{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T17:05:13Z","timestamp":1793207113311,"version":"4.5.0"},"reference-count":25,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2019,2,7]],"date-time":"2019-02-07T00:00:00Z","timestamp":1549497600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Long-term heart rate (HR) monitoring by wrist-worn photoplethysmograph (PPG) sensors enables the assessment of health conditions during daily life with high user comfort. However, PPG signals are vulnerable to motion artifacts (MAs), which significantly affect the accuracy of estimated physiological parameters such as HR. This paper proposes a novel modular algorithm framework for MA removal based on different wavelengths for wrist-worn PPG sensors. The framework uses a green PPG signal for HR monitoring and an infrared PPG signal as the motion reference. The proposed framework includes four main steps: motion detection, motion removal using continuous wavelet transform, approximate HR estimation and signal reconstruction. The proposed algorithm is evaluated against an electrocardiogram (ECG) in terms of HR error for a dataset of 6 healthy subjects performing 21 types of motion. The proposed MA removal method reduced the average error in HR estimation from 4.3, 3.0 and 3.8 bpm to 0.6, 1.0 and 2.1 bpm in periodic, random, and continuous non-periodic motion situations, respectively.<\/jats:p>","DOI":"10.3390\/s19030673","type":"journal-article","created":{"date-parts":[[2019,2,7]],"date-time":"2019-02-07T11:50:33Z","timestamp":1549540233000},"page":"673","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":133,"title":["Motion Artifact Reduction for Wrist-Worn Photoplethysmograph Sensors Based on Different Wavelengths"],"prefix":"10.3390","volume":"19","author":[{"given":"Yifan","family":"Zhang","sequence":"first","affiliation":[{"name":"Holst Centre\/imec, 5656AE Eindhoven, The Netherlands"},{"name":"Department of Electrical Engineering, Eindhoven University of Technology, 5600MB Eindhoven, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuang","family":"Song","sequence":"additional","affiliation":[{"name":"imec vzw, 3001 Leuven, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rik","family":"Vullings","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, Eindhoven University of Technology, 5600MB Eindhoven, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dwaipayan","family":"Biswas","sequence":"additional","affiliation":[{"name":"imec vzw, 3001 Leuven, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Neide","family":"Sim\u00f5es-Capela","sequence":"additional","affiliation":[{"name":"imec vzw, 3001 Leuven, Belgium"},{"name":"Department of Electrical Engineering, KU Leuven, 3001 Leuven, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7511-1923","authenticated-orcid":false,"given":"Nick","family":"van Helleputte","sequence":"additional","affiliation":[{"name":"imec vzw, 3001 Leuven, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chris","family":"van Hoof","sequence":"additional","affiliation":[{"name":"imec vzw, 3001 Leuven, Belgium"},{"name":"Department of Electrical Engineering, KU Leuven, 3001 Leuven, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Willemijn","family":"Groenendaal","sequence":"additional","affiliation":[{"name":"Holst Centre\/imec, 5656AE Eindhoven, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2019,2,7]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1109\/TBME.2015.2476337","article-title":"Photoplethysmography revisited: from contact to noncontact, from point to imaging","volume":"63","author":"Sun","year":"2016","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"522","DOI":"10.1109\/TBME.2014.2359372","article-title":"TROIKA: A general framework for heart rate monitoring using wrist-type photoplethysmographic signals during intensive physical exercise","volume":"62","author":"Zhang","year":"2015","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1902","DOI":"10.1109\/TBME.2015.2406332","article-title":"Photoplethysmography-based heart rate monitoring in physical activities via joint sparse spectrum reconstruction","volume":"62","author":"Zhang","year":"2015","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Tautan, A.M., Young, A., Wentink, E., and Wieringa, F. (2015, January 25\u201329). Characterization and reduction of motion artifacts in photoplethysmographic signals from a wrist-worn device. Proceedings of the 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Milan, Italy.","DOI":"10.1109\/EMBC.2015.7319795"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1016\/j.icte.2016.11.003","article-title":"Gyroscope vs. accelerometer measurements of motion from wrist PPG during physical exercise","volume":"24","author":"Casson","year":"2016","journal-title":"ICT Express"},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Jarchi, D., and Casson, A.J. (2016). Description of a database containing wrist PPG signals recorded during physical exercise with both accelerometer and gyroscope measures of motion. Data, 2.","DOI":"10.3390\/data2010001"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1166","DOI":"10.1109\/JSEN.2018.2879970","article-title":"Motion Artifact Cancellation in Wearable Photoplethysmography Using Gyroscope","volume":"19","author":"Lee","year":"2019","journal-title":"IEEE Sens. J."},{"key":"ref_8","unstructured":"Geun, E., Heo, H., Nam, K.C., and Huh, Y. (2008, January 6\u20139). Measurement site and applied pressure consideration in wrist photoplethysmography. Proceedings of the 23rd International Technical Conference on Circuits\/Systems, Computers and Communications (ITC-CSCC 2008), Shimonoseki, Japan."},{"key":"ref_9","first-page":"587","article-title":"Wearable photoplethysmographic sensor based on different LED light intensities","volume":"17","author":"Lee","year":"2017","journal-title":"IEEE Sens. J."},{"key":"ref_10","unstructured":"Renevey, P., Vetter, R., Krauss, J., Celka, P., and Depeursinge, Y. (2001, January 25\u201328). Wrist-located pulse detection using IR signals, activity and nonlinear artifact cancellation. Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Istanbul, Turkey."},{"key":"ref_11","unstructured":"Vizbara, V. (2016, January 24\u201325). Comparison of green, blue and infrared light in wrist and forehead photoplethysmography. Proceedings of the 20th International Conference of Biomedical Engineering, Kaunas, Lithuania."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Matsumura, K., Rolfe, P., Lee, J., and Yamakoshi, T. (2014). iPhone 4s photoplethysmography: Which light color yields the most accurate heart rate and normalized pulse volume using the iphysiometer application in the presence of motion artifact?. PLoS ONE, 9.","DOI":"10.1371\/journal.pone.0091205"},{"key":"ref_13","unstructured":"(2017, March 17). OSRAM Opto Semiconductors, SFH 7060 Datasheet. Available online: www.osram-os.com."},{"key":"ref_14","unstructured":"Lee, C.M., and Zhang, Y.T. (2003, January 20\u201322). Reduction of motion artifacts from photoplethysmographic recordings using a wavelet denoising approach. Proceedings of the IEEE EMBS Asian-Pacific Conference on Biomedical Engineering, Kyoto, Japan."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"670","DOI":"10.1109\/JBHI.2013.2264358","article-title":"A Motion-Tolerant Adaptive Algorithm for Wearable Photoplethysmographic Biosensors","volume":"18","author":"Yousefi","year":"2014","journal-title":"IEEE J. Biomed. Health Inf."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1088\/1361-6579\/aa506e","article-title":"Robust heart rate estimation using wrist-type photoplethysmographic signals during physical exercise: An approach based on adaptive filtering","volume":"38","author":"Fallet","year":"2017","journal-title":"Physiol. Meas."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1109\/JBHI.2016.2632201","article-title":"Real-Time Robust Heart Rate Estimation From Wrist-Type PPG Signals Using Multiple Reference Adaptive Noise Cancellation","volume":"22","author":"Chowdhury","year":"2016","journal-title":"IEEE J. Biomed. Health Inf."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1109\/TBCAS.2007.910900","article-title":"Multichannel reflective PPG earpiece sensor with passive motion cancellation","volume":"1","author":"Wang","year":"2007","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"2983","DOI":"10.1109\/JSEN.2018.2801385","article-title":"Wearable Multichannel Photoplethysmography Framework for Heart Rate Monitoring During Intensive Exercise","volume":"18","author":"Lee","year":"2018","journal-title":"IEEE Sens. J."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Ye, Y., He, W., Cheng, Y., Huang, W., and Zhang, Z. (2017). A Robust Random Forest-Based Approach for Heart Rate Monitoring Using Photoplethysmography Signal Contaminated by Intense Motion Artifacts. Sensors, 17.","DOI":"10.3390\/s17020385"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1445","DOI":"10.1109\/TIM.2011.2175832","article-title":"A novel approach for motion artifact reduction in PPG signals based on AS-LMS adaptive filter","volume":"61","author":"Ram","year":"2012","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_22","unstructured":"Wijshoff, R. (2016). On photoplethysmography artifact reduction and applications. [PhD. Thesis, Technische Universiteit Eindhoven]."},{"key":"ref_23","unstructured":"Salehizadeh, S.M.A. (2015). Motion and Noise Artifact Detection and Vital Signal Reconstruction in ECG\/PPG based Wearable Devices. [Ph.D. Thesis, University of Connecticut]."},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Temko, A. (2015, January 25\u201329). Estimation of heart rate from photoplethysmography during physical exercise using wiener filtering and the phase vocoder. Proceedings of the 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Milan, Italy.","DOI":"10.1109\/EMBC.2015.7318655"},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Naraharisetti, K.V.P., Bawa, M., and Tahernezhadi, M. (2011, January 15\u201317). Comparison of different signal processing methods for reducing artifacts from photoplethysmograph signal. Proceedings of the IEEE international conference on electro\/information technology, Mankato, MN, USA.","DOI":"10.1109\/EIT.2011.5978571"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/3\/673\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T12:31:28Z","timestamp":1760185888000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/3\/673"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2,7]]},"references-count":25,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2019,2]]}},"alternative-id":["s19030673"],"URL":"https:\/\/doi.org\/10.3390\/s19030673","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,2,7]]}}}