{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,8]],"date-time":"2025-11-08T17:48:26Z","timestamp":1762624106052,"version":"build-2065373602"},"reference-count":18,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2018,12,11]],"date-time":"2018-12-11T00:00:00Z","timestamp":1544486400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"National Science and Technology Major Project of China","award":["2011ZX069"],"award-info":[{"award-number":["2011ZX069"]}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["61305065"],"award-info":[{"award-number":["61305065"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Inductive transducers are widely applied to active magnetic bearings (AMBs). However, when the rotor rotates at a high speed, the rotor defects will affect the measuring signal (the magnetic field generated by transducer coils) and then reduce the transducer measuring accuracy. The rotor in AMBs is assembled with laminations, which will result in rotor non-mechanical errors. In this paper, rotor non-mechanical errors, including the anisotropic internal permeability and anisotropic surface conductivity, and their influence on double-pole variable-gap inductive transducers are explored in depth. The anisotropic internal permeability will affect the transducer measuring accuracy and bring about     1.3 \u00b1 0.1 %     measurement error. The anisotropic surface conductivity leads to different eddy currents around the rotor, influences the equivalent reluctance of the magnetic circuit, and then affectsthe transducer measuring accuracy. The experiments prove that rotor non-mechanical errors have a significant influence on transducer measurement accuracy, and the reduction of the transducer excitation frequency can reduce the measurement error and improve the AMB control performance.<\/jats:p>","DOI":"10.3390\/s18124376","type":"journal-article","created":{"date-parts":[[2018,12,12]],"date-time":"2018-12-12T03:27:49Z","timestamp":1544585269000},"page":"4376","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Theoretical and Experimental Analysis on the Influence of Rotor Non-Mechanical Errors of the Inductive Transducer in Active Magnetic Bearings"],"prefix":"10.3390","volume":"18","author":[{"given":"Jinpeng","family":"Yu","sequence":"first","affiliation":[{"name":"Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084, China"},{"name":"Collaborative Innovation Center of Advanced Nuclear Energy Technology, Tsinghua University, Beijing 100084, China"},{"name":"The Key Laboratory of Advanced Reactor Engineering and Safety, Tsinghua University, Beijing 100084, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yan","family":"Zhou","sequence":"additional","affiliation":[{"name":"Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084, China"},{"name":"Collaborative Innovation Center of Advanced Nuclear Energy Technology, Tsinghua University, Beijing 100084, China"},{"name":"The Key Laboratory of Advanced Reactor Engineering and Safety, Tsinghua University, Beijing 100084, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ni","family":"Mo","sequence":"additional","affiliation":[{"name":"Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084, China"},{"name":"Collaborative Innovation Center of Advanced Nuclear Energy Technology, Tsinghua University, Beijing 100084, China"},{"name":"The Key Laboratory of Advanced Reactor Engineering and Safety, Tsinghua University, Beijing 100084, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1482-5201","authenticated-orcid":false,"given":"Zhe","family":"Sun","sequence":"additional","affiliation":[{"name":"Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084, China"},{"name":"Collaborative Innovation Center of Advanced Nuclear Energy Technology, Tsinghua University, Beijing 100084, China"},{"name":"The Key Laboratory of Advanced Reactor Engineering and Safety, Tsinghua University, Beijing 100084, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lei","family":"Zhao","sequence":"additional","affiliation":[{"name":"Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084, China"},{"name":"Collaborative Innovation Center of Advanced Nuclear Energy Technology, Tsinghua University, Beijing 100084, China"},{"name":"The Key Laboratory of Advanced Reactor Engineering and Safety, Tsinghua University, Beijing 100084, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2018,12,11]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1177\/058310240003200201","article-title":"An overview of active magnetic bearing technology and applications","volume":"32","author":"Kasarda","year":"2000","journal-title":"Shock Vib. Dig."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"3515","DOI":"10.1299\/kikaic.65.3515","article-title":"Aseismatic vibration control on active magnetic bearing equipped flexible rotors","volume":"65","author":"Imashima","year":"2016","journal-title":"Trans. Jpn. Soc. Mech. Eng. Ser. C"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1115\/1.1569946","article-title":"The effect of actuator and sensor placement on the active control of rotor unbalance","volume":"125","author":"Johnson","year":"2003","journal-title":"J. Vib. Acoust."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1016\/j.ymssp.2014.05.004","article-title":"Identification of active magnetic bearing system with a flexible rotor","volume":"49","author":"Sun","year":"2014","journal-title":"Mech. Syst. Signal Process."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1016\/j.ymssp.2018.01.010","article-title":"Application of active magnetic bearings in flexible rotordynamic systems\u2014A state-of-the-art review","volume":"106","author":"Tiwari","year":"2018","journal-title":"Mech. Syst. Signal Process."},{"key":"ref_6","unstructured":"Jianfeng, Z. (2016). The Influence of Anisotropic of Silicon Steel Sheet on Measurement Accuracy of Inductive Displacement Sensor, Tsinghua University. (In Chinese)."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1482","DOI":"10.1109\/JSEN.2006.884439","article-title":"Microfabricated Inductive Micropositioning Sensor for Measurement of a Linear Movement","volume":"6","author":"Dinulovic","year":"2006","journal-title":"IEEE Sens. J."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"FeLix, M., LizaRraga, A., Islas, A., and GonzaLez, A. (2010, January 7\u201310). Analysis of a ferrofluid core LVDT displacement sensor. Proceedings of the IECON 2010-36th Annual Conference on IEEE Industrial Electronics Society, Glendale, AZ, USA.","DOI":"10.1109\/IECON.2010.5675411"},{"key":"ref_9","unstructured":"Hossain, A., and Dwyer, M.J. (2001, January 5\u20137). A new type of liquid density transducer based on the principle of linear variable differential transformer. Proceedings of the First ISA\/IEEE Sensors for Industry Conference, Rosemount, IL, USA."},{"key":"ref_10","unstructured":"Bayley, A. (2014, January 24\u201325). Fail-safe LVDT position sensor for measurements in harsh environment. Proceedings of the 7th GMM-Workshop on Energy self-sufficient Sensors, Magdeburg, Germany."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Sahu, D., Hazra, S., and Nandi, P. (2016, January 4\u20138). Modeling of Linear Variable Differential Transformer. Proceedings of the 2016 29th International Conference on VLSI Design and 2016 15th International Conference on Embedded Systems (VLSID), Kolkata, India.","DOI":"10.1109\/VLSID.2016.75"},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Masi, A., Danisi, A., Losito, R., Martino, M., and Spiezia, G. (2010, January 3\u20136). Study of magnetic interference on a LVDT prototype. Proceedings of the 2010 IEEE Instrumentation & Measurement Technology Conference Proceedings, Austin, TX, USA.","DOI":"10.1109\/IMTC.2010.5488091"},{"key":"ref_13","unstructured":"Committee of Weapon-Industry Non-destructive Testing and Personnel Technical Qualification Appraisal (2003). Quick Manual for Common Steel Magnetic Characteristic Curve, China Machine Press. (In Chinese)."},{"key":"ref_14","unstructured":"Guoping, D. (2004). Analysis and Measurement Research on Electromagnetic Field for Magnetic Bearings, Wuhan University of Technology. (In Chinese)."},{"key":"ref_15","unstructured":"Guoping, D. (2004). Related Theory and Measurement Research on Magnetic Bearing Electromagnetic Field, Wuhan University of Technology. (In Chinese)."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Wang, G.J., Wang, P., and Wang, X.Y. (2016, January 19). Analyze of permanent magnet loss of high speed permanent magnet synchronous motor for flywheel energy storage system. Proceedings of the 2015 IEEE International Conference on Applied Superconductivity and Electromagnetic Devices (ASEMD), Shanghai, China.","DOI":"10.1109\/ASEMD.2015.7453699"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1049\/iet-smt.2011.0216","article-title":"Electromagnetic fields generated by arbitrarily shaped current loops","volume":"6","author":"Griffith","year":"2012","journal-title":"Iet Sci. Meas. Technol."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Long, Z., and Li, C. (2010, January 23\u201324). Numerical Simulation of Air Gap Magnetic Field of Eddy-current Retarder. Proceedings of the International Conference on Artificial Intelligence and Computational Intelligence, Sanya, China.","DOI":"10.1109\/AICI.2009.378"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/12\/4376\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T15:33:04Z","timestamp":1760196784000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/12\/4376"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,12,11]]},"references-count":18,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2018,12]]}},"alternative-id":["s18124376"],"URL":"https:\/\/doi.org\/10.3390\/s18124376","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2018,12,11]]}}}