{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,18]],"date-time":"2025-12-18T19:47:39Z","timestamp":1766087259906,"version":"build-2065373602"},"reference-count":20,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2017,12,5]],"date-time":"2017-12-05T00:00:00Z","timestamp":1512432000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Gas leak detection is an important issue in infrastructure monitoring and industrial production. In this context, infrared (IR) absorption spectroscopy is a major measurement method. It can be applied in an extractive or remote detection scheme. Tunable laser spectroscopy (TLS) instruments are able to detect CH4 leaks with column densities below 10 ppm\u00b7m from a distance of 30 m in less than a second. However, leak detection of non-IR absorbing gases such as N2 is not possible in this manner. Due to the fact that any leaking gas displaces or dilutes the surrounding background gas, an indirect detection is still possible. It is shown by sensitive TLS measurements of the ambient background concentration of O2 that N2 leaks can be localized with extractive and standoff methods for distances below 1 m. Minimum leak rates of 0.1 mbar\u00b7L\/s were determined. Flow simulations confirm that the leakage gas typically effuses in a narrow jet. The sensitivity is mainly determined by ambient flow conditions. Compared to TLS detection of CH4 at 1651 nm, the indirect method using O2 at 761 nm is experimentally found to be less sensitive by a factor of 100. However, the well-established TLS of O2 may become a universal tool for rapid leakage screening of vessels that contain unknown or inexpensive gases, such as N2.<\/jats:p>","DOI":"10.3390\/s17122804","type":"journal-article","created":{"date-parts":[[2017,12,5]],"date-time":"2017-12-05T11:50:28Z","timestamp":1512474628000},"page":"2804","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Gas Leak Detection by Dilution of Atmospheric Oxygen"],"prefix":"10.3390","volume":"17","author":[{"given":"Armin","family":"Lambrecht","sequence":"first","affiliation":[{"name":"Fraunhofer Institute for Physical Measurement Techniques IPM, Heidenhofstr. 8, D-79110 Freiburg, Germany"}]},{"given":"Eric","family":"Maier","sequence":"additional","affiliation":[{"name":"Fraunhofer Institute for Physical Measurement Techniques IPM, Heidenhofstr. 8, D-79110 Freiburg, Germany"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2575-1997","authenticated-orcid":false,"given":"Hans-Fridtjof","family":"Pernau","sequence":"additional","affiliation":[{"name":"Fraunhofer Institute for Physical Measurement Techniques IPM, Heidenhofstr. 8, D-79110 Freiburg, Germany"}]},{"given":"Thomas","family":"Strahl","sequence":"additional","affiliation":[{"name":"Fraunhofer Institute for Physical Measurement Techniques IPM, Heidenhofstr. 8, D-79110 Freiburg, Germany"}]},{"given":"Johannes","family":"Herbst","sequence":"additional","affiliation":[{"name":"Fraunhofer Institute for Physical Measurement Techniques IPM, Heidenhofstr. 8, D-79110 Freiburg, Germany"}]}],"member":"1968","published-online":{"date-parts":[[2017,12,5]]},"reference":[{"key":"ref_1","unstructured":"(2017, July 17). FLIR-GFx320-Datasheet. Available online: http:\/\/www.flir.com\/uploadedFiles\/Store\/Products\/OGI\/GFx320\/FLIR-GFx320-Datasheet-EN.pdf."},{"key":"ref_2","unstructured":"(2017, July 17). RMLD-IS Datasheet. Available online: http:\/\/www.sewerin.com\/cms\/fileadmin\/redakteure\/Prospekte\/pri_rmld-is_en.pdf."},{"key":"ref_3","unstructured":"(2017, October 04). Laser Methane Mini Datasheet. Available online: https:\/\/www.crowcon.com\/uk\/products\/portables\/LMm-Gen-2.html."},{"key":"ref_4","unstructured":"(2017, July 13). CHARM\u00ae\u2014Laser-Based System for Remote Gas Detection. Available online: https:\/\/www.open-grid-europe.com\/cps\/rde\/xbcr\/oge-internet\/20160122_OGE_Broschuere_Charm_ENG.pdf."},{"key":"ref_5","unstructured":"Fix, A., Ehret, G., Hoffstadt, A., Klingenberg, H.H., Lemmerz, C., Mahnke, P., Ulbricht, M., Wirth, M., Wittig, R., and Zirnig, W. (2004, January 12\u201316). Charm\u2014A helicopter-borne lidar system for pipeline monitoring. Proceedings of the 22nd International Laser Radar Conference, Matera, Italy."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"085202","DOI":"10.1088\/0957-0233\/27\/8\/085202","article-title":"\u2018Baseline-offset\u2019 scheme for a methane remote sensor based on wavelength modulation spectroscopy","volume":"27","author":"Ding","year":"2016","journal-title":"Meas. Sci. Technol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"095002","DOI":"10.1088\/0957-0233\/26\/9\/095002","article-title":"Gas leak localization and detection method based on a multi-point ultrasonic sensor array with TDOA algorithm","volume":"26","author":"Wang","year":"2015","journal-title":"Meas. Sci. Technol."},{"key":"ref_8","unstructured":"(2017, July 06). Leak Detection Compendium. Available online: http:\/\/pdf.directindustry.com\/pdf\/pfeiffer-vacuum\/leak-detection-compendium\/14656-537385.html."},{"key":"ref_9","unstructured":"Lambrecht, A. (2013). Device and Method for Detecting a Non-Infrared Active Target Gas in a Contactless Manner. (DE 10 2013 101 610 B4), German Patent."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"665","DOI":"10.1016\/S0022-4073(98)00078-8","article-title":"The Hitran Molecular Spectroscopic Database and Hawks (Hitran Atmospheric Workstation): 1996 Edition","volume":"60","author":"Rothman","year":"1998","journal-title":"J. Quant. Spectrosc. Radiat. Transf."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1007\/s00340-012-5228-x","article-title":"TDLAS-based open-path laser hygrometer using simple reflective foils as scattering targets","volume":"109","author":"Seidel","year":"2012","journal-title":"Appl. Phys. B"},{"key":"ref_12","unstructured":"(2017, July 13). LaserGas\u2122-III-SP-Oxygen-Analyzer. Available online: http:\/\/neomonitors.com\/wp-content\/uploads\/downloads\/2016\/06\/LaserGas%E2%84%A2-III-SP-Oxygen-Analyzer.pdf."},{"key":"ref_13","unstructured":"(2017, July 13). Oxygen Gas Sensor GPro 500. Available online: http:\/\/www.mt.com\/de\/en\/home\/products\/Process-Analytics\/gas-analyzer\/Tunable-Diode-Laser-TDL\/oxygen-sensor-GPro-500.html."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1007\/s003400050426","article-title":"Sensitive detection of methane with a 1.65 \u00b5m diode laser by photoacoustic and absorption spectroscopy","volume":"66","author":"Mashni","year":"1998","journal-title":"Appl. Phys. B"},{"key":"ref_15","unstructured":"(2017, October 06). COMSOL Blog. Available online: https:\/\/www.comsol.com\/blogs\/an-analysis-of-syngas-combustion-in-a-round-jet-burner\/."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1524\/teme.2012.0189","article-title":"IR Imaging of CO2: Basics, Experiments, and Applications","volume":"79","author":"Vollmer","year":"2012","journal-title":"TM Tech. Mess."},{"key":"ref_17","unstructured":"Herbst, J., Scherer, B., Steffen, M., Halford, B., and Lambrecht, A. (2009, January 26\u201328). Compact Multi Reflection Cells for Optical Gas Sensor Applications. Proceedings of the International Conference on Infrared Sensors & Systems IRS2, Nuremberg, Germany. Available online: https:\/\/www.ama-science.org\/proceedings\/getFile\/ZGpm."},{"key":"ref_18","unstructured":"(2017, July 17). LGR_Ultraportable_GGA_Datasheet. Available online: http:\/\/www.lgrinc.com\/documents\/LGR_Ultraportable_GGA_Datasheet.pdf."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"221106","DOI":"10.1063\/1.4922149","article-title":"Optical feedback cavity-enhanced absorption spectroscopy with a 3.24 \u00b5m interband cascade laser","volume":"106","author":"Manfred","year":"2015","journal-title":"Appl. Phys. Lett."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1007\/s00340-002-0984-7","article-title":"Handheld, battery-powered near-IR TDL sensor for stand-off detection of gas and vapor plumes","volume":"75","author":"Wainner","year":"2002","journal-title":"Appl. Phys. B"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/12\/2804\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T18:52:36Z","timestamp":1760208756000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/12\/2804"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,12,5]]},"references-count":20,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2017,12]]}},"alternative-id":["s17122804"],"URL":"https:\/\/doi.org\/10.3390\/s17122804","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2017,12,5]]}}}