{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T06:18:09Z","timestamp":1790835489070,"version":"4.1.0"},"reference-count":38,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2017,12,16]],"date-time":"2017-12-16T00:00:00Z","timestamp":1513382400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Spanish MINECO","award":["TEC2016-80063-C3-2-R"],"award-info":[{"award-number":["TEC2016-80063-C3-2-R"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Background: Modern Elekta Neuromag MEG devices include 102 sensor triplets containing one magnetometer and two planar gradiometers. The first processing step is often a signal space separation (SSS), which provides a powerful noise reduction. A question commonly raised by researchers and reviewers relates to which data should be employed in analyses: (1) magnetometers only, (2) gradiometers only, (3) magnetometers and gradiometers together. The MEG community is currently divided with regard to the proper answer. Methods: First, we provide theoretical evidence that both gradiometers and magnetometers result from the backprojection of the same SSS components. Then, we compare resting state and task-related sensor and source estimations from magnetometers and gradiometers in real MEG recordings before and after SSS. Results: SSS introduced a strong increase in the similarity between source time series derived from magnetometers and gradiometers (r2 = 0.3\u20130.8 before SSS and r2 &gt; 0.80 after SSS). After SSS, resting state power spectrum and functional connectivity, as well as visual evoked responses, derived from both magnetometers and gradiometers were highly similar (Intraclass Correlation Coefficient &gt; 0.8, r2 &gt; 0.8). Conclusions: After SSS, magnetometer and gradiometer data are estimated from a single set of SSS components (usually \u2264 80). Equivalent results can be obtained with both sensor types in typical MEG experiments.<\/jats:p>","DOI":"10.3390\/s17122926","type":"journal-article","created":{"date-parts":[[2017,12,19]],"date-time":"2017-12-19T03:54:32Z","timestamp":1513655672000},"page":"2926","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":117,"title":["Choice of Magnetometers and Gradiometers after Signal Space Separation"],"prefix":"10.3390","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4989-0123","authenticated-orcid":false,"given":"Pilar","family":"Garc\u00e9s","sequence":"first","affiliation":[{"name":"Laboratory of Cognitive and Computational Neuroscience (UCM-UPM), Centre for Biomedical Technology, 28223 Madrid, Spain"},{"name":"Biomedical Research Networking Center in Bioengineering Biomaterials and Nanomedicine (CIBER-BBN), Av. Monforte de Lemos 3-5, 28029 Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5294-4407","authenticated-orcid":false,"given":"David","family":"L\u00f3pez-Sanz","sequence":"additional","affiliation":[{"name":"Laboratory of Cognitive and Computational Neuroscience (UCM-UPM), Centre for Biomedical Technology, 28223 Madrid, Spain"},{"name":"Biomedical Research Networking Center in Bioengineering Biomaterials and Nanomedicine (CIBER-BBN), Av. Monforte de Lemos 3-5, 28029 Madrid, Spain"},{"name":"Department of Basic Psychology II, Faculty of Psychology, Universidad Complutense de Madrid, 28223 Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fernando","family":"Maest\u00fa","sequence":"additional","affiliation":[{"name":"Laboratory of Cognitive and Computational Neuroscience (UCM-UPM), Centre for Biomedical Technology, 28223 Madrid, Spain"},{"name":"Biomedical Research Networking Center in Bioengineering Biomaterials and Nanomedicine (CIBER-BBN), Av. Monforte de Lemos 3-5, 28029 Madrid, Spain"},{"name":"Department of Basic Psychology II, Faculty of Psychology, Universidad Complutense de Madrid, 28223 Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5965-164X","authenticated-orcid":false,"given":"Ernesto","family":"Pereda","sequence":"additional","affiliation":[{"name":"Laboratory of Cognitive and Computational Neuroscience (UCM-UPM), Centre for Biomedical Technology, 28223 Madrid, Spain"},{"name":"Department of Industrial Engineering, Instituto Universitario de Neurociencia, Universidad de La Laguna, 38205 Tenerife, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2017,12,16]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"124905","DOI":"10.1063\/1.1935742","article-title":"Presentation of electromagnetic multichannel data: The signal space separation method","volume":"97","author":"Taulu","year":"2005","journal-title":"J. Appl. Phys."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1759","DOI":"10.1088\/0031-9155\/51\/7\/008","article-title":"Spatiotemporal signal space separation method for rejecting nearby interference in MEG measurements","volume":"51","author":"Taulu","year":"2006","journal-title":"Phys. Med. Biol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"3359","DOI":"10.1109\/TSP.2005.853302","article-title":"Applications of the signal space separation method","volume":"53","author":"Taulu","year":"2005","journal-title":"IEEE Trans. Signal Process."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.clinph.2012.06.013","article-title":"Feasibility of clinical Magnetoencephalography (MEG) functional mapping in the presence of dental artefacts","volume":"124","author":"Hillebrand","year":"2013","journal-title":"Clin. Neurophysiol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"267","DOI":"10.3389\/fnins.2013.00267","article-title":"MEG and EEG data analysis with MNE-Python","volume":"7","author":"Gramfort","year":"2013","journal-title":"Front. Neurosci."},{"key":"ref_6","unstructured":"(2010). Elekta-Neuroscience MaxFilter User\u2019s Guide, Elektra Neuroscience. Software Version 2.2 2010."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1016\/j.neuroimage.2013.10.027","article-title":"MNE software for processing MEG and EEG data","volume":"86","author":"Gramfort","year":"2014","journal-title":"Neuroimage"},{"key":"ref_8","unstructured":"Elekta-Neuromag (2005). Elekta Neuromag\u00ae System Hardware User Manual, Elekta."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Malmivuo, J., and Plonsey, R. (1995). Magnetoencephalography. Bioelectromagnetism: Principles and Applications of Bioelectric and Biomagnetic Fields, Oxford University Press.","DOI":"10.1093\/acprof:oso\/9780195058239.001.0001"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"R51","DOI":"10.1088\/0953-2048\/15\/9\/201","article-title":"SQUID sensor array configurations for magnetoencephalography applications","volume":"15","author":"Vrba","year":"2002","journal-title":"Supercond. Sci. Technol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1016\/j.neuroimage.2014.12.040","article-title":"Automated model selection in covariance estimation and spatial whitening of MEG and EEG signals","volume":"108","author":"Engemann","year":"2015","journal-title":"Neuroimage"},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Gauss, C.F. (1877). Allgemeine Theorie des Erdmagnetismus. Werke, Springer.","DOI":"10.1007\/978-3-642-49319-5"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1109\/10.245606","article-title":"Sampling Theory for Neuromagnetic Detector Arrays","volume":"40","author":"Ahonen","year":"1993","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1089\/brain.2015.0416","article-title":"Quantifying the Test-Retest Reliability of Magnetoencephalography Resting-State Functional Connectivity","volume":"6","year":"2016","journal-title":"Brain Connect."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"156869","DOI":"10.1155\/2011\/156869","article-title":"FieldTrip: Open source software for advanced analysis of MEG, EEG, and invasive electrophysiological data","volume":"2011","author":"Oostenveld","year":"2011","journal-title":"Comput. Intell. Neurosci."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1016\/S0896-6273(02)00569-X","article-title":"Whole Brain Segmentation","volume":"33","author":"Fischl","year":"2002","journal-title":"Neuron"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"518","DOI":"10.1109\/TMI.2006.887364","article-title":"Geometrically accurate topology-correction of cortical surfaces using nonseparating loops","volume":"26","author":"Pacheco","year":"2007","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"867","DOI":"10.1109\/10.623056","article-title":"Localization of brain electrical activity via linearly constrained minimum variance spatial filtering","volume":"44","author":"Yuchtman","year":"1997","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1578","DOI":"10.1016\/j.neuroimage.2009.12.115","article-title":"Optimized beamforming for simultaneous MEG and intracranial local field potential recordings in deep brain stimulation patients","volume":"50","author":"Litvak","year":"2010","journal-title":"Neuroimage"},{"key":"ref_20","first-page":"171","article-title":"Inversion error, condition number, and approximate inverses of uncertain matrices","volume":"343","year":"2002","journal-title":"Linear Algebra Appl."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1037\/0033-2909.86.2.420","article-title":"Intraclass correlations: Uses in assessing rater reliability","volume":"86","author":"Shrout","year":"1979","journal-title":"Psychol. Bull."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Hunt, L.T., Woolrich, M.W., Rushworth, M.F.S., and Behrens, T.E.J. (2013). Trial-Type Dependent Frames of Reference for Value Comparison. PLoS Comput. Biol., 9.","DOI":"10.1371\/journal.pcbi.1003225"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"968","DOI":"10.1016\/j.neuroimage.2006.01.021","article-title":"An automated labeling system for subdividing the human cerebral cortex on MRI scans into gyral based regions of interest","volume":"31","author":"Desikan","year":"2006","journal-title":"Neuroimage"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1002\/hbm.23027","article-title":"Test-retest reliability of resting-state magnetoencephalography power in sensor and source space","volume":"37","year":"2016","journal-title":"Hum. Brain Mapp."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1037\/1040-3590.6.4.284","article-title":"Guidelines, criteria, and rules of thumb for evaluating normed and standardized assessment instruments in psychology","volume":"6","author":"Cicchetti","year":"1994","journal-title":"Psychol. Assess."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1016\/j.neuroimage.2015.09.018","article-title":"The Cambridge Centre for Ageing and Neuroscience (Cam-CAN) data repository: Structural and functional MRI, MEG, and cognitive data from a cross-sectional adult lifespan sample","volume":"144","author":"Taylor","year":"2017","journal-title":"Neuroimage"},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Shafto, M.A., Tyler, L.K., Dixon, M., Taylor, J.R., Rowe, J.B., Cusack, R., Calder, A.J., Marslen-Wilson, W.D., Duncan, J., and Dalgleish, T. (2014). The Cambridge Centre for Ageing and Neuroscience (Cam-CAN) study protocol: A cross-sectional, lifespan, multidisciplinary examination of healthy cognitive ageing. BMC Neurol., 14.","DOI":"10.1186\/s12883-014-0204-1"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"15671","DOI":"10.1038\/ncomms15671","article-title":"Age-related delay in visual and auditory evoked responses is mediated by white- and grey-matter differences","volume":"8","author":"Price","year":"2017","journal-title":"Nat. Commun."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"10046","DOI":"10.1038\/srep10046","article-title":"Early detection and late cognitive control of emotional distraction by the prefrontal cortex","volume":"5","year":"2015","journal-title":"Sci. Rep."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1007\/s10548-014-0364-8","article-title":"Inter- and intra-subject variability of neuromagnetic resting state networks","volume":"27","author":"Wens","year":"2014","journal-title":"Brain Topogr."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"3867","DOI":"10.1073\/pnas.1515657113","article-title":"Direction of information flow in large-scale resting-state networks is frequency-dependent","volume":"113","author":"Hillebrand","year":"2016","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1016\/j.neuroimage.2009.04.063","article-title":"MEG and EEG data fusion: Simultaneous localisation of face-evoked responses","volume":"47","author":"Henson","year":"2009","journal-title":"Neuroimage"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1186\/1477-044X-4-5","article-title":"Pseudo current density maps of electrophysiological heart, nerve or brain function and their physical basis","volume":"4","author":"Haberkorn","year":"2006","journal-title":"Biomagn. Res. Technol."},{"key":"ref_34","unstructured":"Sekihara, K., and Nagarajan, S.S. (2008). Adaptive Spatial Filters for Electromagnetic Brain Imaging, Springer."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"758973","DOI":"10.1155\/2011\/758973","article-title":"MEG\/EEG source reconstruction, statistical evaluation, and visualization with NUTMEG","volume":"2011","author":"Dalal","year":"2011","journal-title":"Comput. Intell. Neurosci."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1016\/S0074-7742(05)68006-3","article-title":"Beamformer Analysis of MEG Data","volume":"68","author":"Hillebrand","year":"2005","journal-title":"Int. Rev. Neurobiol."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"1788","DOI":"10.1016\/j.neuroimage.2007.09.050","article-title":"Optimising experimental design for MEG beamformer imaging","volume":"39","author":"Brookes","year":"2008","journal-title":"Neuroimage"},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Engemann, D., Strohmeier, D., Larson, E., and Gramfort, A. (2015, January 10\u201312). Mind the Noise Covariance When Localizing Brain Sources with M\/EEG. Proceedings of the 2015 International Workshop on Pattern Recognition in NeuroImaging (PRNI 2015), Stanford, CA, USA.","DOI":"10.1109\/PRNI.2015.25"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/12\/2926\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T18:54:16Z","timestamp":1760208856000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/17\/12\/2926"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,12,16]]},"references-count":38,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2017,12]]}},"alternative-id":["s17122926"],"URL":"https:\/\/doi.org\/10.3390\/s17122926","relation":{"has-preprint":[{"id-type":"doi","id":"10.20944\/preprints201710.0165.v1","asserted-by":"object"}]},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,12,16]]}}}