{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,23]],"date-time":"2026-03-23T19:17:47Z","timestamp":1774293467848,"version":"3.50.1"},"reference-count":84,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2019,2,24]],"date-time":"2019-02-24T00:00:00Z","timestamp":1550966400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100013332","name":"Linz Center of Mechatronics","doi-asserted-by":"publisher","award":["-"],"award-info":[{"award-number":["-"]}],"id":[{"id":"10.13039\/501100013332","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Linz Institute of Technology","award":["-"],"award-info":[{"award-number":["-"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Electromyography (EMG), the measurement of electrical muscle activity, is used in a variety of applications, including myoelectric upper-limb prostheses, which help amputees to regain independence and a higher quality of life. The state-of-the-art sensors in prostheses have a conductive connection to the skin and are therefore sensitive to sweat and require preparation of the skin. They are applied with some pressure to ensure a conductive connection, which may result in pressure marks and can be problematic for patients with circulatory disorders, who constitute a major group of amputees. Due to their insulating layer between skin and sensor area, capacitive sensors are insensitive to the skin condition, they require neither conductive connection to the skin nor electrolytic paste or skin preparation. Here, we describe a highly stable, low-power capacitive EMG measurement set-up that is suitable for real-world application. Various flexible multi-layer sensor set-ups made of copper and insulating foils, flex print and textiles were compared. These flexible sensor set-ups adapt to the anatomy of the human forearm, therefore they provide high wearing comfort and ensure stability against motion artifacts. The influence of the materials used in the sensor set-up on the magnitude of the coupled signal was demonstrated based on both theoretical analysis and measurement.The amplifier circuit was optimized for high signal quality, low power consumption and mobile application. Different shielding and guarding concepts were compared, leading to high SNR.<\/jats:p>","DOI":"10.3390\/s19040961","type":"journal-article","created":{"date-parts":[[2019,2,25]],"date-time":"2019-02-25T03:06:52Z","timestamp":1551064012000},"page":"961","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":38,"title":["An Insulated Flexible Sensor for Stable Electromyography Detection: Application to Prosthesis Control"],"prefix":"10.3390","volume":"19","author":[{"given":"Theresa","family":"Roland","sequence":"first","affiliation":[{"name":"Institute of Biomedical Mechatronics, Johannes Kepler University, 4040 Linz, Austria"}]},{"given":"Kerstin","family":"Wimberger","sequence":"additional","affiliation":[{"name":"Institute of Biomedical Mechatronics, Johannes Kepler University, 4040 Linz, Austria"}]},{"given":"Sebastian","family":"Amsuess","sequence":"additional","affiliation":[{"name":"Research and Development, Otto Bock Healthcare Products GmbH, 1110 Vienna, Austria"}]},{"given":"Michael Friedrich","family":"Russold","sequence":"additional","affiliation":[{"name":"Research and Development, Otto Bock Healthcare Products GmbH, 1110 Vienna, Austria"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3160-2050","authenticated-orcid":false,"given":"Werner","family":"Baumgartner","sequence":"additional","affiliation":[{"name":"Institute of Biomedical Mechatronics, Johannes Kepler University, 4040 Linz, Austria"}]}],"member":"1968","published-online":{"date-parts":[[2019,2,24]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Phinyomark, A., Khushaba, R.N., and Scheme, E. (2018). Feature Extraction and Selection for Myoelectric Control Based on Wearable EMG Sensors. Sensors, 18.","DOI":"10.3390\/s18051615"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"82","DOI":"10.2478\/v10048-012-0015-8","article-title":"Application of Linear Discriminant Analysis in Dimensionality Reduction for Hand Motion Classification","volume":"12","author":"Phinyomark","year":"2012","journal-title":"Meas. Sci. Rev."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"17","DOI":"10.3389\/fnbot.2016.00017","article-title":"Assessment of a Wearable Force- and Electromyography Device and Comparison of the Related Signals for Myocontrol","volume":"10","author":"Connan","year":"2016","journal-title":"Front. Neurorobot."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"7","DOI":"10.3389\/fneur.2017.00007","article-title":"Proof of Concept of an Online EMG-Based Decoding of Hand Postures and Individual Digit Forces for Prosthetic Hand Control","volume":"8","author":"Gailey","year":"2017","journal-title":"Front. Neurol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"7","DOI":"10.3389\/fnbot.2016.00007","article-title":"The Reality of Myoelectric Prostheses: Understanding What Makes These Devices Difficult for Some Users to Control","volume":"10","author":"Chadwell","year":"2016","journal-title":"Front. Neurorobot."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1682\/JRRD.2015.03.0041","article-title":"High-density force myography: A possible alternative for upper-limb prosthetic control","volume":"53","author":"Radmand","year":"2016","journal-title":"J. Rehabil. Res. Dev."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"496","DOI":"10.3389\/fnins.2015.00496","article-title":"Upper-Limb Prosthetic Myocontrol: Two Recommendations","volume":"9","author":"Castellini","year":"2016","journal-title":"Front. Neurosci."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"51","DOI":"10.3389\/fnbot.2017.00051","article-title":"Improving the Robustness of Electromyogram-Pattern Recognition for Prosthetic Control by a Postprocessing Strategy","volume":"11","author":"Zhang","year":"2017","journal-title":"Front. Neurorobot."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"379","DOI":"10.3389\/fnins.2017.00379","article-title":"Self-Recalibrating Surface EMG Pattern Recognition for Neuroprosthesis Control Based on Convolutional Neural Network","volume":"11","author":"Zhai","year":"2017","journal-title":"Front. Neurosci."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"8235","DOI":"10.3390\/s140508235","article-title":"Design, Development and Testing of a Low-Cost sEMG System and Its Use in Recording Muscle Activity in Human Gait","volume":"14","author":"Supuk","year":"2014","journal-title":"Sensors"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"18","DOI":"10.3389\/fbioe.2016.00018","article-title":"Force Myography to Control Robotic Upper Extremity Prostheses: A Feasibility Study","volume":"4","author":"Cho","year":"2016","journal-title":"Front. Bioeng. Biotechnol."},{"key":"ref_12","unstructured":"Fougner, A., Scheme, E., Chan, A.D.C., Englehart, K., and Stavdahl, O. (September, January 30). A multi-modal approach for hand motion classification using surface EMG and accelerometers. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Boston, MA, USA."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Gargiulo, G., and McEwan, A. (2011). Sensor Developments for Electrophysiological Monitoring in Healthcare. Applied Biomedical Engineering, InTech.","DOI":"10.5772\/764"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1007\/s11517-010-0597-y","article-title":"Thin and flexible active electrodes with shield for capacitive electrocardiogram measurement","volume":"48","author":"Lee","year":"2010","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1088\/0967-3334\/31\/10\/S03","article-title":"Insulating electrodes: A review on biopotential front ends for dielectric skin\u2013electrode interfaces","volume":"31","author":"Spinelli","year":"2010","journal-title":"Physiol. Meas."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"956","DOI":"10.1109\/TBME.2006.872823","article-title":"ECG measurement on a chair without conductive contact","volume":"53","author":"Lim","year":"2006","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_17","unstructured":"Richardson, P.C., and Lopez, A. (1967). Electrocardiographic and Bioelectric Capacitive Electrode. (3500823A), U.S. Patent."},{"key":"ref_18","unstructured":"Ueno, A., Akabane, Y., Mizuta, A., Kataoka, S., Hoshino, H., and Ishiyama, Y. (September, January 27). A System for Detecting Electrocardiographic Potential through Underwear Worn by an Infant from Its Dorsal Surface. Proceedings of the World Congress on Medical Physics and Biomedical Engineering, Seoul, Korea."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"81","DOI":"10.14326\/abe.1.81","article-title":"Underwater Electromyographic Measurement Using a Waterproof Insulated Electrode","volume":"1","author":"Ohtsu","year":"2012","journal-title":"ABE"},{"key":"ref_20","unstructured":"Oehler, M. (2010). Kapazitive Elektroden zur Messung bioelektrischer Signale. [Ph.D. Thesis, Technische Universit\u00e4t Braunschweig]."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Ng, C.L., and Reaz, M.B.I. (2017). Characterization of Textile-Insulated Capacitive Biosensors. Sensors, 17.","DOI":"10.3390\/s17030574"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Roland, T., Amsuess, S., Russold, M.F., Wolf, C., and Baumgartner, W. (2016). Capacitive Sensing of Surface EMG for Upper Limb Prostheses Control. Procedia Engineering, Eurosensors.","DOI":"10.1016\/j.proeng.2016.11.190"},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Roland, T., Baumgartner, W., Amsuess, S., and Russold, M.F. (2016, January 4\u20138). Signal evaluation of capacitive EMG for upper limb prostheses control using an ultra-low-power microcontroller. Proceedings of the IEEE EMBS Conference on Biomedical Engineering and Sciences (IECBES), Kuala Lumpur, Malaysia.","DOI":"10.1109\/IECBES.2016.7843465"},{"key":"ref_24","unstructured":"Roland, T., Mairhofer, S., Roland, W., Diskus, C., Amsuess, S., Russold, M.F., Wolf, C., and Baumgartner, W. (2016). Evaluation of Capacitive EMG Sensor Geometries by Simulation and Measurement. Scientific Computing in Electrical Engineering, Springer International Publishing."},{"key":"ref_25","unstructured":"Tyco Electronics (2019, January 09). UMCC\u2014Ultraminiature Coax Connector & Cable Assembly Series. Available online: https:\/\/www.te.com\/commerce\/DocumentDelivery\/DDEController?Action=showdoc&DocId=Catalog+Section%7F1307191_UMCC_Connectors%7F0307%7Fpdf%7FEnglish%7FENG_CS_1307191_UMCC_Connectors_0307.pdf%7F1775230-1."},{"key":"ref_26","unstructured":"DuPont (2019, January 09). Dupont Pyralux LF Sheet Adhesive Flexible Composites. Available online: http:\/\/www.dupont.com\/content\/dam\/dupont\/products-and-services\/electronic-and-electrical-materials\/flexible-rigid-flex-circuit-materials\/documents\/PyraluxLFadhesive_DataSheet.pdf."},{"key":"ref_27","unstructured":"Epectec (2019, January 09). Flex Circuit Design Guide. Available online: https:\/\/www.epectec.com\/downloads\/Flex-Circuit-Design-Guide.pdf."},{"key":"ref_28","unstructured":"Miyazaki, E., Mori, K., Ishizawa, J., and Shimamura, H. (2008, January 10\u201311). Evaluation of Silicone Potting Compound and Silicone Adhesive Exposed to Space on SM\/SEED Experiment. Proceedings of the International Symposium on \u201cSM\/MPAC&SEED Experiment\u201d, Tsukuba, Japan."},{"key":"ref_29","unstructured":"(2019, January 09). d-c-fix F3460013 Klebefolie, Vinyl, Transparent, 200 \u00d7 45 cm. Product Description. Available online: https:\/\/www.amazon.de\/d-c-fix-F3465001-Klebefolie-Vinyl-wei%C3%9F\/dp\/B005GJCCDS?ref_=bl_dp_s_web_2138306031."},{"key":"ref_30","unstructured":"BEMIS (2019, January 09). EXOFLEX (EXO3900) Aesthetic\/Functional Film. Available online: https:\/\/www.bemisworldwide.com\/PDF\/BEMIS_Web_Exoflex.pdf."},{"key":"ref_31","unstructured":"Moron (2017). Articulo Maline Ficha Tecnica, Moron. Technical Data Sheet Provided by Moron."},{"key":"ref_32","unstructured":"Bayer (2019, January 09). Technische Daten PLATILON\u00ae U Hochelastische Polyurethanfolien, Technical Data Sheet. Available online: https:\/\/www.films.covestro.com\/de\/Products\/~\/media\/013045757CC2401D83DF0B6F1169CAB5.ashx?la=de&force=1&la=de&force=1."},{"key":"ref_33","unstructured":"Plastics International (2019, January 09). Polyvinyl Chloride. Technical Data Sheet. Available online: http:\/\/www.sdplastics.com\/pvcsheet.html."},{"key":"ref_34","unstructured":"Lotz, P. (2010). Dielektrische Elastomerstapelaktoren f\u00fcr ein Peristaltisches Fluidf\u00f6rdersystem. [Ph.D. Thesis, TU Darmstadt]."},{"key":"ref_35","unstructured":"Huette, A.V.E. (1925). Das Ingenieurs Taschenbuch, Wilhelm Ernst & Sohn. [25th ed.]."},{"key":"ref_36","unstructured":"Tesafilm (2019, January 09). Tesafilm 4104 PVC Transparent Premium Verpackungsklebefilm (Transparent), Technical Data Sheet. Available online: https:\/\/www.tesa.com\/de-at\/files\/download\/371131,21,4104-country-pi-dt.pdf."},{"key":"ref_37","unstructured":"Advance Tapes (2019, January 09). AT525 35 Micron Copper Foil Shielding Tape. Technical Data Sheet. Available online: https:\/\/www.advancetapes.com\/wp-content\/uploads\/2017\/03\/AT525-ATI.pdf."},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Casas, O., and Pallas-Areny, R. (2007, January 22\u201326). Electrostatic Interference in Contactless Biopotential Measurements. Proceedings of the 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Lyon, France.","DOI":"10.1109\/IEMBS.2007.4352875"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1504\/IJBET.2015.068051","article-title":"Capacitive driven-right-leg circuit design","volume":"17","author":"Haberman","year":"2015","journal-title":"IJBET"},{"key":"ref_40","unstructured":"ST (2019, January 09). LD2985 Very Low Drop and Low Noise Voltage Regulator with Inhibit Function, Technical Data Sheet. Available online: https:\/\/www.st.com\/resource\/en\/datasheet\/ld2985.pdf."},{"key":"ref_41","unstructured":"Diodes Inc. (2019, January 09). AP7312 Dual 150mA Low Quiescent Current Fast Transient Low Dropout Linear Regulator, Technical Data Sheet. Available online: https:\/\/www.diodes.com\/assets\/Datasheets\/AP7312.pdf."},{"key":"ref_42","unstructured":"AnalogDevices (2019, January 09). 40 microAmpere Micropower Instrumentation Amplifier with Zero Crossover Distortion, Technical Data Sheet. Available online: https:\/\/www.analog.com\/media\/en\/technical-documentation\/data-sheets\/ad8236.pdf."},{"key":"ref_43","doi-asserted-by":"crossref","unstructured":"Sullivan, T.J., Deiss, S., and Cauwenberghs, G. (2007, January 27\u201330). A Low-Noise, Non-Contact EEG\/ECG Sensor. Proceedings of the IEEE Biomedical Circuits and Systems Conference, Montreal, QC, Canada.","DOI":"10.1109\/BIOCAS.2007.4463332"},{"key":"ref_44","unstructured":"Basmajian, J.V., and Luca, C.J.D. (1962). Muscles Alive: Their Functions Revealed by Electromyography, The Williams & Wilkins Company. [2nd ed.]."},{"key":"ref_45","unstructured":"Microchip (2019, January 09). MCP6021\/1R\/2\/3\/4 Rail-to-Rail Input\/Output, 10 MHz Op Amps, Technical Data Sheet. Available online: http:\/\/ww1.microchip.com\/downloads\/en\/devicedoc\/20001685e.pdf."},{"key":"ref_46","unstructured":"Texas Instruments (2019, January 09). Instrumentation Amplifier with DC Rejection Reference Design, Technical Data Sheet. Available online: http:\/\/www.ti.com\/lit\/ug\/tidu990\/tidu990.pdf."},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Jiang, Y., Samuel, O., Liu, X., Wang, X., Idowu, P., Li, P., Chen, F., Zhu, M., Geng, Y., and Wu, F. (2018). Effective Biopotential Signal Acquisition: Comparison of Different Shielded Drive Technologies. Appl. Sci., 8.","DOI":"10.3390\/app8020276"},{"key":"ref_48","unstructured":"Hann, M. (2019, January 09). Analog Fundamentals of the ECG Signal Chain, Texas Instruments. Available online: https:\/\/ece480group6.files.wordpress.com\/2012\/11\/design-considerations-for-ecg-systems-hann-apr2010-compatibility-mode.pdf."},{"key":"ref_49","unstructured":"Bronzino, J.D., and Peterson, D.R. (2015). The Biomedical Engineering Handbook, CRC Press. [4th ed.]."},{"key":"ref_50","first-page":"1458","article-title":"Shielding Methodologies in the Presence of Power\/Ground Noise","volume":"19","author":"Kose","year":"2011","journal-title":"T-VLSI"},{"key":"ref_51","unstructured":"Burr Brown (2019, January 09). INA111 High Speed FET-Input Instrumentation Amplifier, Technical Data Sheet. Available online: http:\/\/www.ti.com.cn\/cn\/lit\/ds\/symlink\/ina111.pdf."},{"key":"ref_52","unstructured":"Microchip (2019, January 09). SMART ARM-Based Microcontrollers SAM L21 Family Data Sheet, Technical Data Sheet. Available online: http:\/\/ww1.microchip.com\/downloads\/en\/DeviceDoc\/60001477A.pdf."},{"key":"ref_53","doi-asserted-by":"crossref","unstructured":"Roland, T., Amsuess, S., Russold, M.F., and Baumgartner, W. (2019). Ultra-Low-Power Digital Filtering for Insulated EMG Sensing. Sensors, under review.","DOI":"10.3390\/s19040959"},{"key":"ref_54","doi-asserted-by":"crossref","unstructured":"Portelli, A., and Nasuto, S. (2017). Design and Development of Non-Contact Bio-Potential Electrodes for Pervasive Health Monitoring Applications. Biosensors, 7.","DOI":"10.3390\/bios7010002"},{"key":"ref_55","doi-asserted-by":"crossref","unstructured":"Prutchi, D., and Norris, M. (2005). Design and Development of Medical Electronic Instrumentation: A Practical Perspective of the Design, Construction, and Test of Medical Devices, John Wiley & Sons, Inc.","DOI":"10.1002\/0471681849"},{"key":"ref_56","unstructured":"Heuer, S. (2011). Ambiente kapazitive EKG-Messung\u2014Elektroden, Systeme und Konzepte. [Ph.D. Thesis, Karlsruher Institute of Technology (KIT)]."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1109\/TBME.1964.4502292","article-title":"Solid-State Electrometers with Input-Capacitance Neutralization","volume":"11","author":"Fein","year":"1964","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_58","unstructured":"Gomez-Clapers, J., Serrano-Finetti, E., Casanella, R., and Pallas-Areny, R. (September, January 30). Can driven-right-leg circuits increase interference in ECG amplifiers?. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Boston, MA, USA."},{"key":"ref_59","doi-asserted-by":"crossref","unstructured":"Nazmi, N., Rahman, M.A., Yamamoto, S.I., Ahmad, S., Zamzuri, H., and Mazlan, S. (2016). A Review of Classification Techniques of EMG Signals during Isotonic and Isometric Contractions. Sensors, 16.","DOI":"10.3390\/s16081304"},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.brainresbull.2012.09.012","article-title":"A note on the probability distribution function of the surface electromyogram signal","volume":"90","author":"Nazarpour","year":"2013","journal-title":"Brain Res. Bull."},{"key":"ref_61","doi-asserted-by":"crossref","unstructured":"Ahamed, N.U., Sundaraj, K., Ahmad, R.B., Rahman, M., and Islam, M.A. (2012, January 4\u20136). Analysis of Right Arm Biceps Brachii Muscle Activity with Varying the Electrode Placement on Three Male Age Groups During Isometric Contractions Using a Wireless EMG Sensor. Proceedings of the International Symposium on Robotics and Intelligent Sensors, Kuching, Sarawak, Malaysia.","DOI":"10.1016\/j.proeng.2012.07.143"},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1007\/s00221-009-2110-0","article-title":"Fatigue related changes in electromyographic coherence between synergistic hand muscles","volume":"202","author":"Kattla","year":"2009","journal-title":"Exp. Brain Res."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1016\/j.sna.2003.10.071","article-title":"Towards the integration of textile sensors in a wireless monitoring suit","volume":"114","author":"Catrysse","year":"2004","journal-title":"Sens. Actuators A Phys."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/j.sna.2012.04.019","article-title":"Preliminary technological assessment of microneedles-based dry electrodes for biopotential monitoring in clinical examinations","volume":"180","author":"Forvi","year":"2012","journal-title":"Sens. Actuators A Phys."},{"key":"ref_65","unstructured":"Chemours (2019, January 09). Teflon FEP Fluoropolymer Film, Technical Data Sheet. Available online: https:\/\/www.chemours.com\/Teflon_Industrial\/en_US\/assets\/downloads\/teflon-fep-film-technical-information.pdf."},{"key":"ref_66","unstructured":"TiePie Engineering (2019, January 09). HANDYSCOPE MODEL HS3 A Portable 100 MS\/s Instrument Connected to USB 2.0 and USB 1.1, Handyscope HS3 Specifications. Available online: https:\/\/www.tiepie.com\/en\/usb-oscilloscope\/handyscope-hs3\/specifications."},{"key":"ref_67","unstructured":"TiePie Engineering (2018, February 07). Multi Channel Oscilloscope Software. Available online: https:\/\/www.tiepie.com\/en\/oscilloscope-software."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1016\/j.jelekin.2012.01.011","article-title":"Influence of Amplitude Cancellation on the Accuracy of Determining the Onset of Muscle Activity from the Surface Electromyogram","volume":"22","author":"Jesunathadas","year":"2012","journal-title":"J. Electromyogr. Kinesiol."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1152\/japplphysiol.00894.2004","article-title":"Influence of amplitude cancellation on the simulated surface electromyogram","volume":"98","author":"Keenan","year":"2005","journal-title":"J. Appl. Physiol."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"2144","DOI":"10.1152\/jn.2001.86.5.2144","article-title":"Experimental simulation of cat electromyogram: evidence for algebraic summation of motor-unit action-potential trains","volume":"86","author":"Day","year":"2001","journal-title":"J. Neurophysiol."},{"key":"ref_71","doi-asserted-by":"crossref","unstructured":"Jiralerspong, T., Nakanishi, E., Liu, C., and Ishikawa, J. (2017). Experimental Study of Real-Time Classification of 17 Voluntary Movements for Multi-Degree Myoelectric Prosthetic Hand. Appl. Sci., 7.","DOI":"10.3390\/app7111163"},{"key":"ref_72","unstructured":"MathWorks\u00ae (2016). MATLAB\u00ae and Statistics Toolbox Release 2016b, The MathWorks\u00ae, Inc."},{"key":"ref_73","unstructured":"D\u2019Augustino, R.B., and Stephens, M.A. (1986). Goodness-of-Fit-Techniques, CRC Press."},{"key":"ref_74","first-page":"268","article-title":"Properties of Sufficiency and Statistical Tests","volume":"160","author":"Bartlett","year":"1937","journal-title":"Proc. R. Soc. Lond. Ser. A Math. Phys. Sci."},{"key":"ref_75","unstructured":"Bornemann-Cimenti, H., Szilagyi, I.S., and Sandner-Kiesling, A. (2015). Wissenschaftliches Arbeiten in der Klinik: Ein Leitfaden f\u00fcr die ersten Wissenschaftlichen Erfahrungen und das Verfassen von Abschlussarbeiten (MV-Wissenschaft), Monsenstein und Vannerdat."},{"key":"ref_76","doi-asserted-by":"crossref","unstructured":"Hou, W., Jiang, Y., Zheng, J., Zheng, X., Peng, C., and Xu, R. (2007, January 23\u201327). Handgrip Force Estimation Based on a Method Using Surface Electromyography (sEMG) of Extensor Carpi Radialis Longus. Proceedings of the International Conference on Complex Medical Engineering, Beijing, China.","DOI":"10.1109\/ICCME.2007.4381940"},{"key":"ref_77","first-page":"1653","article-title":"Myoelectric signal versus force relationship in different human muscles","volume":"54","author":"Lawrence","year":"1983","journal-title":"J. Appl. Physiol. Respir. Environ. Exerc. Physiol."},{"key":"ref_78","unstructured":"Microchip (2019, January 09). Bluetooth\u00ae 4.2 Low Energy Module RN4870\/71, Technical Data Sheet. Available online: http:\/\/ww1.microchip.com\/downloads\/en\/DeviceDoc\/50002489C.pdf."},{"key":"ref_79","unstructured":"(2019, January 09). 13E401, Otto Bock Healthcare GmbH, Otto Bock. Available online: https:\/\/www.ottobock.at\/."},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1111\/1523-1747.ep12507517","article-title":"Hydration Characteristics and Electrical Resistivity of Stratum Corneum Using a Noninvasive Four-Point Microelectrode Method","volume":"69","author":"Campell","year":"1977","journal-title":"J. Investig. Dermatol."},{"key":"ref_81","unstructured":"Kirst, M. (2012). Verbesserung der Automatischen EKG-Analyse durch Hinzunahme von Kontextinformationen. [Ph.D. Thesis, Karlsruher Institute of Technology (KIT)]."},{"key":"ref_82","unstructured":"(2019, January 09). Surface EMG Sensor (SX230), Biometrics. Available online: http:\/\/www.biometricsltd.com\/surface-emg-sensor.htm."},{"key":"ref_83","unstructured":"(2019, January 09). Bagnoli TM Surface EMG Sensor, Delsys. Available online: https:\/\/www.delsys.com\/products\/desktop-emg\/surface-emg-sensors\/."},{"key":"ref_84","unstructured":"(2019, January 09). MyoWareTM Muscle Sensor (AT-04-001), Technical Data Sheet. Available online: https:\/\/cdn.sparkfun.com\/assets\/a\/3\/a\/f\/a\/AT-04-001.pdf."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/4\/961\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T12:34:30Z","timestamp":1760186070000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/4\/961"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2,24]]},"references-count":84,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2019,2]]}},"alternative-id":["s19040961"],"URL":"https:\/\/doi.org\/10.3390\/s19040961","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,2,24]]}}}