{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T02:59:49Z","timestamp":1792637989947,"version":"4.5.0"},"reference-count":29,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2017,8,25]],"date-time":"2017-08-25T00:00:00Z","timestamp":1503619200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Due to some of their unique properties, optical fiber dosimeters are attractive and extensively researched devices in several radiation-related areas. This work evaluates the performance and potential of commercial perfluorinated polymer optical fibers (PF-POFs) for radiation monitoring applications. Gamma radiation-induced attenuation (RIA) of two commercial PF-POFs is evaluated in the VIS spectral region. Influence of a dose rate and temperature on RIA measurement is investigated, along with defect stability and measurement repeatability. Co-extruded PF-POFs are identified as more suitable for radiation monitoring applications due to lower dose-rate dependence. With co-extruded PF-POF, RIA measurement holds potential for highly-sensitive radiation monitoring with good reproducibility. The results show that operation in the blue part of the spectrum provides most favorable performance in terms of the largest nominal radiation sensitivity, lower temperature, and dose-rate dependence as well as higher defect stability. We demonstrate for the first time to our knowledge, that PF-POFs can be used for distributed detection of radiation with doses down to tens of Grays. The off-the-shelf, user-friendly PF-POF could be of interest as a cheap, disposable sensor for various applications, especially of a more qualitative nature.<\/jats:p>","DOI":"10.3390\/s17091959","type":"journal-article","created":{"date-parts":[[2017,8,25]],"date-time":"2017-08-25T11:03:17Z","timestamp":1503658997000},"page":"1959","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":51,"title":["Radiation-Induced Attenuation of Perfluorinated Polymer Optical Fibers for Radiation Monitoring"],"prefix":"10.3390","volume":"17","author":[{"given":"Pavol","family":"Stajanca","sequence":"first","affiliation":[{"name":"Bundesanstalt f\u00fcr Materialforschung und -pr\u00fcfung (BAM), Unter den Eichen 87, 12205 Berlin, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katerina","family":"Krebber","sequence":"additional","affiliation":[{"name":"Bundesanstalt f\u00fcr Materialforschung und -pr\u00fcfung (BAM), Unter den Eichen 87, 12205 Berlin, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2017,8,25]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1108\/02602280810856705","article-title":"A review of optical fibre radiation dosimeters","volume":"28","author":"Fitzpatrick","year":"2008","journal-title":"Sens. Rev."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/S0168-583X(01)00713-3","article-title":"Remote optical fiber dosimetry","volume":"184","author":"Huston","year":"2001","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. B"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Yasin, M. (2012). Optical fibers and optical fiber sensors used in radiation monitoring. Selected Topics on Optical Fiber Technology, InTech.","DOI":"10.5772\/2429"},{"key":"ref_4","unstructured":"Bikit, I. (2014). Gamma Rays: Technology, Applications, and Health Implications, Nova Science Publishers."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1117\/12.7972434","article-title":"Optical fiber waveguides in radiation environments","volume":"18","author":"Friebele","year":"1979","journal-title":"Opt. Eng."},{"key":"ref_6","unstructured":"Brichard, B., and Fernandez-Fernandez, A. (2005, January 19\u201323). Radiation effects in silica glass optical fibers. Proceedings of the RADECS 2005 Short Course, Cap d\u2019Agde, France."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"2015","DOI":"10.1109\/TNS.2012.2235464","article-title":"Radiation effects on silica-based optical fibers: Recent advances and future challenges","volume":"60","author":"Girard","year":"2013","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/0168-583X(92)96023-R","article-title":"Optical fibres as radiation dosimeters","volume":"69","author":"Henschel","year":"1992","journal-title":"Nucl. Instrum. Meth. Phys. Res. B"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1496","DOI":"10.1016\/j.jnoncrysol.2009.05.017","article-title":"Radiation response behavior of high phosphorous doped step-index multimode optical fibers under low dose gamma irradiation","volume":"255","author":"Paul","year":"2009","journal-title":"J. Non-Cryst. Solids"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1016\/j.nima.2004.02.030","article-title":"Fibre optic radiation sensor systems for particle accelerators","volume":"526","author":"Henschel","year":"2004","journal-title":"Nucl. Instrum. Meth. Phys. Res. A"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1871","DOI":"10.1016\/j.jnoncrysol.2010.11.113","article-title":"Feasibility of radiation dosimetry wiht phosphorus-doped optical fibers in the ultraviolet and visible domain","volume":"357","author":"Girard","year":"2011","journal-title":"J. Non-Cryst. Solids"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"2511","DOI":"10.1109\/TNS.2013.2273273","article-title":"Comparison of gamma-radiation induced attenuation in al-doped, p-doped and ge-doped fibres for dosimetry","volume":"60","author":"Faustov","year":"2013","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"ref_13","first-page":"490","article-title":"Polymer optical fibre for in situ monitoring of gamma radiation processes","volume":"2","author":"Lewis","year":"2009","journal-title":"Int. J. Smart Sens. Intell. Syst."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"3171","DOI":"10.1088\/0957-0233\/18\/10\/S19","article-title":"Real-rime gamma dosimetry using PMMA optical fibres for applications in the sterilization industry","volume":"18","author":"Fitzpatrick","year":"2007","journal-title":"Meas. Sci. Technol."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"O'Keeffe, S., Lewis, E., Santhanam, A., Winningham, A., and Rolland, J.P. (2009, January 25\u201328). Low dose plastic optical fibre radiation dosimeter for clinical dosimetry applications. Proceedings of the IEEE Sensors 2009 Conference, Christchurch, New Zealand.","DOI":"10.1109\/ICSENS.2009.5398516"},{"key":"ref_16","unstructured":"Ziemann, O., Krauser, J., Zamzow, P.E., and Daum, W. (2008). POF Handbook: Optical Short Range Transmission Systems, Springer. [2nd ed.]."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Koike, Y. (2015). Fundamentals of Plastic Optical Fibers, Wiley.","DOI":"10.1002\/9783527646500"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"20140702","DOI":"10.1259\/bjr.20140702","article-title":"A review of recent advances in optical fibre sensors for in vivo dosimetry during radiotherapy","volume":"88","author":"McCarthy","year":"2015","journal-title":"Br. J. Radiol."},{"key":"ref_19","first-page":"96342l","article-title":"Plastic optical fibre sensor for in-vivo radiation monitoring during brachytherapy","volume":"9634","author":"Woulfe","year":"2015","journal-title":"Proc. SPIE"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"879418","DOI":"10.1117\/12.2025864","article-title":"Radiotherapy dosimetry based on plastic optical fibre sensors","volume":"8794","author":"Grattan","year":"2013","journal-title":"Proc. SPIE"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1016\/j.optmat.2016.05.027","article-title":"Effects of gamma radiation on perfluorinated polymer optical fibers","volume":"58","author":"Stajanca","year":"2016","journal-title":"Opt. Mater."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1006","DOI":"10.3390\/polym3031006","article-title":"Exploit the bandwidth capacities of the perfluorinated graded index polymer optical fiber for multi-services distribution","volume":"3","author":"Lethien","year":"2011","journal-title":"Polymers"},{"key":"ref_23","unstructured":"Stajanca, P., and Krebber, K. (2016, January 13\u201315). Radiation induced attenuation in perfluorinated polymer optical fibers for dosimetry applications. Proceedings of the POF 2016: 25th International Conference on Plastic Optical Fibres-Proceedings, Birmingham, UK."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"103231O","DOI":"10.1117\/12.2256354","article-title":"Towards on-line radiation monitoring with perfluorinated polymer optical fibers","volume":"10323","author":"Stajanca","year":"2017","journal-title":"Proc. SPIE"},{"key":"ref_25","unstructured":"(2017, July 10). Chromis Fiberoptics GigaPOF-50SR. Available online: http:\/\/www.chromisfiber.com\/pdf\/GigaPOF50SR.pdf."},{"key":"ref_26","unstructured":"(2017, July 10). Asahi Glass Company Fontex\u2122. Available online: http:\/\/www.lucina.jp\/eg_fontex\/."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"2375","DOI":"10.1364\/AO.16.002375","article-title":"Optical time domain reflectometer","volume":"16","author":"Barnoski","year":"1977","journal-title":"Appl. Opt."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"3303","DOI":"10.1109\/JLT.2016.2608849","article-title":"Distributed Optical fiber radiation sensing in a mixed-field radiation environment at CERN","volume":"35","author":"Toccafondo","year":"2017","journal-title":"J. Lightwave Technol."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1627","DOI":"10.1021\/ac60214a047","article-title":"Smoothing and differentiation of data by simplified least squares procedures","volume":"36","author":"Savitzky","year":"1964","journal-title":"Anal. Chem."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/9\/1959\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T18:43:16Z","timestamp":1760208196000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/9\/1959"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,8,25]]},"references-count":29,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2017,9]]}},"alternative-id":["s17091959"],"URL":"https:\/\/doi.org\/10.3390\/s17091959","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,8,25]]}}}