{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,16]],"date-time":"2026-05-16T19:54:48Z","timestamp":1778961288412,"version":"3.51.4"},"reference-count":49,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2018,10,31]],"date-time":"2018-10-31T00:00:00Z","timestamp":1540944000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Diabetes is one of the most rapidly-growing chronic diseases in the world. Acetone, a volatile organic compound in exhaled breath, shows a positive correlation with blood glucose and has proven to be a biomarker for type-1 diabetes. Measuring the level of acetone in exhaled breath can provide a non-invasive, low risk of infection, low cost, and convenient way to monitor the health condition of diabetics. There has been continuous demand for the improvement of this non-invasive, sensitive sensor system to provide a fast and real-time electronic readout of blood glucose levels. A novel nanostructured K2W7O22 has been recently used to test acetone with concentration from 0 parts-per-million (ppm) to 50 ppm at room temperature. The results revealed that a K2W7O22 sensor shows a sensitive response to acetone, but the detection limit is not ideal due to the limitations of the detection system of the device. In this paper, we report a K2W7O22 sensor with an improved sensitivity and detection limit by using an optimized circuit to minimize the electronic noise and increase the signal to noise ratio for the purpose of weak signal detection while the concentration of acetone is very low.<\/jats:p>","DOI":"10.3390\/s18113703","type":"journal-article","created":{"date-parts":[[2018,10,31]],"date-time":"2018-10-31T11:55:41Z","timestamp":1540986941000},"page":"3703","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Highly Sensitive Room-Temperature Sensor Based on Nanostructured K2W7O22 for Application in the Non-Invasive Diagnosis of Diabetes"],"prefix":"10.3390","volume":"18","author":[{"given":"Md Razuan","family":"Hossain","sequence":"first","affiliation":[{"name":"Department of Electrical and Computer Engineering, North Dakota State University, Fargo, ND 58102, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qifeng","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering, North Dakota State University, Fargo, ND 58102, USA"},{"name":"Materials and Nanotechnology Program, North Dakota State University, Fargo, ND 58102, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Johnson","sequence":"additional","affiliation":[{"name":"Materials and Nanotechnology Program, North Dakota State University, Fargo, ND 58102, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0119-441X","authenticated-orcid":false,"given":"Danling","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering, North Dakota State University, Fargo, ND 58102, USA"},{"name":"Materials and Nanotechnology Program, North Dakota State University, Fargo, ND 58102, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2018,10,31]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1109\/JSEN.2009.2035730","article-title":"A Study on Breath Acetone in Diabetic Patients Using a Cavity Ringdown Breath Analyzer: Exploring Correlations of Breath Acetone with Blood Glucose and Glycohemoglobin A1C","volume":"10","author":"Wang","year":"2010","journal-title":"IEEE Sens. J."},{"key":"ref_2","unstructured":"Harris, M.I. (1995). Classification, Diagnostic Criteria, and Screening for Diabetes, Diabetes in America, Chapter II."},{"key":"ref_3","unstructured":"(2018, September 01). National Diabetes Statistics Report, Atlanta, GA, USA, Available online: https:\/\/www.cdc.gov\/diabetes \/data\/statistics\/statistics-report.html."},{"key":"ref_4","unstructured":"Mayo Clinic Staff (2018, September 01). Type 1 Diabetes. Available online: https:\/\/www.mayoclinic.org\/diseases-conditions\/type-1-diabetes\/symptoms-causes\/syc-20353011."},{"key":"ref_5","unstructured":"National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK) (2018, September 01). The A1C Test & Diabetes, Available online: https:\/\/www.niddk.nih.gov\/healthinformation\/diabetes\/overview\/tests-diagnosis\/a1c-test."},{"key":"ref_6","unstructured":"American Diabetes Association (2018, September 01). Diagnosing Diabetes and Learning about Prediabetes. Available online: http:\/\/www.diabetes.org\/diabetes-basics\/diagnosis\/."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"594","DOI":"10.1080\/10473289.1999.10463831","article-title":"Human Breath Emissions of VOCs","volume":"49","author":"Fenske","year":"2011","journal-title":"J. Air Waste Manag. Assoc."},{"key":"ref_8","first-page":"628","article-title":"Mercaptans and dimethyl sulfide in the breath of patients with cirrhosis of the liver. Effect of feeding methionine","volume":"75","author":"Chen","year":"1970","journal-title":"J. Lab. Clin. Med."},{"key":"ref_9","first-page":"30","article-title":"Investigation of humidity cross-interference effect on acetone breath sensor based on nanostructured K2W7O22","volume":"1","author":"Hossain","year":"2017","journal-title":"Eng. Press."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"669","DOI":"10.1038\/nnano.2009.235","article-title":"Diagnosing lung cancer in exhaled breath using gold nanoparticles","volume":"4","author":"Peng","year":"2009","journal-title":"Nat. Nanotechnol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1007\/s00285-010-0398-9","article-title":"A mathematical model for breath gas analysis of volatile organic compounds with special emphasis on acetone","volume":"63","author":"King","year":"2011","journal-title":"J. Math. Biol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"242","DOI":"10.2337\/diab.31.3.242","article-title":"Acetone metabolism during diabetic ketoacidosis","volume":"31","author":"Owen","year":"1982","journal-title":"Diabetes"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"881","DOI":"10.1177\/1932296815572366","article-title":"A Negative Correlation Between Blood Glucose and Acetone Measured in Healthy and Type 1 Diabetes Mellitus Patient Breath","volume":"9","author":"Rydosz","year":"2015","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Turner, C., Walton, C., Hoashi, S., and Evans, M. (2009). Breath acetone concentration decreases with blood glucose concentration in type I diabetes mellitus patients during hypoglycaemic clamps. J. Breath Res., 3.","DOI":"10.1088\/1752-7155\/3\/4\/046004"},{"key":"ref_15","unstructured":"Sun, M., Wang, Z., Yuan, Y., Chen, Z., Zhao, X., Li, Y., and Wang, C. (2017). Continuous Monitoring of Breath Acetone, Blood Glucose and Blood Ketone in 20 Type 1 Diabetic Outpatients Over 30 Days. J. Anal. Bioanal. Tech., 8."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1282","DOI":"10.1016\/S0140-6736(69)92222-3","article-title":"Breath-Acetone and Blood-Sugar Measurements in Diabetes","volume":"293","author":"Tassopou","year":"1969","journal-title":"Lancet"},{"key":"ref_17","unstructured":"Wang, D., and Zhang, Q. (November, January 30). Room temperature acetone sensor based on nanostructured K2W7O22. Proceedings of the IEEE Sensors, Orlando, FL, USA."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"037109","DOI":"10.1088\/1752-7155\/7\/3\/037109","article-title":"Is breath acetone a biomarker of diabetes? A historical review on breath acetone measurements","volume":"7","author":"Wang","year":"2013","journal-title":"J. Breath Res."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1152\/japplphysiol.91657.2008","article-title":"Improved predictive models for plasma glucose estimation from multi-linear regression analysis of exhaled volatile organic compounds","volume":"107","author":"Lee","year":"2009","journal-title":"J. Appl. Physiol."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"526","DOI":"10.1002\/rcm.3402","article-title":"An exploratory comparative study of volatile compounds in exhaled breath and emitted by skin using selected ion flow tube mass spectrometry","volume":"22","author":"Turner","year":"2008","journal-title":"Rapid Commun. Mass Spectrom."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1166","DOI":"10.1152\/ajpendo.00634.2010","article-title":"Noninvasive measurement of plasma glucose from exhaled breath in healthy and type 1 diabetic subjects","volume":"300","author":"Minh","year":"2011","journal-title":"Am. J. Physiol. Endocrinol. Metab."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"71002","DOI":"10.1039\/C5RA07084H","article-title":"Study of breath acetone and its correlations with blood glucose and blood beta-hydroxybutyrate using an animal model with lab-developed type 1 diabetic rats","volume":"5","author":"Sun","year":"2015","journal-title":"RSC Adv."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"037110","DOI":"10.1088\/1752-7155\/7\/3\/037110","article-title":"Correlations between blood glucose and breath components from portable gas sensors and PTR-TOF-MS","volume":"7","author":"Righettoni","year":"2013","journal-title":"J. Breath Res."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/S1570-0232(04)00657-9","article-title":"Determination of acetone in human breath by gas chromatography-mass spectrometry and solid-phase micro extraction with on-fiber derivatization","volume":"810","author":"Deng","year":"2004","journal-title":"J. Chromatogr. B"},{"key":"ref_25","first-page":"961","article-title":"Analysis of organic compounds in human breath by gas chromatography-Mass Spectrometry","volume":"74","author":"Jansson","year":"1969","journal-title":"J. Lab. Clin. Med."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1002\/mas.20033","article-title":"Selected ion flow tube mass spectrometry (SIFT-MS) for on-line trace gas analysis","volume":"24","author":"Smith","year":"2005","journal-title":"Mass Spectrom. Rev."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"861","DOI":"10.1021\/cr800364q","article-title":"Proton-Transfer Reaction Mass Spectrometry","volume":"109","author":"Blake","year":"2009","journal-title":"Chem. Rev."},{"key":"ref_28","unstructured":"Barnes, J. (1992). High Performance Liquid Chromatography, John Wiley & Sons. [2nd ed.]."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"984","DOI":"10.1039\/b404531a","article-title":"Ion mobility spectrometry: A review. Part 1. Structural analysis by mobility measurement","volume":"129","author":"Creaser","year":"2004","journal-title":"Analyst"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1016\/S0039-9140(00)00565-8","article-title":"A critical review of ion mobility spectrometry for the detection of explosives and explosive related compounds","volume":"54","author":"Ewing","year":"2001","journal-title":"Talanta"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"8230","DOI":"10.3390\/s91008230","article-title":"Breath Analysis Using Laser Spectroscopic Techniques: Breath Biomarkers, Spectral Fingerprints, and Detection Limits","volume":"9","author":"Wang","year":"2009","journal-title":"Sensors"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"784","DOI":"10.1366\/0003702041389193","article-title":"Measurements of cavity ringdown spectroscopy of acetone in the ultraviolet and near-infrared spectral regions: Potential for development of a breath analyzer","volume":"58","author":"Wang","year":"2004","journal-title":"Appl. Spectrosc."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"465","DOI":"10.3390\/metabo4020465","article-title":"Breath analysis in disease diagnosis: Methodological considerations and applications","volume":"4","author":"Lourenco","year":"2014","journal-title":"Metabolites"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"7157","DOI":"10.3390\/s120607157","article-title":"A Sub-Ppm Acetone Gas Sensor for Diabetes Detection Using 10 nm Thick Ultrathin InN FETs","volume":"12","author":"Kao","year":"2012","journal-title":"Sensors"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"2322","DOI":"10.1109\/JSEN.2017.2662716","article-title":"Enhanced low-temperature response of PPy-WO3 hybrid nanocomposite based gas sensor deposited by electrospinning method for selective and sensitive acetone detection","volume":"17","author":"Jamalabadi","year":"2017","journal-title":"IEEE Sens. J."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1109\/LED.2017.2647831","article-title":"Fast Response (7.6s) Acetone Sensing by InGaN\/GaN on Si (111) at 373 K","volume":"38","author":"Das","year":"2017","journal-title":"IEEE Electron Device Lett."},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Hazra, A., Bhowmik, B., Dutta, K., and Bhattacharyya, P. (2013, January 3\u20135). Low Temperature Low ppm Acetone Detection by Pd\/TiO2\/p-Si Metal-Insulator-Semiconductor Devices. Proceedings of the 2013 Seventh International Conference on Sensing Technology (ICST), Wellington, New Zealand.","DOI":"10.1109\/ICSensT.2013.6727683"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"4399","DOI":"10.1109\/JSEN.2018.2825302","article-title":"High Sensitive Breath Sensor Based on Nanostructured K2W7O22 for Detection of Type 1 Diabetes","volume":"18","author":"Wang","year":"2018","journal-title":"IEEE Sens. J."},{"key":"ref_39","unstructured":"(2018, September 01). Operational Amplifier. Available online: https:\/\/en.wikipedia.org\/wiki\/Operational_amplifier."},{"key":"ref_40","unstructured":"(2018, September 01). Wheatstone Bridge. Available online: https:\/\/en.wikipedia.org\/wiki\/Wheatstone_bridge."},{"key":"ref_41","unstructured":"(2018, September 01). LM741CN-NOPB. Available online: https:\/\/www.digikey.com\/product-detail\/en\/texas-instruments\/LM741CN NOPB\/LM741CNNS-NOPB-ND\/6322."},{"key":"ref_42","unstructured":"(2018, September 01). Oshpark. Available online: https:\/\/oshpark.com\/."},{"key":"ref_43","unstructured":"(2018, September 01). SPDT Switch. Available online: http:\/\/www.learningaboutelectronics.com\/Articles\/What-is-a-single-pole-double-throw-switch-SPDT."},{"key":"ref_44","unstructured":"(2018, September 01). Op-Amp Buffer. Available online: https:\/\/www.eecs.tufts.edu\/~dsculley\/tutorial\/opamps\/opamps5.html."},{"key":"ref_45","unstructured":"(2018, September 01). Electrostatic Interactions. Available online: https:\/\/www.sciencedirect.com\/topics\/chemistry\/electrostatic-interactions."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"5469","DOI":"10.3390\/s100605469","article-title":"Metal Oxide Semi-Conductor Gas Sensors in Environmental Monitoring","volume":"10","author":"Fine","year":"2010","journal-title":"Sensors"},{"key":"ref_47","unstructured":"(2018, October 15). Chemical Sensors. Available online: https:\/\/www.nap.edu\/read\/4782\/chapter\/10#74."},{"key":"ref_48","unstructured":"(2018, October 15). Sensor. Available online: https:\/\/en.wikipedia.org\/wiki\/Sensor."},{"key":"ref_49","doi-asserted-by":"crossref","unstructured":"Kargar, A. (2008, January 18\u201321). Sensitivity Analysis of Silicon Nanowire Chemical Sensor. Proceedings of the 8th IEEE Conference on Nanotechnology, Arlington, TX, USA.","DOI":"10.1109\/NANO.2008.70"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/11\/3703\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T15:27:10Z","timestamp":1760196430000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/11\/3703"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,10,31]]},"references-count":49,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2018,11]]}},"alternative-id":["s18113703"],"URL":"https:\/\/doi.org\/10.3390\/s18113703","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,10,31]]}}}