{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T16:49:32Z","timestamp":1784306972758,"version":"3.55.0"},"reference-count":43,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2019,3,8]],"date-time":"2019-03-08T00:00:00Z","timestamp":1552003200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100012166","name":"National Key Research and Development Program of China","doi-asserted-by":"publisher","award":["2017YFB0406303"],"award-info":[{"award-number":["2017YFB0406303"]}],"id":[{"id":"10.13039\/501100012166","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This work reports a novel wireless microfluidic biosensor based on low temperature co-fired ceramic (LTCC) technology. The wireless biosensor consists of a planar spiral inductor and parallel plate capacitor (LC) resonant antenna, which integrates with microchannel bends in the LTCC substrate. The wireless response of the biosensor was associated to the changes of its resonant frequency due to the alteration in the permittivity of the liquid flow in the microchannel. The wireless sensing performance to different organic liquids with permittivity from 3 to 78.5 was presented. The measured results are in good agreement with the theoretical calculation. The wireless detection for the concentration of glucose in water solution was investigated, and an excellent linear response and repeatability were obtained. This kind of LC wireless microfluidic sensor is very promising in establishing wireless lab-on-a-chip for biomedical and chemical applications.<\/jats:p>","DOI":"10.3390\/s19051189","type":"journal-article","created":{"date-parts":[[2019,3,8]],"date-time":"2019-03-08T11:21:59Z","timestamp":1552044119000},"page":"1189","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":36,"title":["An LC Wireless Microfluidic Sensor Based on Low Temperature Co-Fired Ceramic (LTCC) Technology"],"prefix":"10.3390","volume":"19","author":[{"given":"Yongyuan","family":"Liang","sequence":"first","affiliation":[{"name":"CAS Key Laboratory of Inorganic Functional Materials and Devices, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050, China"},{"name":"Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4485-2945","authenticated-orcid":false,"given":"Mingsheng","family":"Ma","sequence":"additional","affiliation":[{"name":"CAS Key Laboratory of Inorganic Functional Materials and Devices, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Faqiang","family":"Zhang","sequence":"additional","affiliation":[{"name":"CAS Key Laboratory of Inorganic Functional Materials and Devices, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Feng","family":"Liu","sequence":"additional","affiliation":[{"name":"CAS Key Laboratory of Inorganic Functional Materials and Devices, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhifu","family":"Liu","sequence":"additional","affiliation":[{"name":"CAS Key Laboratory of Inorganic Functional Materials and Devices, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050, China"},{"name":"Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dong","family":"Wang","sequence":"additional","affiliation":[{"name":"CAS Key Laboratory of Inorganic Functional Materials and Devices, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050, China"},{"name":"Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yongxiang","family":"Li","sequence":"additional","affiliation":[{"name":"School of Engineering, RMIT University, Melbourne VIC 3001, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2019,3,8]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1038\/nature05058","article-title":"The origins and the future of microfluidics","volume":"442","author":"Whitesides","year":"2006","journal-title":"Nature"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"2550","DOI":"10.1021\/cr300337x","article-title":"Advances in microfluidic materials, functions, integration, and applications","volume":"113","author":"Nge","year":"2013","journal-title":"Chem. Rev."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"15949","DOI":"10.1038\/ncomms15949","article-title":"A point-of-care microfluidic biochip for quantification of CD64 expression from whole blood for sepsis stratification","volume":"8","author":"Hassan","year":"2017","journal-title":"Nat. Commun."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1700047","DOI":"10.1002\/biot.201700047","article-title":"Microfluidics Based Point-of-Care Diagnostics","volume":"13","author":"Pandey","year":"2018","journal-title":"Biotechnol. J."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1139","DOI":"10.1039\/C5LC01562F","article-title":"Distance-based microfluidic quantitative detection methods for point-of-care testing","volume":"16","author":"Tian","year":"2016","journal-title":"Lab Chip"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1038\/nature05064","article-title":"Microfluidic diagnostic technologies for global public health","volume":"442","author":"Yager","year":"2006","journal-title":"Nature"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1016\/j.bios.2017.07.024","article-title":"Advances in point-of-care technologies for molecular diagnostics","volume":"98","author":"Zarei","year":"2017","journal-title":"Biosens. Bioelectron."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1016\/j.trac.2017.07.013","article-title":"Point-of-care-testing of nucleic acids by microfluidics","volume":"94","author":"Zhang","year":"2017","journal-title":"TrAC Trends Anal. Chem."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Khan, R.S., Khurshid, Z., and Yahya Ibrahim Asiri, F. (2017). Advancing Point-of-Care (PoC) Testing Using Human Saliva as Liquid Biopsy. Diagnostics, 7.","DOI":"10.3390\/diagnostics7030039"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Chretiennot, T., Dubuc, D., and Grenier, K. (2016). Microwave-Based Microfluidic Sensor for Non-Destructive and Quantitative Glucose Monitoring in Aqueous Solution. Sensors, 16.","DOI":"10.3390\/s16101733"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/j.snb.2018.01.234","article-title":"Microfluidics-based hairpin resonator biosensor for biological cell detection","volume":"263","author":"Liu","year":"2018","journal-title":"Sens. Actuators B Chem."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"15807","DOI":"10.1038\/s41598-018-34001-w","article-title":"Sensitive, Real-time and Non-Intrusive Detection of Concentration and Growth of Pathogenic Bacteria using Microfluidic-Microwave Ring Resonator Biosensor","volume":"8","author":"Narang","year":"2018","journal-title":"Sci. Rep."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Salim, A., and Lim, S. (2016). Complementary Split-Ring Resonator-Loaded Microfluidic Ethanol Chemical Sensor. Sensors, 16.","DOI":"10.3390\/s16111802"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1016\/j.snb.2015.11.063","article-title":"Liquid sensing in aquatic environment using high quality planar microwave resonator","volume":"225","author":"Zarifi","year":"2016","journal-title":"Sens. Actuators B Chem."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1038\/s41598-017-18621-2","article-title":"Noncontact and Nonintrusive Microwave-Microfluidic Flow Sensor for Energy and Biomedical Engineering","volume":"8","author":"Zarifi","year":"2018","journal-title":"Sci. Rep."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"943","DOI":"10.1039\/C5LC01524C","article-title":"Novel developments in mobile sensing based on the integration of microfluidic devices and smartphones","volume":"16","author":"Yang","year":"2016","journal-title":"Lab Chip"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"3083","DOI":"10.1002\/smll.201400483","article-title":"Stretchable, wireless sensors and functional substrates for epidermal characterization of sweat","volume":"10","author":"Huang","year":"2014","journal-title":"Small"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"e1802876","DOI":"10.1002\/smll.201802876","article-title":"Soft, Skin-Interfaced Microfluidic Systems with Wireless, Battery-Free Electronics for Digital, Real-Time Tracking of Sweat Loss and Electrolyte Composition","volume":"14","author":"Kim","year":"2018","journal-title":"Small"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1038\/s41551-018-0336-5","article-title":"Biodegradable and flexible arterial-pulse sensor for the wireless monitoring of blood flow","volume":"3","author":"Boutry","year":"2019","journal-title":"Nat. Biomed. Eng."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1241","DOI":"10.1016\/j.microrel.2011.02.018","article-title":"LTCC package for high temperature applications","volume":"51","author":"Nowak","year":"2011","journal-title":"Microelectron. Reliab."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"803","DOI":"10.1016\/j.snb.2017.06.073","article-title":"Dopamine sensing with fluorescence strategy based on low temperature co-fired ceramic technology modified with conducting polymers","volume":"252","author":"Baluta","year":"2017","journal-title":"Sens. Actuators B Chem."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"012001","DOI":"10.1088\/1757-899X\/104\/1\/012001","article-title":"LTCC based bioreactors for cell cultivation","volume":"104","author":"Bartsch","year":"2016","journal-title":"IOP Conf. Ser. Mater. Sci. Eng."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1871","DOI":"10.3762\/bjnano.7.179","article-title":"Low temperature co-fired ceramic packaging of CMOS capacitive sensor chip towards cell viability monitoring","volume":"7","author":"Halonen","year":"2016","journal-title":"Beilstein J. Nanotechnol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1007\/s10404-012-1087-3","article-title":"Prospects of low temperature co-fired ceramic (LTCC) based microfluidic systems for point-of-care biosensing and environmental sensing","volume":"14","author":"Vasudev","year":"2012","journal-title":"Microfluid. Nanofluid."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1109\/JIOT.2014.2385798","article-title":"Implementation of Multiparameter Monitoring by an LC-Type Passive Wireless Sensor Through Specific Winding Stacked Inductors","volume":"2","author":"Lei","year":"2015","journal-title":"IEEE Internet Things J."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1016\/j.snb.2016.08.073","article-title":"A novel wireless gas sensor based on LTCC technology","volume":"239","author":"Ma","year":"2017","journal-title":"Sens. Actuators B Chem."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1016\/0370-1573(78)90009-1","article-title":"The dielectric constant of a composite material\u2014A problem in classical physics","volume":"43","author":"Bergman","year":"1978","journal-title":"Phys. Rep."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1303","DOI":"10.1109\/36.843023","article-title":"Effective permittivity of mixtures: Numerical validation by the FDTD method","volume":"38","author":"Karkkainen","year":"2000","journal-title":"IEEE Trans. Geosci. Remote Sens."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1021\/co200148q","article-title":"Combinatorial study of ceramic tape-casting slurries","volume":"14","author":"Liu","year":"2012","journal-title":"ACS Comb. Sci."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Lin, L., Ma, M., Zhang, F., Liu, F., Liu, Z., and Li, Y. (2018). Fabrications and Performance of Wireless LC Pressure Sensors through LTCC Technology. Sensors, 18.","DOI":"10.3390\/s18020340"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1049\/ip-h-2.1987.0068","article-title":"Dielectric measurements with an open-ended coaxial probe","volume":"134","author":"Marsland","year":"1987","journal-title":"IEEE Proc. H Microw. Antennas Propag."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1109\/TMTT.2014.2300066","article-title":"Novel Microwave Microfluidic Sensor Using a Microstrip Split-Ring Resonator","volume":"62","author":"Abduljabar","year":"2014","journal-title":"IEEE Trans. Microw. Theory Tech."},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Wessel, J., Schmalz, K., Scheytt, J.C., Cahill, B., and Gastrock, G. (November, January 29). Microwave Biosensor for Characterization of Compartments in Teflon Capillaries. Proceedings of the 2012 42nd European Microwave Conference (EuMC), Amsterdam, The Netherlands.","DOI":"10.23919\/EuMC.2012.6459231"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"4714","DOI":"10.1109\/TMTT.2013.2287478","article-title":"An Inkjet-Printed Microfluidic RFID-Enabled Platform for Wireless Lab-on-Chip Applications","volume":"61","author":"Cook","year":"2013","journal-title":"IEEE Trans. Microw. Theory Tech."},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Ambrozkiewicz, M., and Jacob, A.F. (2010, January 23\u201328). Substrate Integrated Resonant Near-Field Sensor for Material Characterization. Proceedings of the 2010 IEEE MTT-S International Microwave Symposium, Anaheim, CA, USA.","DOI":"10.1109\/MWSYM.2010.5517812"},{"key":"ref_36","unstructured":"Haase, N., and Jacob, A.F. (2013, January 6\u201310). Substrate-Integrated Half-Mode Resonant Near-Field Sensor for Liquid Characterization. Proceedings of the 2013 European Microwave Conference, Nuremberg, Germany."},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Silavwe, E., Somjit, N., and Robertson, I.D. (2016, January 4\u20136). Microwave Microlitre Lab-on-Substrate Liquid Characterisation based on SIW Slot Antenna. Proceedings of the 2016 46th European Microwave Conference (EuMC), London, UK.","DOI":"10.1109\/EuMC.2016.7824328"},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Ebrahimi, A., Withayachumnankul, W., Al-Sarawi, S.F., and Abbott, D. (December, January 3). Microwave microfluidic sensor for determination of glucose concentration in water. Proceedings of the 2015 IEEE 15th Mediterranean Microwave Symposium (MMS), Lecce, Italy.","DOI":"10.1109\/MMS.2015.7375441"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.snb.2013.02.096","article-title":"An LTCC-based microfluidic system for label-free, electrochemical detection of cortisol","volume":"182","author":"Vasudev","year":"2013","journal-title":"Sens. Actuators B Chem."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1016\/j.snb.2019.01.032","article-title":"Enzymatic method of urea determination in LTCC microfluidic system based on absorption photometry","volume":"285","author":"Remiszewska","year":"2019","journal-title":"Sens. Actuators B Chem."},{"key":"ref_41","doi-asserted-by":"crossref","unstructured":"Malecha, K., Jasi\u0144ska, L., Grytsko, A., Drzozga, K., S\u0142obodzian, P., and Cabaj, J. (2019). Monolithic Microwave-Microfluidic Sensors Made with Low Temperature Co-Fired Ceramic (LTCC) Technology. Sensors, 19.","DOI":"10.20944\/preprints201901.0037.v1"},{"key":"ref_42","doi-asserted-by":"crossref","unstructured":"Chen, T., Dubuc, D., and Grenier, K. (November, January 29). Resonant-based Microwave Biosensor for Physiological Liquid Identification. Proceedings of the 2012 42nd European Microwave Conference (EuMC), Amsterdam, The Netherlands.","DOI":"10.23919\/EuMC.2012.6459146"},{"key":"ref_43","doi-asserted-by":"crossref","unstructured":"Ciobanu, R., Schreiner, C., Drug, V., Schreiner, T., and Antal, D. (2015, January 7\u20139). Sensors in LTCC-technology with embedded microfluidic features, for medical applications. Proceedings of the IEEE 2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA), Turin, Italy.","DOI":"10.1109\/MeMeA.2015.7145237"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/5\/1189\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T12:37:20Z","timestamp":1760186240000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/5\/1189"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,3,8]]},"references-count":43,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2019,3]]}},"alternative-id":["s19051189"],"URL":"https:\/\/doi.org\/10.3390\/s19051189","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,3,8]]}}}