{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,17]],"date-time":"2025-10-17T13:56:51Z","timestamp":1760709411776,"version":"build-2065373602"},"reference-count":24,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2017,9,19]],"date-time":"2017-09-19T00:00:00Z","timestamp":1505779200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A rapid and reproducible fiber-optic immunosensor for Escherichia coli O157:H7 (E. coli O157:H7) was described. The biosensor consisted of a flow cell, an optical fiber with a thin Ni layer, and a PC linked fluorometer. First, the samples with E. coli O157:H7 were incubated with magnetic beads coated with anti-E. coli O157:H7 antibodies and anti-E. coli O157:H7 antibodies labeled cyanine 5 (Cy5) to make sandwich complexes. Then the Cy5-(E. coli O157:H7)-beads were injected into a flow cell and pulled to the magnetized Ni layer on the optical fiber set in the flow cell. An excitation light (\u03bb = 635 nm) was used to illuminate the optical fiber, and the Cy5 florescent molecules facing the optical fiber were exposed to an evanescent wave from the optical fiber. The 670 nm fluorescent light was measured using a photodiode. Finally, the magnetic intensity of the Ni layer was removed and the Cy5-E. coli O157:H7-beads were washed out for the next immunoassay. E. coli O157:H7, diluted with phosphate buffer (PB), was measured from 1 \u00d7 105 to 1 \u00d7 107 cells\/mL. The total time required for an assay was less than 15 min (except for the pretreatment process) and repeating immunoassay on one optical fiber was made possible.<\/jats:p>","DOI":"10.3390\/s17092145","type":"journal-article","created":{"date-parts":[[2017,9,19]],"date-time":"2017-09-19T11:04:35Z","timestamp":1505819075000},"page":"2145","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Repetitive Immunosensor with a Fiber-Optic Device and Antibody-Coated Magnetic Beads for Semi-Continuous Monitoring of Escherichia coli O157:H7"],"prefix":"10.3390","volume":"17","author":[{"given":"Midori","family":"Taniguchi","sequence":"first","affiliation":[{"name":"Department of Biomedical Devices and Instrumentation, Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, 2-3-10 Kanda-Surugadai, Chiyoda-ku, Tokyo 101-0062, Japan"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7326-4435","authenticated-orcid":false,"given":"Hirokazu","family":"Saito","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Tokyo National College of Technology, 1220-1, Kunugida-machi, Hachioji-shi, Tokyo 193-0997, Japan"}]},{"given":"Kohji","family":"Mitsubayashi","sequence":"additional","affiliation":[{"name":"Department of Biomedical Devices and Instrumentation, Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, 2-3-10 Kanda-Surugadai, Chiyoda-ku, Tokyo 101-0062, Japan"}]}],"member":"1968","published-online":{"date-parts":[[2017,9,19]]},"reference":[{"key":"ref_1","unstructured":"Azuma, M., and Oguma, K. (2000). Concise Text of Microbiology, Nankodo Publishing Co., Ltd.. [3rd ed.]."},{"key":"ref_2","unstructured":"Miyasaka, N., Karasuyama, H., Asakawa, H., and Tozawa, H. (2001). Clinical Immunology, Kodansya. [1st ed.]."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Gosling, J. (2000). Immunoassays, Oxford University Press.","DOI":"10.1093\/oso\/9780199637119.001.0001"},{"key":"ref_4","unstructured":"Urayama, S. (2003). Clinical Chemical Test, Ishiyaku Publishing Co., Ltd."},{"key":"ref_5","unstructured":"Karube, I. (2002). Biosensor, CMC Publishing Co., Ltd."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1016\/S0956-5663(99)00039-1","article-title":"Biosensors for detection of pathogenic bacteria","volume":"14","author":"Ivnitski","year":"1999","journal-title":"Biosens. Bioelectron."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1016\/0003-2697(92)90440-I","article-title":"Detection of Clostridium botulinum toxin A using a fiber optic-based biosensor Original Research Article","volume":"205","author":"Oqert","year":"1992","journal-title":"Anal. Biochem."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1007\/BF02783583","article-title":"Detection of endotoxin using an evanescent wave fiber-optic biosensor","volume":"60","author":"James","year":"1996","journal-title":"Appl. Biochem. Biotechnol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"942","DOI":"10.1097\/00002480-199642060-00004","article-title":"Assay Development for a portable fiberoptic biosensor","volume":"42","author":"Anderson","year":"1996","journal-title":"ASAIO J."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/S0925-4005(97)80333-4","article-title":"A compact fiber-optic immunosensor for Salmonella based on evanescent wave excitation Original research article","volume":"42","author":"Zhou","year":"1997","journal-title":"Sens. Actuators B"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1006\/abio.1996.0006","article-title":"Quantitating staphylococcal enterotoxin B in diverse media using a portable fiber-optic biosensor original research article","volume":"233","author":"Tempelmana","year":"1996","journal-title":"Anal. Biochem."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/S0003-2670(99)00571-1","article-title":"Multi-analyte explosive detection using a fiber optic biosensor Original research article","volume":"399","author":"Bakaltcheva","year":"1999","journal-title":"Anal. Chim. Acta"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"711","DOI":"10.4315\/0362-028X-62.7.711","article-title":"Rapid detection of Escherichia coli O157:H7 in ground beef using a fiber-optic biosensor","volume":"62","author":"DeMarco","year":"1999","journal-title":"J. Food Protect."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"DeMarco, D.R., and Lim, D.V. (2002). Detection of Escherichia coli O157:H7 in 10- and 25-gram ground beef samples with an evanescent-wave biosensor with silica and polystyrene waveguides. J. Food Protect., 596\u2013602.","DOI":"10.4315\/0362-028X-65.4.596"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"6138","DOI":"10.1128\/AEM.70.10.6138-6146.2004","article-title":"Detection of low levels of Listeria monocytogenes cells by using a fiber-optic immunosensor","volume":"70","author":"Geng","year":"2004","journal-title":"Appl. Environ. Microbiol."},{"key":"ref_16","unstructured":"Abe, M., and Noda, K. (2006). Biomedical and Environmental Applications of Functionalized Magnetic Beads, CMC Publishing Co., Ltd."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1099\/00222615-40-6-424","article-title":"A comparison of immunomagnetic separation and direct culture for the isolation of verocytotoxin-producing Escherichia coli 0157 from bovine faeces","volume":"40","author":"Champman","year":"1994","journal-title":"J. Med. Microbiol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1111\/j.1472-765X.1996.tb01151.x","article-title":"The isolation and detection of Escherichia coli O157 by use of immunomagnetic separation and immunoassay procedures","volume":"22","author":"Bennett","year":"1996","journal-title":"Lett. Appl. Microbiol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1006\/fmic.2001.0416","article-title":"The detection of Salmonella serovars from animal feed and raw chicken using a combined immunomagnetic separation and ELISA method","volume":"18","author":"Mansfield","year":"2001","journal-title":"Food Microbiol."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1046\/j.1472-765X.2003.01439.x","article-title":"Enumeration of Escherichia coli O157 in cattle faeces using most probable number technique and automated immunomagnetic separation","volume":"38","author":"Fegan","year":"2004","journal-title":"Lett. Appl. Microbiol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1111\/j.1472-765X.2005.01667.x","article-title":"Detection and recovery rates achieved using direct plate and enrichment\/immunomagnetic separation methods for Escherichia coli O157:H7 in minced beef and on bovine hide","volume":"41","author":"Duffy","year":"2005","journal-title":"Lett. Appl. Microbiol."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1496","DOI":"10.1007\/s00467-005-1996-4","article-title":"Colonic stricture secondary to hemolytic uremic syndrome caused by Escherichia coli O-157","volume":"20","author":"Masumoto","year":"2005","journal-title":"Pediatr. Nephrol."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1099\/00222615-44-4-273","article-title":"The detection of verocytotoxins in bacterial cultures from human diarrhoeal samples with monoclonal antibody-based ELISAs","volume":"44","author":"Ball","year":"1996","journal-title":"J. Med. Microbiol."},{"key":"ref_24","unstructured":"(2017, September 10). MaxSignal\u00ae E. coli O157:H7 ELISA Test Kit. Available online: http:\/\/www.biooscientific.com\/MaxSignal-E-coli-O157H7-ELISA-Test-Kit."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/9\/2145\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T18:45:17Z","timestamp":1760208317000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/9\/2145"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,9,19]]},"references-count":24,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2017,9]]}},"alternative-id":["s17092145"],"URL":"https:\/\/doi.org\/10.3390\/s17092145","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2017,9,19]]}}}