{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,4]],"date-time":"2026-03-04T05:13:39Z","timestamp":1772601219336,"version":"3.50.1"},"reference-count":37,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2018,7,6]],"date-time":"2018-07-06T00:00:00Z","timestamp":1530835200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100000266","name":"Engineering and Physical Sciences Research Council","doi-asserted-by":"publisher","award":["EP\/M009106\/1"],"award-info":[{"award-number":["EP\/M009106\/1"]}],"id":[{"id":"10.13039\/501100000266","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Thermal imaging cameras are expensive, particularly those designed for measuring high temperature objects with low measurement uncertainty. A wide range of research and industrial applications would benefit from lower cost temperature imaging sensors with improved metrology. To address this problem, we present the first ever quantification methodology for the temperature measurement performance of an ultra-low cost thermal imaging system based on a smartphone sensor. The camera was formed from a back illuminated silicon Complementary Metal Oxide Semiconductor (CMOS) sensor, developed for the smartphone camera market. It was packaged for use with a Raspberry Pi computer. We designed and fitted a custom-made triplet lens assembly. The system performance was characterised with a range of state-of-the-art techniques and metrics: establishing a temperature resolution of below 10 \u00b0C in the range 600\u20131000 \u00b0C. Furthermore, the scene dependent aspects of combined uncertainty were considered. The minimum angular subtense for which an accurate thermal measurement could be made was determined to be 1.35\u00b0, which corresponds to a 23 mm bar at a distance of 1 m, or 45:1 field-of-view in radiation thermometer nomenclature.<\/jats:p>","DOI":"10.3390\/s18072169","type":"journal-article","created":{"date-parts":[[2018,7,6]],"date-time":"2018-07-06T10:55:44Z","timestamp":1530874544000},"page":"2169","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Thermal Imaging Metrology with a Smartphone Sensor"],"prefix":"10.3390","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4853-1399","authenticated-orcid":false,"given":"Leigh Russell","family":"Stanger","sequence":"first","affiliation":[{"name":"Department of Electronic and Electrical Engineering, The University of Sheffield, Portobello Centre, Pitt Street, Sheffield S14ET, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3448-6067","authenticated-orcid":false,"given":"Thomas Charles","family":"Wilkes","sequence":"additional","affiliation":[{"name":"Department of Geography, The University of Sheffield, Winter Street, Sheffield S10 2TN, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5251-0104","authenticated-orcid":false,"given":"Nicholas Andrew","family":"Boone","sequence":"additional","affiliation":[{"name":"Department of Electronic and Electrical Engineering, The University of Sheffield, Portobello Centre, Pitt Street, Sheffield S14ET, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0234-9981","authenticated-orcid":false,"given":"Andrew John Samuel","family":"McGonigle","sequence":"additional","affiliation":[{"name":"Department of Geography, The University of Sheffield, Winter Street, Sheffield S10 2TN, UK"},{"name":"School of Geosciences, The University of Sydney, Sydney, NSW 2006, Australia"},{"name":"INGV Sezione di Palermo, Via Ugo la Malfa, 153, 90146 Palermo PA, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4242-1204","authenticated-orcid":false,"given":"Jon Raffe","family":"Willmott","sequence":"additional","affiliation":[{"name":"Department of Electronic and Electrical Engineering, The University of Sheffield, Portobello Centre, Pitt Street, Sheffield S14ET, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2018,7,6]]},"reference":[{"key":"ref_1","unstructured":"Blackburn, D.L. (2004, January 11). Temperature measurements of semiconductor devices\u2014A review. Proceedings of the Twentieth Annual IEEE Semiconductor Thermal Measurement and Management Symposium, San Jose, CA, USA."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1615\/AnnualRevHeatTransfer.v11.80","article-title":"Surface Temperature Measurement Using Optical Techniques","volume":"11","author":"Zhang","year":"2000","journal-title":"Ann. Rev. Heat Transf."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"4648","DOI":"10.3390\/s120404648","article-title":"Precise Temperature Mapping of GaN-Based LEDs by Quantitative Infrared Micro-Thermography","volume":"12","author":"Chang","year":"2012","journal-title":"Sensors"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"824","DOI":"10.1109\/19.368060","article-title":"Thermal analysis of integrated-circuit chips using thermographic imaging techniques","volume":"43","author":"Dong","year":"1994","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"5555","DOI":"10.1109\/JSEN.2015.2443563","article-title":"InAs Photodiodes for 3.43 \u00b5m Radiation Thermometry","volume":"15","author":"Zhou","year":"2015","journal-title":"IEEE Sens. J."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"502","DOI":"10.1109\/TIM.2014.2341411","article-title":"InAs\/GaSb Type-II Superlattice for Radiation Thermometry","volume":"64","author":"Hobbs","year":"2015","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1016\/j.infrared.2007.12.001","article-title":"Comparison between multiwavelength infrared and visible pyrometry: Application to metals","volume":"51","author":"Duvaut","year":"2008","journal-title":"Infrared Phys. Technol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1088\/0026-1394\/50\/6\/637","article-title":"Uncertainty of temperature measurements by infrared thermography for metal cutting applications","volume":"50","author":"Lane","year":"2013","journal-title":"Metrologia"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1545","DOI":"10.1007\/s10765-015-1901-8","article-title":"Radiometric Techniques for Emissivity and Temperature Measurements for Industrial Applications","volume":"36","author":"Vuelban","year":"2015","journal-title":"Int. J. Thermophys."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1809","DOI":"10.1109\/TIM.2017.2668598","article-title":"A Novel Principle for Molten Steel Level Measurement in Tundish by Using Temperature Gradient","volume":"66","author":"He","year":"2017","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"133","DOI":"10.3166\/qirt.6.133-147","article-title":"Calibration and validation of thermal imagers","volume":"6","author":"Machin","year":"2009","journal-title":"Quant. Infrared Thermogr. J."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"4700","DOI":"10.3390\/s100504700","article-title":"An Overview of Recent Application of Medical Infrared Thermography in Sports Medicine in Austria","volume":"10","author":"Hildebrandt","year":"2010","journal-title":"Sensors"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Gaussorgues, G. (1994). Optical Image Formation. Infrared Thermography, Chapman & Hall.","DOI":"10.1007\/978-94-011-0711-2"},{"key":"ref_14","unstructured":"Bisbee, T.L., and Pritchard, D.A. (1997, January 15\u201317). Today\u2019s thermal imaging systems: Background and applications for civilian law enforcement and military force protection. Proceedings of the IEEE 31st Annual 1997 International Carnahan Conference on Security Technology, Canbera, Australia."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/S1350-4495(01)00115-3","article-title":"Minimum resolvable temperature difference (MRT): Procedure improvements and dynamic MRT","volume":"43","author":"Krapels","year":"2002","journal-title":"Infrared Phys. Technol."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Minkina, W., and Dudzik, S. (2009). Measurements in Infrared Thermography. Infrared Thermography: Errors and Uncertainties, John Wiley & Sons, Ltd.","DOI":"10.1002\/9780470682234"},{"key":"ref_17","first-page":"195","article-title":"An introduction for machining researchers to measurement uncertainty sources in thermal images of metal cutting","volume":"12","author":"Whitenton","year":"2012","journal-title":"Int. J. Mach. Mach. Mater."},{"key":"ref_18","first-page":"3","article-title":"The International Temperature Scale of 1990 (ITS-90)","volume":"27","year":"1989","journal-title":"Metrologia"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1068\/htrt166","article-title":"Size-of-source effect correction for a thermal imaging radiation thermometer","volume":"31","author":"Saunders","year":"1999","journal-title":"High Temp. High Press."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1007\/s10765-011-0932-z","article-title":"Analysis of Thermal Imagers","volume":"32","year":"2011","journal-title":"Int. J. Thermophys."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Whittam, A., Simpson, R., and McEvoy, H. (2014, January 7\u201311). Performance tests of thermal imaging systems to assess their suitability for quantitative temperature measurements. Proceedings of the 12th International Conference on Qunatitative InfraRed Thermography, Bordeaux, France.","DOI":"10.21611\/qirt.2014.202"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"665","DOI":"10.1364\/AO.43.000665","article-title":"Effects of point-spread function on calibration and radiometric accuracy of CCD camera","volume":"43","author":"Du","year":"2004","journal-title":"Appl. Opt."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Wilkes, T.C., McGonigle, A.J.S., Pering, T.D., Taggart, A.J., White, B.S., Bryant, R.G., and Willmott, J.R. (2016). Ultraviolet Imaging with Low Cost Smartphone Sensors: Development and Application of a Raspberry Pi-Based UV Camera. Sensors, 16.","DOI":"10.3390\/s16101649"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Wilkes, T., Pering, T., McGonigle, A.J.S., Tamburello, G., and Willmott, J. (2017). A Low-Cost Smartphone Sensor-Based UV Camera for Volcanic SO2 Emission Measurements. Remote Sens., 9.","DOI":"10.3390\/rs9010027"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"4323","DOI":"10.1364\/OL.42.004323","article-title":"Low-cost 3D printed 1 nm resolution smartphone sensor-based spectrometer: Instrument design and application in ultraviolet spectroscopy","volume":"42","author":"Wilkes","year":"2017","journal-title":"Opt. Lett."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Wilkes, T., Stanger, L., Willmott, J., Pering, T., McGonigle, A.J.S., and England, R. (2018). The Development of a Low-Cost, Near Infrared, High-Temperature Thermal Imaging System and Its Application to the Retrieval of Accurate Lava Lake Temperatures at Masaya Volcano, Nicaragua. Remote Sens., 10.","DOI":"10.3390\/rs10030450"},{"key":"ref_27","unstructured":"International Standards Organisation (ISO) (2017). TC 135\/SC 8: BS ISO 10880:2017 Non-Destructive Testing-Infrared Thermographic Testing-General Principles, International Standards Organisation (ISO)."},{"key":"ref_28","unstructured":"International Standards Organisation (ISO) (2013). TC 135\/SC 8: BS ISO 10878:2013 Non-destructive testing-Infrared thermography-Vocabulary, International Standards Organisation (ISO)."},{"key":"ref_29","unstructured":"(2008). GUM: Guide to the Expression of Uncertainty in Measurement, Bureau International des Poids et Mesures (BIPM) Joint Committee for Guides in Metrology (JCGM), BIPM."},{"key":"ref_30","unstructured":"(2008). Evaluation of Measurement Data\u2014Supplement 1 to the Guide to the Expression of Uncertainty in Measurement\u2014Propagation of Distributions Using a Monte Carlo Method, Bureau International des Poids et Mesures (BIPM) Joint Committee for Guides in Metrology (JCGM), BIPM."},{"key":"ref_31","first-page":"91","article-title":"Establishing a practical temperature standard by using a narrow-band radiation thermometer with a silicon detector","volume":"32","author":"Sakuma","year":"1983","journal-title":"Bull. NRLM"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"035009:1","DOI":"10.1103\/RevModPhys.88.035009","article-title":"Codata Recommended Values of the Fundamental Physical Constants: 2014","volume":"88","author":"Mohr","year":"2016","journal-title":"Rev. Mod. Phys."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1088\/0026-1394\/40\/4\/309","article-title":"Physical basis of interpolation equations for radiation thermometry","volume":"40","author":"Saunders","year":"2003","journal-title":"Metrologia"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1088\/0026-1394\/53\/1\/61","article-title":"Uncertainty calculation of the effective emissivity of cylinder-conical blackbody cavities","volume":"53","author":"De","year":"2016","journal-title":"Metrologia"},{"key":"ref_35","first-page":"634856:1","article-title":"Figure of Image Quality and Information Capacity in Digital Mammography","volume":"11","author":"Michail","year":"2014","journal-title":"BioMed. Res. Int."},{"key":"ref_36","unstructured":"LumaSense (2018, July 05). Datasheet: MCS640; MCS640_Datasheet-EN-Rev. 09\/22\/2015. Available online: https:\/\/www.lumasenseinc.com\/uploads\/Products\/Temperature_Measurement\/Thermal_Imagers_and_Systems\/MIKRON_Cameras\/MC640_Series\/pdf\/EN-Infrared-Camera-MCS640_Datasheet.pdf."},{"key":"ref_37","unstructured":"Amatek-Land (2018, July 05). Datasheet: CYCLOPS L-A Family of High Precision Non-Contact Pyrometers, MARCOM0346 Cyclops L Rev. 6. Available online: https:\/\/www.ametek-land.com\/\/media\/ameteklandinstruments\/documentation\/products\/portablenoncontactthermometers\/cyclops\/ametek_land_cyclops_brochure_rev6_en.pdf."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/7\/2169\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T15:11:31Z","timestamp":1760195491000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/7\/2169"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,7,6]]},"references-count":37,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2018,7]]}},"alternative-id":["s18072169"],"URL":"https:\/\/doi.org\/10.3390\/s18072169","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,7,6]]}}}