{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T03:59:13Z","timestamp":1760241553273,"version":"build-2065373602"},"reference-count":28,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2018,5,2]],"date-time":"2018-05-02T00:00:00Z","timestamp":1525219200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The intracardiac electrical activation maps are commonly used as a guide in the ablation of cardiac arrhythmias. The use of catheters with force sensors has been proposed in order to know if the electrode is in contact with the tissue during the registration of intracardiac electrograms (EGM). Although threshold criteria on force signals are often used to determine the catheter contact, this may be a limited criterion due to the complexity of the heart dynamics and cardiac vorticity. The present paper is devoted to determining the criteria and force signal profiles that guarantee the contact of the electrode with the tissue. In this study, we analyzed 1391 force signals and their associated EGM recorded during 2 and 8 s, respectively, in 17 patients (82 \u00b1 60 points per patient). We aimed to establish a contact pattern by first visually examining and classifying the signals, according to their likely-contact joint profile and following the suggestions from experts in the doubtful cases. First, we used Principal Component Analysis to scrutinize the force signal dynamics by analyzing the main eigen-directions, first globally and then grouped according to the certainty of their tissue-catheter contact. Second, we used two different linear classifiers (Fisher discriminant and support vector machines) to identify the most relevant components of the previous signal models. We obtained three main types of eigenvectors, namely, pulsatile relevant, non-pulsatile relevant, and irrelevant components. The classifiers reached a moderate to sufficient discrimination capacity (areas under the curve between 0.84 and 0.95 depending on the contact certainty and on the classifier), which allowed us to analyze the relevant properties in the force signals. We conclude that the catheter-tissue contact profiles in force recordings are complex and do not depend only on the signal intensity being above a threshold at a single time instant, but also on time pulsatility and trends. These findings pave the way towards a subsystem which can be included in current intracardiac navigation systems assisted by force contact sensors, and it can provide the clinician with an estimate of the reliability on the tissue-catheter contact in the point-by-point EGM acquisition procedure.<\/jats:p>","DOI":"10.3390\/s18051399","type":"journal-article","created":{"date-parts":[[2018,5,3]],"date-time":"2018-05-03T03:20:27Z","timestamp":1525317627000},"page":"1399","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Force Trends and Pulsatility for Catheter Contact Identification in Intracardiac Electrograms during Arrhythmia Ablation"],"prefix":"10.3390","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5958-6606","authenticated-orcid":false,"given":"David","family":"Rivas-Lalaleo","sequence":"first","affiliation":[{"name":"Departamento de El\u00e9ctrica y Electr\u00f3nica, Universidad de las Fuerzas Armadas ESPE, Av. General Rumi\u00f1ahui s\/n, 170501 Sangolqu\u00ed, Ecuador"},{"name":"Department of Signal Theory and Communications and Telematic Systems and Computation, Rey Juan Carlos University, Fuenlabrada, 28943 Madrid, Spain"}]},{"given":"Sergio","family":"Mu\u00f1oz-Romero","sequence":"additional","affiliation":[{"name":"Department of Signal Theory and Communications and Telematic Systems and Computation, Rey Juan Carlos University, Fuenlabrada, 28943 Madrid, Spain"},{"name":"Center for Computational Simulation, Universidad Polit\u00e9cnica de Madrid; Boadilla, 28223 Madrid, Spain"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4435-7987","authenticated-orcid":false,"given":"M\u00f3nica","family":"Huerta","sequence":"additional","affiliation":[{"name":"Universidad Polit\u00e9cnica Salesiana, 010105 Cuenca, Ecuador"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2196-3514","authenticated-orcid":false,"given":"Mayra","family":"Erazo-Rodas","sequence":"additional","affiliation":[{"name":"Departamento de El\u00e9ctrica y Electr\u00f3nica, Universidad de las Fuerzas Armadas ESPE, Av. General Rumi\u00f1ahui s\/n, 170501 Sangolqu\u00ed, Ecuador"}]},{"given":"Juan Jos\u00e9","family":"S\u00e1nchez-Mu\u00f1oz","sequence":"additional","affiliation":[{"name":"Arrhythmia Unit, University Clinic Hospital Virgen de la Arrixaca, El Palmar, 30120 Murcia, Spain"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0426-8912","authenticated-orcid":false,"given":"Jos\u00e9 Luis","family":"Rojo-\u00c1lvarez","sequence":"additional","affiliation":[{"name":"Department of Signal Theory and Communications and Telematic Systems and Computation, Rey Juan Carlos University, Fuenlabrada, 28943 Madrid, Spain"},{"name":"Center for Computational Simulation, Universidad Polit\u00e9cnica de Madrid; Boadilla, 28223 Madrid, Spain"}]},{"given":"Arcadi","family":"Garc\u00eda-Alberola","sequence":"additional","affiliation":[{"name":"Arrhythmia Unit, University Clinic Hospital Virgen de la Arrixaca, El Palmar, 30120 Murcia, Spain"}]}],"member":"1968","published-online":{"date-parts":[[2018,5,2]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Al-Khatib, S.M., Stevenson, W.G., Ackerman, M.J., Bryant, W.J., Callans, D.J., Curtis, A.B., Deal, B.J., Dickfeld, T., Field, M.E., and Fonarow, G.C. (2017). 2017 AHA\/ACC\/HRS Guideline for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death: Executive Summary. Circulation.","DOI":"10.1016\/j.hrthm.2017.10.035"},{"key":"ref_2","first-page":"1609","article-title":"2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS","volume":"18","author":"Kirchhof","year":"2016","journal-title":"EP Eur."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1016\/j.ijcard.2017.06.073","article-title":"Impact of atrial arrhythmias on outcome in adults with congenital heart disease","volume":"248","author":"Yang","year":"2017","journal-title":"Int. J. Cardiol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/j.ijcard.2017.08.029","article-title":"Atrial arrhythmias in adults with congenital heart disease. Listening to your heart sound can save your life","volume":"248","author":"Limongelli","year":"2017","journal-title":"Int. J. Cardiol."},{"key":"ref_5","unstructured":"Peters, N. (2000). Arrhythmogenic mechanisms: Automaticity, triggered activity, and reentry. Cardiac Electrophysiology: From Cell to Bedside, Saunders."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Li, H., Yuan, D., Wang, Y., Cui, D., and Cao, L. (2016). Arrhythmia Classification Based on Multi-Domain Feature Extraction for an ECG Recognition System. Sensors, 16.","DOI":"10.3390\/s16101744"},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Garc\u00eda Iglesias, D., Roque\u00f1i Guti\u00e9rrez, N., De Cos, F.J., and Calvo, D. (2018). Analysis of the High-Frequency Content in Human QRS Complexes by the Continuous Wavelet Transform: An Automatized Analysis for the Prediction of Sudden Cardiac Death. Sensors, 18.","DOI":"10.3390\/s18020560"},{"key":"ref_8","first-page":"1273","article-title":"Spanish Registry on Catheter Ablation. 1st Official Report of the Working Group on Electrophysiology and Arrhythmias of the Spanish Society of Cardiology (Year 2001)","volume":"55","author":"Merino","year":"2002","journal-title":"Revista Espa\u00f1ola de Cardiolog\u00eda"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1016\/j.ijcard.2017.06.115","article-title":"Catheter ablation of accessory pathway: 14-year trends in utilization and complications in adults in the United States","volume":"248","author":"Garg","year":"2017","journal-title":"Int. J. Cardiol."},{"key":"ref_10","first-page":"402","article-title":"Ablaci\u00f3n por radiofrecuencia para el tratamiento de las arritmias card\u00edacas en 500 pacientes consecutivos","volume":"71","author":"Helguera","year":"2003","journal-title":"Rev. Argent. Cardiol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"12844","DOI":"10.3390\/s120912844","article-title":"A Real-Time Cardiac Arrhythmia Classification System with Wearable Sensor Networks","volume":"12","author":"Hu","year":"2012","journal-title":"Sensors"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1016\/S0300-8932(04)77184-5","article-title":"Ventricular Tachycardia Ablation Guided by LocaLisa System in Patients With Structural Heart Disease","volume":"57","author":"Abello","year":"2004","journal-title":"Revista Espa\u00f1ola de Cardiolog\u00eda"},{"key":"ref_13","first-page":"159","article-title":"Usefulness of the Contact Force Sensing Catheter to Assess the Areas of Myocardial Scar in Patients With Ventricular Tachycardia","volume":"68","year":"2015","journal-title":"Revista Espa\u00f1ola de Cardiolog\u00eda"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1111\/jce.13100","article-title":"Fiberoptic Contact-Force Sensing Electrophysiological Catheters: How Precise Is the Technology?","volume":"28","author":"Bourier","year":"2017","journal-title":"J. Cardiovasc. Electrophysiol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"2301","DOI":"10.1109\/TBME.2016.2525929","article-title":"Design and Evaluation of a Catheter Contact-Force Controller for Cardiac Ablation Therapy","volume":"63","author":"Gelman","year":"2016","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1224","DOI":"10.1111\/jce.12762","article-title":"Safety and clinical outcome of catheter ablation of ventricular arrhythmias using contact force sensing: Consecutive case series","volume":"26","author":"Hendriks","year":"2015","journal-title":"J. Cardiovasc. Electrophysiol."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1111\/jce.13179","article-title":"Persistent Atrial Fibrillation Ablation With or Without Contact Force Sensing","volume":"28","author":"Hussein","year":"2017","journal-title":"J. Cardiovasc. Electrophysiol."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Tang, Y., Mackey, I., and Su, J. (2018). Querying Workflow Logs. Information, 9.","DOI":"10.3390\/info9020025"},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Madhikermi, M., Buda, A., Dave, B., and Fr\u00e4mling, K. (2017, January 18\u201320). Data Model Logger\u2014Data Discovery for Extract- Transform-Load. Proceedings of the 2017 IEEE 19th International Conference on High Performance Computing and Communications; IEEE 15th International Conference on Smart City; IEEE 3rd International Conference on Data Science and Systems (HPCC\/SmartCity\/DSS), Bangkok, Thailand.","DOI":"10.1109\/HPCC-SmartCity-DSS.2017.87"},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Quiroga, J., Mujica, L., Villamizar, R., Ruiz, M., and Camacho, J. (2017). PCA Based Stress Monitoring of Cylindrical Specimens Using PZTs and Guided Waves. Sensors, 17.","DOI":"10.3390\/s17122788"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"625","DOI":"10.1016\/j.neucom.2015.07.001","article-title":"On the use of conventional and statistical-learning techniques for the analysis of PISA results in Spain","volume":"171","author":"Gorostiaga","year":"2016","journal-title":"Neurocomputing"},{"key":"ref_22","unstructured":"Vapnik, V.N. (1998). Statistical Learning Theory, John Wiley & Sons."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Rojo-\u00c1lvarez, J., Mart\u00ednez-Ram\u00f3n, M., Camps-Valls, G., and Mu\u00f1oz-Mar\u00ed, J. (2018). Digital Signal Processing with Kernel Methods, Wiley.","DOI":"10.1002\/9781118705810"},{"key":"ref_24","unstructured":"Fisher, A.R. (1923). The Mathematical Theory of Probabilities, MacMillan."},{"key":"ref_25","unstructured":"Fisher, A.R. (1952). Contributions to Mathematical Statistics, Wiley."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Men, H., Fu, S., Yang, J., Cheng, M., Shi, Y., and Liu, J. (2018). Comparison of SVM, RF and ELM on an Electronic Nose for the Intelligent Evaluation of Paraffin Samples. Sensors, 18.","DOI":"10.3390\/s18010285"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1007\/BF00994018","article-title":"Support-vector networks","volume":"20","author":"Cortes","year":"1995","journal-title":"Mach. Learn."},{"key":"ref_28","first-page":"949","article-title":"A quantitative analysis on the intracardiac electrogram contact during ventricular tachycardia ablation","volume":"43","author":"Rivas","year":"2016","journal-title":"Comput. Cardiol."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/5\/1399\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T15:02:55Z","timestamp":1760194975000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/5\/1399"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,5,2]]},"references-count":28,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2018,5]]}},"alternative-id":["s18051399"],"URL":"https:\/\/doi.org\/10.3390\/s18051399","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2018,5,2]]}}}