{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T22:17:49Z","timestamp":1767651469342,"version":"build-2065373602"},"reference-count":36,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2018,12,22]],"date-time":"2018-12-22T00:00:00Z","timestamp":1545436800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001321","name":"National Research Foundation","doi-asserted-by":"publisher","award":["NRF2016R1A2B4015087"],"award-info":[{"award-number":["NRF2016R1A2B4015087"]}],"id":[{"id":"10.13039\/501100001321","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Force changes in axially loaded members can be monitored by quantifying variations in impedance signatures. However, statistical damage metrics, which are not physically related to the axial load, often lead to difficulties in accurately estimating the amount of axial force changes. Inspired by the wearable technology, this study proposes a novel wearable piezoelectric interface that can be used to monitor and quantitatively estimate the force changes in axial members. Firstly, an impedance-based force estimation method was developed for axially loaded members. The estimation was based on the relationship between the axial force level and the peak frequencies of impedance signatures, which were obtained from the wearable piezoelectric interface. The estimation of the load transfer capability from the axial member to the wearable interface was found to be an important factor for the accurate prediction of axial force. Secondly, a prototype of the wearable piezoelectric interface was designed to be easily fitted into existing axial members. Finally, the feasibility of the proposed technique was established by assessing tension force changes in a numerical model of an axially loaded cylindrical member and a lab-scale model of a prestressed cable structure.<\/jats:p>","DOI":"10.3390\/s19010047","type":"journal-article","created":{"date-parts":[[2018,12,24]],"date-time":"2018-12-24T10:37:49Z","timestamp":1545647869000},"page":"47","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":29,"title":["Tension Force Estimation in Axially Loaded Members Using Wearable Piezoelectric Interface Technique"],"prefix":"10.3390","volume":"19","author":[{"given":"Joo-Young","family":"Ryu","sequence":"first","affiliation":[{"name":"Department of Ocean Engineering, Pukyong National University, Busan 48723, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9231-2129","authenticated-orcid":false,"given":"Thanh-Canh","family":"Huynh","sequence":"additional","affiliation":[{"name":"Department of Ocean Engineering, Pukyong National University, Busan 48723, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jeong-Tae","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Ocean Engineering, Pukyong National University, Busan 48723, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2018,12,22]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Shinke, T., Hironaka, K., Zui, H., and Nishimura, H. (1980). Practical Formulas for Estimation of Cable Tension by Vibration Method. Proceedings of the Japan Society of Civil Engineers, Japan Society of Civil Engineers.","DOI":"10.2208\/jscej1969.1980.294_25"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1061\/(ASCE)0733-9445(1996)122:6(651)","article-title":"Practical Formulas for Estimation of Cable Tension by Vibration Method","volume":"122","author":"Zui","year":"1996","journal-title":"J. Struct. Eng."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1177\/1045389X09350719","article-title":"Development of an Automated Wireless Tension Force Estimation System for Cable-stayed Bridges","volume":"21","author":"Cho","year":"2009","journal-title":"J. Intell. Mater. Syst. Struct."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"025006","DOI":"10.1088\/0964-1726\/23\/2\/025006","article-title":"A wireless smart sensor network for automated monitoring of cable tension","volume":"23","author":"Jian","year":"2014","journal-title":"Smart Mater. Struct."},{"key":"ref_5","first-page":"47","article-title":"Wireless structural health monitoring of stay cables under two consecutive typhoons","volume":"1","author":"Kim","year":"2014","journal-title":"Struct. Monit. Maint."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1077","DOI":"10.1016\/j.optlaseng.2009.04.016","article-title":"Applications of optical fibre Bragg gratings sensing technology-based smart stay cables","volume":"47","author":"Li","year":"2009","journal-title":"Opt. Lasers Eng."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"B4016005","DOI":"10.1061\/(ASCE)AS.1943-5525.0000608","article-title":"FOS-Based Prestress Force Monitoring and Temperature Effect Estimation in Unbonded Tendons of PSC Girders","volume":"30","author":"Huynh","year":"2017","journal-title":"J. Aerosp. Eng."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1060","DOI":"10.3390\/s150101060","article-title":"A sensor-type PC strand with an embedded FBG sensor for monitoring prestress forces","volume":"15","author":"Kim","year":"2015","journal-title":"Sensors"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Kim, J.M., Kim, C.M., Choi, S.Y., and Lee, B.Y. (2017). Enhanced Strain Measurement Range of an FBG Sensor Embedded in Seven-Wire Steel Strands. Sensors, 17.","DOI":"10.3390\/s17071654"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1177\/05831024030356001","article-title":"Overview of piezoelectric impedance-based health monitoring and path forward","volume":"35","author":"Park","year":"2003","journal-title":"Shock Vib. Dig."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"035008","DOI":"10.1088\/0964-1726\/17\/3\/035008","article-title":"Practical issues related to the application of the electromechanical impedance technique in the structural health monitoring of civil structures: I. Experiment","volume":"17","author":"Yang","year":"2008","journal-title":"Smart Mater. Struct."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Huynh, T.C., Dang, N.L., and Kim, J.T. (2018). Preload Monitoring in Bolted Connection Using Piezoelectric-Based Smart Interface. Sensors, 18.","DOI":"10.20944\/preprints201808.0336.v1"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"385","DOI":"10.12989\/was.2017.24.4.385","article-title":"Hybrid bolt-loosening detection in wind turbine tower structures by vibration and impedance responses","volume":"24","author":"Nguyen","year":"2017","journal-title":"Wind Struct."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"957","DOI":"10.1088\/0964-1726\/15\/4\/009","article-title":"PZT-based active damage detection techniques for steel bridge components","volume":"15","author":"Park","year":"2006","journal-title":"Smart Mater. Struct."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1016\/j.engstruct.2012.01.012","article-title":"Impedance-based structural health monitoring incorporating neural network technique for identification of damage type and severity","volume":"39","author":"Min","year":"2012","journal-title":"Eng. Struct."},{"key":"ref_16","first-page":"301","article-title":"Advances and challenges in impedance-based structural health monitoring","volume":"4","author":"Huynh","year":"2017","journal-title":"Struct. Monit. Maint."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"045003","DOI":"10.1088\/0964-1726\/18\/4\/045003","article-title":"Monitoring damage propagation using PZT impedance transducers","volume":"18","author":"Yang","year":"2009","journal-title":"Smart Mater. Struct."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Annamdas, V.G.M., Radhika, M.A., and Yang, Y. (2009, January 8\u201312). Easy installation method of piezoelectric (PZT) transducers for health monitoring of structures using electro-mechanical impedance technique. Proceedings of the 16th International Symposium on: Smart Structures and Materials & Nondestructive Evaluation and Health Monitoring, San Diego, CA, USA.","DOI":"10.1117\/12.815409"},{"key":"ref_19","first-page":"237","article-title":"Experimental investigation of magnetic-mount PZT-interface for impedance-based damage detection in steel girder connection","volume":"4","author":"Ryu","year":"2017","journal-title":"Struct. Monit. Maint."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"902","DOI":"10.1177\/1475921717725028","article-title":"A novel electromechanical impedance-based model for strength development monitoring of cementitious materials","volume":"17","author":"Lu","year":"2017","journal-title":"Struct. Health Monit."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1155\/2014\/784731","article-title":"Impedance-Based Cable Force Monitoring in Tendon-Anchorage Using Portable PZT-Interface Technique","volume":"2014","author":"Huynh","year":"2014","journal-title":"Math. Probl. Eng."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Wang, C., Wang, N., Ho, S.-C., Chen, X., Pan, M., and Song, G. (2018). Design of a Novel Wearable Sensor Device for Real-Time Bolted Joints Health Monitoring. IEEE Internet Things J.","DOI":"10.1109\/JIOT.2018.2852653"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"107","DOI":"10.12989\/sss.2016.17.1.107","article-title":"An electromechanical impedance-based method for tensile force estimation and damage diagnosis of post-tensioning systems","volume":"17","author":"Min","year":"2016","journal-title":"Smart Struct. Syst."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"81","DOI":"10.12989\/sss.2009.5.1.081","article-title":"Vibration and impedance monitoring for prestress-loss prediction in PSC girder bridges","volume":"5","author":"Kim","year":"2009","journal-title":"Smart Struct. Syst."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"e2173","DOI":"10.1002\/stc.2173","article-title":"RBFN-based temperature compensation method for impedance monitoring in prestressed tendon anchorage","volume":"25","author":"Huynh","year":"2018","journal-title":"Struct. Control Health Monit."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"105011","DOI":"10.1088\/0964-1726\/25\/10\/105011","article-title":"Load monitoring of pin-connected structures using piezoelectric impedance measurement","volume":"25","author":"Liang","year":"2016","journal-title":"Smart Mater. Struct."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Wang, B., Huo, L., Chen, D., Li, W., and Song, G. (2017). Impedance-Based Pre-Stress Monitoring of Rock Bolts Using a Piezoceramic-Based Smart Washer\u2014A Feasibility Study. Sensors, 17.","DOI":"10.3390\/s17020250"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1088\/0964-1726\/13\/1\/003","article-title":"Quantitative health monitoring of bolted joints using a piezoceramic actuator-sensor","volume":"13","author":"Ritdumrongkul","year":"2004","journal-title":"Smart Mater. Struct."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1016\/j.conbuildmat.2018.03.222","article-title":"Investigating the performance of \u201cSmart Probe\u201d based indirect EMI technique for strength development monitoring of cementitious materials\u2014Modeling and parametric study","volume":"172","author":"Lu","year":"2018","journal-title":"Constr. Build. Mater."},{"key":"ref_30","first-page":"181","article-title":"Quantitative damage identification in tendon anchorage via PZT interface-based impedance monitoring technique","volume":"20","author":"Huynh","year":"2017","journal-title":"Smart Struct. Syst."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1177\/1045389X9400500102","article-title":"Coupled Electro-Mechanical Analysis of Adaptive Material Systems\u2014Determination of the Actuator Power Consumption and System Energy Transfer","volume":"5","author":"Liang","year":"1994","journal-title":"J. Intell. Mater. Syst. Struct."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"375","DOI":"10.12989\/sss.2015.15.2.375","article-title":"Local dynamic characteristics of PZT impedance interface on tendon anchorage under prestress force variation","volume":"15","author":"Huynh","year":"2015","journal-title":"Smart Struct. Syst."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1177\/1045389X12437888","article-title":"Effect of varying axial load under fixed boundary condition on admittance signatures of electromechanical impedance technique","volume":"23","author":"Lim","year":"2012","journal-title":"J. Intell. Mater. Syst. Struct."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"055010","DOI":"10.1088\/1361-665X\/aa64c0","article-title":"Time-frequency analysis of electro-mechanical impedance (EMI) signature for physics-based damage detections using piezoelectric wafer active sensor (PWAS)","volume":"26","author":"Zahedi","year":"2017","journal-title":"Smart Mater. Struct."},{"key":"ref_35","unstructured":"Clough, R., and Penzien, J. (1995). Dynamics of Structures, Computers & Structures, Inc."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"125037","DOI":"10.1088\/0964-1726\/23\/12\/125037","article-title":"Understanding the effects of adhesive layer on the electromechanical impedance (EMI) of bonded piezoelectric wafer transducer","volume":"23","author":"Islam","year":"2014","journal-title":"Smart Mater. Struct."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/1\/47\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T15:35:45Z","timestamp":1760196945000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/1\/47"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,12,22]]},"references-count":36,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2019,1]]}},"alternative-id":["s19010047"],"URL":"https:\/\/doi.org\/10.3390\/s19010047","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2018,12,22]]}}}