{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T21:20:27Z","timestamp":1791408027242,"version":"4.3.3"},"reference-count":32,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2019,4,1]],"date-time":"2019-04-01T00:00:00Z","timestamp":1554076800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100002649","name":"Yeungnam University","doi-asserted-by":"publisher","award":["218A580040"],"award-info":[{"award-number":["218A580040"]}],"id":[{"id":"10.13039\/501100002649","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100003052","name":"Ministry of Trade, Industry and Energy","doi-asserted-by":"publisher","award":["N0001364"],"award-info":[{"award-number":["N0001364"]}],"id":[{"id":"10.13039\/501100003052","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>An accurate method for detecting vital signs obtained from a Doppler radar sensor is proposed. A Doppler radar sensor can remotely obtain vital signs such as heartbeat and respiration rate, but the vital signs obtained by using the sensor do not show clear peaks like in electrocardiography (ECG) because of the operating characteristics of the radar. The proposed peak detection algorithm extracts the vital signs from the raw data. The algorithm shows the mean accuracy of 96.78% compared to the peak count from the reference ECG sensor and a processing time approximately two times faster than the gradient-based algorithm. To verify whether heart rate variability (HRV) analysis similar to that with an ECG sensor is possible for a radar sensor when applying the proposed method, the continuous parameter variations of the HRV in the time domain are analyzed using data processed with the proposed peak detection algorithm. Experimental results with six subjects show that the proposed method can obtain the heart rate with high accuracy but cannot obtain the information for an HRV analysis because the proposed method cannot overcome the characteristics of the radar sensor itself.<\/jats:p>","DOI":"10.3390\/s19071575","type":"journal-article","created":{"date-parts":[[2019,4,2]],"date-time":"2019-04-02T03:21:26Z","timestamp":1554175286000},"page":"1575","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":62,"title":["Peak Detection Algorithm for Vital Sign Detection Using Doppler Radar Sensors"],"prefix":"10.3390","volume":"19","author":[{"given":"Ju-Yeon","family":"Kim","sequence":"first","affiliation":[{"name":"Department of Electronic Engineering, Yeungnam University, Gyeongsan, Gyeongbuk-do 38541, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jae-Hyun","family":"Park","sequence":"additional","affiliation":[{"name":"Department of Electronic Engineering, Yeungnam University, Gyeongsan, Gyeongbuk-do 38541, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Se-Young","family":"Jang","sequence":"additional","affiliation":[{"name":"Department of Life Science, Yeungnam University, Gyeongsan, Gyeongbuk-do 38541, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4939-3274","authenticated-orcid":false,"given":"Jong-Ryul","family":"Yang","sequence":"additional","affiliation":[{"name":"Department of Electronic Engineering, Yeungnam University, Gyeongsan, Gyeongbuk-do 38541, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2019,4,1]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1016\/S0001-4575(02)00007-6","article-title":"Driver risk factors for sleep-related crashes","volume":"25","author":"Stutts","year":"2003","journal-title":"Accid. Anal. Prev."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"16937","DOI":"10.3390\/s121216937","article-title":"Detecting Driver Drowsiness Based on Sensors: A Review","volume":"12","author":"Sahayadha","year":"2012","journal-title":"Sensors"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1259","DOI":"10.1080\/00140139.2018.1482373","article-title":"The effects of physical vibration on heart rate variability as a measure of drowsiness","volume":"61","author":"Zhang","year":"2018","journal-title":"Ergonomics"},{"key":"ref_4","unstructured":"Brown, T., Lee, J., Schwarz, C., Dary Fiorentino, D., and McDonald, A. (2018, December 24). Assessing the feasibility of vehicle-based sensors to detect drowsy driving, Available online: https:\/\/www.nhtsa.gov\/sites\/nhtsa.dot.gov\/files\/811886-assess_veh-based_sensors_4_drowsy-driving_detection.pdf."},{"key":"ref_5","first-page":"1000213","article-title":"Simultaneous Measurement of Heart Rate Variability and Blinking Duration to Predict Sleep Onset and Drowsiness in Drivers","volume":"4","author":"Noda","year":"2015","journal-title":"J. Sleep Disord. Ther."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"520","DOI":"10.2486\/indhealth.45.520","article-title":"Use of Subjective and Physiological Indicators of Sleepiness to Predict Performance during a Vigilance Task","volume":"45","author":"Kaida","year":"2007","journal-title":"Ind. Health"},{"key":"ref_7","unstructured":"Rodriguez-Iba\u00f1ez, N., Garc\u00eda-Gonzalez, M., Aurora-Filigran, M., Fern\u00e1ndez-Chimeno, M., and Ramos-Castro, J. (2012, January 9\u201312). Changes in Heart Rate Variability Indexes due to Drowsiness in Professional Drivers Measured in a Real Environment. Proceedings of the 2012 Computing in Cardiology, Krakow, Poland."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Michail, E., Kokonozi, A., Chouvarda, L., and Maglaveras, N. (2008, January 20\u201324). EEG and HRV markers of sleepiness and loss of control during car driving. Proceedings of the 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vancouver, BC, Canada.","DOI":"10.1109\/IEMBS.2008.4649724"},{"key":"ref_9","unstructured":"Kryger, M., Roth, T., and Dement, W. (2011). Principles and Practice of Sleep Medicine, Elsevier Saunders. [5th ed.]."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1016\/S0987-7053(01)00289-1","article-title":"Human alpha ocsillations in wakefulness, drowsiness period, and REM sleep: Different electroencephalographic phenomena within the alpha band","volume":"32","author":"Cantero","year":"2002","journal-title":"Neurophysiol. Clin."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1932","DOI":"10.1109\/JBHI.2014.2305403","article-title":"An Innovative Nonintrusive Driver Assistance System for Vital Signal Monitoring","volume":"18","author":"Sun","year":"2014","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1016\/j.cmpb.2015.12.008","article-title":"ECG-based heartbeat classification for arrhythmia detection: A survey","volume":"127","author":"Luz","year":"2016","journal-title":"Comput. Methods Programs Biomed."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1031","DOI":"10.1007\/s11517-006-0119-0","article-title":"Heart rate variability: A review","volume":"44","author":"Acharya","year":"2006","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Das, S., Mukherjee, S., Chatterjee, S., and Chatterjee, H.K. (2016, January 20\u201322). Noise Elimination and ECG R peak detection using wavelet transform. Proceedings of the IEEE 7th Annual Ubiquitous Computing, Electronics & Mobile Communication Conference, New York, NY, USA.","DOI":"10.1109\/UEMCON.2016.7777876"},{"key":"ref_15","unstructured":"Rodr\u00edguez-Ib\u00e1\u00f1ez, N., Garc\u00eda-Gonz\u00e1lez, M.A., Fern\u00e1ndez-Chimeno, M., and Ramos-Castro, J. (September, January 30). Drowsiness Detection by Thoracic Effort Signal Analysis in Real Driving Environment. Proceedings of the 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Boston, MA, USA."},{"key":"ref_16","unstructured":"Boric-Lubecke, O., Lubecke, V.M., Host-Madsen, A., Samardzija, D., and Cheung, K. (2005, January 28\u201330). Doppler Radar Sensing of Multiple Subjects in Single and Multiple Antenna Systems. Proceedings of the 2005 IEEE 7th International Conference on Telecommunication in Modern Satellite, Cable and Broadcasting Services, Nis, Serbia."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Rissacher, D., and Galy, D. (2015, January 23\u201325). Cardiac Radar for Biometric Identification using Nearest Neighbour of Continuous Wavelet Transform Peaks. Proceedings of the IEEE International Conference on Identity, Security and Behavior Analysis, Hong Kong, China.","DOI":"10.1109\/ISBA.2015.7126356"},{"key":"ref_18","unstructured":"Mader, S.S., and Windelspecht, M. (2012). Human Biology, McGraw Hill. [12th ed.]."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Boric-Lubecke, O., Lubecke, V.M., Droitcour, A.D., Park, B.K., and Singh, A. (2016). Doppler Radar Physiological Sensing, John Wiley.","DOI":"10.1002\/9781119078418"},{"key":"ref_20","first-page":"3974","article-title":"Simplified real-time heartbeat detection in ballistocardiography using a dispersion-maximum method","volume":"28","author":"Choe","year":"2017","journal-title":"Biomed. Res."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Ye, C., Toyoda, K., and Ohtsuki, T. (2018, January 20\u201324). Robust heartbeat detection with Doppler radar based on stochastic gradient approach. Proceedings of the IEEE International Conference on Communications, Kansas City, MO, USA.","DOI":"10.1109\/ICC.2018.8422997"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1016\/S0002-9149(77)80094-5","article-title":"Arrhythmias documented by 24 hour continuous electrocardiographic monitoring in 50 male medical students without apparent heart disease","volume":"39","author":"Brodsky","year":"1977","journal-title":"Am. J. Cardiol."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1161\/01.CIR.101.23.e215","article-title":"Components of a New Research Resource for Complex Physiologic Signals","volume":"101","author":"Goldberger","year":"2000","journal-title":"Circulation"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"235","DOI":"10.30773\/pi.2017.08.17","article-title":"Stress and Heart Rate Variability: A Meta-Analysis and Review of the Literature","volume":"15","author":"Kim","year":"2018","journal-title":"Psychiatry Investig."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1536\/ihj.49.175","article-title":"Is 5-Minute Heart Rate Variability a Useful Measure for Monitoring the Autonomic Nervous System of Workers?","volume":"49","author":"Min","year":"2008","journal-title":"Int. Heart J."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Flores, M.J., Armingol, J.M., and Escalera, A. (2008, January 4\u20136). Real-Time Drowsiness Detection System for an Intelligent Vehicle. Proceedings of the 2008 IEEE Intelligent Vehicles Symposium, Eindhoven, The Netherlands.","DOI":"10.1109\/IVS.2008.4621125"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1315","DOI":"10.5664\/jcsm.3278","article-title":"The Accuracy of Eyelid Movement Parameters for Drowsiness Detection","volume":"9","author":"Wilkinson","year":"2013","journal-title":"J. Clin. Sleep Med."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1073","DOI":"10.1109\/TMTT.2007.895653","article-title":"Arctanget Demodulation With DC Offset Compensation in Quadrature Doppler Radar Receiver Systems","volume":"55","author":"Park","year":"2007","journal-title":"IEEE Trans. Microw. Theory Tech."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"574","DOI":"10.1109\/JSEN.2011.2124454","article-title":"Dual-Frequency Technique for Assessment of Cardiopulmonary Effective RCS and Displacement","volume":"12","author":"Kiriazi","year":"2012","journal-title":"IEEE Sens. J."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1007\/BF02442818","article-title":"Microprocessor-based cardiopulmonary rate monitor","volume":"25","author":"Chan","year":"1987","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"2542","DOI":"10.1109\/TMTT.2009.2029716","article-title":"Assessment of Heart Rate Variability and Respiratory Sinus Arrhythmia via Doppler Radar","volume":"57","author":"Massagram","year":"2009","journal-title":"IEEE Trans. Microw. Theory Tech."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"143702","DOI":"10.1063\/1.4917221","article-title":"Time delay between cardiac and brain activity during sleep transitions","volume":"106","author":"Long","year":"2015","journal-title":"Appl. Phys. Lett."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/7\/1575\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T12:42:05Z","timestamp":1760186525000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/7\/1575"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,4,1]]},"references-count":32,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2019,4]]}},"alternative-id":["s19071575"],"URL":"https:\/\/doi.org\/10.3390\/s19071575","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,4,1]]}}}