{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T13:57:10Z","timestamp":1790085430311,"version":"4.0.1"},"reference-count":32,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2017,10,27]],"date-time":"2017-10-27T00:00:00Z","timestamp":1509062400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The magnetic resonance sounding (MRS) technique is a non-invasive geophysical method that can provide unique insights into the hydrological properties of groundwater. The Cu coil sensor is the preferred choice for detecting the weak MRS signal because of its high sensitivity, low fabrication complexity and low cost. The tuned configuration was traditionally used for the MRS coil sensor design because of its high sensitivity and narrowband filtering. However, its narrow bandwidth may distort the MRS signals. To address this issue, a non-tuned design exhibiting a broad bandwidth has emerged recently, however, the sensitivity decreases as the bandwidth increases. Moreover, the effect of the MRS applications is often seriously influenced by power harmonic noises in the developed areas, especially low-frequency harmonics, resulting in saturation of the coil sensor, regardless of the tuned or non-tuned configuration. To solve the two aforementioned problems, we propose a matching network consisting of an LC broadband filter in parallel with a matching capacitor and provide a design for a coil sensor with a matching network (CSMN). The theoretical parameter calculations and the equivalent schematic of the CSMN with noise sources are investigated, and the sensitivity of the CSMN is evaluated by the Allan variance and the signal-to-noise ratio (SNR). Correspondingly, we constructed the CSMN with a 3 dB bandwidth, passband gain, normalized equivalent input noise and sensitivity (detection limit) of 1030 Hz, 4.6 dB, 1.78 nV\/(Hz)1\/2 @ 2 kHz and 3 nV, respectively. Experimental tests in the laboratory show that the CSMN can not only improve the sensitivity, but also inhibit the signal distortion by suppressing power harmonic noises in the strong electromagnetic interference environment. Finally, a field experiment is performed with the CSMN to show a valid measurement of the signals of an MRS instrument system.<\/jats:p>","DOI":"10.3390\/s17112463","type":"journal-article","created":{"date-parts":[[2017,10,27]],"date-time":"2017-10-27T11:33:28Z","timestamp":1509104008000},"page":"2463","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Design of a Matching Network for a High-Sensitivity Broadband Magnetic Resonance Sounding Coil Sensor"],"prefix":"10.3390","volume":"17","author":[{"given":"Yang","family":"Zhang","sequence":"first","affiliation":[{"name":"College of Instrumentation & Electrical Engineering, Lab of Geo-Exploration Instrumentation of Ministry of Education, Jilin University, Changchun 130026, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7922-5795","authenticated-orcid":false,"given":"Fei","family":"Teng","sequence":"additional","affiliation":[{"name":"College of Instrumentation & Electrical Engineering, Lab of Geo-Exploration Instrumentation of Ministry of Education, Jilin University, Changchun 130026, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Suhang","family":"Li","sequence":"additional","affiliation":[{"name":"College of Instrumentation & Electrical Engineering, Lab of Geo-Exploration Instrumentation of Ministry of Education, Jilin University, Changchun 130026, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ling","family":"Wan","sequence":"additional","affiliation":[{"name":"College of Instrumentation & Electrical Engineering, Lab of Geo-Exploration Instrumentation of Ministry of Education, Jilin University, Changchun 130026, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6061-2311","authenticated-orcid":false,"given":"Tingting","family":"Lin","sequence":"additional","affiliation":[{"name":"College of Instrumentation & Electrical Engineering, Lab of Geo-Exploration Instrumentation of Ministry of Education, Jilin University, Changchun 130026, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2017,10,27]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1071\/EG991333","article-title":"A new direct non-invasive groundwater detection technology for Australia","volume":"22","author":"Schirov","year":"1991","journal-title":"Explor. Geophys."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/S0926-9851(98)00011-1","article-title":"Processing of surface proton magnetic resonance signals using non-linear fitting","volume":"39","author":"Legchenko","year":"1998","journal-title":"J. Appl. Geophys."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1007\/s10712-014-9304-0","article-title":"A review of the principles and applications of the NMR technique for near-surface characterization","volume":"36","author":"Behroozmand","year":"2015","journal-title":"Surv. Geophys."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/S0022-1694(03)00170-7","article-title":"Hydrogeological interpretation and potential of the new magnetic resonance sounding (MRS) method","volume":"283","author":"Lubczynski","year":"2003","journal-title":"J. Hydrol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/S0926-9851(02)00127-1","article-title":"A review of the basic principles for proton magnetic resonance sounding measurements","volume":"50","author":"Legchenko","year":"2002","journal-title":"J. Appl. Geophys."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/S0926-9851(02)00139-8","article-title":"Inversion of surface nuclear magnetic resonance data by an adapted Monte Carlo method applied to water resource characterization","volume":"50","author":"Guillen","year":"2002","journal-title":"J. Appl. Geophys."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1111\/j.1745-6584.2004.tb02684.x","article-title":"Magnetic resonance sounding applied to aquifer characterization","volume":"42","author":"Legchenko","year":"2004","journal-title":"Groundwater"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1109\/JSTARS.2015.2457445","article-title":"A para-whole space model for underground magnetic resonance sounding studies","volume":"9","author":"Lin","year":"2016","journal-title":"IEEE J. Sel. Top. Appl. Earth Obs. Remote Sens."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/j.pnmrs.2008.01.002","article-title":"Imaging of groundwater with nuclear magnetic resonance","volume":"53","author":"Hertrich","year":"2008","journal-title":"Prog. Nucl. Magn. Reson. Spectrosc."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1016\/j.jappgeo.2007.08.001","article-title":"2D magnetic resonance tomography applied to karstic conduit imaging","volume":"63","author":"Girard","year":"2007","journal-title":"J. Appl. Geophys."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"025022","DOI":"10.1088\/1367-2630\/13\/2\/025022","article-title":"Three-dimensional magnetic resonance imaging for groundwater","volume":"13","author":"Legchenko","year":"2011","journal-title":"New J. Phys."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1016\/j.jappgeo.2011.06.010","article-title":"The underground application of magnetic resonance soundings","volume":"75","author":"Greben","year":"2011","journal-title":"J. Appl. Geophys."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1110","DOI":"10.1088\/0022-3735\/15\/10\/034","article-title":"Air-core induction-coil magnetometer design","volume":"15","author":"Estola","year":"1982","journal-title":"J. Phys. E Sci. Instrum."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"7126","DOI":"10.3390\/s120607126","article-title":"Advancements in transmitters and sensors for biological tissue imaging in magnetic induction tomography","volume":"12","author":"Zakaria","year":"2012","journal-title":"Sensors"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1109\/TASC.2010.2089402","article-title":"SQUIDs vs. induction coils for ultra-low field nuclear magnetic resonance: Experimental and simulation comparison","volume":"21","author":"Matlashov","year":"2011","journal-title":"IEEE Trans. Appl. Supercond."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"2269","DOI":"10.1038\/s41598-017-02099-z","article-title":"Towards ultimate low frequency air-core magnetometer sensitivity","volume":"7","author":"Vogel","year":"2017","journal-title":"Sci. Rep."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"439","DOI":"10.3379\/jmsjmag.30.439","article-title":"Optimal design of an air-core induction magnetometer for detecting low-frequency fields of less than 1 pT","volume":"30","author":"Tashiro","year":"2006","journal-title":"J. Magn. Soc. Jpn."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"114708","DOI":"10.1063\/1.4901964","article-title":"High-sensitivity cooled coil system for nuclear magnetic resonance in kHz range","volume":"85","author":"Lin","year":"2014","journal-title":"Rev. Sci. Instrum."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Lin, J., Du, G., Zhang, J., Yi, X., Jiang, C., and Lin, T. (2017). Development of a rigid one-meter-side and cooled coil sensor at 77 K for magnetic resonance sounding to detect subsurface water sources. Sensors, 17.","DOI":"10.3390\/s17061362"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1016\/j.jappgeo.2008.03.006","article-title":"Multi-channel surface NMR instrumentation and software for 1D\/2D groundwater investigations","volume":"66","author":"Walsh","year":"2008","journal-title":"J. Appl. Geophys."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1111\/j.1365-246X.2012.05618.x","article-title":"Adaptive noise cancelling of multichannel magnetic resonance sounding signals","volume":"191","author":"Dalgaard","year":"2012","journal-title":"Geophys. J. Int."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"459","DOI":"10.3997\/1873-0604.2011026","article-title":"Statistical stacking and adaptive notch filter to remove high-level electromagnetic noise from MRS measurements","volume":"9","author":"Jiang","year":"2011","journal-title":"Near Surface Geophys."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"114702","DOI":"10.1063\/1.4934969","article-title":"Signal acquisition module design for multi-channel surface magnetic resonance sounding system","volume":"86","author":"Lin","year":"2015","journal-title":"Rev. Sci. Instrum."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1016\/S0926-9851(03)00041-7","article-title":"Removal of power-line harmonics from proton magnetic resonance measurements","volume":"53","author":"Legchenko","year":"2003","journal-title":"J. Appl. Geophys."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1111\/j.1365-2478.1994.tb00245.x","article-title":"The potential of a noise-reducing antenna for surface NMR groundwater surveys in the Earth\u2019s magnetic field","volume":"42","author":"Trushkin","year":"1994","journal-title":"Geophys. Prospect."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"064702","DOI":"10.1063\/1.4984295","article-title":"Anti-saturation system for surface nuclear magnetic resonance in efficient groundwater detection","volume":"88","author":"Lin","year":"2017","journal-title":"Rev. Sci. Instrum."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Chen, S., Guo, S., Wang, H., He, M., Liu, X., Qiu, Y., and Zhu, J. (2017). An improved high-sensitivity airborne transient electromagnetic sensor for deep penetration. Sensors, 17.","DOI":"10.3390\/s17010169"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"712","DOI":"10.3390\/s6070712","article-title":"A miniaturized magnetic induction sensor using geomagnetism for turn count of small-caliber ammunition","volume":"6","author":"Yoon","year":"2006","journal-title":"Sensors"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"2468","DOI":"10.3390\/s140202468","article-title":"Magnetic sensor for building structural vibrations","volume":"14","author":"Tremps","year":"2014","journal-title":"Sensors"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.jappgeo.2013.02.002","article-title":"Non-invasive characterization of water-bearing strata using a combination of geophysical techniques","volume":"91","author":"Lin","year":"2013","journal-title":"J. Appl. Geophys."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1109\/PROC.1966.4634","article-title":"Statistics of atomic frequency standards","volume":"54","author":"Allan","year":"1966","journal-title":"Proc. IEEE"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1007\/BF00425997","article-title":"The limits of signal averaging in atmospheric trace-gas monitoring by tunable diode-laser absorption spectroscopy (TDLAS)","volume":"57","author":"Werle","year":"1993","journal-title":"Appl. Phys. B Lasers Opt."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/11\/2463\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T18:48:36Z","timestamp":1760208516000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/11\/2463"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,10,27]]},"references-count":32,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2017,11]]}},"alternative-id":["s17112463"],"URL":"https:\/\/doi.org\/10.3390\/s17112463","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,10,27]]}}}