{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T02:47:16Z","timestamp":1775011636540,"version":"3.50.1"},"reference-count":23,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2018,12,13]],"date-time":"2018-12-13T00:00:00Z","timestamp":1544659200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>In most commercial single-element intravascular ultrasound (IVUS) transducers, with 20 MHz to 40 MHz center frequencies, a conductive adhesive is used to bond a micro-sized cable for the signal line to the surface of the transducer aperture (&lt;1 mm \u00d7 1 mm size) where ultrasound beam is generated. Therefore, the vibration of the piezoelectric layer is significantly disturbed by the adhesive with the signal line, thereby causing problems, such as reduced sensitivity, shortened penetration depth, and distorted beam profile. This phenomenon becomes more serious as the center frequency of the IVUS transducer is increased, and the aperture size becomes small. Therefore, we propose a novel IVUS acoustic stack employing asymmetric electrodes with conductive and non-conductive backing blocks. The purpose of this study is to verify the extent of performance degradation caused by the adhesive with the signal line, and to demonstrate how much performance degradation can be minimized by the proposed scheme. Finite element analysis (FEA) simulation was conducted, and the results show that \u22123 dB, \u22126 dB, and \u221210 dB penetration depths of the conventional transducer were shortened by 20%, 25%, and 19% respectively, while those of the proposed transducer were reduced only 3%, 4%, and 0% compared with their ideal transducers which have the same effective aperture size. Besides, the proposed transducer improved the \u22123 dB, \u22126 dB, and \u221210 dB penetration depths by 15%, 12%, and 10% respectively, compared with the conventional transducer. We also fabricated a 60 MHz IVUS transducer by using the proposed technique, and high-resolution IVUS B-mode (brightness mode) images were obtained. Thus, the proposed scheme can be one of the potential ways to provide more uniform beam profile resulting in improving the signal to noise ratio (SNR) in IVUS image.<\/jats:p>","DOI":"10.3390\/s18124414","type":"journal-article","created":{"date-parts":[[2018,12,14]],"date-time":"2018-12-14T03:58:17Z","timestamp":1544759897000},"page":"4414","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":22,"title":["Development of High-Frequency (&gt;60 MHz) Intravascular Ultrasound (IVUS) Transducer by Using Asymmetric Electrodes for Improved Beam Profile"],"prefix":"10.3390","volume":"18","author":[{"given":"Jin Ho","family":"Sung","sequence":"first","affiliation":[{"name":"Department of Medical Biotechnology, Dongguk University, Seoul 04620, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jong Seob","family":"Jeong","sequence":"additional","affiliation":[{"name":"Department of Medical Biotechnology, Dongguk University, Seoul 04620, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2018,12,13]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"823","DOI":"10.1109\/TITB.2012.2189408","article-title":"A state-of-the-art review on segmentation algorithms in intravascular ultrasound (IVUS) images","volume":"16","author":"Katouzian","year":"2012","journal-title":"IEEE Trans. Inf. Technol. Biomed."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Katouzian, A., Angelini, E., Lorsakul, A., Sturm, B., and Laine, A.F. (2009, January 3\u20135). Lumen border detection of intravascular ultrasound via denoising of directional wavelet representations. Proceedings of the 5th International Conference on Functional Imaging and Modeling of the Heart (FIMH), Nice, France.","DOI":"10.1007\/978-3-642-01932-6_12"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S0301-5629(99)00096-4","article-title":"Advances in ultrasound biomicroscopy","volume":"26","author":"Foster","year":"2000","journal-title":"Ultrasound Med. Biol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"2281","DOI":"10.1109\/TUFFC.2011.2085","article-title":"80-MHz intravascular ultrasound transducer using PMN-PT free-standing film","volume":"58","author":"Li","year":"2011","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_5","first-page":"567","article-title":"Correlation between high frequency intravascular ultrasound and histomorphology in human coronary arteries","volume":"85","author":"Prati","year":"2001","journal-title":"Heart"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1016\/j.jcmg.2014.10.015","article-title":"Accuracy of OCT, grayscale IVUS, and their combination for the diagnosis of coronary TCFA: An ex vivo validation study","volume":"8","author":"Fujii","year":"2015","journal-title":"JACC Cardiovasc. Imaging"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1109\/TUFFC.2014.006679","article-title":"Multi-frequency intravascular ultrasound (IVUS) imaging","volume":"62","author":"Ma","year":"2015","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"3411","DOI":"10.1088\/0031-9155\/60\/9\/3441","article-title":"Design factors of intravascular dual frequency transducers for super-harmonic contrast imaging and acoustic angiography","volume":"60","author":"Ma","year":"2015","journal-title":"Phys. Med. Biol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.ultras.2014.10.011","article-title":"A novel dual-frequency imaging method for intravascular ultrasound applications","volume":"57","author":"Qiu","year":"2015","journal-title":"Ultrasonics"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1088\/0967-3334\/17\/4\/003","article-title":"Measurement of resolution in intravascular ultrasound images","volume":"17","author":"Elliott","year":"1996","journal-title":"Physiol. Meas."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1136\/hrt.77.5.397","article-title":"Assessing atherosclerotic plaque morphology: Comparison of optical coherence tomography and high frequency intravascular ultrasound","volume":"77","author":"Brezinski","year":"1997","journal-title":"Heart"},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Yuan, J., Rhee, S., and Jiang, X.N. (2008, January 2\u20135). 60 MHz PMN-PT based 1-3 composite transducer for IVUS imaging. Proceedings of the 2008 IEEE Ultrasonics Symposium, Beijing, China.","DOI":"10.1109\/ULTSYM.2008.0164"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"2418","DOI":"10.1109\/TUFFC.2005.1563286","article-title":"Transducer for harmonic intravascular ultrasound imaging","volume":"52","author":"Vos","year":"2005","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1548","DOI":"10.1109\/TUFFC.2003.1251138","article-title":"Design of efficient, broadband single-element (20\u201380 MHz) ultrasonic transducers for medical imaging applications","volume":"50","author":"Cannata","year":"2003","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1109\/TUFFC.2008.670","article-title":"Chirp-coded excitation imaging with a high-frequency ultrasound annular array","volume":"55","author":"Mamou","year":"2008","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1038\/srep28360","article-title":"Ultrahigh frequency (100 MHz\u2013300 MHz) ultrasonic transducers for optical resolution medical imaging","volume":"6","author":"Fei","year":"2016","journal-title":"Sci. Rep."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1198","DOI":"10.1016\/j.ultrasmedbio.2008.12.017","article-title":"High-frequency chirp ultrasound imaging with an annular array for ophthalmologic and small-animal imaging","volume":"35","author":"Mamou","year":"2009","journal-title":"Ultrasound Med. Biol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1272","DOI":"10.1109\/TUFFC.2013.2692","article-title":"Lead-free intravascular ultrasound transducer using BZT-50BCT ceramics","volume":"60","author":"Yan","year":"2013","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1016\/j.sna.2015.02.037","article-title":"Angled-focused 45 MHz PMN-PT single emenet transducer for intravascular ultrasound imaging","volume":"228","author":"Yoon","year":"2015","journal-title":"Sens. Actuators A"},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Thomas, L.J., Gilmore, R.S., and Trzaskos, C.R. (1990). High Frequency Focused Ultrasonic Transducer for Invasive Tissue Characterization. (4911170), U.S. Patent.","DOI":"10.1121\/1.399608"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2017\/9327270","article-title":"A high frequency geometric focusing transducer based on 1\u20133 piezocomposite for intravascular ultrasound imaging","volume":"2017","author":"Jian","year":"2017","journal-title":"BioMed Res. Int."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Kern, M.J., Sorajja, P., and Lim, M.J. (2018). Intravascular Lesion Assessment: Physiology and Imaging. Interventional Cardiac Catheterization Handbook, ELSEVIER. [4th ed.].","DOI":"10.1016\/B978-0-323-47671-3.00004-1"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1177\/0161734612469511","article-title":"Delineation of atherosclerotic plaque using subharmonic imaging filtering techniques and a commercial intravascular ultrasound system","volume":"35","author":"Sridharan","year":"2013","journal-title":"Ultrason. Imaging"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/12\/4414\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T15:33:48Z","timestamp":1760196828000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/12\/4414"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,12,13]]},"references-count":23,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2018,12]]}},"alternative-id":["s18124414"],"URL":"https:\/\/doi.org\/10.3390\/s18124414","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,12,13]]}}}