{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T04:50:20Z","timestamp":1778820620758,"version":"3.51.4"},"reference-count":43,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2018,7,11]],"date-time":"2018-07-11T00:00:00Z","timestamp":1531267200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"the National Nature Science Foundation of China under Grant.","award":["61671417 and 61431017"],"award-info":[{"award-number":["61671417 and 61431017"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A novel framework based on the fast orthogonal search (FOS) method coupled with factorization algorithms was proposed and implemented to realize high-accuracy muscle force estimation via surface electromyogram (SEMG). During static isometric elbow flexion, high-density SEMG (HD-SEMG) signals were recorded from upper arm muscles, and the generated elbow force was measured at the wrist. HD-SEMG signals were decomposed into time-invariant activation patterns and time-varying activation curves using three typical factorization algorithms including principal component analysis (PCA), independent component analysis (ICA), and nonnegative matrix factorization (NMF). The activation signal of the target muscle was obtained by summing the activation curves, and the FOS algorithm was used to create basis functions with activation signals and establish the force estimation model. Static isometric elbow flexion experiments at three target levels were performed on seven male subjects, and the force estimation performances were compared among three typical factorization algorithms as well as a conventional method for extracting the average signal envelope of all HD-SEMG channels (AVG-ENVLP method). The overall root mean square difference (RMSD) values between the measured forces and the estimated forces obtained by different methods were 11.79 \u00b1 4.29% for AVG-ENVLP, 9.74 \u00b1 3.77% for PCA, 9.59 \u00b1 3.81% for ICA, and 9.51 \u00b1 4.82% for NMF. The results demonstrated that, compared to the conventional AVG-ENVLP method, factorization algorithms could substantially improve the performance of force estimation. The FOS method coupled with factorization algorithms provides an effective way to estimate the combined force of multiple muscles and has potential value in the fields of sports biomechanics, gait analysis, prosthesis control strategy, and exoskeleton devices for assisted rehabilitation.<\/jats:p>","DOI":"10.3390\/s18072238","type":"journal-article","created":{"date-parts":[[2018,7,11]],"date-time":"2018-07-11T10:50:09Z","timestamp":1531306209000},"page":"2238","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["A SEMG-Force Estimation Framework Based on a Fast Orthogonal Search Method Coupled with Factorization Algorithms"],"prefix":"10.3390","volume":"18","author":[{"given":"Xiang","family":"Chen","sequence":"first","affiliation":[{"name":"Department of Electronic Science and Technology, University of Science and Technology of China, Hefei 230027, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuan","family":"Yuan","sequence":"additional","affiliation":[{"name":"Department of Electronic Science and Technology, University of Science and Technology of China, Hefei 230027, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shuai","family":"Cao","sequence":"additional","affiliation":[{"name":"Department of Electronic Science and Technology, University of Science and Technology of China, Hefei 230027, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1533-4340","authenticated-orcid":false,"given":"Xu","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Electronic Science and Technology, University of Science and Technology of China, Hefei 230027, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xun","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Electronic Science and Technology, University of Science and Technology of China, Hefei 230027, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2018,7,11]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"753","DOI":"10.1016\/j.humov.2013.03.003","article-title":"How much does the human medial gastrocnemius muscle contribute to ankle torques outside the sagittal plane?","volume":"32","author":"Vieira","year":"2013","journal-title":"Hum. Mov. Sci."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1007\/s10237-011-0290-6","article-title":"A musculoskeletal model for the lumbar spine","volume":"11","author":"Christophy","year":"2012","journal-title":"Biomech. Model. Mechanobiol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.bspc.2016.11.010","article-title":"Co-contraction activity of ankle muscles during walking: A gender comparison","volume":"33","author":"Mengarelli","year":"2017","journal-title":"Biomed. Signal Process. Control"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1109\/TBME.2011.2170687","article-title":"An algorithm for the estimation of the signal-to-noise ratio in surface myoelectric signals generated during cyclic movements","volume":"59","author":"Agostini","year":"2012","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1016\/j.gaitpost.2006.10.012","article-title":"Electromyographic patterns in children with cerebral palsy: Do they change after surgery?","volume":"26","author":"Patikas","year":"2007","journal-title":"Gait Posture"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1007\/s00422-008-0278-1","article-title":"Surface EMG in advanced hand prosthetics","volume":"100","author":"Castellini","year":"2009","journal-title":"Biol. Cybern."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1016\/j.jelekin.2011.12.012","article-title":"High density electromyography data of normally limbed and transradial amputee subjects for multifunction prosthetic control","volume":"22","author":"Daley","year":"2012","journal-title":"J. Electromyogr. Kinesiol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1109\/JBHI.2013.2286455","article-title":"sEMG-based joint force control for an upper-limb power-assist exoskeleton robot","volume":"18","author":"Li","year":"2014","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Siu, H.C., Arenas, A.M., Sun, T., and Stirling, L.A. (2018). Implementation of a Surface Electromyography-Based Upper Extremity Exoskeleton Controller Using Learning from Demonstration. Sensors, 18.","DOI":"10.3390\/s18020467"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1016\/0021-9290(91)90347-P","article-title":"A comparison of the triceps surae and residual muscle moments at the ankle during cycling","volume":"24","author":"Gregor","year":"1991","journal-title":"J. Biomech."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1890","DOI":"10.1080\/10255842.2015.1070578","article-title":"On the benefits of using HD-sEMG technique for estimating muscle force","volume":"18","author":"Boudaoud","year":"2015","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"ref_12","unstructured":"Mobasser, F., and Hashtrudi-Zaad, K. (2005, January 28\u201331). Rowing stroke force estimation with EMG signals using artificial neural networks. Proceedings of the 2005 IEEE Conference on CCA, Toronto, ON, Canada."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1186\/1475-925X-12-86","article-title":"Voluntary EMG-to-force estimation with a multi-scale physiological muscle model","volume":"12","author":"Hayashibe","year":"2013","journal-title":"Biomed. Eng. Online"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Wang, K., Zhang, X., Ota, J., and Huang, Y. (2018). Estimation of Handgrip Force from SEMG Based on Wavelet Scale Selection. Sensors, 18.","DOI":"10.3390\/s18020663"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1024","DOI":"10.1109\/10.634654","article-title":"Relating agonist-antagonist electromyograms to joint torque during isometric, quasi-isotonic, nonfatiguing contractions","volume":"44","author":"Clancy","year":"1997","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"2690","DOI":"10.1016\/j.jbiomech.2005.08.007","article-title":"Influence of advanced electromyogram (EMG) amplitude processors on EMG-to-torque estimation during constant-posture, force-varying contractions","volume":"39","author":"Clancy","year":"2006","journal-title":"J. Biomech."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1177\/036354659502300421","article-title":"An explanation for various rectus femoris strain injuries using previously undescribed muscle architecture","volume":"23","author":"Hasselman","year":"1995","journal-title":"Am. J. Sports Med."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"W182","DOI":"10.2214\/AJR.07.2947","article-title":"Normal anatomy and strains of the deep musculotendinous junction of the proximal rectus femoris: MRI features","volume":"190","author":"Gyftopoulos","year":"2008","journal-title":"Am. J. Roentgenol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1159\/000147199","article-title":"Anatomical partitioning of three multiarticular human muscles","volume":"142","author":"Segal","year":"1991","journal-title":"Cells Tissues Organs"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1159\/000147942","article-title":"Morphological analysis of the human tibialis anterior and medial gastrocnemius muscles","volume":"158","author":"Wolf","year":"1997","journal-title":"Cells Tissues Organs"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1041","DOI":"10.1109\/TNSRE.2016.2515087","article-title":"Force modelling of upper limb biomechanics using ensemble fast orthogonal search on high-density electromyography","volume":"24","author":"Johns","year":"2016","journal-title":"IEEE Trans. Neural Syst. Rehab. Eng."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Johns, G., Morin, E., and Hashtrudi-Zaad, K. (2015, January 7\u201312). Upper-Limb Force Modeling using Rotated Ensembles with Fast Orthogonal Search on High-Density Electromyography. Proceedings of the World Congress on Medical Physics and Biomedical Engineering, Toronto, ON, Canada.","DOI":"10.1007\/978-3-319-19387-8_232"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jelekin.2004.06.008","article-title":"Towards optimal multi-channel EMG electrode configurations in muscle force estimation: A high density EMG study","volume":"15","author":"Staudenmann","year":"2005","journal-title":"J. Electromyogr. Kinesiol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"046005","DOI":"10.1088\/1741-2552\/aa63ba","article-title":"An isometric muscle force estimation framework based on a high-density surface EMG array and an NMF algorithm","volume":"14","author":"Huang","year":"2017","journal-title":"J. Neural Eng."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1109\/TBME.2006.870246","article-title":"Improving EMG-based muscle force estimation by using a high-density EMG grid and principal component analysis","volume":"53","author":"Staudenmann","year":"2006","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1109\/TBME.2006.889202","article-title":"Independent component analysis of high-density electromyography in muscle force estimation","volume":"54","author":"Staudenmann","year":"2007","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1016\/j.jelekin.2011.10.012","article-title":"EMG\u2013force modeling using parallel cascade identification","volume":"22","author":"Hashemi","year":"2012","journal-title":"J. Electromyogr. Kinesiol."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1109\/TNSRE.2013.2282898","article-title":"Extracting signals robust to electrode number and shift for online simultaneous and proportional myoelectric control by factorization algorithms","volume":"22","author":"Muceli","year":"2014","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Gazzoni, M., Celadon, N., Mastrapasqua, D., Paleari, M., Margaria, V., and Ariano, P. (2014). Quantifying forearm muscle activity during wrist and finger movements by means of multi-channel electromyography. PLoS ONE, 9.","DOI":"10.1371\/journal.pone.0109943"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"066001","DOI":"10.1088\/1741-2560\/13\/6\/066001","article-title":"Muscle-tendon units localization and activation level analysis based on high-density surface EMG array and NMF algorithm","volume":"13","author":"Huang","year":"2016","journal-title":"J. Neural Eng."},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Bai, F., Chew, C.M., Li, J., Shen, B., and Lubecki, T.M. (2013, January 24\u201326). Muscle force estimation method with surface EMG for a lower extremities rehabilitation device. Proceedings of the 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR), Seattle, WA, USA.","DOI":"10.1109\/ICORR.2013.6650419"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1109\/TBME.2006.889190","article-title":"Estimation of elbow-induced wrist force with EMG signals using fast orthogonal search","volume":"54","author":"Mobasser","year":"2007","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_33","unstructured":"Nordin, M., and Frankel, V.H. (2001). Basic Biomechanics of the Musculoskeletal System, Lippincott Williams & Wilkins."},{"key":"ref_34","unstructured":"Johnson, D.E. (1998). Applied Multivariate Methods for Data Analysts, Duxbury Resource Center."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1016\/j.jelekin.2004.01.004","article-title":"The application of independent component analysis to the multi-channel surface electromyographic signals for separation of motor unit action potential trains: Part I\u2014Measuring techniques","volume":"14","author":"Nakamura","year":"2004","journal-title":"J. Electromyogr. Kinesiol."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"626","DOI":"10.1109\/72.761722","article-title":"Fast and robust fixed-point algorithms for independent component analysis","volume":"10","author":"Hyvarinen","year":"1999","journal-title":"IEEE Trans. Neural Netw."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"788","DOI":"10.1038\/44565","article-title":"Learning the parts of objects by non-negative matrix factorization","volume":"401","author":"Lee","year":"1999","journal-title":"Nature"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"2199","DOI":"10.1152\/jn.00222.2005","article-title":"Matrix factorization algorithms for the identification of muscle synergies: Evaluation on simulated and experimental data sets","volume":"95","author":"Tresch","year":"2006","journal-title":"J. Neurophysiol."},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"Evans, N. (2015). Bodybuilding Anatomy, 2E, Human Kinetics.","DOI":"10.5040\/9781718225022"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1007\/BF00204124","article-title":"A robust orthogonal algorithm for system identification and time-series analysis","volume":"60","author":"Korenberg","year":"1989","journal-title":"Biol. Cybern."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"790","DOI":"10.1109\/TBME.2009.2036444","article-title":"Use of the fast orthogonal search method to estimate optimal joint angle for upper limb Hill-muscle models","volume":"57","author":"Mountjoy","year":"2010","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1016\/j.clinbiomech.2008.08.003","article-title":"Surface electromyography and muscle force: Limits in sEMG\u2013force relationship and new approaches for applications","volume":"24","author":"Rau","year":"2009","journal-title":"Clin. Biomech."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1109\/TCYB.2014.2386856","article-title":"A study on estimation of joint force through isometric index finger abduction with the help of SEMG peaks for biomedical applications","volume":"46","author":"Na","year":"2016","journal-title":"IEEE Trans. Cybern."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/7\/2238\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T15:11:41Z","timestamp":1760195501000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/7\/2238"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,7,11]]},"references-count":43,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2018,7]]}},"alternative-id":["s18072238"],"URL":"https:\/\/doi.org\/10.3390\/s18072238","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,7,11]]}}}