fluorescence Interference in Raman Spectroscopy Using a Shifted Excitation Difference Technique","volume":"46","author":"Shreve","year":"1992","journal-title":"Spectrosc. Tech."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"738","DOI":"10.1021\/ac9026737","article-title":"Online Fluorescence Suppression in Modulated Raman Spectroscopy","volume":"82","author":"Mazilu","year":"2010","journal-title":"Anal. Chem."},{"key":"ref_36","first-page":"198","article-title":"A novel Method for practical implementation of shifted-excitation Raman difference spectroscopy (SERDS)","volume":"47","author":"Dongy","year":"2012","journal-title":"Spectroscopy"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1002\/jrs.4775","article-title":"A shifted-excitation Raman difference spectroscopy (SERDS) evaluation strategy for the efficient isolation of Raman spectra from extreme fluorescence interference","volume":"47","author":"Gebrekidan","year":"2015","journal-title":"J. Raman Spectrosc."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1366\/000370207781540169","article-title":"Shift-Excitation Raman difference spectroscopy-difference deconvolution methods for the luminescence background rejection from Raman spectra of solid samples","volume":"61","author":"Osticioli","year":"2007","journal-title":"Appl. Spectrosc."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"964","DOI":"10.1366\/000370206778397344","article-title":"Fluorescence-suppressed Raman technique for quantitative analysis of protein solution using a micro-Raman probe, the shifted excitation method, and partial least squares regression analysis","volume":"60","author":"Oshima","year":"2006","journal-title":"Appl Spectrosc."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"8291","DOI":"10.1007\/s00216-015-8800-5","article-title":"Combined fiber probe for fluorescence lifetime and Raman spectroscopy","volume":"407","author":"Dochow","year":"2015","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"111609","DOI":"10.1117\/1.JBO.19.11.111609","article-title":"Clinical Raman measurements under special ambient lighting illumination","volume":"19","author":"Zhao","year":"2014","journal-title":"J. Biomed. Opt."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"5520","DOI":"10.1364\/AO.54.005520","article-title":"Capability of shifted excitation Raman difference spectroscopy under ambient daylight","volume":"54","author":"Maiwald","year":"2015","journal-title":"Appl. Opt."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"834","DOI":"10.1366\/000370202760171491","article-title":"Automated Fluorescence Rejection Using Shifted Excitation Raman Difference Spectroscopy","volume":"56","author":"Zhao","year":"2002","journal-title":"Appl. Spectrosc."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"4608","DOI":"10.1039\/c3ay40193f","article-title":"Classification of Raman spectra of single cells with autofluorescence suppression by wavelength modulated excitation","volume":"5","author":"Dochow","year":"2013","journal-title":"Anal. Methods"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"11382","DOI":"10.1364\/OE.18.011382","article-title":"Optimal algorithm for fluorescence suppression of modulated Raman spectroscopy","volume":"18","author":"Mazilu","year":"2010","journal-title":"Opt. Express"},{"key":"ref_46","doi-asserted-by":"crossref","unstructured":"Krafft, C., Dochow, S., Bergner, N., Clement, J.H., Praveen, B.B., Mazilu, M., Marchington, R., Dholakia, K., and Popp, J. (2012, January 9). Raman spectra of single cells with autofluorescence suppression by modulated wavelength excitation. Proceedings of the Biomedical Vibrational Spectroscopy V: Advances in Research and Industry, San Francisco, CA, USA.","DOI":"10.1117\/12.908564"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"888","DOI":"10.1366\/000370210792081028","article-title":"A Prototype Hand-Held Raman Sensor for the in situ Characterization of Meat Quality","volume":"64","author":"Schmidt","year":"2010","journal-title":"Appl. Spectrosc."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"1729","DOI":"10.1039\/a802802h","article-title":"Analysis of luminescent samples using subtracted shifted Raman spectroscopy","volume":"123","author":"Bell","year":"1998","journal-title":"Analyst"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"848","DOI":"10.1366\/0003702054280757","article-title":"Simple reconstruction algorithm for shifted excitation Raman difference spectroscopy","volume":"59","author":"Matousek","year":"2005","journal-title":"Appl. Spectrosc."},{"key":"ref_50","doi-asserted-by":"crossref","unstructured":"Willett, R. (2007, January 16\u201320). Multiscale reconstruction for photon-limited shifted excitation Raman spectroscopy. Proceedings of the IEEE International Conference on Acoustics, Speech and Signal Processing\u2014ICASSP, Honolulu, HI, USA.","DOI":"10.1109\/ICASSP.2007.366809"},{"key":"ref_51","unstructured":"Schmidt, H., Kaiser, D.P., and Maiwald, M. (2012). Method for Generating and for Detecting a Raman Spectrum. (8,310, 672), U.S. Patent."},{"key":"ref_52","unstructured":"Team, R.C. (2016). R: A Language and Environment for Statistical Computing, R Foundation for Statistical Computing."},{"key":"ref_53","unstructured":"Beleites, C., and Sergo, V. (2015). HyperSpec: A Package to Handle Hyperspectral Data Sets in R, R package v 0.98-20150805."},{"key":"ref_54","unstructured":"Liland, K.H., and Mevik, B.-H. (2017, July 26). Baseline:Baseline Correction of Spectra. Available online: https:\/\/cran.r-project.org\/web\/packages\/baseline\/index.html."},{"key":"ref_55","unstructured":"Borchers, H.W. (2017, July 26). Pracma: Practical Numerical Math Functions. Available online: https:\/\/www.rdocumentation.org\/packages\/pracma\/versions\/1.9.9."},{"key":"ref_56","unstructured":"Beleites, C. (2013). Ramancal: Calibration Routines for Raman Spectrometers, R Package v 0.1."},{"key":"ref_57","unstructured":"Hyndman, R. (2017, July 26). (Partial) Autocorrelation and Cross Correlation Function Estimation. Available online: https:\/\/www.rdocumentation.org\/packages\/forecast\/versions\/7.3."},{"key":"ref_58","unstructured":"Hyndman, R.J. (2017, July 26). Forecast: Forecasting Functions for Time Series and Linear Models. Available online: https:\/\/rdrr.io\/cran\/forecast\/."},{"key":"ref_59","unstructured":"Beleites, C. (2016). Cbmodels: Collection of \u201cCombined\u201d Models: PCA-LDA, PLS-LDA, PLS-LR as Well as EMSC, R Package v 0.5-20160412."},{"key":"ref_60","doi-asserted-by":"crossref","unstructured":"McCreery, R.L. (2000). Raman Spectroscopy for Chemical Analysis, Wiley-interscience.","DOI":"10.1002\/0471721646"},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"115","DOI":"10.3233\/BSI-160141","article-title":"Design and first applications of a flexible Raman micro-spectroscopic system for biological imaging","volume":"5","author":"Kiselev","year":"2016","journal-title":"Biomed. Spectrosc. Imaging"},{"key":"ref_62","doi-asserted-by":"crossref","unstructured":"Ryabchykov, O. (2016). Spikes: Spike Correction of Raman Spectral Data, R Package v 1.0.","DOI":"10.1016\/j.chemolab.2016.03.024"},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.chemolab.2016.03.024","article-title":"Automatization of spike correction in Raman spectra of biological samples","volume":"155","author":"Ryabchykov","year":"2016","journal-title":"Chemom. Intell. Lab. Syst."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"772","DOI":"10.1366\/0003702894202201","article-title":"Standard normal variate transformation and de-trending of near-infrared diffuse reflectance spectra","volume":"43","author":"Dhanoa","year":"1989","journal-title":"Appl. Spectrosc."},{"key":"ref_65","unstructured":"Slobodan, S. (2008). Pharmaceutical Applications of Raman Spectroscopy, John Wiley & Sons, Inc."},{"key":"ref_66","doi-asserted-by":"crossref","unstructured":"Long, D.A. (2002). The Raman Effect: A Unified Treatment of the Theory of Raman Scattering by Molecules, John Wiley & Sons Ltd.","DOI":"10.1002\/0470845767"},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"1180","DOI":"10.1002\/jrs.4953","article-title":"A portable shifted excitation Raman difference spectroscopy system: Device and field demonstration","volume":"47","author":"Maiwald","year":"2016","journal-title":"J. Raman Spectrosc."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"13680","DOI":"10.3390\/s150613680","article-title":"Modulated Raman Spectroscopy for Enhanced Cancer Diagnosis at the Cellular Level","volume":"15","author":"Dholakia","year":"2015","journal-title":"Sensors"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/8\/1724\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T18:44:17Z","timestamp":1760208257000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/8\/1724"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,7,27]]},"references-count":68,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2017,8]]}},"alternative-id":["s17081724"],"URL":"https:\/\/doi.org\/10.3390\/s17081724","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,7,27]]}}}