{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T05:05:27Z","timestamp":1787029527980,"version":"build-2736575974"},"reference-count":21,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2017,10,27]],"date-time":"2017-10-27T00:00:00Z","timestamp":1509062400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"National Research Foundation of Korea (NRF)","award":["2015R1A2A2A01006446"],"award-info":[{"award-number":["2015R1A2A2A01006446"]}]},{"name":"National Research Foundation of Korea (NRF)","award":["2016R1A2B4013054"],"award-info":[{"award-number":["2016R1A2B4013054"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The determination of fluid density and viscosity using most cantilever-based sensors is based on changes in resonant frequency and peak width. Here, we present a wave propagation analysis using piezoelectrically excited micro-cantilevers under distributed fluid loading. The standing wave shapes of microscale-thickness cantilevers partially immersed in liquids (water, 25% glycerol, and acetone), and nanoscale-thickness microfabricated cantilevers fully immersed in gases (air at three different pressures, carbon dioxide, and nitrogen) were investigated to identify the effects of fluid-structure interactions to thus determine the fluid properties. This measurement method was validated by comparing with the known fluid properties, which agreed well with the measurements. The relative differences for the liquids were less than 4.8% for the densities and 3.1% for the viscosities, and those for the gases were less than 6.7% for the densities and 7.3% for the viscosities, showing better agreements in liquids than in gases.<\/jats:p>","DOI":"10.3390\/s17112466","type":"journal-article","created":{"date-parts":[[2017,10,27]],"date-time":"2017-10-27T11:33:28Z","timestamp":1509104008000},"page":"2466","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":20,"title":["Determination of Fluid Density and Viscosity by Analyzing Flexural Wave Propagations on the Vibrating Micro-Cantilever"],"prefix":"10.3390","volume":"17","author":[{"given":"Deokman","family":"Kim","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, Hanyang University, Seoul 04763, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seongkyeol","family":"Hong","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7833-6925","authenticated-orcid":false,"given":"Jaesung","family":"Jang","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Junhong","family":"Park","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Hanyang University, Seoul 04763, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2017,10,27]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"24318","DOI":"10.3390\/s150924318","article-title":"Measurement and evaluation of the gas density and viscosity of pure gases and mixtures using a micro-cantilever beam","volume":"15","author":"Badarlis","year":"2015","journal-title":"Sensors"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1039\/C4LC00809J","article-title":"A cartridge based sensor array platform for multiple coagulation measurements from plasma","volume":"15","author":"Cakmak","year":"2015","journal-title":"Lab Chip"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.sna.2015.05.024","article-title":"Precision density and viscosity measurement using two cantilevers with different widths","volume":"232","author":"Cakmak","year":"2015","journal-title":"Sens. Actuators A Phys."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1016\/j.sna.2007.04.050","article-title":"Viscosity and density values from excitation level response of piezoelectric-excited cantilever sensors","volume":"138","author":"Wilson","year":"2007","journal-title":"Sens. Actuators A Phys."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1057","DOI":"10.1039\/b705787c","article-title":"Temperature dependence of viscosity and density of viscous liquids determined from thermal noise spectra of uncalibrated atomic force microscope cantilevers","volume":"7","author":"McLoughlin","year":"2007","journal-title":"Lab Chip"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1450","DOI":"10.1039\/b604842k","article-title":"Piezoresistive cantilever based nanoflow and viscosity sensor for microchannels","volume":"6","author":"Quist","year":"2006","journal-title":"Lab Chip"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"194102","DOI":"10.1063\/1.2200588","article-title":"Fluid viscosity determination by means of uncalibrated atomic force microscopy cantilevers","volume":"88","author":"Papi","year":"2006","journal-title":"Appl. Phys. Lett."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1016\/j.sna.2005.02.020","article-title":"Evaluation of a vibrating micromachined cantilever sensor for measuring the viscosity of complex organic liquids","volume":"123\u2013124","author":"Agoston","year":"2005","journal-title":"Sens. Actuators A Phys."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1497","DOI":"10.1063\/1.1287606","article-title":"Simultaneous liquid viscosity and density determination with piezoelectric unimorph cantilevers","volume":"89","author":"Shih","year":"2001","journal-title":"J. Appl. Phys."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"2487","DOI":"10.1063\/1.1150640","article-title":"Viscosity measurements based on experimental investigations of composite cantilever beam eigenfrequencies in viscous media","volume":"71","author":"Bergaud","year":"2000","journal-title":"Rev. Sci. Instrum."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1063\/1.368002","article-title":"Frequency response of cantilever beams immersed in viscous fluids with applications to the atomic force microscope","volume":"84","author":"Sader","year":"1998","journal-title":"J. Appl. Phys."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"63106","DOI":"10.1063\/1.4906613","article-title":"Simultaneous position and mass determination of a nanoscale-thickness cantilever sensor in viscous fluids","volume":"106","author":"Hong","year":"2015","journal-title":"Appl. Phys. Lett."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1007\/BF01540828","article-title":"Calculation of unsteady flows due to small motions of cylinders in a viscous fluid","volume":"3","author":"Tuck","year":"1969","journal-title":"J. Eng. Math."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Landau, L. (1987). Em Lifshitz Fluid Dynamics, Pergamon Press.","DOI":"10.1016\/B978-0-08-033933-7.50023-4"},{"key":"ref_15","unstructured":"Fahy, F.J. (2012). Sound and Structural Vibration: Radiation, Transmission and Response, Academic Press."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1016\/j.jsv.2004.12.019","article-title":"Transfer function methods to measure dynamic mechanical properties of complex structures","volume":"288","author":"Park","year":"2005","journal-title":"J. Sound Vib."},{"key":"ref_17","unstructured":"Lienhard, J.H. (2013). A Heat Transfer Textbook, Dover Publications."},{"key":"ref_18","unstructured":"Hinds, W.C. (2012). Aerosol Technology: Properties, Behavior, and Measurement of Airborne Particles, John Wiley & Sons."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"3285","DOI":"10.1021\/ie071349z","article-title":"Formula for the viscosity of a glycerol\u2014Water mixture","volume":"47","author":"Cheng","year":"2008","journal-title":"Ind. Eng. Chem. Res."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1457","DOI":"10.1021\/je020077y","article-title":"Densities and viscosities of acetone, diisopropyl ether, ethanol, and methyl ethyl ketone with a five-component hydrocarbon mixture from 288.15 k to 308.15 k","volume":"47","author":"Peng","year":"2002","journal-title":"J. Chem. Eng. Data"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"2132","DOI":"10.1177\/0954406213516438","article-title":"Damage identification using flexural vibration actuated and sensed by piezoelectric transducers","volume":"228","author":"Lee","year":"2014","journal-title":"Proc. Inst. Mech. Eng. Part C J. Mech. Eng. Sci."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/11\/2466\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T18:48:38Z","timestamp":1760208518000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/11\/2466"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,10,27]]},"references-count":21,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2017,11]]}},"alternative-id":["s17112466"],"URL":"https:\/\/doi.org\/10.3390\/s17112466","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,10,27]]}}}