{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,8]],"date-time":"2025-11-08T17:48:32Z","timestamp":1762624112035,"version":"build-2065373602"},"reference-count":23,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2018,12,15]],"date-time":"2018-12-15T00:00:00Z","timestamp":1544832000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["Nos.51175084, 51575111 and 51605093"],"award-info":[{"award-number":["Nos.51175084, 51575111 and 51605093"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Tactility is an essential perception for intelligent equipment to acquire external information. It can improve safety and performance during human-machine interactions. Based on the uniqueness theorem of the electrostatic field, a novel flexible film tactile sensor that can detect contact position and be made into any plane shape is proposed in this paper. The tactile sensor included an indium tin oxide (ITO) film, which was uniformly coated on the polyethylene terephthalate (PET) substrate. A specially designed strong conductive line was arranged along the edge of the flexible ITO film, which has weak conductivity. A bias excitation was applied to both ends of the strong conductive line. Through the control of the shape of the strong conductive line, a uniform electric field can be constructed in the whole weak conductive plane. According to the linear relationship between position and potential in the uniform electric field, the coordinate of the contact position can be determined by obtaining the potential of the contact point in the weak conducting plane. The sensor uses a three-layer structure, including an upper conductive layer, an intermediate isolation layer, and a lower conductive layer. A tactile sensor sample was fabricated. The experiment results showed that the principle of the tactile sensor used for the contact position detection is feasible and has certain precision of position detection. The sensor has good flexibility, and can be made into any plane shape, and has only four wires. It is capable of covering large areas of robot arms, and provides safety solutions for most robots.<\/jats:p>","DOI":"10.3390\/s18124445","type":"journal-article","created":{"date-parts":[[2018,12,18]],"date-time":"2018-12-18T02:15:59Z","timestamp":1545099359000},"page":"4445","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["A Flexible Tactile Sensor with Irregular Planar Shape Based on Uniform Electric Field"],"prefix":"10.3390","volume":"18","author":[{"given":"Youzhi","family":"Zhang","sequence":"first","affiliation":[{"name":"School of Mechanical Engineering and Automation, Fuzhou University, Fuzhou 350116, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jinhua","family":"Ye","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering and Automation, Fuzhou University, Fuzhou 350116, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6269-4058","authenticated-orcid":false,"given":"Haomiao","family":"Wang","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering and Automation, Fuzhou University, Fuzhou 350116, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shuheng","family":"Huang","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering and Automation, Fuzhou University, Fuzhou 350116, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haibin","family":"Wu","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering and Automation, Fuzhou University, Fuzhou 350116, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2018,12,15]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"5997","DOI":"10.1002\/adma.201302240","article-title":"25th anniversary article: The evolution of electronic skin (E-Skin): A brief history, design considerations, and recent progress","volume":"25","author":"Mallory","year":"2013","journal-title":"Adv. Mater."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"937","DOI":"10.1038\/nmat4671","article-title":"Pursuing prosthetic electronic skin","volume":"15","author":"Alex","year":"2016","journal-title":"Nat. Mater."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"4121","DOI":"10.1109\/JSEN.2013.2279056","article-title":"Directions toward effective utilization of tactile skin: A review","volume":"13","author":"Ravinder","year":"2013","journal-title":"IEEE Sens. J."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1603","DOI":"10.1126\/science.1182383","article-title":"Materials and mechanics for stretchable electronics","volume":"327","author":"Rogers","year":"2010","journal-title":"Science"},{"key":"ref_5","first-page":"1","article-title":"Research progress and development strategy on tactile sensors for e-skin","volume":"49","author":"Cao","year":"2017","journal-title":"J. Harbin Inst. Technol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/j.sna.2013.03.019","article-title":"Force and slip detection with direct-write compliant tactile sensor using multi-walled carbon nanotube\/polymer composites","volume":"195","author":"Morteza","year":"2013","journal-title":"Sens. Actuators A Phys."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"95008","DOI":"10.1088\/0964-1726\/23\/9\/095008","article-title":"Detection of the position, direction and speed of sliding contact with a multi-layer compliant tactile sensor fabricated using direct-print technology","volume":"23","author":"Morteza","year":"2014","journal-title":"Smart Mater. Struct."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"10211","DOI":"10.3390\/s101110211","article-title":"A polymer-based capacitive sensing array for normal and shear force measurement","volume":"10","author":"Chen","year":"2010","journal-title":"Sensors"},{"key":"ref_9","first-page":"2287","article-title":"Elastomeric electronic skin for prosthetic tactile sensation","volume":"25","author":"Aaron","year":"2015","journal-title":"Adv. Mater."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1739","DOI":"10.1109\/TIM.2013.2293812","article-title":"A novel texture sensor for fabric texture measurement and classification","volume":"63","author":"Song","year":"2014","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"3146","DOI":"10.1109\/JSEN.2014.2368989","article-title":"Flexible tactile sensors using screen-printed P(VDF-TrFE) and MWCNT\/PDMS composites","volume":"15","author":"Saleem","year":"2015","journal-title":"IEEE Sens. J."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"7888","DOI":"10.1002\/adma.201504015","article-title":"Magnetic nanocomposite cilia tactile sensor","volume":"27","author":"Ahmed","year":"2015","journal-title":"Adv. Mater."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1109\/JSEN.2011.2113394","article-title":"Discretely loaded beam-type optical fiber tactile sensor for tissue manipulation and palpation in minimally invasive robotic surgery","volume":"12","author":"Roozbeh","year":"2012","journal-title":"IEEE Sens. J."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"14950","DOI":"10.1038\/ncomms14950","article-title":"Integrated arrays of air-dielectric graphene transistors as transparent active-matrix pressure sensors for wide pressure ranges","volume":"8","author":"Sung","year":"2017","journal-title":"Nat. Commun."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"823","DOI":"10.1007\/s10544-008-9197-0","article-title":"A micro-tactile sensor for in situ tissue characterization in minimally invasive surgery","volume":"10","author":"Mohammad","year":"2008","journal-title":"Biomed. Microdevices"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1109\/JMEMS.2008.2008559","article-title":"PVDF-based microfabricated tactile sensor for minimally invasive surgery","volume":"18","author":"Mohammad","year":"2009","journal-title":"J. Microelectromec. Syst."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1109\/TMECH.2014.2321680","article-title":"Artificial tactile sensing of position and slip speed by exploiting geometrical features","volume":"20","author":"Dana","year":"2015","journal-title":"IEEE\/ASME Trans. Mechatron."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1108\/01439910510629217","article-title":"Flexible full-body tactile sensor of low cost and minimal output connections for service robot","volume":"32","author":"Pan","year":"2005","journal-title":"Ind. Robot"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1016\/j.sna.2016.02.045","article-title":"New tactile sensor for position detection based on distributed planar electric field","volume":"242","author":"Wu","year":"2016","journal-title":"Sens. Actuators A Phys."},{"key":"ref_20","unstructured":"Vincent, D., Nicolas, L., Mathieu, B., Marc, A., and Clement, G. (2009, January 12\u201317). A flexible robot skin for physical human robot interaction. Proceedings of the IEEE International Conference on Robotics and Automation, Kobe, Japan."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Wu, H., Wang, H., Huang, J., Zhang, Y., and Ye, J. (2018). A flexible annular sectorial sensor for detecting contact position based on constant electric field. Micromachines, 9.","DOI":"10.3390\/mi9060309"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Francesco, V., Paolo, F., and Kenji, S. (2016). A deformable smart skin for continuous sensing based on electrical impedance tomography. Sensors, 16.","DOI":"10.3390\/s16111928"},{"key":"ref_23","unstructured":"Yang, Z., Gierad, L., and Chris, H. (2017, January 6\u201311). Electrick: Low-cost touch sensing using electric field tomography. Proceedings of the CHI Conference on Human Factors in Computing Systems, Denver, CO, USA."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/12\/4445\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T15:34:16Z","timestamp":1760196856000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/12\/4445"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,12,15]]},"references-count":23,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2018,12]]}},"alternative-id":["s18124445"],"URL":"https:\/\/doi.org\/10.3390\/s18124445","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2018,12,15]]}}}