{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,4]],"date-time":"2025-11-04T16:06:52Z","timestamp":1762272412104,"version":"build-2065373602"},"reference-count":18,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2019,4,6]],"date-time":"2019-04-06T00:00:00Z","timestamp":1554508800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>In this paper, we propose an averaging pixel current adjustment technique for reducing fixed pattern noise (FPN) in the bolometer-type uncooled infrared image sensor. The averaging pixel current adjustment technique is composed of active pixel, reference pixel, and calibration circuit. Polysilicon resistors were used in each active pixel and reference pixel. Resistance deviation among active pixels integrated with the same resistance value cause FPN. The principle of the averaging pixel current adjustment technique for removing FPN is based on the subtraction of dark current of the active pixel from the dark current of the reference pixel. The subtracted current is converted into the voltage, which contains pixel calibration information. The calibration circuit is used to adjust the calibration current. After calibration, the nano-ampere current is output with small deviation. The proposed averaging pixel current adjustment technique is implemented by a chip composed of a pixel array, a calibration circuit, average current generators, and readout circuits. The chip was fabricated using a standard 0.35 \u03bcm CMOS process and its performance was evaluated.<\/jats:p>","DOI":"10.3390\/s19071653","type":"journal-article","created":{"date-parts":[[2019,4,8]],"date-time":"2019-04-08T11:54:52Z","timestamp":1554724492000},"page":"1653","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Averaging Pixel Current Adjustment Technique for Reducing Fixed Pattern Noise in the Bolometer-Type Uncooled Infrared Image Sensor"],"prefix":"10.3390","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8456-6903","authenticated-orcid":false,"given":"Sang-Hwan","family":"Kim","sequence":"first","affiliation":[{"name":"School of Electronics Engineering, Kyungpook National University, Daegu 41566, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Byoung-Soo","family":"Choi","sequence":"additional","affiliation":[{"name":"School of Electronics Engineering, Kyungpook National University, Daegu 41566, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jimin","family":"Lee","sequence":"additional","affiliation":[{"name":"School of Electronics Engineering, Kyungpook National University, Daegu 41566, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Junwoo","family":"Lee","sequence":"additional","affiliation":[{"name":"School of Electronics Engineering, Kyungpook National University, Daegu 41566, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jewon","family":"Lee","sequence":"additional","affiliation":[{"name":"School of Electronics Engineering, Kyungpook National University, Daegu 41566, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jae-Hyoun","family":"Park","sequence":"additional","affiliation":[{"name":"Korea Electronics Technology Institute, Seongnam-si 13509, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kyoung-Il","family":"Lee","sequence":"additional","affiliation":[{"name":"Korea Electronics Technology Institute, Seongnam-si 13509, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0469-1676","authenticated-orcid":false,"given":"Jang-Kyoo","family":"Shin","sequence":"additional","affiliation":[{"name":"School of Electronics Engineering, Kyungpook National University, Daegu 41566, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2019,4,6]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1109\/LPT.2018.2792491","article-title":"Uncooled Infrared Micro-Bolometer FPA for Multiple Digital Correlated Double Sampling","volume":"30","author":"Kim","year":"2018","journal-title":"IEEE Photonics Tec. Lett."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1117\/12.321756","article-title":"Low Cost 160 \u00d7 128 uncooled infrared sensor array","volume":"3360","author":"Parish","year":"1998","journal-title":"Proc. SPIE"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"2593","DOI":"10.3390\/s18082593","article-title":"Experiments on Temperature Changes of Microbolometer under Blackbody Radiation and Predictions Using Thermal Modeling by COMSOL Multiphysics Simulator","volume":"18","author":"Deng","year":"2018","journal-title":"Sensors"},{"key":"ref_4","unstructured":"Liu, D., Fang, Z., Lu, W., Chen, Z., and Zhang, Y. (2016, January 25\u201328). A Low-Power Low-Noise 160 \u00d7 120 17 \u00b5m Pixel Pitch TEC-Less Uncooled Infrared Image Sensor. Proceedings of the 2016 13th IEEE International Conference on Solid-State and Integrated Circuit Technology, Hangzhou, China."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1533","DOI":"10.1109\/JSEN.2014.2298512","article-title":"Uncooled microbolometer infrared focal plane array without substrate temperature stabilization","volume":"14","author":"Lv","year":"2014","journal-title":"IEEE Sens. J."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1247","DOI":"10.1109\/LPT.2015.2413676","article-title":"An uncooled infrared microbolometer array for low-cost applications","volume":"27","author":"Shen","year":"2015","journal-title":"IEEE Photonics Technol. Lett."},{"key":"ref_7","unstructured":"Dupont, B., Dupret, A., Becker, S., Hamelin, A., Guellec, F., Imperinetti, P., and Rabaud, W. (2013, January 17\u201321). A [10 \u00b0C; 70 \u00b0C] 640 \u00d7 480 17 \u00b5m Pixel Pitch TEC-Less IR Bolometer Imager with Below 50 mK and Below 4 V Power Supply. Proceedings of the 2013 IEEE International Solid-State Circuits Conference Digest of Technical Papers, San Francisco, CA, USA."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Hu, B., Li, P., Ruan, A.W., and Lin, D.M. (2011, January 21\u201323). Design and verification of 160 \u00d7 120 bolometer ROIC. Proceedings of the 2011 International Conference on Computational Problem-Solving (ICCP), Chengdu, China.","DOI":"10.1109\/ICCPS.2011.6092228"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Park, S., Cho, T., Kim, M., Park, H., and Lee, K. (2017, January 5\u20138). A shutter-less micro-bolometer thermal imaging system using multiple digital correlated double sampling for mobile applications. Proceedings of the 2017 Symposium on VLSI Circuits, Kyoto, Japan.","DOI":"10.23919\/VLSIC.2017.8008577"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Sizov, F., Reva, V., Golenkov, O., Petriakov, V., Shevchik-Shekera, A., Korinets, S., Sakhno, M., Lysiuk, I., Zabudsky, V., and Bunchuk, S. (2014, January 16\u201318). THz\/sub-THz direct detector challenges: Rectification and thermal detectors for active imaging. Proceedings of the 2014 20th International Conference on Microwaves, Radar and Wireless Communications (MIKON), Gdansk, Poland.","DOI":"10.1109\/MIKON.2014.6899989"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"6217","DOI":"10.1109\/JSEN.2018.2844864","article-title":"A Test Platform for the Noise Characterization of","volume":"18","author":"Roics","year":"2018","journal-title":"IEEE Sens. J."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1048","DOI":"10.1109\/TCSII.2015.2455391","article-title":"An Analog Front-End IC Design for 320 \u00d7 240 Microbolometer Array Applications","volume":"62","author":"Seo","year":"2015","journal-title":"IEEE Trans. CIRCUITS Syst."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1207","DOI":"10.1109\/JSEN.2012.2230621","article-title":"Model-Based Low-Noise Readout Integrated Circuit Design for Uncooled Microbolometers","volume":"13","author":"Lv","year":"2013","journal-title":"IEEE Sens. J."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"350","DOI":"10.1109\/TTHZ.2018.2819502","article-title":"Low-Noise Readout Integrated Circuit for Terahertz Array Detector","volume":"8","author":"Jiang","year":"2018","journal-title":"IEEE Trans. Terahertz Sci. Technol."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Seo, J., Kim, G., Lim, K., Seok, C., Kim, H., Im, S., Kim, J., Kim, C., and Ko, H. (2013, January 20\u201323). An analog front-end IC with regulated R-I amplifier and CDS CTIA for microbolometer. Proceedings of the 2013 13th International Conference on Control, Automation and Systems, Gwangju, Korea.","DOI":"10.1109\/ICCAS.2013.6704156"},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Ye, M., Zhao, G., Li, Y., and Zhao, Y. (2019). An Analog-Front ROIC with On-Chip Non-Uniformity Compensation for Diode-Based Infrared Image Sensors. Sensors, 19.","DOI":"10.3390\/s19020298"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"2861","DOI":"10.1109\/TNS.2006.881096","article-title":"A Front-End Readout for Micro Bolometers Having Sub Nano Volt Noise Floor","volume":"53","author":"Arnaboldi","year":"2006","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Kim, K.-D., Park, S., Yoon, K.-S., Kang, G.-G., Han, H.-K., Choi, J.-S., Ko, M.-W., Cho, J., Lim, S., and Lee, H.-M. (2018, January 11\u201315). A 100mK-NETD 100ms-Startup-Time 80 \u00d7 60 Micro- Bolometer CMOS Thermal Imager Integrated with a 0.234 mm2 1.89 \u03bcVrms Noise 12b Biasing DAC. Proceedings of the 2018 IEEE International Solid-State Circuits Conference, San Francisco, CA, USA.","DOI":"10.1109\/ISSCC.2018.8310249"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/7\/1653\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T12:43:26Z","timestamp":1760186606000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/7\/1653"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,4,6]]},"references-count":18,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2019,4]]}},"alternative-id":["s19071653"],"URL":"https:\/\/doi.org\/10.3390\/s19071653","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2019,4,6]]}}}