{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,28]],"date-time":"2025-12-28T17:04:09Z","timestamp":1766941449829,"version":"build-2065373602"},"reference-count":29,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2018,12,15]],"date-time":"2018-12-15T00:00:00Z","timestamp":1544832000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>In human motion science, accelerometers are used as linear distance sensors by attaching them to moving body parts, with their measurement axes its measurement axis aligned in the direction of motion. When double integrating the raw sensor data, multiple error sources are also integrated integrated as well, producing inaccuracies in the final position estimation which increases fast with the integration time. In this paper, we make a systematic and experimental comparison of different methods for position estimation, with different sensors and in different motion conditions. The objective is to correlate practical factors that appear in real applications, such as motion mean velocity, path length, calibration method, or accelerometer noise level, with the quality of the estimation. The results confirm that it is possible to use accelerometers to estimate short linear displacements of the body with a typical error of around 4.5% in the general conditions tested in this study. However, they also show that the motion kinematic conditions can be a key factor in the performance of this estimation, as the dynamic response of the accelerometer can affect the final results. The study lays out the basis for a better design of distance estimations, which are useful in a wide range of ambulatory human motion monitoring applications.<\/jats:p>","DOI":"10.3390\/s18124441","type":"journal-article","created":{"date-parts":[[2018,12,18]],"date-time":"2018-12-18T02:15:59Z","timestamp":1545099359000},"page":"4441","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Accelerometry-Based Distance Estimation for Ambulatory Human Motion Analysis"],"prefix":"10.3390","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8910-4855","authenticated-orcid":false,"given":"Juan Carlos","family":"Alvarez","sequence":"first","affiliation":[{"name":"Multisensor Systems and Robotics Group (SiMuR), Department of Electrical, Electronic, Computer and Systems Engineering, University of Oviedo, C\/ Pedro Puig Adam, 33203 Gij\u00f3n, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0395-2712","authenticated-orcid":false,"given":"Diego","family":"\u00c1lvarez","sequence":"additional","affiliation":[{"name":"Multisensor Systems and Robotics Group (SiMuR), Department of Electrical, Electronic, Computer and Systems Engineering, University of Oviedo, C\/ Pedro Puig Adam, 33203 Gij\u00f3n, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5589-6954","authenticated-orcid":false,"given":"Antonio M.","family":"L\u00f3pez","sequence":"additional","affiliation":[{"name":"Multisensor Systems and Robotics Group (SiMuR), Department of Electrical, Electronic, Computer and Systems Engineering, University of Oviedo, C\/ Pedro Puig Adam, 33203 Gij\u00f3n, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2018,12,15]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"729","DOI":"10.1016\/0021-9290(73)90029-8","article-title":"Accelerometry\u2014A technique for the measurement of human body movements","volume":"6","author":"Morris","year":"1973","journal-title":"J. Biomech."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Cavallo, F., Sabatini, A.M., and Genovese, V. (2005, January 2\u20136). A step toward GPS\/INS personal navigation systems: Real-time assessment of gait by foot inertial sensing. Proceedings of the 2005 IEEE\/RSJ International Conference on Intelligent Robots and Systems, Edmonton, AB, Canada.","DOI":"10.1109\/IROS.2005.1544967"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S0966-6362(02)00190-X","article-title":"Assessment of spatio-temporal gait parameters from trunk accelerations during human walking","volume":"18","author":"Zijlstra","year":"2003","journal-title":"Gait Posture"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.gaitpost.2016.09.024","article-title":"Medial-lateral centre of mass displacement and base of support are equally good predictors of metabolic cost in amputee walking","volume":"51","author":"Twiste","year":"2017","journal-title":"Gait Posture"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1007\/s00421-004-1041-5","article-title":"Assessment of spatio-temporal parameters during unconstrained walking","volume":"92","author":"Zijlstra","year":"2004","journal-title":"Eur. J. Appl. Physiol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1016\/j.gaitpost.2005.12.006","article-title":"Accelerometry based assessment of gait parameters in children","volume":"24","author":"Brandes","year":"2006","journal-title":"Gait Posture"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1080\/10255840902896000","article-title":"Ambulatory estimation of mean step length during unconstrained walking by means of COG accelerometry","volume":"12","author":"Gonzalez","year":"2009","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1123\/jab.24.4.360","article-title":"Validity of four gait models to estimate walked distance from vertical COG acceleration","volume":"24","author":"Lopez","year":"2008","journal-title":"J. Appl. Biomech."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1163","DOI":"10.1088\/0957-0233\/13\/8\/301","article-title":"Dependence of inertial measurements of distance on accelerometer noise","volume":"13","author":"Thong","year":"2002","journal-title":"Meas. Sci. Technol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1007\/BF02345966","article-title":"Measuring orientation of human body segments using miniature gyroscopes and accelerometers","volume":"43","author":"Luinge","year":"2005","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_11","unstructured":"IEEE (1998). IEEE Standard Specification Format Guide and Test Procedure for Single-Axis Interferometric Fiber Optic Gyros, IEEE."},{"key":"ref_12","unstructured":"Yuksel, Y., and Kaygisiz, H.B. (2018, November 05). Notes on Stochastic Errors of Low Cost MEMS Inertial Units. Available online: http:\/\/www.instk.org\/web\/static\/bibliography\/Introduction_to_Sensor_Errors.pdf."},{"key":"ref_13","unstructured":"Woodman, O.J. (2007). An Introduction to Inertial Navigation, University of Cambridge."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1109\/TITB.2007.899493","article-title":"Gait analysis using a shoe-integrated wireless sensor system","volume":"12","author":"Bamberg","year":"2008","journal-title":"IEEE Trans. Inf. Technol. Biomed."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1109\/TBME.2004.840727","article-title":"Assessment of walking features from foot inertial sensing","volume":"52","author":"Sabatini","year":"2005","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_16","first-page":"5720","article-title":"Multisensor approach to walking distance estimation with foot inertial sensing","volume":"2007","author":"Alvarez","year":"2007","journal-title":"Conf. Proc. IEEE Eng. Med. Biol. Soc."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1186\/1743-0003-9-9","article-title":"Bilateral step length estimation using a single inertial measurement unit attached to the pelvis","volume":"9","author":"Cereatti","year":"2012","journal-title":"J. NeuroEng. Rehabil."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1016\/j.medengphy.2004.07.005","article-title":"Total body centre of mass displacement estimated using ground reactions during transitory motor tasks: Application to step ascent","volume":"26","author":"Zok","year":"2004","journal-title":"Med. Eng. Phys."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1089","DOI":"10.1109\/TBME.2014.2368211","article-title":"Inertial Sensor-Based Stride Parameter Calculation From Gait Sequences in Geriatric Patients","volume":"62","author":"Rampp","year":"2015","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_20","unstructured":"ABB (2013). Product Manual IRB 120, ABB."},{"key":"ref_21","unstructured":"Whittle, M.W. (2014). Gait Analysis: An Introduction, Butterworth-Heinemann."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.gaitpost.2007.10.010","article-title":"Accelerometry: A technique for quantifying movement patterns during walking","volume":"28","author":"Kavanagh","year":"2008","journal-title":"Gait Posture"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1016\/j.humov.2003.11.002","article-title":"Comparison of kinematic and kinetic methods for computing the vertical motion of the body center of mass during walking","volume":"22","author":"Gard","year":"2004","journal-title":"Hum. Mov. Sci."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"829","DOI":"10.1682\/JRRD.2003.10.0150","article-title":"The effect of walking speed on center of mass displacement","volume":"41","author":"Orendurff","year":"2004","journal-title":"J. Rehabil. Res. Dev."},{"key":"ref_25","unstructured":"Xsens Technologies, B.V. (2006). MTi-G User Manual and Technical Documentation, Xsens Technologies B.V."},{"key":"ref_26","unstructured":"Analog Devices, Inc. (1999). ADXL202\/ADXL210 Low Cost 62 g\/610 g Dual Axis iMEMS\u00ae Accelerometers with Digital Output Data Sheet (Rev. B), Analog Devices, Inc."},{"key":"ref_27","unstructured":"Realtime Technologies Ltd. (2016). Shimmer IMU User Guide, Realtime Technologies Ltd."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1016\/j.sna.2017.08.049","article-title":"Online auto-calibration of triaxial accelerometer with time-variant model structures","volume":"266","author":"Ye","year":"2017","journal-title":"Sens. Actuators A Phys."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/j.measurement.2004.04.005","article-title":"Numerical double integration of acceleration measurements in noise","volume":"36","author":"Thong","year":"2004","journal-title":"Measurement"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/12\/4441\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T15:34:14Z","timestamp":1760196854000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/12\/4441"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,12,15]]},"references-count":29,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2018,12]]}},"alternative-id":["s18124441"],"URL":"https:\/\/doi.org\/10.3390\/s18124441","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2018,12,15]]}}}