{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T02:19:31Z","timestamp":1793240371947,"version":"4.5.0"},"reference-count":56,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2018,12,22]],"date-time":"2018-12-22T00:00:00Z","timestamp":1545436800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100002347","name":"Bundesministerium f\u00fcr Bildung und Forschung","doi-asserted-by":"publisher","award":["16SV7115"],"award-info":[{"award-number":["16SV7115"]}],"id":[{"id":"10.13039\/501100002347","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100002347","name":"Bundesministerium f\u00fcr Bildung und Forschung","doi-asserted-by":"publisher","award":["03IHS075B"],"award-info":[{"award-number":["03IHS075B"]}],"id":[{"id":"10.13039\/501100002347","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The aim of this study was to assess the validity and test-retest reliability of an inertial measurement unit (IMU) system for gait analysis. Twenty-four healthy subjects conducted a 6-min walking test and were instrumented with seven IMUs and retroreflective markers. A kinematic approach was used to estimate the initial and terminal contact events in real-time. Based on these events twelve spatio-temporal parameters (STP) were calculated. A marker based optical motion capture (OMC) system provided the reference. Event-detection rate was about 99%. Detection offset was below 0.017 s. Relative root mean square error (RMSE) ranged from 0.90% to 4.40% for most parameters. However, the parameters that require spatial information of both feet showed higher errors. Step length showed a relative RMSE of 6.69%. Step width and swing width revealed the highest relative RMSE (34.34% and 35.20%). Test-retest results ranged from 0.67 to 0.92, except for the step width (0.25). Summarizing, it appears that the parameters describing the lateral distance between the feet need further improvement. However, the results of the validity and reliability of the IMU system encourage its validation in clinical settings as well as further research.<\/jats:p>","DOI":"10.3390\/s19010038","type":"journal-article","created":{"date-parts":[[2018,12,24]],"date-time":"2018-12-24T10:37:49Z","timestamp":1545647869000},"page":"38","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":109,"title":["Towards Inertial Sensor Based Mobile Gait Analysis: Event-Detection and Spatio-Temporal Parameters"],"prefix":"10.3390","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6908-401X","authenticated-orcid":false,"given":"Wolfgang","family":"Teufl","sequence":"first","affiliation":[{"name":"Junior Research Group wearHEALTH, Technische Universit\u00e4t Kaiserslautern, Gottlieb-Daimler-Str. 48, 67663 Kaiserslautern, Germany"},{"name":"Department of Sports Science, Technische Universit\u00e4t Kaiserslautern, Erwin-Schr\u00f6dinger-Str. 57, 67663 Kaiserslautern, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Lorenz","sequence":"additional","affiliation":[{"name":"Junior Research Group wearHEALTH, Technische Universit\u00e4t Kaiserslautern, Gottlieb-Daimler-Str. 48, 67663 Kaiserslautern, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Markus","family":"Miezal","sequence":"additional","affiliation":[{"name":"Junior Research Group wearHEALTH, Technische Universit\u00e4t Kaiserslautern, Gottlieb-Daimler-Str. 48, 67663 Kaiserslautern, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bertram","family":"Taetz","sequence":"additional","affiliation":[{"name":"Junior Research Group wearHEALTH, Technische Universit\u00e4t Kaiserslautern, Gottlieb-Daimler-Str. 48, 67663 Kaiserslautern, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1982-6374","authenticated-orcid":false,"given":"Michael","family":"Fr\u00f6hlich","sequence":"additional","affiliation":[{"name":"Department of Sports Science, Technische Universit\u00e4t Kaiserslautern, Erwin-Schr\u00f6dinger-Str. 57, 67663 Kaiserslautern, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7283-8166","authenticated-orcid":false,"given":"Gabriele","family":"Bleser","sequence":"additional","affiliation":[{"name":"Junior Research Group wearHEALTH, Technische Universit\u00e4t Kaiserslautern, Gottlieb-Daimler-Str. 48, 67663 Kaiserslautern, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2018,12,22]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"2195","DOI":"10.1016\/j.spinee.2018.04.016","article-title":"Decompression surgery improves gait quality in patients with symptomatic lumbar spinal stenosis","volume":"18","author":"Loske","year":"2018","journal-title":"Spine J."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1177\/1120700018760262","article-title":"A randomised trial comparing spatio-temporal gait parameters after total hip arthroplasty between the direct anterior and direct lateral surgical approaches","volume":"28","author":"Zomar","year":"2018","journal-title":"HIP Int."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"955","DOI":"10.1093\/rheumatology\/39.9.955","article-title":"Range of joint motion and disability in patients with osteoarthritis of the knee or hip","volume":"39","author":"Steultjens","year":"2000","journal-title":"Rheumatology"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1186\/s12938-018-0488-2","article-title":"Estimation of spatio-temporal parameters of gait from magneto-inertial measurement units: Multicenter validation among Parkinson, mildly cognitively impaired and healthy older adults","volume":"17","author":"Bertoli","year":"2018","journal-title":"Biomed. Eng. OnLine"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"7729","DOI":"10.4081\/ni.2018.7729","article-title":"Quantitative assessment of gait parameters in people with Parkinson\u2019s disease in laboratory and clinical setting: Are the measures interchangeable?","volume":"10","author":"Pau","year":"2018","journal-title":"Neurol. Int."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Leijendekkers, R.A., Marra, M.A., Kolk, S., van Bon, G., Schreurs, B.W., Weerdesteyn, V., and Verdonschot, N. (2018). Gait symmetry and hip strength in women with developmental dysplasia following hip arthroplasty compared to healthy subjects: A cross-sectional study. PLoS ONE, 13.","DOI":"10.1371\/journal.pone.0193487"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1016\/j.gaitpost.2016.11.005","article-title":"Asymmetry between lower limbs during rested and fatigued state running gait in healthy individuals","volume":"51","author":"Radzak","year":"2017","journal-title":"Gait Posture"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1016\/j.gaitpost.2016.11.008","article-title":"25 years of lower limb joint kinematics by using inertial and magnetic sensors: A review of methodological approaches","volume":"51","author":"Picerno","year":"2017","journal-title":"Gait Posture"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Camomilla, V., Bergamini, E., Fantozzi, S., Vannozzi, G., Camomilla, V., Bergamini, E., Fantozzi, S., and Vannozzi, G. (2018). Trends Supporting the In-Field Use of Wearable Inertial Sensors for Sport Performance Evaluation: A Systematic Review. Sensors, 18.","DOI":"10.3390\/s18030873"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Kianifar, R., Lee, A., Raina, S., and Kulic, D. (2016, January 16\u201320). Classification of Squat Quality with Inertial Measurement Units in the Single Leg Squat Mobility Test. Proceedings of the 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Orlando, FL, USA.","DOI":"10.1109\/EMBC.2016.7592162"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1007\/s11517-016-1537-2","article-title":"Validation of inertial measurement units with an optoelectronic system for whole-body motion analysis","volume":"55","author":"Mecheri","year":"2017","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Al-Amri, M., Nicholas, K., Button, K., Sparkes, V., Sheeran, L., and Davies, J.L. (2018). Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity. Sensors, 18.","DOI":"10.3390\/s18030719"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1521","DOI":"10.1109\/JBHI.2016.2608720","article-title":"Toward Pervasive Gait Analysis With Wearable Sensors: A Systematic Review","volume":"20","author":"Chen","year":"2016","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1016\/j.gaitpost.2017.06.019","article-title":"A systematic review of gait analysis methods based on inertial sensors and adaptive algorithms","volume":"57","author":"Caldas","year":"2017","journal-title":"Gait Posture"},{"key":"ref_15","first-page":"S795","article-title":"Online Gait Phase Detection with Automatic Adaption to Gait Velocity Changes Using Accelerometers and Gyroscopes","volume":"59","author":"Seel","year":"2014","journal-title":"Biomed. Tech."},{"key":"ref_16","unstructured":"M\u00fcller, P., Seel, T., and Schauer, T. (2018, November 26). Experimental Evaluation of a Novel Inertial Sensor Based Realtime Gait Phase Detection Algorithm. Available online: https:\/\/www.control.tu-berlin.de\/wiki\/images\/5\/5e\/Mueller_TAR2015.pdf."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1016\/j.gaitpost.2011.02.023","article-title":"Inertial sensor based reference gait data for healthy subjects","volume":"33","author":"Schwesig","year":"2011","journal-title":"Gait Posture"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Kluge, F., Ga\u00dfner, H., Hannink, J., Pasluosta, C., Klucken, J., and Eskofier, B.M. (2017). Towards Mobile Gait Analysis: Concurrent Validity and Test-Retest Reliability of an Inertial Measurement System for the Assessment of Spatio-Temporal Gait Parameters. Sensors, 17.","DOI":"10.3390\/s17071522"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1186\/1743-0003-9-9","article-title":"Bilateral step length estimation using a single inertial measurement unit attached to the pelvis","volume":"9","author":"Cereatti","year":"2012","journal-title":"J. NeuroEng. Rehabil."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"23230","DOI":"10.3390\/s141223230","article-title":"Drift Removal for Improving the Accuracy of Gait Parameters Using Wearable Sensor Systems","volume":"14","author":"Takeda","year":"2014","journal-title":"Sensors"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Bertuletti, S., Cereatti, A., Comotti, D., Caldara, M., and Della Croce, U. (2017). Static and Dynamic Accuracy of an Innovative Miniaturized Wearable Platform for Short Range Distance Measurements for Human Movement Applications. Sensors, 17.","DOI":"10.3390\/s17071492"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Agostini, V., Gastaldi, L., Rosso, V., Knaflitz, M., and Tadano, S. (2017). A Wearable Magneto-Inertial System for Gait Analysis (H-Gait): Validation on Normal Weight and Overweight\/Obese Young Healthy Adults. Sensors, 17.","DOI":"10.3390\/s17102406"},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Cimolin, V., Capodaglio, P., Cau, N., Galli, M., Santovito, C., Patrizi, A., Tringali, G., and Sartorio, A. (2017). Computation of spatio-temporal parameters in level walking using a single inertial system in lean and obese adolescents. Biomed. Eng. Biomed. Tech., 62.","DOI":"10.1515\/bmt-2015-0180"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/j.jbiomech.2017.03.015","article-title":"Measuring joint kinematics of treadmill walking and running: Comparison between an inertial sensor based system and a camera-based system","volume":"57","author":"Roos","year":"2017","journal-title":"J. Biomech."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1186\/s12984-016-0115-z","article-title":"Validity and reliability of a portable gait analysis system for measuring spatiotemporal gait characteristics: Comparison to an instrumented treadmill","volume":"13","author":"Donath","year":"2016","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1016\/j.gaitpost.2016.07.269","article-title":"Mobile inertial sensor based gait analysis: Validity and reliability of spatiotemporal gait characteristics in healthy seniors","volume":"49","author":"Donath","year":"2016","journal-title":"Gait Posture"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.gaitpost.2014.03.189","article-title":"Quantified self and human movement: A review on the clinical impact of wearable sensing and feedback for gait analysis and intervention","volume":"40","author":"Shull","year":"2014","journal-title":"Gait Posture"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1605","DOI":"10.1016\/j.jbiomech.2011.03.016","article-title":"Training multi-parameter gaits to reduce the knee adduction moment with data-driven models and haptic feedback","volume":"44","author":"Shull","year":"2011","journal-title":"J. Biomech."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"375638","DOI":"10.1155\/2015\/375638","article-title":"A Portable Gait Asymmetry Rehabilitation System for Individuals with Stroke Using a Vibrotactile Feedback","volume":"2015","author":"Afzal","year":"2015","journal-title":"BioMed Res. Int."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1109\/TNSRE.2014.2365548","article-title":"Providing Time-Discrete Gait Information by Wearable Feedback Apparatus for Lower-Limb Amputees: Usability and Functional Validation","volume":"23","author":"Crea","year":"2015","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Seel, T., Laidig, D., Valtin, M., Werner, C., Raisch, J., and Schauer, T. (2014, January 16\u201319). Feedback control of foot eversion in the adaptive peroneal stimulator. Proceedings of the 22nd Mediterranean Conference on Control and Automation, Palermo, Italy.","DOI":"10.1109\/MED.2014.6961585"},{"key":"ref_32","unstructured":"Valtin, M., Seel, T., Raisch, J., and Schauer, T. (2014, January 24\u201329). Iterative learning control of drop foot stimulation with array electrodes for selective muscle activation. Proceedings of the 19th World Congress The International Federation of Automatic Control, Cape Town, South Africa."},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Teufl, W., Miezal, M., Taetz, B., Fr\u00f6hlich, M., and Bleser, G. (2018). Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics. Sensors, 18.","DOI":"10.3390\/s18071980"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1016\/j.gaitpost.2006.12.018","article-title":"A new anatomically based protocol for gait analysis in children","volume":"26","author":"Leardini","year":"2007","journal-title":"Gait Posture"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1016\/j.measurement.2014.03.004","article-title":"Experimental evaluation of accuracy and repeatability of a novel body-to-sensor calibration procedure for inertial sensor-based gait analysis","volume":"52","author":"Palermo","year":"2014","journal-title":"Measurement"},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Miezal, M., Taetz, B., and Bleser, G. (2016). On Inertial Body Tracking in the Presence of Model Calibration Errors. Sensors, 16.","DOI":"10.3390\/s16071132"},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Miezal, M., Taetz, B., and Bleser, G. (3, January 29). Real-time inertial lower body kinematics and ground contact estimation at anatomical foot points for agile human locomotion. Proceedings of the 2017 IEEE International Conference on Robotics and Automation (ICRA), Singapore.","DOI":"10.1109\/ICRA.2017.7989371"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"734","DOI":"10.1016\/j.jbiomech.2014.12.034","article-title":"TLEM 2.0\u2014A comprehensive musculoskeletal geometry dataset for subject-specific modeling of lower extremity","volume":"48","author":"Carbone","year":"2015","journal-title":"J. Biomech."},{"key":"ref_39","unstructured":"Dreyfuss, H. (1967). The Measure of Man: Human Factors in Design, Whitney Library of Design."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"710","DOI":"10.1016\/j.gaitpost.2007.07.007","article-title":"Two simple methods for determining gait events during treadmill and overground walking using kinematic data","volume":"27","author":"Zeni","year":"2008","journal-title":"Gait Posture"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1037\/1082-989X.1.1.30","article-title":"Forming Inferences About Some Intraclass Correlation Coefficients","volume":"1","author":"Mcgraw","year":"1996","journal-title":"Psychol. Methods"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1037\/1040-3590.6.4.284","article-title":"Guidelines, criteria, and rules of thumb for evaluating normed and standardized assessment instruments in psychology","volume":"6","author":"Cicchetti","year":"1994","journal-title":"Psychol. Assess."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/j.gaitpost.2015.03.015","article-title":"Using horizontal heel displacement to identify heel strike instants in normal gait","volume":"42","author":"Banks","year":"2015","journal-title":"Gait Posture"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/j.gaitpost.2016.08.012","article-title":"Gait event-detection in laboratory and real life settings: Accuracy of ankle and waist sensor based methods","volume":"50","author":"Storm","year":"2016","journal-title":"Gait Posture"},{"key":"ref_45","unstructured":"Taetz, B., Bleser, G., and Miezal, M. (2016, January 5\u20138). Towards self-calibrating inertial body motion capture. Proceedings of the Information Fusion (FUSION), In Proceedings of 2016 19th International Conference on Information Fusion (FUSION), Heidelberg, Germany."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"6891","DOI":"10.3390\/s140406891","article-title":"IMU-Based Joint Angle Measurement for Gait Analysis","volume":"14","author":"Seel","year":"2014","journal-title":"Sensors"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1186\/1743-0003-11-152","article-title":"Estimation of step-by-step spatio-temporal parameters of normal and impaired gait using shank-mounted magneto-inertial sensors: Application to elderly, hemiparetic, parkinsonian and choreic gait","volume":"11","author":"Trojaniello","year":"2014","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"702","DOI":"10.1159\/000235905","article-title":"Gait Variability among Healthy Adults: Low and High Stride-to-Stride Variability Are Both a Reflection of Gait Stability","volume":"55","author":"Beauchet","year":"2009","journal-title":"Gerontology"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1136\/jnnp.73.3.310","article-title":"Typical features of cerebellar ataxic gait","volume":"73","author":"Stolze","year":"2002","journal-title":"J. Neurol. Neurosurg. Psychiatry"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"786","DOI":"10.1093\/brain\/awl376","article-title":"Specific influences of cerebellar dysfunctions on gait","volume":"130","author":"Ilg","year":"2007","journal-title":"Brain"},{"key":"ref_51","doi-asserted-by":"crossref","unstructured":"M\u00fcller, B., Ilg, W., Giese, M.A., and Ludolph, N. (2017). Validation of enhanced kinect sensor based motion capturing for gait assessment. PLoS ONE, 12.","DOI":"10.1101\/098863"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1016\/j.gaitpost.2017.03.021","article-title":"The high cost of swing leg circumduction during human walking","volume":"54","author":"Shorter","year":"2017","journal-title":"Gait Posture"},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"S157","DOI":"10.1097\/PHM.0000000000000800","article-title":"Reducing Circumduction and Hip Hiking During Hemiparetic Walking Through Targeted Assistance of the Paretic Limb Using a Soft Robotic Exosuit","volume":"96","author":"Awad","year":"2017","journal-title":"Am. J. Phys. Med. Rehabil."},{"key":"ref_54","doi-asserted-by":"crossref","unstructured":"Shiotani, M., and Watanabe, T. (2014, January 26\u201330). A preliminary study on evaluation of circumduction movement during gait with wireless inertial sensors. Proceedings of the 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Chicago, IL, USA.","DOI":"10.1109\/EMBC.2014.6944953"},{"key":"ref_55","doi-asserted-by":"crossref","unstructured":"Watanabe, T., and Saito, H. (September, January 30). Tests of wireless wearable sensor system in joint angle measurement of lower limbs. Proceedings of the 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Boston, MA, USA.","DOI":"10.1109\/IEMBS.2011.6091395"},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1016\/j.gaitpost.2017.02.029","article-title":"Accuracy and repeatability of single-pose calibration of inertial measurement units for whole-body motion analysis","volume":"54","author":"Mecheri","year":"2017","journal-title":"Gait Posture"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/1\/38\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T15:35:40Z","timestamp":1760196940000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/1\/38"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,12,22]]},"references-count":56,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2019,1]]}},"alternative-id":["s19010038"],"URL":"https:\/\/doi.org\/10.3390\/s19010038","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,12,22]]}}}