{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,10]],"date-time":"2026-01-10T02:23:18Z","timestamp":1768011798763,"version":"3.49.0"},"reference-count":55,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2017,9,6]],"date-time":"2017-09-06T00:00:00Z","timestamp":1504656000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003725","name":"National Research Foundation of Korea","doi-asserted-by":"publisher","award":["NRF-2015R1C1A1A02036624"],"award-info":[{"award-number":["NRF-2015R1C1A1A02036624"]}],"id":[{"id":"10.13039\/501100003725","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Red blood cell (RBC) aggregation and erythrocyte sedimentation rate (ESR) are considered to be promising biomarkers for effectively monitoring blood rheology at extremely low shear rates. In this study, a microfluidic-based measurement technique is suggested to evaluate RBC aggregation under hematocrit variations due to the continuous ESR. After the pipette tip is tightly fitted into an inlet port, a disposable suction pump is connected to the outlet port through a polyethylene tube. After dropping blood (approximately 0.2 mL) into the pipette tip, the blood flow can be started and stopped by periodically operating a pinch valve. To evaluate variations in RBC aggregation due to the continuous ESR, an EAI (Erythrocyte-sedimentation-rate Aggregation Index) is newly suggested, which uses temporal variations of image intensity. To demonstrate the proposed method, the dynamic characterization of the disposable suction pump is first quantitatively measured by varying the hematocrit levels and cavity volume of the suction pump. Next, variations in RBC aggregation and ESR are quantified by varying the hematocrit levels. The conventional aggregation index (AI) is maintained constant, unrelated to the hematocrit values. However, the EAI significantly decreased with respect to the hematocrit values. Thus, the EAI is more effective than the AI for monitoring variations in RBC aggregation due to the ESR. Lastly, the proposed method is employed to detect aggregated blood and thermally-induced blood. The EAI gradually increased as the concentration of a dextran solution increased. In addition, the EAI significantly decreased for thermally-induced blood. From this experimental demonstration, the proposed method is able to effectively measure variations in RBC aggregation due to continuous hematocrit variations, especially by quantifying the EAI.<\/jats:p>","DOI":"10.3390\/s17092037","type":"journal-article","created":{"date-parts":[[2017,9,6]],"date-time":"2017-09-06T11:23:34Z","timestamp":1504697014000},"page":"2037","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":29,"title":["Microfluidic-Based Measurement Method of Red Blood Cell Aggregation under Hematocrit Variations"],"prefix":"10.3390","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5047-3012","authenticated-orcid":false,"given":"Yang","family":"Kang","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju 61452, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2017,9,6]]},"reference":[{"key":"ref_1","first-page":"60","article-title":"Atherosclerosis, platelets and thrombosis in acute ischaemic heart disease","volume":"1","author":"Badimon","year":"2012","journal-title":"Eur. Heart J."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1357","DOI":"10.1073\/pnas.1209905110","article-title":"Atherosclerotic geometries exacerbate pathological thrombus formation poststenosis in a von Willebrand factor-dependent manner","volume":"110","author":"Westein","year":"2013","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"219","DOI":"10.2147\/VHRM.S29284","article-title":"Erythrocyte sedimentation rate as a marker for coronary heart disease","volume":"8","author":"Yayan","year":"2012","journal-title":"Vasc. Health Risk Manag."},{"key":"ref_4","first-page":"971453","article-title":"Emerging risk biomarkers in cardiovascular diseases and disorders","volume":"2015","author":"Upadhyay","year":"2015","journal-title":"J. Liqids"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"821","DOI":"10.3390\/genes5030821","article-title":"DNA methylation biomarkers: Cancer and beyond","volume":"5","author":"Mikeska","year":"2014","journal-title":"Genes"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1080\/00365510500236283","article-title":"Markers for early detection of cardiac diseases","volume":"240","author":"Wu","year":"2005","journal-title":"Scand. J. Clin. Lab. Investig."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"287","DOI":"10.4070\/kcj.2011.41.6.287","article-title":"Hemorheology and microvascular disorders","volume":"41","author":"Cho","year":"2011","journal-title":"Korean Circ. J."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1053\/euhj.1999.1699","article-title":"Haematocrit, viscosity, erythrocyte sedimentation rate: Meta-analyses of prospective studies of coronary heart disease","volume":"21","author":"Danesh","year":"2000","journal-title":"Eur. Heart J."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"4649","DOI":"10.1021\/acs.analchem.5b00677","article-title":"Development of a simple droplet-based microfluidic capillary viscometer for low-viscosity newtonian fluids","volume":"87","author":"DeLaMarre","year":"2015","journal-title":"Anal. Chem."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"034110","DOI":"10.1063\/1.4883275","article-title":"Changes in velocity profile according to blood viscosity in a microchannel","volume":"8","author":"Yeom","year":"2014","journal-title":"Biomicrofluidics"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1007\/s10404-013-1261-2","article-title":"Multiplexed microfluidic viscometer for high-throughput complex fluid rheology","volume":"16","author":"Solomon","year":"2014","journal-title":"Microfluid. Nanofluid."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1016\/j.bios.2012.09.033","article-title":"On-line blood viscosity monitoring In Vivo with a central venous catheter using electrical impedance technique","volume":"41","author":"Pop","year":"2013","journal-title":"Biosens. Bioelectron."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.clinbiochem.2012.10.015","article-title":"Analycal performance evaluation of the scanning tube viscometer for measurement of whole blood viscosity","volume":"46","author":"Kim","year":"2013","journal-title":"Clin. Biochem."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1007\/s10404-012-1085-5","article-title":"Integrated microfluidic viscometer equipped with fluid temperature controller for measurement of viscosity in complex fluids","volume":"14","author":"Kang","year":"2013","journal-title":"Microfluid. Nanofluid."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"944","DOI":"10.1111\/j.1525-1594.2010.01078.x","article-title":"A highly accurate and consistent microfluidic viscometer for continuous blood viscosity measurement","volume":"34","author":"Kang","year":"2010","journal-title":"Artif. Organs"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1007\/s10404-008-0273-9","article-title":"Towards a continuous microfluidic rheometer","volume":"5","author":"Guillot","year":"2008","journal-title":"Microfluid. Nanofluid."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"4682","DOI":"10.1039\/C6LC01036A","article-title":"A portable microfluidic system for rapid measurement of the erythrocyte sedimentation rate","volume":"16","author":"Isiksacan","year":"2016","journal-title":"Lab Chip"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Zhbanov, A., and Yang, S. (2015). Effects of aggregation on blood sedimentation and conductivity. PLoS ONE, 10.","DOI":"10.1371\/journal.pone.0129337"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"044114","DOI":"10.1063\/1.4892037","article-title":"Microfluidic-based measurement of erythrocyte sedimentation rate for biophysical assessment of blood in an In Vivo malaria-infected mouse","volume":"8","author":"Kang","year":"2014","journal-title":"Biomicrofluidics"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"969","DOI":"10.1109\/TBME.2009.2036598","article-title":"Time course of electrical impedance during red blood cell aggregation in a glass tube: Comparison with light transmittance","volume":"57","author":"Baskurt","year":"2010","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1088\/0967-3334\/15\/4\/011","article-title":"A new bioelectrical impedance method for measurement of the erythrocyte sedimentation rate","volume":"15","author":"Cha","year":"1994","journal-title":"Physiol. Meas."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1572","DOI":"10.1182\/blood.V70.5.1572.1572","article-title":"Mechanism of erythrocyte aggregation and sedimentation","volume":"70","author":"Fabry","year":"1987","journal-title":"Blood"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"978","DOI":"10.1002\/elps.201400466","article-title":"Electrochemical hematocrit determination in a direct current microfluidic device","volume":"36","author":"Lee","year":"2015","journal-title":"Electrophoresis"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1016\/j.bios.2012.02.010","article-title":"Improvement of electrical blood hematocrit measurements under various plasma conditions using a novel hematocrit estimation parameter","volume":"35","author":"Kim","year":"2012","journal-title":"Biosens. Bioelectron."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"153508","DOI":"10.1063\/1.4871706","article-title":"Improvement of the accuracy of continuous hematocrit measurement under various blood flow conditions","volume":"104","author":"Kim","year":"2014","journal-title":"Appl. Phys. Lett."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"44563","DOI":"10.1038\/srep44563","article-title":"Partitioning of red blood cell aggregates in bifurcating microscale flows","volume":"7","author":"Kaliviotis","year":"2017","journal-title":"Sci. Rep."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"035001","DOI":"10.1117\/1.JBO.21.3.035001","article-title":"Optical tweezers study of red blood cell aggregation and disaggregation in plasma and protein solutions","volume":"21","author":"Lee","year":"2016","journal-title":"J. Biomed. Opt."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"6583","DOI":"10.1039\/C6AN01593J","article-title":"Continuous and simultaneous measurement of the biophysical properties of blood in a microfluidic environment","volume":"141","author":"Kang","year":"2016","journal-title":"Analyst"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"145","DOI":"10.5090\/kjtcs.2016.49.3.145","article-title":"The effect of pulsatile versus nonpulsatile blood flow on viscoelasticity and red blood cell aggregation in extracorporeal circulation","volume":"49","author":"Ahn","year":"2016","journal-title":"Korean J. Thorac. Cardiovasc. Surg."},{"key":"ref_30","first-page":"61","article-title":"Measurement of cell aggregation characteristics by analysis of laser-backscattering in a microfluidic rheometry","volume":"19","author":"Shin","year":"2007","journal-title":"Korea-Aust. Rheol. J."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"4348","DOI":"10.1038\/srep04348","article-title":"The plasma protein fibrinogen stabilizes clusters of red blood cells in microcapillary flows","volume":"4","author":"Brust","year":"2014","journal-title":"Sci. Rep."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"2912","DOI":"10.1021\/acs.analchem.5b04874","article-title":"High-throughput and label-free blood-on-a-chip for malaria diagnosis","volume":"88","author":"Kang","year":"2016","journal-title":"Anal. Chem."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"014102","DOI":"10.1063\/1.4973863","article-title":"Simultaneous measurement of erythrocyte deformability and blood viscoelasticity using micropillars and co-flowing streams under pulsatile blood flows","volume":"11","author":"Kang","year":"2017","journal-title":"Biomicrofluidics"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1039\/C5LC01248A","article-title":"Deformability based sorting of red blood cells improves diagnostic sensitivity for malaria caused by Plasmodium falciparum","volume":"16","author":"Guo","year":"2016","journal-title":"Lab Chip"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"1135","DOI":"10.1039\/c3lc51003d","article-title":"Red blood cell fatigue evaluation based on the close-encountering point between extensibility and recoverability","volume":"14","author":"Sakuma","year":"2014","journal-title":"Lab Chip"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"764268","DOI":"10.1155\/2014\/764268","article-title":"Alterations in red blood cell deformability during storage: A microfluidic approach","volume":"2014","author":"Cluitmans","year":"2014","journal-title":"BioMed Res. Int."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"7630","DOI":"10.1073\/pnas.1200107109","article-title":"Hydrodynamic stretching of single cells for large population mechanical phenotying","volume":"109","author":"Gossett","year":"2012","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"10471","DOI":"10.1021\/ac302763n","article-title":"Cell stretching measurement utilizing viscoelastic particle focusing","volume":"84","author":"Cha","year":"2012","journal-title":"Anal. Chem."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"6438","DOI":"10.1021\/ac300264v","article-title":"Microfluidics-based assessment of cell deformability","volume":"84","author":"Adamo","year":"2012","journal-title":"Anal. Chem."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1039\/C0LC00348D","article-title":"Microfluidics analysis of red blood cell membrane viscoelasticity","volume":"11","author":"Tomaiuolo","year":"2011","journal-title":"Lab Chip"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"044106","DOI":"10.1063\/1.4816713","article-title":"Label-free viscosity measurement of complex fluids using reversal flow switching manipulation in a microfluidic channel","volume":"7","author":"Kang","year":"2013","journal-title":"Biomicrofluidics"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"1881","DOI":"10.1039\/c2lc21163g","article-title":"Fluidic low pass filter for hydrodynamic flow stabilization in microfluidic environments","volume":"12","author":"Kang","year":"2012","journal-title":"Lab Chip"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"1447","DOI":"10.1172\/JCI105836","article-title":"On the shear rate dependence of red cell aggregation in vitro","volume":"47","author":"Gaehtgens","year":"1968","journal-title":"J. Clin. Investig."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1055\/s-2003-44551","article-title":"Blood rhelogy and hemodynamics","volume":"29","author":"Baskurt","year":"2003","journal-title":"Semin. Thromb. Hemost."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"051903","DOI":"10.1063\/1.4721811","article-title":"Red blood cell clustering in poiseuille microcapillary flow","volume":"24","author":"Tomaiuolo","year":"2012","journal-title":"Phys. Fluids"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1007\/s00397-015-0894-3","article-title":"Blood linear viscoelasticity by small amplitude oscillatory flow","volume":"55","author":"Tomaiuolo","year":"2016","journal-title":"Rheol. Acta"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"024110","DOI":"10.1063\/1.4917023","article-title":"Microfluidic-based speckle analysis for sensitive measurement of erythrocyte aggregation: A comparison of four methods for detection of elevated erythrocyte aggregation in diabetic rat blood","volume":"9","author":"Yeom","year":"2015","journal-title":"Biomicrofluidics"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"2067","DOI":"10.1021\/ac202934x","article-title":"Lifting gate PDMS microvalves and pumps for microfluidic control","volume":"84","author":"Kim","year":"2012","journal-title":"Anal. Chem."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1016\/j.sna.2014.01.016","article-title":"Effect of phase shift on optimal operation of serial-connected valveless micropumps","volume":"209","author":"Kim","year":"2014","journal-title":"Sens. Actuators A Phys."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1016\/0301-5629(95)00022-J","article-title":"Roles of hematocrit and fibrinogen in red cell aggregation determined by ultrasonic scattering properties","volume":"21","author":"Kitamura","year":"1995","journal-title":"Ultrasound Med. Biol."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1109\/10.135540","article-title":"The effects of hematocrit, shear rate, and turbulence on ultrasonic doppler spectrum from blood","volume":"39","author":"Shung","year":"1992","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_52","first-page":"1151","article-title":"Ultrasonic backscattering from porcine whole blood of varying hematocrit and shear rate under pulsatile flow","volume":"25","author":"Lin","year":"1996","journal-title":"Utasound Med. Biol."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"054122","DOI":"10.1063\/1.4827355","article-title":"Blood viscoelasticity measurement using steady and transient flow controls of blood in a microfluidic analogue of Wheastone-bridge channel","volume":"7","author":"Kang","year":"2013","journal-title":"Biomicrofluidics"},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"24025","DOI":"10.1364\/OE.21.024025","article-title":"Assessment of the flow velocity of blood cells in a microfluidic device using joint spectral and time domain optical coherence tomography","volume":"21","author":"Bukowska","year":"2013","journal-title":"Opt. Express"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"1306","DOI":"10.1002\/smll.201000210","article-title":"Microfluidic rheometer for characterization of protein unfolding and aggregation in microflows","volume":"6","author":"Choi","year":"2010","journal-title":"Small"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/9\/2037\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T18:44:17Z","timestamp":1760208257000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/9\/2037"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,9,6]]},"references-count":55,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2017,9]]}},"alternative-id":["s17092037"],"URL":"https:\/\/doi.org\/10.3390\/s17092037","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,9,6]]}}}