{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,4]],"date-time":"2026-04-04T02:53:31Z","timestamp":1775271211378,"version":"3.50.1"},"reference-count":46,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2018,11,11]],"date-time":"2018-11-11T00:00:00Z","timestamp":1541894400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Joint replacement surgeries have enabled motion for millions of people suffering from arthritis or grave injuries. However, over 10% of these surgeries are revision surgeries. We have first analyzed the data from the worldwide orthopedic registers and concluded that the micromotion of orthopedic implants is the major reason for revisions. Then, we propose the use of inductive eddy current sensors for in vivo micromotion detection of the order of tens of \u03bc m. To design and evaluate its characteristics, we have developed efficient strategies for the accurate numerical simulation of eddy current sensors implanted in the human body. We present the response of the eddy current sensor as a function of its frequency and position based on the robust curve fit analysis. Sensitivity and Sensitivity Range parameters are defined for the present context and are evaluated. The proposed sensors are fabricated and tested in the bovine leg.<\/jats:p>","DOI":"10.3390\/s18113888","type":"journal-article","created":{"date-parts":[[2018,11,14]],"date-time":"2018-11-14T10:58:22Z","timestamp":1542193102000},"page":"3888","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Design, Modeling, and Evaluation of the Eddy Current Sensor Deeply Implanted in the Human Body"],"prefix":"10.3390","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8723-2597","authenticated-orcid":false,"given":"Rajas Prakash","family":"Khokle","sequence":"first","affiliation":[{"name":"School of Engineering, Macquarie University, Sydney 2109, NSW, Australia"}]},{"given":"Karu P.","family":"Esselle","sequence":"additional","affiliation":[{"name":"School of Engineering, Macquarie University, Sydney 2109, NSW, Australia"}]},{"given":"Desmond J.","family":"Bokor","sequence":"additional","affiliation":[{"name":"Faculty of Medicine and Health Sciences, Macquarie University, Sydney 2109, NSW, Australia"}]}],"member":"1968","published-online":{"date-parts":[[2018,11,11]]},"reference":[{"key":"ref_1","unstructured":"(2015). Australian Orthopaedic Association Hip and Knee Arthroplasty Annual Report, Available online: https:\/\/aoanjrr.sahmri.com\/annual-reports-2015."},{"key":"ref_2","unstructured":"(2015). Australian Orthopaedic Association Shoulder Arthroplasty Annual Report, Available online: https:\/\/aoanjrr.sahmri.com\/annual-reports-2015."},{"key":"ref_3","unstructured":"(2015). The New Zealand Joint Registery Annual Report, Available online: https:\/\/nzoa.org.nz\/system\/files\/NZJR2014Report.pdf."},{"key":"ref_4","unstructured":"(2015). 12th Annual National Joint Registry Report for England, Wales, Northern Ireland and the Isle of Man, Available online: https:\/\/www.hqip.org.uk\/resource\/national-joint-registry-12th-annual-report-2015\/#.W-P_rfYRVKI."},{"key":"ref_5","unstructured":"(2015). 1st Annual Report, Portugese Arthroplasty Register, Available online: http:\/\/www.rpa.spot.pt\/Quick-Links\/Home\/RPA_first_anual_report.aspx."},{"key":"ref_6","unstructured":"(2016, December 11). Online LROI Annual Report Dutch Arthroplasty Register. Available online: http:\/\/www.lroi-rapportage.nl."},{"key":"ref_7","unstructured":"(2014). American Joint Replacement Registry Annual Report, Available online: http:\/\/www.ajrr.net\/images\/annual_reports\/AJRR_2014_Annual_Report_final_11-11-15.pdf."},{"key":"ref_8","unstructured":"(2014). SIRIS Report 2012\u20132015, Annual Report of the Swiss National Joint Registry, Hip and Knee, National Association for Quality Development in Hospitals and Clinics. Available online: http:\/\/www.swissorthopaedics.ch\/images\/content\/SIRIS\/170516_SIRISAnnualReport2015_Finalcopie.pdf."},{"key":"ref_9","unstructured":"(2016, December 11). Orthopride Belgian Hip and Knee Arthroplasty Registry Annual Report 2014, Available online: https:\/\/www.ehealth.fgov.be\/file\/view\/5fca367bad5fd36bf017d1363087849a."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Niwa, S., Yoshino, S., Kurosaka, M., Shino, K., and Yamamoto, S. (1996). Reconstruction of the Knee Joint, Springer.","DOI":"10.1007\/978-4-431-68464-0"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1016\/0022-3913(85)90460-3","article-title":"Tissue-Integrated Prostheses: Osseointegration in Clinical Dentistry","volume":"54","author":"Zarb","year":"1985","journal-title":"J. Prosthet. Dent."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"255","DOI":"10.4055\/cios.2017.9.3.255","article-title":"Porous Femoral Fixation in Total Hip Arthroplasty with Short Anatomical Stem: Radiographic Evaluation","volume":"9","author":"Patil","year":"2017","journal-title":"Clin. Orthop. Surg."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Laskin, R.S. (1991). Total Knee Replacement, Springer.","DOI":"10.1007\/978-1-4471-1825-1"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1016\/S0883-5403(99)90063-3","article-title":"Implant Fixation by Bone Ingrowth","volume":"14","author":"Kienapfel","year":"1999","journal-title":"J. Arthroplast."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"944","DOI":"10.1016\/0142-9612(92)90118-8","article-title":"Effect of amplitude of micromotion on bone ingrowth into titanium chambers implanted in the rabbit tibia","volume":"13","author":"Goodman","year":"1992","journal-title":"Biomaterials"},{"key":"ref_16","first-page":"192","article-title":"Timing of Loading and Effect of Micromotion on Bone\u2013Dental Implant Interface: Review of Experimental Literature","volume":"43","author":"Salama","year":"1997","journal-title":"J. Biomed. Mater. Res. Appl. Biomater."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Liu, X., and Niebur, G.L. (2008). Bone ingrowth into a porous coated implant predicted by a mechano-regulatory tissue differentiation algorithm. Biomech. Model. Mechanobiol.","DOI":"10.1007\/s10237-007-0100-3"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/S0883-5403(06)80105-1","article-title":"The contribution of the nonporous distal stem to the stability of proximally porous-coated canine femoral components","volume":"8","author":"Jasty","year":"1993","journal-title":"J. Arthroplast."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"994","DOI":"10.1016\/j.knee.2017.07.003","article-title":"Computational modelling of motion at the bone-implant interface after total knee arthroplasty: The role of implant design and surgical fit","volume":"24","author":"Conlisk","year":"2017","journal-title":"Knee"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1302\/0301-620X.89B4.18055","article-title":"The initial stability and contact mechanics of a press-fit resurfacing arthroplasty of the hip","volume":"89","author":"Udofia","year":"2007","journal-title":"Bone Jt. J."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"141","DOI":"10.3109\/17453679209154809","article-title":"Intermittent micromotion inhibits bone ingrowth","volume":"63","author":"Aspenberg","year":"1992","journal-title":"Acta Orthop. Scand."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1097\/01.ID.0000034394.75768.E3","article-title":"Osseointegration under immediate loading: Biomechanical stress-strain and bone formation\u2013resorption","volume":"12","author":"Kawahara","year":"2003","journal-title":"Implant Dent."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1232","DOI":"10.1016\/j.jbiomech.2012.01.040","article-title":"Simultaneous and multisite measure of micromotion, subsidence and gap to evaluate femoral stem stability","volume":"45","author":"Gortchacow","year":"2012","journal-title":"J. Biomech."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1097\/00003086-198607000-00023","article-title":"Observations on the effect of movement on bone ingrowth into porous-surfaced implants","volume":"208","author":"Pilliar","year":"1986","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_25","first-page":"1232","article-title":"In vivo skeletal responses to porous-surfaced implants subjected to small induced motions","volume":"79","author":"Bragdon","year":"1997","journal-title":"J. Bone Jt. Surg. Am."},{"key":"ref_26","first-page":"289","article-title":"Determination of Micromotion at the Implant Bone Interface\u2014An In-Vitro Methodologic Study","volume":"5","author":"Karl","year":"2015","journal-title":"Dentistry"},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Varga, M., and Wolter, K.J. (2014, January 23\u201326). Sensors and imaging methods for detecting loosening of orthopedic implants\u2014A review. Proceedings of the IEEE 20th International Symposium for Design and Technology in Electronic Packaging, Bucharest, Romania.","DOI":"10.1109\/SIITME.2014.6966990"},{"key":"ref_28","first-page":"496","article-title":"Alloarthroplasty of the hip joint. Radiologic diagnosis of loosening and infection in cemented total endoprostheses","volume":"31","author":"Dihlmann","year":"1991","journal-title":"Radiologe"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1163","DOI":"10.1016\/j.crad.2007.04.018","article-title":"CT and MRI of hip arthroplasty","volume":"62","author":"Cahir","year":"2007","journal-title":"Clin. Radiol."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1016\/j.arth.2008.04.023","article-title":"Magnetic Resonance Imaging in the Diagnosis and Management of Hip Pain After Total Hip Arthroplasty","volume":"24","author":"Cooper","year":"2009","journal-title":"J. Arthroplast."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1231","DOI":"10.1007\/s00402-009-1000-z","article-title":"Use of 18F-FDG-PET in the diagnosis of endoprosthetic loosening of knee and hip implants","volume":"130","author":"Mayer","year":"2010","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"3","DOI":"10.3109\/17453678609157924","article-title":"Micromotion in knee arthroplasty","volume":"57","author":"Ryd","year":"1986","journal-title":"Acta Orthop. Scand."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"4002","DOI":"10.1016\/j.jbiomech.2016.10.029","article-title":"Full-field measurement of micromotion around a cementless femoral stem using micro-CT imaging and radiopaque markers","volume":"49","author":"Camine","year":"2016","journal-title":"J. Biomech."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1016\/S0268-0033(01)00002-X","article-title":"Accurate diagnosis of hip prostehsis loosening using a vibrational techniques","volume":"16","author":"Georgiou","year":"2001","journal-title":"Clin. Biomech."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"1126","DOI":"10.1109\/TIM.2005.847198","article-title":"The design and development of a measurement system for the investigation of dynamic micromotion in total knee joint replacements","volume":"54","author":"DiSilvestro","year":"2005","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"1165","DOI":"10.1002\/jor.22354","article-title":"Micromotions at the taper interface between stem and neck adapter of a bimodular hip prosthesis during activities of daily living","volume":"31","author":"Jauch","year":"2013","journal-title":"J. Orthop. Res."},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Khokle, R., Esselle, K., Heimlich, M., and Bokor, D. (2017, January 13\u201315). Orthopaedic implant micromotion sensing using an eddy current sensor. Proceedings of the 2017 IEEE Life Sciences Conference (LSC), Sydney, Australia.","DOI":"10.1109\/LSC.2017.8268159"},{"key":"ref_38","unstructured":"Wilson, J.S. (2005). Sensor Technology Handbook, Elsevier."},{"key":"ref_39","unstructured":"Lai, Y. (2014). Eddy Current Displacement Sensor with LTCC Technology. [Ph.D. Thesis, Albert Ludwigs University of Freiburg]."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"557","DOI":"10.6028\/jres.105.045","article-title":"Equations for the Magnetic Field Produced by One or More Rectangular Loops of Wire in the Same Plane","volume":"105","author":"Misakian","year":"2000","journal-title":"J. Res. Natl. Inst. Stand. Technol."},{"key":"ref_41","unstructured":"Cho, K., and Itakura, H. (1992, January 22). Input Impedance Characteristics of Small Rectangular Loop Antenna. Proceedings of the ISAP Sapporo Japan, Sapporo, Japan."},{"key":"ref_42","unstructured":"May, P., and Zhou, E. (2012). Numerical Modelling, InTech. Available online: https:\/\/www.intechopen.com\/download\/pdf\/33083."},{"key":"ref_43","unstructured":"Kuo, L.C., Chen, W.T., and Chuang, H.R. (2001, January 3\u20136). Numerical computation of human body effects on radiation characteristics of loop antennas for watch-type wrist radiophone application. Proceedings of the Asia-Pacific Microwave Conference (Cat. No. 01TH8577), Taipei, Taiwan."},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Kracek, J., Svanda, M., Mazanek, M., and Machac, J. (2016, January 4\u20136). Semi-active 866 MHz RFID implantable tag fed by 6.78 MHz inductive wireless power transfer. Proceedings of the 46th European Microwave Conference (EuMC), London, UK.","DOI":"10.1109\/EuMC.2016.7824419"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"1657","DOI":"10.1109\/LAWP.2016.2520663","article-title":"Implantable Semi-Active UHF RFID Tag with Inductive Wireless Power Transfer","volume":"15","author":"Kracek","year":"2016","journal-title":"IEEE Antennas Wirel. Propag. Lett."},{"key":"ref_46","doi-asserted-by":"crossref","unstructured":"Khokle, R.P., Esselle, K.P., Heimlich, M., and Bokor, D. (2017, January 13\u201314). Design of a miniaturized bone implantable antenna for a wireless implant monitoring device. Proceedings of the Loughborough Antennas Propagation Conference (LAPC 2017), Loughborough, UK.","DOI":"10.1049\/cp.2017.0254"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/11\/3888\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,4]],"date-time":"2026-04-04T02:01:51Z","timestamp":1775268111000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/11\/3888"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,11,11]]},"references-count":46,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2018,11]]}},"alternative-id":["s18113888"],"URL":"https:\/\/doi.org\/10.3390\/s18113888","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,11,11]]}}}