{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,2]],"date-time":"2026-04-02T19:35:56Z","timestamp":1775158556381,"version":"3.50.1"},"reference-count":28,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2019,3,7]],"date-time":"2019-03-07T00:00:00Z","timestamp":1551916800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["31670716"],"award-info":[{"award-number":["31670716"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100002858","name":"China Postdoctoral Science Foundation","doi-asserted-by":"publisher","award":["2015M570945"],"award-info":[{"award-number":["2015M570945"]}],"id":[{"id":"10.13039\/501100002858","id-type":"DOI","asserted-by":"publisher"}]},{"name":"China Postdoctoral Science Special Foundation","award":["2016T90044"],"award-info":[{"award-number":["2016T90044"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>To efficiently harvest environmental micro-energy from shallow soil, simulated analysis, theoretical arithmetic and experimental verification are performed to explore the spatiotemporal rules of heat transfer on a soil\/finned tube interface. Simulations are carried out for 36 types of different working conditions, and the empirical formulas for temperature and heat flux are obtained. The temperature and heat flux can be calculated using the formulas if the soil temperature, soil moisture content and finned tube initial temperature are known. The simulations also show that the highest heat flux can reach approximately 0.30 mW\/mm2, and approximately 1507.96 mW of energy can be harvested through the finned tube. Theoretical arithmetic indicates that the heat transfer rate of the copper finned tube is 76.77% higher than that of the bare tube, the highest rate obtained in any study to date. Results also show that the finned tube should be placed where the soil moisture is greater than 30% to get more heat from the soil. A field experiment is carried out in the city of Harbin in Northeast China, where a thermoelectric power generation device has been installed and temperature data have been monitored for a certain time. The results are in good agreement with those obtained from the simulation analysis. The heat transfer processes and heat transfer steady state on the soil\/finned tube interface are revealed in this work and are of great importance for the use of geothermal energy.<\/jats:p>","DOI":"10.3390\/s19051159","type":"journal-article","created":{"date-parts":[[2019,3,8]],"date-time":"2019-03-08T04:58:35Z","timestamp":1552021115000},"page":"1159","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Spatiotemporal Rule of Heat Transfer on a Soil\/Finned Tube Interface"],"prefix":"10.3390","volume":"19","author":[{"given":"Yongsheng","family":"Huang","sequence":"first","affiliation":[{"name":"Key Lab of State Forestry Administration on Forestry Equipment and Automation, School of Technology, Beijing Forestry University, Beijing 100083, China"}]},{"given":"Wenbin","family":"Li","sequence":"additional","affiliation":[{"name":"Key Lab of State Forestry Administration on Forestry Equipment and Automation, School of Technology, Beijing Forestry University, Beijing 100083, China"}]},{"given":"Daochun","family":"Xu","sequence":"additional","affiliation":[{"name":"Key Lab of State Forestry Administration on Forestry Equipment and Automation, School of Technology, Beijing Forestry University, Beijing 100083, China"}]},{"given":"Yafeng","family":"Wu","sequence":"additional","affiliation":[{"name":"Key Lab of State Forestry Administration on Forestry Equipment and Automation, School of Technology, Beijing Forestry University, Beijing 100083, China"}]}],"member":"1968","published-online":{"date-parts":[[2019,3,7]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/j.enconman.2012.12.029","article-title":"Performance factors for ground-air thermoelectric power generators","volume":"68","author":"Stevens","year":"2013","journal-title":"Energy Convers. Manag."},{"key":"ref_2","unstructured":"Lawrence, E.E., and Snyder, G.J. (2002, January 29). A study of heat sink performance in air and soil for use in a thermoelectric energy harvesting device. Proceedings of the Twenty-First International Conference on Thermoelectrics, Long Beach, CA, USA."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1016\/j.enconman.2015.03.060","article-title":"Behavior of a thermoelectric power generation device based on solar irradiation and the earth\u2019s surface-air temperature difference","volume":"97","author":"Zhang","year":"2015","journal-title":"Energy Convers. Manag."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1016\/j.enconman.2016.09.023","article-title":"Theoretical and experimental analysis of a solar thermoelectric power generation device based on gravity-assisted heat pipes and solar irradiation","volume":"127","author":"Zhang","year":"2016","journal-title":"Energy Convers. Manag."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1631","DOI":"10.1016\/j.enconman.2004.07.006","article-title":"Development and testing of a domestic woodstove thermoelectric generator with natural convection cooling","volume":"46","author":"Nuwayhid","year":"2005","journal-title":"Energy Convers. Manag."},{"key":"ref_6","first-page":"84","article-title":"Study on forest soil thermoelectric power generation based on the Seebeck effect","volume":"38","author":"Huang","year":"2018","journal-title":"J. For. Environ."},{"key":"ref_7","first-page":"1","article-title":"Feasibility study of a new thermoelectric conversion device utilizing the temperature differences in forest soil","volume":"62","author":"Wang","year":"2017","journal-title":"Acta Tech. CSAV (Ceskoslovensk Akad. Ved)"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1288","DOI":"10.1016\/j.enbuild.2011.01.007","article-title":"Parameters optimization of a vertical ground heat exchanger based on response surface methodology","volume":"43","author":"Khalajzadeh","year":"2011","journal-title":"Energy Build."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"2497","DOI":"10.1007\/s12206-013-0637-2","article-title":"Investigation of the effects of geometrical parameters on heat transfer from buried finned pipes","volume":"27","author":"Demir","year":"2013","journal-title":"J. Mech. Sci. Technol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.geothermics.2018.01.009","article-title":"Numerical modelling of transient soil temperature distribution for horizontal ground heat exchanger of ground source heat pump","volume":"73","author":"Kayaci","year":"2018","journal-title":"Geothermics"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1016\/j.applthermaleng.2013.09.014","article-title":"Transient heat transfer in a U-tube borehole heat exchanger","volume":"62","author":"Beier","year":"2014","journal-title":"Appl. Therm. Eng."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"538","DOI":"10.1016\/j.jclepro.2018.02.089","article-title":"Thermal design of Earth-to-Air Heat Exchanger. Part I a new transient semi-analytical model for determining soil temperature","volume":"182","author":"Rouag","year":"2018","journal-title":"J. Clean. Prod."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"3679","DOI":"10.1016\/j.applthermaleng.2009.06.025","article-title":"Soil temperature distribution around a U-tube heat exchanger in a multi-function ground source heat pump system","volume":"29","author":"Li","year":"2009","journal-title":"Appl. Therm. Eng."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1023","DOI":"10.1016\/j.applthermaleng.2016.06.048","article-title":"Numerical investigation on thermal performance of ground heat exchangers using phase change materials as grout for ground source heat pump system","volume":"106","author":"Qi","year":"2016","journal-title":"Appl. Therm. Eng."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.applthermaleng.2012.12.036","article-title":"Borehole thermal response and thermal resistance of four different grouting materials measured with a TRT","volume":"53","year":"2013","journal-title":"Appl. Therm. Eng."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1016\/j.renene.2014.06.007","article-title":"Simulation and experimental analysis of optimal buried depth of the vertical U-tube ground heat exchanger for a ground-coupled heat pump system","volume":"73","author":"Chen","year":"2015","journal-title":"Renew. Energy"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/j.applthermaleng.2015.01.027","article-title":"Numerical investigation of a novel tube design for the geothermal borehole heat exchanger","volume":"79","author":"Bouhacina","year":"2015","journal-title":"Appl. Therm. Eng."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1185","DOI":"10.1016\/j.applthermaleng.2016.11.019","article-title":"An exhaust heat recovery system utilising thermoelectric generators and heat pipes","volume":"126","author":"Orr","year":"2017","journal-title":"Appl. Therm. Eng."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"854","DOI":"10.1016\/j.rser.2016.07.041","article-title":"Evaluation of experimental JUST thermoelectric stove for electricity- Deprived regions","volume":"69","author":"Najjar","year":"2017","journal-title":"Renew. Sustain. Energy Rev."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"3137","DOI":"10.1007\/s11664-016-5223-9","article-title":"Optimal Number of Thermoelectric Couples in a Heat Pipe Assisted Thermoelectric Generator for Waste Heat Recovery","volume":"46","author":"Liu","year":"2017","journal-title":"J. Electron. Mater."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1016\/j.enconman.2016.11.005","article-title":"Human body heat for powering wearable devices: From thermal energy to application","volume":"131","author":"Thielen","year":"2017","journal-title":"Energy Convers. Manag."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"2361","DOI":"10.1016\/j.enconman.2009.05.019","article-title":"Assessment of near-surface ground temperature profiles for optimal placement of a thermoelectric device","volume":"50","author":"Maixner","year":"2009","journal-title":"Energy Convers. Manag."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"761","DOI":"10.1080\/15435075.2013.829474","article-title":"A Numerical Model for the Simulation of a Vertical U-Bend Ground Heat Exchanger Used in a Ground-Coupled Heat Pump","volume":"11","author":"Yang","year":"2014","journal-title":"Int. J. Green Energy"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"739","DOI":"10.1016\/j.icheatmasstransfer.2009.03.022","article-title":"Experimental study of heat transfer of buried finned pipe for ground source heat pump applications","volume":"36","author":"Koyun","year":"2009","journal-title":"Int. Commun. Heat Mass Transf."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1016\/j.applthermaleng.2018.01.020","article-title":"Numerical modeling of energy transfer in underground borehole heat exchanger within unsaturated soil","volume":"132","author":"Jahangir","year":"2018","journal-title":"Appl. Therm. Eng."},{"key":"ref_26","first-page":"475","article-title":"A short time step response factor model for vertical ground loop heat exchangers","volume":"105","author":"Yavuzturk","year":"1999","journal-title":"ASHRAE Trans."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1016\/j.renene.2017.12.070","article-title":"Experimental study to investigate the effect of water impregnation on thermal performance of earth air tunnel heat exchanger for summer cooling in hot and arid climate","volume":"120","author":"Agrawal","year":"2018","journal-title":"Renew. Energy"},{"key":"ref_28","unstructured":"Chen, Y., and Wu, W. (2004). Heat Engineering, Higher Education Press."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/5\/1159\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T12:37:02Z","timestamp":1760186222000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/5\/1159"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,3,7]]},"references-count":28,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2019,3]]}},"alternative-id":["s19051159"],"URL":"https:\/\/doi.org\/10.3390\/s19051159","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,3,7]]}}}