{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T06:15:42Z","timestamp":1781590542325,"version":"3.54.5"},"reference-count":56,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2018,2,28]],"date-time":"2018-02-28T00:00:00Z","timestamp":1519776000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The aim of this study was to investigate the reliability and concurrent validity of a commercially available Xsens MVN BIOMECH inertial-sensor-based motion capture system during clinically relevant functional activities. A clinician with no prior experience of motion capture technologies and an experienced clinical movement scientist each assessed 26 healthy participants within each of two sessions using a camera-based motion capture system and the MVN BIOMECH system. Participants performed overground walking, squatting, and jumping. Sessions were separated by 4 \u00b1 3 days. Reliability was evaluated using intraclass correlation coefficient and standard error of measurement, and validity was evaluated using the coefficient of multiple correlation and the linear fit method. Day-to-day reliability was generally fair-to-excellent in all three planes for hip, knee, and ankle joint angles in all three tasks. Within-day (between-rater) reliability was fair-to-excellent in all three planes during walking and squatting, and poor-to-high during jumping. Validity was excellent in the sagittal plane for hip, knee, and ankle joint angles in all three tasks and acceptable in frontal and transverse planes in squat and jump activity across joints. Our results suggest that the MVN BIOMECH system can be used by a clinician to quantify lower-limb joint angles in clinically relevant movements.<\/jats:p>","DOI":"10.3390\/s18030719","type":"journal-article","created":{"date-parts":[[2018,2,28]],"date-time":"2018-02-28T12:54:12Z","timestamp":1519822452000},"page":"719","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":271,"title":["Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity"],"prefix":"10.3390","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2806-0462","authenticated-orcid":false,"given":"Mohammad","family":"Al-Amri","sequence":"first","affiliation":[{"name":"School of Healthcare Sciences, College of Biomedical and Life Sciences, Cardiff University, Cardiff CF24 0AB, Wales, UK"},{"name":"Arthritis Research UK Biomechanics and Bioengineering Centre, Cardiff University, Cardiff CF10 3AXB, Wales, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin","family":"Nicholas","sequence":"additional","affiliation":[{"name":"School of Healthcare Sciences, College of Biomedical and Life Sciences, Cardiff University, Cardiff CF24 0AB, Wales, UK"},{"name":"Arthritis Research UK Biomechanics and Bioengineering Centre, Cardiff University, Cardiff CF10 3AXB, Wales, UK"},{"name":"Cardiff and Vale University Health Board, Heath Park, Cardiff CF14 4XW, Wales, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1073-9901","authenticated-orcid":false,"given":"Kate","family":"Button","sequence":"additional","affiliation":[{"name":"School of Healthcare Sciences, College of Biomedical and Life Sciences, Cardiff University, Cardiff CF24 0AB, Wales, UK"},{"name":"Arthritis Research UK Biomechanics and Bioengineering Centre, Cardiff University, Cardiff CF10 3AXB, Wales, UK"},{"name":"Cardiff and Vale University Health Board, Heath Park, Cardiff CF14 4XW, Wales, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Valerie","family":"Sparkes","sequence":"additional","affiliation":[{"name":"School of Healthcare Sciences, College of Biomedical and Life Sciences, Cardiff University, Cardiff CF24 0AB, Wales, UK"},{"name":"Arthritis Research UK Biomechanics and Bioengineering Centre, Cardiff University, Cardiff CF10 3AXB, Wales, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1502-764X","authenticated-orcid":false,"given":"Liba","family":"Sheeran","sequence":"additional","affiliation":[{"name":"School of Healthcare Sciences, College of Biomedical and Life Sciences, Cardiff University, Cardiff CF24 0AB, Wales, UK"},{"name":"Arthritis Research UK Biomechanics and Bioengineering Centre, Cardiff University, Cardiff CF10 3AXB, Wales, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7635-4815","authenticated-orcid":false,"given":"Jennifer","family":"Davies","sequence":"additional","affiliation":[{"name":"School of Healthcare Sciences, College of Biomedical and Life Sciences, Cardiff University, Cardiff CF24 0AB, Wales, UK"},{"name":"Arthritis Research UK Biomechanics and Bioengineering Centre, Cardiff University, Cardiff CF10 3AXB, Wales, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2018,2,28]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/j.ptsp.2011.07.001","article-title":"Physiotherapist agreement when visually rating movement quality during lower extremity functional screening tests","volume":"13","author":"Whatman","year":"2012","journal-title":"Phys. Ther. Sport"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1186\/1743-0003-3-4","article-title":"Gait analysis methods in rehabilitation","volume":"3","author":"Baker","year":"2006","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"8491","DOI":"10.3390\/s120708491","article-title":"Variable-state-dimension Kalman-based filter for orientation determination using inertial and magnetic sensors","volume":"12","author":"Sabatini","year":"2012","journal-title":"Sensors"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"9182","DOI":"10.3390\/s111009182","article-title":"Kalman-filter-based orientation determination using inertial\/magnetic sensors: Observability analysis and performance evaluation","volume":"11","author":"Sabatini","year":"2011","journal-title":"Sensors"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1007\/BF02345966","article-title":"Measuring orientation of human body segments using miniature gyroscopes and accelerometers","volume":"43","author":"Luinge","year":"2005","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"2330","DOI":"10.1016\/j.jbiomech.2009.06.025","article-title":"Functional calibration procedure for 3D knee joint angle description using inertial sensors","volume":"42","author":"Favre","year":"2009","journal-title":"J. Biomech."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1029","DOI":"10.1016\/j.jbiomech.2007.12.003","article-title":"Ambulatory measurement of 3D knee joint angle","volume":"41","author":"Favre","year":"2008","journal-title":"J. Biomech."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"588","DOI":"10.1016\/j.gaitpost.2008.04.003","article-title":"Joint kinematics estimate using wearable inertial and magnetic sensing modules","volume":"28","author":"Picerno","year":"2008","journal-title":"Gait Posture"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"978","DOI":"10.1016\/j.measurement.2009.02.002","article-title":"Development of a wearable sensor system for quantitative gait analysis","volume":"42","author":"Liu","year":"2009","journal-title":"Measurement"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s11517-009-0544-y","article-title":"First in vivo assessment of \u201coutwalk\u201d: A novel protocol for clinical gait analysis based on inertial and magnetic sensors","volume":"48","author":"Ferrari","year":"2010","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"6891","DOI":"10.3390\/s140406891","article-title":"IMU-based joint angle measurement for gait analysis","volume":"14","author":"Seel","year":"2014","journal-title":"Sensors"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1016\/j.gaitpost.2016.11.008","article-title":"25 years of lower limb joint kinematics by using inertial and magnetic sensors: A review of methodological approaches","volume":"51","author":"Picerno","year":"2017","journal-title":"Gait Posture"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1007\/s11517-012-1006-5","article-title":"Gait analysis in children with cerebral palsy via inertial and magnetic sensors","volume":"51","author":"Ferrari","year":"2013","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_14","first-page":"1","article-title":"Xsens MVN: Full 6DOF human motion tracking using miniature inertial sensors","volume":"8","author":"Roetenberg","year":"2009","journal-title":"Xsens Technol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"114501","DOI":"10.1115\/1.4000109","article-title":"Accuracy of Inertial Motion Sensors in Static, Quasistatic, and Complex Dynamic Motion","volume":"131","author":"Godwin","year":"2009","journal-title":"J. Biomech. Eng."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Lebel, K., Boissy, P., Hamel, M., and Duval, C. (2015). Inertial measures of motion for clinical biomechanics: Comparative assessment of accuracy under controlled conditions\u2014Changes in accuracy over time. PLoS ONE, 10.","DOI":"10.1371\/journal.pone.0118361"},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Lebel, K., Boissy, P., Hamel, M., and Duval, C. (2013). Inertial measures of motion for clinical biomechanics: Comparative assessment of accuracy under controlled conditions\u2014Effect of velocity. PLoS ONE, 8.","DOI":"10.1371\/journal.pone.0079945"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1007\/s11517-016-1537-2","article-title":"Validation of inertial measurement units with an optoelectronic system for whole-body motion analysis","volume":"55","author":"Mecheri","year":"2017","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Zhang, J.T., Novak, A.C., Brouwer, B., and Li, Q. (2013). Concurrent validation of Xsens MVN measurement of lower limb joint angular kinematics. Physiol. Meas., 34.","DOI":"10.1088\/0967-3334\/34\/8\/N63"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1002\/(SICI)1097-0258(19980115)17:1<101::AID-SIM727>3.0.CO;2-E","article-title":"Sample size and optimal designs for reliability studies","volume":"17","author":"Walter","year":"1998","journal-title":"Stat. Med."},{"key":"ref_21","unstructured":"Xsens Technologies B.V. (2017, June 28). MVN User Manual: User Guide MVN, MVN BIOMECH MVN Link, MVN Awinda. Available online: https:\/\/fccid.io\/QILMTW2-3A7G6\/User-Manual\/Users-Manual-2695756."},{"key":"ref_22","unstructured":"(2018, February 27). Vicon Motion System. Plug-in Gait Product Guide\u2014Foundation Notes Revision 2.0. Available online: https:\/\/www.vicon.com\/downloads\/documentation\/plug-in-gait-product-guide."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1257","DOI":"10.1016\/0021-9290(95)00017-C","article-title":"ISB Recommendations in the Reporting for Standardization of Kinematic Data","volume":"28","author":"Wu","year":"1995","journal-title":"J. Biomech."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1115\/1.3138397","article-title":"A Joint Coordinate System for the Clinical Description of Three-Dimensional Motions: Application to the Knee","volume":"105","author":"Grood","year":"1983","journal-title":"J. Biomech. Eng."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"849","DOI":"10.1002\/jor.1100070611","article-title":"Repeatability of Kinematic, Kinetic, and EMG Data in Normal Adult Gait.pdf","volume":"7","author":"Kadaba","year":"1989","journal-title":"J. Orthop. Res."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1002\/jor.1100080310","article-title":"Measurement of lower extremity kinematics during level walking","volume":"8","author":"Kadaba","year":"1990","journal-title":"J. Orthop. Res."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1016\/0167-9457(91)90046-Z","article-title":"A gait analysis data collection and reduction technique","volume":"10","author":"Davis","year":"1991","journal-title":"Hum. Mov. Sci."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1016\/j.clinbiomech.2013.11.010","article-title":"Activity progression for anterior cruciate ligament injured individuals","volume":"29","author":"Button","year":"2014","journal-title":"Clin. Biomech."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Roos, P.E., Button, K., and Van Deursen, R.W.M. (2014). Motor control strategies during double leg squat following anterior cruciate ligament rupture and reconstruction: An observational study. J. Neuroeng. Rehabil., 11.","DOI":"10.1186\/1743-0003-11-19"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"675","DOI":"10.1016\/j.jbiomech.2013.11.046","article-title":"Altered biomechanical strategies and medio-lateral control of the knee represent incomplete recovery of individuals with injury during single leg hop","volume":"47","author":"Roos","year":"2014","journal-title":"J. Biomech."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1016\/j.ptsp.2008.03.001","article-title":"Recovery in functional non-copers following anterior cruciate ligament rupture as detected by gait kinematics","volume":"9","author":"Button","year":"2008","journal-title":"Phys. Ther. Sport"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"710","DOI":"10.1016\/j.gaitpost.2007.07.007","article-title":"Two simple methods for determining gait events during treadmill and overground walking using kinematic data","volume":"27","author":"Zeni","year":"2008","journal-title":"Gait Posture"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1590\/bjpt-rbf.2014.0143","article-title":"The COnsensus-based standards for the selection of health measurement INstruments (COSMIN) and how to select an outcome measurement instrument","volume":"20","author":"Mokkink","year":"2016","journal-title":"Braz. J. Phys. Ther."},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Mokkink, L.B., Terwee, C.B., Knol, D.L., Stratford, P.W., Alonso, J., Patrick, D.L., Bouter, L.M., and De Vet, H.C.W. (2006). Protocol of the COSMIN study: COnsensus-based Standards for the selection of health Measurement INstruments. BMC Med. Res. Methodol., 6.","DOI":"10.1186\/1471-2288-6-2"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1037\/0033-2909.86.2.420","article-title":"Intraclass correlations: Uses in assessing rater reliability","volume":"86","author":"Shrout","year":"1979","journal-title":"Psychol. Bull."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1016\/S0031-9406(05)61211-4","article-title":"Reliability: What is it, and how is it measured?","volume":"86","author":"Bruton","year":"2000","journal-title":"Physiotherapy"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"217","DOI":"10.2165\/00007256-199826040-00002","article-title":"Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine","volume":"26","author":"Atkinson","year":"1998","journal-title":"Sport. Med."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1016\/j.gaitpost.2008.09.003","article-title":"The reliability of three-dimensional kinematic gait measurements: A systematic review","volume":"29","author":"McGinley","year":"2009","journal-title":"Gait Posture"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1016\/j.gaitpost.2010.02.009","article-title":"A new formulation of the coefficient of multiple correlation to assess the similarity of waveforms measured synchronously by different motion analysis protocols","volume":"31","author":"Ferrari","year":"2010","journal-title":"Gait Posture"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"2014","DOI":"10.1016\/j.jbiomech.2012.05.014","article-title":"Evaluating the properties of the coefficient of multiple correlation (CMC) for kinematic gait data","volume":"45","author":"Skare","year":"2012","journal-title":"J. Biomech."},{"key":"ref_41","doi-asserted-by":"crossref","unstructured":"Iosa, M., Cereatti, A., Merlo, A., Campanini, I., Paolucci, S., and Cappozzo, A. (2014). Assessment of waveform similarity in clinical gait data: The linear fit method. Biomed Res. Int., 2014.","DOI":"10.1155\/2014\/214156"},{"key":"ref_42","doi-asserted-by":"crossref","unstructured":"Al-Amri, M., Al Balushi, H., and Mashabi, A. (2017). Intra-rater repeatability of gait parameters in healthy adults during self-paced treadmill-based virtual reality walking. Comput. Methods Biomech. Biomed. Eng., 1\u20139.","DOI":"10.1080\/10255842.2017.1404994"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1016\/j.gaitpost.2016.07.075","article-title":"Reliability of 3D gait data across multiple laboratories","volume":"49","author":"Kaufman","year":"2016","journal-title":"Gait Posture"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1016\/j.gaitpost.2011.09.105","article-title":"Reliability and minimal detectible change values for gait kinematics and kinetics in healthy adults","volume":"35","author":"Wilken","year":"2012","journal-title":"Gait Posture"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/j.gaitpost.2003.09.004","article-title":"Repeatability of an optimised lower body model","volume":"20","author":"Charlton","year":"2004","journal-title":"Gait Posture"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1016\/j.gaitpost.2013.07.130","article-title":"Test-retest reliability of three dimensional gait analysis: Including a novel approach to visualising agreement of gait cycle waveforms with Bland and Altman plots","volume":"39","author":"Meldrum","year":"2014","journal-title":"Gait Posture"},{"key":"ref_47","first-page":"37","article-title":"Reliability and accuracy of a goniometer mobile device application for video measurement of the functional movement screen deep squat test","volume":"10","author":"Krause","year":"2015","journal-title":"Int. J. Sports Phys. Ther."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"2021","DOI":"10.1249\/mss.0b013e318149332d","article-title":"Reliability of landing 3D motion analysis: Implications for longitudinal analyses","volume":"39","author":"Ford","year":"2007","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1016\/j.gaitpost.2016.03.003","article-title":"Reliability of knee biomechanics during a vertical drop jump in elite female athletes","volume":"46","author":"Mok","year":"2016","journal-title":"Gait Posture"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.1177\/0363546508314425","article-title":"Effect of a neuromuscular training program on the kinetics and kinematics of jumping tasks","volume":"36","author":"Chappell","year":"2008","journal-title":"Am. J. Sports Med."},{"key":"ref_51","unstructured":"Kirtley, C. (2002, January 10\u201312). Sensitivity of the modified helen hayes model to marker placement errors. Proceedings of the Seventh International Symposium on the 3-D Analysis of Human Movement, Newcastle, UK."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1016\/j.gaitpost.2004.05.002","article-title":"Human movement analysis using stereophotogrammetry Part 3. Soft tissue artifact assessment and compensation","volume":"21","author":"Leardini","year":"2005","journal-title":"Gait Posture"},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"1029","DOI":"10.1016\/S0021-9290(00)00056-7","article-title":"Measurement of the screw-home motion of the knee is sensitive to errors in axis alignment","volume":"33","author":"Piazza","year":"2000","journal-title":"J. Biomech."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1016\/j.gaitpost.2007.11.009","article-title":"Quantitative comparison of five current protocols in gait analysis","volume":"28","author":"Ferrari","year":"2008","journal-title":"Gait Posture"},{"key":"ref_55","unstructured":"Baker, R. (2013). Measuring Walking: A Handbook of Clinical Gait Analysis, Mac Keith Press."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1016\/0268-0033(95)91394-T","article-title":"Position and orientation in space of bones during movement: Anatomical frame definition and determination","volume":"10","author":"Cappozzo","year":"1995","journal-title":"Clin. Biomech."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/3\/719\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T14:56:53Z","timestamp":1760194613000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/3\/719"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,2,28]]},"references-count":56,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2018,3]]}},"alternative-id":["s18030719"],"URL":"https:\/\/doi.org\/10.3390\/s18030719","relation":{"is-referenced-by":[{"id-type":"doi","id":"10.1038\/s41597-022-01690-y","asserted-by":"object"}]},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,2,28]]}}}