{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,24]],"date-time":"2026-03-24T11:35:55Z","timestamp":1774352155813,"version":"3.50.1"},"reference-count":31,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2018,11,22]],"date-time":"2018-11-22T00:00:00Z","timestamp":1542844800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Development of new, faster methods of biosensor construction is a huge challenge for current science and industry. In this work, biosensor construction was carried out using a new soft plasma polymerization (SPP) method in which a bio-recognition layer of laccase enzyme was polymerized and bonded to a glassy carbon electrode (GCE) substrate under atmospheric pressure with a corona discharge jet. Laccase belongs to the oxidoreductase enzyme group with four copper atoms in its active center. Application of the corona SPP plasma method allows reduction of the time needed for biosensor construction from several hours to minutes. The presented work includes optimization of the laccase bio-recognition layer deposition time, structural studies of the deposited laccase layer, as well as study of the fabricated biosensor applicability for the determination of Rutin in real pharmaceutical samples. This method produces a biosensor with two linear ranges from 0.3 \u03bcmol\/dm3 to 0.5 \u03bcmol\/dm3 and from 0.8 \u03bcmol\/dm3 to 16 \u03bcmol\/dm3 of Rutin concentration. Results shown in this work indicate that application of the one-step, corona SPP method enables biosensor construction with comparable analytical parameters to biosensors fabricated by conventional, multi-step, wet methods.<\/jats:p>","DOI":"10.3390\/s18124086","type":"journal-article","created":{"date-parts":[[2018,11,22]],"date-time":"2018-11-22T09:18:25Z","timestamp":1542878305000},"page":"4086","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":24,"title":["Cold Plasma as an Innovative Construction Method of Voltammetric Biosensor Based on Laccase"],"prefix":"10.3390","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9437-9757","authenticated-orcid":false,"given":"Szymon","family":"Malinowski","sequence":"first","affiliation":[{"name":"Faculty of Civil Engineering and Architecture, Lublin University of Technology, Nadbystrzycka 40, 20-618 Lublin, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cecylia","family":"Wardak","sequence":"additional","affiliation":[{"name":"Department of Analytical Chemistry and Instrumental Analysis, Faculty of Chemistry, Maria Curie-Sklodowska University, Maria Curie-Sklodowska Sq. 3, 20-031 Lublin, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Justyna","family":"Jaroszy\u0144ska-Woli\u0144ska","sequence":"additional","affiliation":[{"name":"Faculty of Civil Engineering and Architecture, Lublin University of Technology, Nadbystrzycka 40, 20-618 Lublin, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P. Anthony F.","family":"Herbert","sequence":"additional","affiliation":[{"name":"Plasma Ireland, 22 Summerhill North, T23 N592 Cork, Ireland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rafa\u0142","family":"Panek","sequence":"additional","affiliation":[{"name":"Faculty of Civil Engineering and Architecture, Lublin University of Technology, Nadbystrzycka 40, 20-618 Lublin, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2018,11,22]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1016\/j.trac.2007.03.003","article-title":"Plasma-polymerized films for biosensors II","volume":"26","author":"Mugumura","year":"2007","journal-title":"Trends Anal. Chem."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1016\/j.trac.2015.05.008","article-title":"Laccase-based biosensors for detection of phenolic compounds","volume":"74","author":"Barcelo","year":"2015","journal-title":"Trends Anal. Chem."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"4811","DOI":"10.3390\/s130404811","article-title":"Immobilization techniques in the fabrication of nanomaterial-based electrochemical biosensors: A review","volume":"13","author":"Putzbach","year":"2013","journal-title":"Sensors"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1016\/S0031-9422(02)00171-1","article-title":"Laccase: New functions for an old enzyme","volume":"60","author":"Mayer","year":"2002","journal-title":"Phytochemistry"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1016\/j.jsps.2016.04.025","article-title":"The pharmacological potential of Rutin","volume":"25","author":"Ganesphurkar","year":"2017","journal-title":"Saudi Pharm. J."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1016\/j.bios.2012.08.040","article-title":"Sensitive detection of rutin with novel ferrocene benzyne derivative modified electrodes","volume":"41","author":"Liu","year":"2013","journal-title":"Biosens. Bioelectron."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"805","DOI":"10.1016\/j.jep.2013.10.036","article-title":"A review on plant-based rutin extraction methods and its pharmacological activities","volume":"150","author":"Chua","year":"2013","journal-title":"J. Ethnopharmacol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1322","DOI":"10.1016\/j.talanta.2008.09.010","article-title":"Biosensor based on laccase and an ionic liquid for determination of rosmarinic acid in plant extracts","volume":"77","author":"Franzoi","year":"2009","journal-title":"Talanta"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1016\/j.snb.2012.12.118","article-title":"Graphene-MnO2 nanocomposite modified carbon ionic liquid electrode for the sensitive electrochemical detection of rutin","volume":"178","author":"Sun","year":"2013","journal-title":"Sens. Actuators B"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"973","DOI":"10.1016\/j.jpba.2008.03.031","article-title":"Rutin determination in pharmaceutical formulations using a carbon paste electrode modified with poly (vinylpyrrolidone)","volume":"47","author":"Franzoi","year":"2008","journal-title":"J. Pharm. Biomed. Anal."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.jelechem.2014.08.018","article-title":"Supersensitive electrochemical sensor for the fast determination of rutin in pharmaceuticals and biological samples based on poly (diallyldimethylammonium chloride)-functionalized graphene","volume":"732","author":"Miao","year":"2014","journal-title":"J. Electroanal. Chem."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.jelechem.2010.04.019","article-title":"Gold nanoparticles\/ethylenediamine\/carbon nanotube modified glassy carbon electrode as the voltammetric sensor for selective determination of rutin in the presence of ascorbic acid","volume":"645","author":"Yang","year":"2010","journal-title":"J. Electroanal. Chem."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1016\/j.snb.2009.04.037","article-title":"Biosensor based on platinum nanoparticles dispersed in ionic liquid and laccase for determination of adrenaline","volume":"140","author":"Brondani","year":"2009","journal-title":"Sens. Actuators B Chem."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jfca.2011.04.013","article-title":"Cathodic adsorptive stripping voltammetric determination of rutin in soybean cultivars","volume":"25","author":"SauzaDe","year":"2012","journal-title":"J. Food Composit. Anal."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1002\/elan.200503433","article-title":"Determination of rutin in pharmaceutical compounds and tea using cathodic adsorptive stripping voltammetry","volume":"18","author":"Ensafi","year":"2006","journal-title":"Electroanalysis"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1081\/AL-120003169","article-title":"Investigation on the electrochemistry of rutin and its analytical application","volume":"35","author":"Kang","year":"2006","journal-title":"Anal. Lett."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1016\/j.ijbiomac.2011.11.022","article-title":"An amperometric biosensor based on laccase immobilized onto MnO2\/cMWCNT\/PANI modified electrode","volume":"51","author":"Rawal","year":"2012","journal-title":"Int. J. Biol. Macromol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"5591","DOI":"10.1016\/j.electacta.2007.02.008","article-title":"Electroreduction of laccase covalently bound to organothiol monolayers on gold electrodes","volume":"52","author":"Klis","year":"2007","journal-title":"Electrochim. Acta"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1577","DOI":"10.1002\/elan.200302724","article-title":"Laccase biosensor on monolayer-modified gold electrode","volume":"15","author":"Gupta","year":"2003","journal-title":"Electroanalysis"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1016\/j.teac.2017.02.001","article-title":"Nanomaterials based electrochemical sensor and biosensor platforms for environmental applications","volume":"13","author":"Maduraiveeran","year":"2017","journal-title":"Trends Anal. Chem."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1007\/s00604-006-0716-5","article-title":"Determination of rutin using a CeO2 nanoparticle-modified electrode","volume":"158","author":"Wei","year":"2007","journal-title":"Microchim. Acta"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1337","DOI":"10.1016\/j.elecom.2007.01.042","article-title":"Activity and stability of horseradish peroxidase in hydrophilic room temperature ionic liquid and its application in non-aqueous biosensing","volume":"9","author":"Wang","year":"2007","journal-title":"Electrochem. Commun."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Jaroszy\u0144ska-Woli\u0144ska, J., Malinowski, S., Herbert, P.A.F., and Wardak, C. (2017, January 3\u20136). Laccase biosensors from bio-coatings deposited by corona plasma SPP for rutin determination. Proceedings of the 2017 International Conference on Electromagnetic Devices and Processes in Environment Protection with Seminar Applications of Superconductors, ELMECO and AoS 2017, Lublin, Poland.","DOI":"10.1109\/ELMECO.2017.8267752"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"532","DOI":"10.3390\/polym10050532","article-title":"Laccase enzyme polymerization by soft plasma jet for durable bioactive coatings","volume":"10","author":"Malinowski","year":"2018","journal-title":"Polymers"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"4401","DOI":"10.1021\/cm900816e","article-title":"Soft plasma polymerization of gas state precursors from an atmospheric pressure corona plasma discharge","volume":"21","author":"Herbert","year":"2009","journal-title":"Chem. Mater."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"297","DOI":"10.5109\/1526341","article-title":"The large scale production of cerrena unicolor laccase on waste agricultural based media","volume":"60","author":"Rola","year":"2015","journal-title":"J. Fac. Agric. Kyushu Univ."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"166","DOI":"10.3390\/s30600166","article-title":"A new laccase biosensor for polyphenols determination","volume":"3","author":"Gomes","year":"2003","journal-title":"Sensors"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/j.aca.2009.03.012","article-title":"Development of biosensors containing laccase and imidazolium bis. (trifluoromethylsulfonyl) imide ionic liquid for the determination of rutin","volume":"639","author":"Franzoi","year":"2009","journal-title":"Anal. Chim. Acta"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1016\/j.microc.2010.05.004","article-title":"Laccase-polyazetidine prepolymer-MWCNT integrated system: Biochemical properties and application to analytical determinations in real samples","volume":"96","author":"Tortolini","year":"2010","journal-title":"Microchem. J."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1016\/j.snb.2008.02.023","article-title":"Biosensor based on laccase immobilized on microspheres of chitosan crosslinked with tripoliphosphate","volume":"133","author":"Fernandes","year":"2008","journal-title":"Sens. Actuators B"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1016\/j.bios.2004.08.024","article-title":"Biosensor for determination of phenols based on Cross-Linked Enzyme Crystals (CLEC) of laccase","volume":"21","author":"Roy","year":"2005","journal-title":"Biosens. Bioelectron."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/12\/4086\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T15:31:21Z","timestamp":1760196681000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/12\/4086"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,11,22]]},"references-count":31,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2018,12]]}},"alternative-id":["s18124086"],"URL":"https:\/\/doi.org\/10.3390\/s18124086","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,11,22]]}}}