{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T17:50:36Z","timestamp":1790704236055,"version":"4.1.0"},"reference-count":30,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2018,4,25]],"date-time":"2018-04-25T00:00:00Z","timestamp":1524614400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"the National Key Research and Development Project","award":["2016YFC0101900"],"award-info":[{"award-number":["2016YFC0101900"]}]},{"name":"the National Key Research and Development Project","award":["2016YFC0105004"],"award-info":[{"award-number":["2016YFC0105004"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Currently, breast cancer is one of the most common cancers in women all over the world. A novel 3D breast ultrasound imaging ring system using the linear array transducer is proposed to decrease costs, reduce processing difficulties, and improve patient comfort as compared to modern day breast screening systems. The 1 \u00d7 128 Piezoelectric Micromachined Ultrasonic Transducer (PMUT) linear array is placed 90 degrees cross-vertically. The transducer surrounds the mammary gland, which allows for non-contact detection. Once the experimental platform is built, the breast model is placed through the electric rotary table opening and into a water tank that is at a constant temperature of 32 \u00b0C. The electric rotary table performs a 360\u00b0 scan either automatically or mechanically. Pulse echo signals are captured through a circular scanning method at discrete angles. Subsequently, an ultrasonic tomography algorithm is designed, and a horizontal slice imaging is realized. The experimental results indicate that the preliminary detection of mass is realized by using this ring system. Circular scanning imaging is obtained by using a rotatable linear array instead of a cylindrical array, which allows the size and location of the mass to be recognized. The resolution of breast imaging is improved through the adjustment of the angle interval (&gt;0.05\u00b0) and multiple slices are gained through different transducer array elements (1 \u00d7 128). These results validate the feasibility of the system design as well as the algorithm, and encourage us to implement our concept with a clinical study in the future.<\/jats:p>","DOI":"10.3390\/s18051332","type":"journal-article","created":{"date-parts":[[2018,4,25]],"date-time":"2018-04-25T11:15:39Z","timestamp":1524654939000},"page":"1332","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":27,"title":["The Application of an Ultrasound Tomography Algorithm in a Novel Ring 3D Ultrasound Imaging System"],"prefix":"10.3390","volume":"18","author":[{"given":"Chang","family":"Liu","sequence":"first","affiliation":[{"name":"Key Laboratory of Instrumentation Science &amp; Dynamic Measurement, North University of China, Ministry of Education, Taiyuan 030051, China"},{"name":"Science and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan 030051, China"},{"name":"School of Electrical and Electronic Engineering, Dalian Vocational Technical College, Dalian 116037, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chenyang","family":"Xue","sequence":"additional","affiliation":[{"name":"Key Laboratory of Instrumentation Science &amp; Dynamic Measurement, North University of China, Ministry of Education, Taiyuan 030051, China"},{"name":"Science and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan 030051, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Binzhen","family":"Zhang","sequence":"additional","affiliation":[{"name":"Key Laboratory of Instrumentation Science &amp; Dynamic Measurement, North University of China, Ministry of Education, Taiyuan 030051, China"},{"name":"Science and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan 030051, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guojun","family":"Zhang","sequence":"additional","affiliation":[{"name":"Key Laboratory of Instrumentation Science &amp; Dynamic Measurement, North University of China, Ministry of Education, Taiyuan 030051, China"},{"name":"Science and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan 030051, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Changde","family":"He","sequence":"additional","affiliation":[{"name":"Key Laboratory of Instrumentation Science &amp; Dynamic Measurement, North University of China, Ministry of Education, Taiyuan 030051, China"},{"name":"Science and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan 030051, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2018,4,25]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"7011","DOI":"10.1088\/1361-6560\/aa7e5a","article-title":"Ultrasonic computed tomography based on full-waveform inversion for bone quantitative imaging","volume":"62","author":"Bernard","year":"2017","journal-title":"Phys. Med. Biol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1108\/SR-05-2015-0076","article-title":"Design of capacitive micromachined ultrasonic transducer (CMUT) linear array for underwater imaging","volume":"36","author":"Zhang","year":"2016","journal-title":"Sens. Rev."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1016\/S0720-048X(12)70055-4","article-title":"3D ultrasound computer tomography of the breast: A new era?","volume":"1","author":"Ruiter","year":"2012","journal-title":"Eur. J. Radiol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1016\/j.compmedimag.2014.10.005","article-title":"Image fusion of Ultrasound Computer Tomography volumes with X-ray mammograms using a biomechanical model based 2D\/3D registration","volume":"40","author":"Hopp","year":"2015","journal-title":"Comput. Med. Imaging Graph."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Duric, N., Littrup, P., Roy, O., Schmidt, S., Li, C., Bey-Knight, L., and Chen, X. (2013, January 21\u201325). Breast Imaging with Ultrasound Tomography: Initial results with SoftVue. Proceedings of the 2013 IEEE International Ultrasonics Symposium (IUS), Prague, Czech Republic.","DOI":"10.1109\/ULTSYM.2013.0099"},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Duric, N., Littrup, P., Li, C., Roy, O., Bey-Knight, L., Janer, R., Kunz, D., Chen, X., Goll, J., and Wallen, A. (2013, January 29). Breast imaging with the SoftVue imaging system: First results. Proceedings of the Ultrasonic Imaging, Tomography, and Therapy, Lake Buena Vista, FL, USA.","DOI":"10.1117\/12.2002513"},{"key":"ref_7","first-page":"68","article-title":"Hybrid-array-based optoacoustic and ultrasound (OPUS) imaging of biological tissues","volume":"110","author":"Razansky","year":"2017","journal-title":"Appl. Phys. Lett."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Zhang, X., Fincke, J., Kuzmin, A., Lempitsky, V., and Anthony, B. (2015, January 25\u201329). A single element 3D ultrasound tomography system. Proceedings of the 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Milan, Italy.","DOI":"10.1109\/EMBC.2015.7319647"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Wiskin, J., Borup, D., Johnson, S., Andre, M., Greenleaf, J., Parisky, Y., and Klock, J. (2013, January 2\u20136). Three-dimensional nonlinear inverse scattering: Quantitative transmission algorithms, refraction corrected reflection, scanner design and clinical results. Proceedings of the Meetings on Acoustics, Acoustical Society of America, San Francisco, CA, USA.","DOI":"10.1121\/1.4800267"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1109\/TUFFC.2014.006494","article-title":"An ultrasound tomography system with polyvinyl alcohol (PVA) moldings for coupling: In vivo results for 3-D pulse-echo imaging of the female breast","volume":"62","author":"Koch","year":"2015","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Yu, S., Wu, S., Zhuang, L., Wei, X., Sak, M., Neb, D., Hu, J., and Xie, Y. (2017). Efficient Segmentation of a Breast in B-Mode Ultrasound Tomography Using Three-Dimensional GrabCut (GC3D). Sensors, 17.","DOI":"10.3390\/s17081827"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"3802","DOI":"10.1121\/1.3699240","article-title":"Non-linear inverse scattering: High resolution quantitative breast tissue tomography","volume":"131","author":"Wiskin","year":"2012","journal-title":"J. Acoust. Soc. Am."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"5381","DOI":"10.1088\/0031-9155\/60\/14\/5381","article-title":"Frequency Domain Ultrasound Waveform Tomography: Breast Imaging Using a Ring Transducer","volume":"60","author":"Sandhu","year":"2015","journal-title":"Phys. Med. Biol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1651","DOI":"10.1109\/TUFFC.2015.007058","article-title":"Hybrid optoacoustic tomography and pulse-echo ultrasonography using concave arrays","volume":"62","author":"Jeng","year":"2015","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"2651","DOI":"10.1109\/TUFFC.2008.980","article-title":"Forward-looking intracardiac ultrasound imaging using a 1-D CMUT array integrated with custom front-end electronics","volume":"55","author":"Nikoozadeh","year":"2008","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_16","first-page":"S105","article-title":"An investigation on attenuation UCT with wave paths enhancement for breast ultrasound","volume":"7","author":"Member","year":"2013","journal-title":"IEEJ Trans. Electr. Electron. Eng."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1389","DOI":"10.7863\/jum.2012.31.9.1389","article-title":"Imaging of sound speed using reflection ultrasound tomography","volume":"31","author":"Nebeker","year":"2012","journal-title":"J. Ultrasound Med."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Johnson, S.A., Abbott, T., Bell, R., Berggren, M., Borup, D., Robinson, D., Wiskin, J., Olsen, S., and Hanover, B. (2007). Non-Invasive Breast Tissue Characterization Using Ultrasound Speed and Attenuation. Acoustical Imaging, Springer.","DOI":"10.1007\/1-4020-5721-0_17"},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Greenleaf, J.F., Johnson, S.A., Lee, S.L., Herman, G.T., and Wood, E.H. (1974). Algebraic reconstruction of spatial distributions of acoustic velocities in tissue from their time of flight profiles. Acoustical Holography, Plenum Press.","DOI":"10.1007\/978-1-4615-8216-8_4"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1088\/1361-6560\/aa51ab","article-title":"Ultrasonic computed tomography imaging of iron oxide nanoparticles","volume":"62","author":"Perlman","year":"2017","journal-title":"Phys. Med. Biol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"8020","DOI":"10.3390\/s150408020","article-title":"Piezoelectric Micromachined Ultrasound Transducer (PMUT) Arrays for Integrated Sensing, Actuation and Imaging","volume":"15","author":"Qiu","year":"2015","journal-title":"Sensors"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Rui, Z., Zhang, W., He, C., Zhang, Y., Song, J., and Xue, C. (2016). Underwater Imaging Using a 1 \u00d7 16 CMUT Linear Array. Sensors, 16.","DOI":"10.3390\/s16030312"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"4643","DOI":"10.1364\/OL.40.004643","article-title":"Whole-body live mouse imaging by hybrid reflection-mode ultrasound and optoacoustic tomography","volume":"40","author":"Razansky","year":"2015","journal-title":"Opt. Lett."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1457","DOI":"10.1109\/TUFFC.2012.2346","article-title":"Conformal ultrasound imaging system for anatomical breast inspection","volume":"59","author":"Rouyer","year":"2012","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"07JF07","DOI":"10.7567\/JJAP.56.07JF07","article-title":"Highly precise acoustic calibration method of ring-shaped ultrasound transducer array for plane-wave-based ultrasound tomography","volume":"56","author":"Terada","year":"2017","journal-title":"Jpn. J. Appl. Phys."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1109\/TUFFC.2014.006788","article-title":"Waveform inversion with source encoding for breast sound speed reconstruction in ultrasound computed tomography","volume":"62","author":"Wang","year":"2015","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_27","first-page":"143","article-title":"Multi-element synthetic aperture focusing photoacoustic imaging, system with real-time digital beamformer technique","volume":"52","author":"Yang","year":"2010","journal-title":"Eur. Phys. J. Appl. Phys."},{"key":"ref_28","unstructured":"Zhang, W., Hoorfar, A., and Thajudeen, C. (2011, January 3\u20138). Three-dimensional intra-wall characterization with linear inverse scattering algorithm. Proceedings of the 2011 IEEE International Symposium on Antennas and Propagation (APSURSI), Spokane, WA, USA."},{"key":"ref_29","unstructured":"He, W. (2014). Digital Ultrasonic Imaging Principle and Architecture System Design, Science Press."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"36010","DOI":"10.1117\/1.JBO.21.3.036010","article-title":"Delay-multiply-and-sum-based synthetic aperture focusing in photoacoustic microscopy","volume":"21","author":"Park","year":"2016","journal-title":"J. Biomed. Opt."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/5\/1332\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T15:02:07Z","timestamp":1760194927000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/5\/1332"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,4,25]]},"references-count":30,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2018,5]]}},"alternative-id":["s18051332"],"URL":"https:\/\/doi.org\/10.3390\/s18051332","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,4,25]]}}}