{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T12:31:39Z","timestamp":1780403499563,"version":"3.54.1"},"reference-count":85,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2018,7,16]],"date-time":"2018-07-16T00:00:00Z","timestamp":1531699200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100005632","name":"Narodowe Centrum Bada\u0144 i Rozwoju","doi-asserted-by":"publisher","award":["LIDER \/252\/L-6\/NCBR\/2015"],"award-info":[{"award-number":["LIDER \/252\/L-6\/NCBR\/2015"]}],"id":[{"id":"10.13039\/501100005632","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Measurement of blood-borne volatile organic compounds (VOCs) occurring in human exhaled breath as a result of metabolic changes or pathological disorders is a promising tool for noninvasive medical diagnosis, such as exhaled acetone measurements in terms of diabetes monitoring. The conventional methods for exhaled breath analysis are based on spectrometry techniques, however, the development of gas sensors has made them more and more attractive from a medical point of view. This review focuses on the latest achievements in gas sensors for exhaled acetone detection. Several different methods and techniques are presented and discussed as well.<\/jats:p>","DOI":"10.3390\/s18072298","type":"journal-article","created":{"date-parts":[[2018,7,16]],"date-time":"2018-07-16T11:38:50Z","timestamp":1531741130000},"page":"2298","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":155,"title":["Sensors for Enhanced Detection of Acetone as a Potential Tool for Noninvasive Diabetes Monitoring"],"prefix":"10.3390","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9148-1094","authenticated-orcid":false,"given":"Artur","family":"Rydosz","sequence":"first","affiliation":[{"name":"Department of Electronics, AGH University of Science and Technology, 30-059 Krakow, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2018,7,16]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1038\/scientificamerican0792-74","article-title":"Breath test in medicine","volume":"267","author":"Phillips","year":"1992","journal-title":"Sci. Am."},{"key":"ref_2","first-page":"128","article-title":"Acetone in breath and blood","volume":"88","author":"Crofford","year":"1977","journal-title":"Trans. Am. Clin. Climatol. Assoc."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"2374","DOI":"10.1073\/pnas.68.10.2374","article-title":"Quantitative analysis of urine vapor and breath by gas-liquid partition chromatography","volume":"68","author":"Pauling","year":"1971","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/S1570-0232(04)00657-9","article-title":"Determination of acetone in human breath by gas chromatography-mass spectrometry and solid-phase microextraction with on-fiber derivatization","volume":"810","author":"Deng","year":"2004","journal-title":"J. Chromatogr. B"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1016\/j.jpba.2017.07.013","article-title":"GC-MS based metabolomics used for the identification of cancer volatile organic compunds as biomarkers","volume":"147","author":"Lubes","year":"2018","journal-title":"J. Pharm. Biomed. Anal."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.ijms.2010.06.011","article-title":"Multidimensional statistical analysis of PTR-MS breath samples: A test study on irradiation detection","volume":"295","author":"Fedrigo","year":"2010","journal-title":"Int. J. Mass Spectrom."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"037110","DOI":"10.1088\/1752-7155\/7\/3\/037110","article-title":"Correlations between blood glucose and breath components from portable gas sensors and PTR-TOF-MS","volume":"7","author":"Righettoni","year":"2013","journal-title":"J. Breath Res."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1002\/mas.21349","article-title":"Ion mobility spectrometry-massspectrometry (IMS-MS) of small molecules: Separating and assigning structures to ions","volume":"32","author":"Lapthorn","year":"2013","journal-title":"Mass Spectrom. Rev."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"170175","DOI":"10.1016\/j.jpba.2016.01.054","article-title":"Increasing conclusiveness of clinical breth analysis by improved baseline correction of multi capillary column\u2014ion mobility spectrometry (MCC-IMS) data","volume":"127","author":"Szymanska","year":"2016","journal-title":"J. Pharm. Biomed. Anal."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1016\/j.ijms.2015.12.007","article-title":"SIFT-MS quantification of several breath biomarkers of inlammatory bowel disease, IBD; A detailed study of the ion chemistry","volume":"396","author":"Michalcikova","year":"2016","journal-title":"Int. J. Mass Spectrom."},{"key":"ref_11","first-page":"945","article-title":"Direct, rapid quantitative analyses of BVOCs using SIFT-MS and PTR-MS obviating sample collection","volume":"30","author":"Smith","year":"2011","journal-title":"TrAC"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1016\/j.snb.2017.10.178","article-title":"Exhaled breath analysis using electronic nose and gas chromatography-mass spectrometry for non-invasive diagnosis of chronic kidney disease, diabetes mellitus and healthy subjects","volume":"257","author":"Saidi","year":"2018","journal-title":"Sens. Actuators B"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1016\/j.jtho.2018.01.024","article-title":"Training and Validating a Portable Electronic Nose for Lung Caner Screening","volume":"13","author":"Dingemans","year":"2018","journal-title":"J. Thorac. Oncol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1016\/j.cca.2016.05.013","article-title":"VOC breath biomarkers in lung cancer","volume":"459","author":"Saalberg","year":"2016","journal-title":"Clin. Chim. Acta"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"800","DOI":"10.1016\/j.snb.2017.08.057","article-title":"Analysis of volatile organic compounds in exhaled human breath for lung cancer diagnosis uisng a sensor system","volume":"255","author":"Chang","year":"2018","journal-title":"Sens. Actuators B"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"970","DOI":"10.1016\/j.jaci.2016.08.004","article-title":"Breathomics in the setting of asthma and chronic obstructive pulmonary disease","volume":"138","author":"Bos","year":"2016","journal-title":"J. Allergy Clin. Immunol."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1016\/j.anai.2018.01.031","article-title":"Measurement of fractional exhaled nitric oxide in real-world clinical practice alters asthma treatment decisions","volume":"120","author":"Hanania","year":"2018","journal-title":"Ann. Allergy Asthma Immunol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"034002","DOI":"10.1088\/1752-7155\/10\/3\/034002","article-title":"A systematic review of breath analysis and detection of volatile organic compounds in COPD","volume":"10","author":"Anders","year":"2016","journal-title":"J. Breath Res."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.clinms.2018.02.003","article-title":"Real-time mass spectrometric identification of metabolites characteristic of chronic obstructive pulmonary disease in exhaled breath","volume":"7","author":"Bregy","year":"2018","journal-title":"Clin. Mass Spectrom."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/j.compbiomed.2018.04.002","article-title":"Early non-invasive detection of breast cancer using exhaled breath and urine analysis","volume":"96","author":"Boger","year":"2018","journal-title":"Comput. Biol. Med."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/j.critrevonc.2012.11.007","article-title":"Diagnosis of breast cancer based on breath analysis: An emerging method","volume":"87","author":"LI","year":"2013","journal-title":"Crit. Rev. Oncol. Hematol."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1016\/j.diabres.2012.02.006","article-title":"The clinical potential of exhaled breath analysis for diabetes mellitus","volume":"97","author":"Minh","year":"2012","journal-title":"Diabetes Res. Clin. Pract."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/j.elecom.2017.09.005","article-title":"Non-invasive monitoring of diabetes through analysis of the exhaled breath condensate (aerosol)","volume":"83","author":"Karyakin","year":"2017","journal-title":"Electrochem. Commun."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"3581","DOI":"10.1021\/ac902695n","article-title":"Si: WO3 Sensors for highly selective detection of acetone for easy diagnosis of diabetes by breath analysis","volume":"82","author":"Righettoni","year":"2010","journal-title":"Anal. Chem."},{"key":"ref_25","unstructured":"WHO (World Health Organization) (2018, June 12). Global Report on Diabetes. Available online: http:\/\/www.who.int\/diabetes\/en\/."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"881","DOI":"10.1177\/1932296815572366","article-title":"A negative correlation between blood glucose and acetone measured in healthy and type-1 diabetes mellitus patient breath","volume":"9","author":"Rydosz","year":"2015","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_27","unstructured":"Amann, A., and Smith, D. (2013). Volatile Biomarkers. Non-Invasive Diagnosis in Physiology and Medicine, Elsevier."},{"key":"ref_28","unstructured":"FIGARO (2018, June 12). TGS 822\u2013Product Information. Available online: www.figarosensor.com\/products\/822pdf.pdf."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Lee, J., and Lim, S.-H. (2018). CNT Foam-Embedded Micro Gas Preconcentrator for Low-Concentration Ethane Measurements. Sensors, 18.","DOI":"10.3390\/s18051547"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1016\/j.buildenv.2017.06.038","article-title":"Human breath as a source of VOCs in the built environment, Part I: A method for sampling and detection species","volume":"125","author":"Sun","year":"2017","journal-title":"Build. Environ."},{"key":"ref_31","unstructured":"Eranna, G. (2011). Metal Oxide Nanostructures as Gas Sensing Devices, CRC Press."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1016\/j.sna.2017.10.021","article-title":"Room-temperature gas sensing of ZnO-based gas sensor: A review","volume":"267","author":"Zhu","year":"2017","journal-title":"Sens. Actuators A Phys."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1016\/j.snb.2018.05.097","article-title":"Room-temperature synthesis of CuO\/reduced graphene oxie nanohybrids for hgih-performance NO2 gas sensor","volume":"271","author":"Li","year":"2018","journal-title":"Sens. Actuators B"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"1119","DOI":"10.1016\/j.snb.2017.07.152","article-title":"Room temperature vanadium dioxide-carbon nanotube gas sensos via continuous hydrothermal flow synthesis","volume":"255","author":"Evans","year":"2018","journal-title":"Sens. Actuators B"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1016\/j.snb.2017.10.036","article-title":"Ambiet temperature selective ammonia gas sensor based on SnO2-APTES modificiations","volume":"256","author":"Hijazi","year":"2018","journal-title":"Sens. Actuators B"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"876","DOI":"10.1016\/j.snb.2016.06.168","article-title":"Microwave-based sensors with phthalocyanine films for acetone, ethanol and methanol detection","volume":"237","author":"Rydosz","year":"2016","journal-title":"Sens. Actuators B"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"882","DOI":"10.1016\/j.snb.2017.01.194","article-title":"Six-port microwave system for volatile organic compounds detection","volume":"245","author":"Staszek","year":"2017","journal-title":"Sens. Actuators B"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1016\/j.snb.2018.05.114","article-title":"A compact breath acetone analyzer based on an ultraviolot light emitting diode","volume":"273","author":"Li","year":"2018","journal-title":"Sens. Actuators B Chem."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"819","DOI":"10.1016\/j.jcis.2017.10.114","article-title":"Ionic liquid-based slab optical waveguide sensor for the detection of ammonia in human breath","volume":"512","author":"Gao","year":"2018","journal-title":"J. Colloid Interface Sci."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.microc.2018.01.014","article-title":"Laser-based spectrometer for opitcal trace gas detection in young adults with autism","volume":"138","author":"Bratu","year":"2018","journal-title":"Microchem. J."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"1004","DOI":"10.1109\/JSEN.2015.2496212","article-title":"Performance of Si-doped WO3 thin films for acetone sensing prepared by glacing angle DC magnetron sputtering","volume":"16","author":"Rydosz","year":"2016","journal-title":"IEEE Sens. J."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1016\/j.materresbull.2018.02.006","article-title":"Synthesis and gas sensing properties of NiO\/SnO2 herarchical structures toward ppb-level acetone detection","volume":"102","author":"Hu","year":"2018","journal-title":"Mater. Res. Bull."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1016\/j.snb.2017.06.176","article-title":"One-step synthesis of 2D C3N4-tin oxide gas sensors for enhanced acetone vapor detection","volume":"253","author":"Hu","year":"2017","journal-title":"Sens. Actuators B"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1016\/j.apsusc.2017.12.090","article-title":"An investigation of GO-SnO2-TiO2 ternary nanocomposite for the detection of acetone in diabetes mellitus patient\u2019s breath","volume":"449","author":"Kalidoss","year":"2018","journal-title":"Appl. Surf. Sci."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1016\/j.snb.2017.06.179","article-title":"Rapid acetone detection using indium loaded WO3\/SnO2 nanohybrid sensor","volume":"253","author":"Tomer","year":"2017","journal-title":"Sens. Actuators B"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/j.mssp.2017.06.002","article-title":"SnO2 decorated SiO2 chemical sensors: Enhanced sensing performance toward ethanol and acetone","volume":"68","author":"Asgari","year":"2018","journal-title":"Mater. Sci. Semicond. Proccess."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/j.snb.2018.03.037","article-title":"Modified impregnation synthesis of Ru-loaded WO3 nanoparticles for acetone sensing","volume":"265","author":"Li","year":"2018","journal-title":"Sens. Actuators B"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"616","DOI":"10.1016\/j.snb.2017.12.051","article-title":"Hierarchically interconnected porosity control of catalyst-loaded WO3 nanofiber scaffold: Superior acetone sensing layers for exhaled breath analysis","volume":"259","author":"Kim","year":"2018","journal-title":"Sens. Actuators B"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"1482","DOI":"10.1016\/j.snb.2017.08.158","article-title":"Fully gravure-printed WO3\/Pt-decorated rGO nanosheets composite film for detection of acetone","volume":"255","author":"Chen","year":"2018","journal-title":"Sens. Actuators B"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.snb.2017.10.073","article-title":"Iron and carbon codoped WO3 with hierarchical walnut-like microstructure for highly sensitive and selective acetone sensor","volume":"256","author":"Shen","year":"2018","journal-title":"Sens. Actuators B"},{"key":"ref_51","doi-asserted-by":"crossref","unstructured":"Bartsch, H., Stoepel, D., Mueller, J., and Rydosz, A. (2017, January 10\u201313). Printed heater elements for smart sensor packages in LTCC. Proceedings of the 2017 21st European Microelectronics and Packaging Conference (EMPC) & Exhibition, Warsaw, Poland.","DOI":"10.23919\/EMPC.2017.8346841"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1016\/j.cej.2018.01.072","article-title":"Prussian Blue analogue derived prorous NiFe2O4 nanocubes for low-concentration acetone sensing at low working temperature","volume":"338","author":"Wang","year":"2018","journal-title":"Chem. Eng. J."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1016\/j.jallcom.2016.11.298","article-title":"Acetone gas detection using TiO2 nanoparticles functionalized In2O3 nanowires for diagnosis of diabetes","volume":"696","author":"Park","year":"2017","journal-title":"J. Alloy Compd."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1016\/j.snb.2018.05.046","article-title":"Facile preparation of hierarchical Sb-doped In2O3 microstructures for acetone detection","volume":"270","author":"Liu","year":"2018","journal-title":"Sens. Actuators B"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"S557","DOI":"10.1016\/j.ceramint.2017.05.296","article-title":"Acetone gas sensors based on ZnO nanostructures dectorated with Pt and Nb","volume":"43","author":"Wongrat","year":"2017","journal-title":"Ceram. Int."},{"key":"ref_56","doi-asserted-by":"crossref","unstructured":"Kollbek, K., Szkudlarek, A., Klejna, S., and Rydosz, A. (2018). Electronic sensitization of CuO thin films by Cr-doping for enhanced gas sensor response at low detection limit. J. Mater. Chem. C, under review.","DOI":"10.1088\/2053-1591\/aae0d8"},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"704","DOI":"10.1016\/S1002-0721(16)60082-0","article-title":"Sensing performances to low concentration acetone for palladium doped LaFeO3 sensors","volume":"34","author":"Wang","year":"2016","journal-title":"J. Rare Earths"},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1016\/j.snb.2018.05.028","article-title":"Bimetallic Pt-Au nanocatalysts decorated In2O3 nests composed of ultrathin nanosheets for type 1 diabetes diagnosis","volume":"270","author":"Ma","year":"2018","journal-title":"Sens. Actuators B"},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"436","DOI":"10.1016\/j.snb.2017.11.131","article-title":"Hollow CuFe2O4\/\u03b1-Fe2O3 composite with ultrathin porous shell for acetone detection at ppb levels","volume":"258","author":"Li","year":"2018","journal-title":"Sens. Actuators B"},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1016\/j.snb.2017.05.167","article-title":"Three-dimensional ordered ZnO-Fe2O4 inverse opal gas sensors toward trace concentration acetone detection","volume":"252","author":"Zjang","year":"2017","journal-title":"Sens. Actuators B"},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/j.apsusc.2018.02.189","article-title":"Multi-shelled ZnCO2O4 yolk-shell spheres for high-performance acetone gas sensor","volume":"443","author":"ZXiong","year":"2018","journal-title":"Appl. Surf. Sci."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"1052","DOI":"10.1016\/j.snb.2016.07.154","article-title":"Controllable synthesis of Co3O4 crossed nanosheet arrays toward an acetone gas sensor","volume":"238","author":"Zhang","year":"2017","journal-title":"Sens. Actuators B"},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"1173","DOI":"10.1016\/j.snb.2017.06.002","article-title":"Mixed potential type sensor based on stabilized zirconia and Co1\u2212xZnxFe2O4 sensing electrode for detection of acetone","volume":"255","author":"Hao","year":"2018","journal-title":"Sens. Actuators B"},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1016\/j.snb.2016.07.094","article-title":"Acetone sensing performances based on nanoporous TiO2 synthesized by a facile hydrothermal method","volume":"238","author":"Chen","year":"2017","journal-title":"Sens. Actuators B"},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/j.vacuum.2016.08.006","article-title":"Ultraviolet illumination effect on monolayer graphene-based resistive sensor for acetone detection","volume":"140","author":"Yang","year":"2017","journal-title":"Vacuum"},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/j.snb.2017.06.116","article-title":"Enhanced acetone sensing properties of monolayer graphene at room temperatue by electrode spacing effect and UV illumination","volume":"253","author":"Yang","year":"2017","journal-title":"Sens. Actuators B"},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.snb.2017.12.114","article-title":"Low concentration acetone gas sensing properties of 3 wt % Pd-doped SmCoxFe1\u2212xO3 nanocrystalline powders under UV light ilumination","volume":"260","author":"Zhang","year":"2018","journal-title":"Sens. Actuators B"},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.bios.2015.04.023","article-title":"An acetone bio-sniffer (gas phase biosensor) enabling assessment of lipid metabolism from exhaled breath","volume":"73","author":"Ye","year":"2015","journal-title":"Biosens. Bioelectron."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/j.aca.2004.12.018","article-title":"Determination of acetone in breath","volume":"535","author":"Teshima","year":"2005","journal-title":"Anal. Chim. Acta"},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1016\/j.snb.2005.10.050","article-title":"Two-step preconcentration for analysis of exhaled gas of human breath with electronic nose","volume":"117","author":"Cho","year":"2006","journal-title":"Sens. Actuators B"},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"2551","DOI":"10.1016\/j.jchromb.2009.06.039","article-title":"Breath acetone analysis with miniaturized sample preparation device: In-needle preconcentration and subsequent determination by gas chromatography-mass spectrometry","volume":"877","author":"Ueta","year":"2009","journal-title":"J. Chromatogr. B"},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/S0003-2670(98)00294-3","article-title":"Analyzing organic vapors in exhaled breath using a surface acoustic wave sensor array with preconcentration: Selection and characterization of the preconentrator adsorbent","volume":"371","author":"Groves","year":"1998","journal-title":"Anal. Chim. Act."},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1016\/j.snb.2012.07.034","article-title":"A microfabricated preconcentration device for breath analysis","volume":"180","author":"Li","year":"2013","journal-title":"Sens. Actuators B"},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"2640","DOI":"10.1016\/j.microrel.2012.05.012","article-title":"A gas micropreconcentrator for low level acetone measurements","volume":"52","author":"Rydosz","year":"2012","journal-title":"Microelectron. Reliab."},{"key":"ref_75","first-page":"126","article-title":"Micropreconcentrators in silicon-glass technology for the detection of diabetes biomarkers","volume":"44","author":"Rydosz","year":"2014","journal-title":"J. Microelectr. Electr. Compon. Mater."},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"1889","DOI":"10.1109\/JSEN.2013.2245888","article-title":"Amicropreconcentrator design using low temperature cofired ceramics technology for acetone detection applications","volume":"13","author":"Rydosz","year":"2013","journal-title":"IEEE Sens. J."},{"key":"ref_77","doi-asserted-by":"crossref","unstructured":"Rydosz, A., Wincza, K., and Gruszczynski, S. (2016, January 19\u201321). Microsystem in LTCC for the Detection of Acetone in Healthy and Diabetes Breath. Proceedings of the 2016 IEEE ANDESCON Conference, Arequipa, Peru.","DOI":"10.1109\/ANDESCON.2016.7836200"},{"key":"ref_78","doi-asserted-by":"crossref","first-page":"921","DOI":"10.3390\/metabo4040921","article-title":"Micropreconcentrator in LTCC technology with mass spectrometry for the detection of acetone in healthy and type-1 diabetes mellitus patient breath","volume":"4","author":"Rydosz","year":"2014","journal-title":"Metabolities"},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1016\/j.snb.2017.12.168","article-title":"Room-temperature-operated organic-based acetone gas sensor forbreath analysis","volume":"260","author":"Chuang","year":"2018","journal-title":"Sens. Actuators B"},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"8230","DOI":"10.3390\/s91008230","article-title":"Breath analysis using laser spectroscopic techniques: Breath biomarkers, spectral fingerprints, and detection limits","volume":"9","author":"Wang","year":"2009","journal-title":"Sensors"},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"2079","DOI":"10.1007\/s00216-011-5173-2","article-title":"Phase-resolved real-time breath analysis during exercise by means of smart processing of PTR-MS data","volume":"401","author":"Schwoebel","year":"2011","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_82","unstructured":"(2018, July 16). Toshiba Develops Breath Analyzer for Medical Applications. Available online: https:\/\/www.toshiba.co.jp\/about\/press\/2014_03\/pr1801.htm."},{"key":"ref_83","doi-asserted-by":"crossref","first-page":"S10","DOI":"10.1016\/j.cardfail.2013.06.029","article-title":"Reduction in Exhaled Acetone Tracks with Weight Loss Following Diuretic Therapy in Acute Decompensated Heart Failure","volume":"19","author":"Tranchito","year":"2013","journal-title":"J. Card Fail."},{"key":"ref_84","first-page":"112","article-title":"A case of acute decompensated heart failure evaluated by series of exhaled acetone concentrations as noninvasive biomarker of heart failure severity","volume":"204","author":"Yokokawa","year":"2016","journal-title":"Int. J. Cardiovasc."},{"key":"ref_85","doi-asserted-by":"crossref","unstructured":"Saasa, V., Malwela, T., Beukes, M., Mokgotho, M., Liu, C.-P., and Mwakikunga, B. (2018). Sensing Technologies for Detection of Acetone in Human Breath for Diabetes Diagnosis and Monitoring. Diagnostics, 8.","DOI":"10.3390\/diagnostics8010012"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/7\/2298\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T15:12:22Z","timestamp":1760195542000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/7\/2298"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,7,16]]},"references-count":85,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2018,7]]}},"alternative-id":["s18072298"],"URL":"https:\/\/doi.org\/10.3390\/s18072298","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,7,16]]}}}