{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T17:46:57Z","timestamp":1781113617942,"version":"3.54.1"},"reference-count":20,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2019,4,11]],"date-time":"2019-04-11T00:00:00Z","timestamp":1554940800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["17K12778"],"award-info":[{"award-number":["17K12778"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The further exploration of the capacitive ECG (cECG) is hindered by frequent fluctuations in signal quality from body movement and changes in sleep position. The processing framework must be fundamentally adapted to make full use of this signal. Therefore, we propose a new signal-processing framework that determines the signal quality for short signal segments (2 and 4 seconds) using a multi-class classification model (qua_model) based on a convolutional neural network (CNN). We built another independent deep CNN classifier (pos_model) to classify the sleep position. In the validation, 12 subjects were recruited for a 30-minute experiment, which required the subjects to lie on a bed in different sleeping positions. The short segments, classified as clear (C1 class) by the qua_model, were used to determine sleep positions with the pos_model. In 10-fold cross-validation, the qua_model for signals of 4-second length could recognize the signal of the C1 class at a 0.99 precision and a 0.99 recall; the pos_model could recognize the supine sleep position, the left, and right lateral sleep positions at a 0.99 averaged precision and a 0.99 averaged recall. Given the amount of data accumulated per night and the instability in the signal quality, this fully automatic processing framework is indispensable for a personal healthcare system. Therefore, this study could serve as an important step for cECG technique trying to explore the cECG for unconstrained heart monitoring.<\/jats:p>","DOI":"10.3390\/s19071731","type":"journal-article","created":{"date-parts":[[2019,4,12]],"date-time":"2019-04-12T03:46:37Z","timestamp":1555040797000},"page":"1731","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":39,"title":["A Novel CNN-Based Framework for Classification of Signal Quality and Sleep Position from a Capacitive ECG Measurement"],"prefix":"10.3390","volume":"19","author":[{"given":"Koshiro","family":"Kido","sequence":"first","affiliation":[{"name":"Division of Information Science, Nara Institute of Science and Technology, Ikoma 630-0192, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8514-4200","authenticated-orcid":false,"given":"Toshiyo","family":"Tamura","sequence":"additional","affiliation":[{"name":"Future Robotics Organization, Waseda University, Tokorozawa 359-1192, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naoaki","family":"Ono","sequence":"additional","affiliation":[{"name":"Division of Information Science, Nara Institute of Science and Technology, Ikoma 630-0192, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"MD.","family":"Altaf-Ul-Amin","sequence":"additional","affiliation":[{"name":"Division of Information Science, Nara Institute of Science and Technology, Ikoma 630-0192, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masaki","family":"Sekine","sequence":"additional","affiliation":[{"name":"Department of Medical care Technology, Tsukuba International University, Tsuchiura 300-0051, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shigehiko","family":"Kanaya","sequence":"additional","affiliation":[{"name":"Division of Information Science, Nara Institute of Science and Technology, Ikoma 630-0192, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ming","family":"Huang","sequence":"additional","affiliation":[{"name":"Division of Information Science, Nara Institute of Science and Technology, Ikoma 630-0192, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2019,4,11]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Barrett, P.M., Komatireddy, R., Haaser, S., Topol, S., Sheard, J., Encinas, J., Fought, A.J., and Topol, E.J. (2014). Comparison of 24-hour Holter monitoring with 14-day novel adhesive patch electrocardiographic monitoring. Am. J. Med., 127.","DOI":"10.1016\/j.amjmed.2013.10.003"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1136\/hrt.2003.019323","article-title":"Clinical relevance of arrhythmias during sleep: Guidance for clinicians","volume":"90","author":"Gula","year":"2004","journal-title":"Heart"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"201","DOI":"10.2174\/1874120701004010201","article-title":"Theory and Developments in an Unobtrusive Cardiovascular System Representation: Ballistocardiography","volume":"4","author":"Pinheiro","year":"2010","journal-title":"Open Biomed. Eng. J."},{"key":"ref_4","first-page":"753","article-title":"Smart detection of atrial fibrillation","volume":"19","author":"Krivoshei","year":"2016","journal-title":"Europace"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1016\/0002-9149(91)90739-8","article-title":"Early prediction of acute myocardial infarction from clinical history, examination and electrocardiogram in the emergency room","volume":"68","author":"Karlson","year":"1991","journal-title":"Am. J. Cardiol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1805","DOI":"10.1007\/s10439-008-9553-5","article-title":"Online digital filter and QRS detector applicable in low resource ECG monitoring systems","volume":"36","author":"Tabakov","year":"2008","journal-title":"Ann. Biomed. Eng."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1016\/j.gheart.2016.12.003","article-title":"Feasibility of Using Mobile ECG Recording Technology to Detect Atrial Fibrillation in Low-Resource Settings","volume":"12","author":"Evans","year":"2017","journal-title":"Glob. Heart"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"759","DOI":"10.1109\/TBME.2006.889201","article-title":"Capacitive sensing of electrocardiographic potential through cloth from the dorsal surface of the body in a supine position: A preliminary study","volume":"54","author":"Ueno","year":"2007","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"11295","DOI":"10.3390\/s150511295","article-title":"Heart rate variability monitoring during sleep based on capacitively coupled textile electrodes on a bed","volume":"15","author":"Lee","year":"2015","journal-title":"Sensors"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"618","DOI":"10.1109\/JBHI.2018.2825020","article-title":"Noncontact In-Bed Measurements of Physiological and Behavioral Signals Using an Integrated Fabric-Sheet Sensing Scheme","volume":"23","author":"Takano","year":"2018","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1660","DOI":"10.1109\/TBME.2013.2240452","article-title":"ECG signal quality during arrhythmia and its application to false alarm reduction","volume":"60","author":"Behar","year":"2013","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_12","first-page":"832","article-title":"Signal-Quality Indices for the Electrocardiogram and Photoplethysmogram: Derivation and Applications to Wireless Monitoring","volume":"19","author":"Orphanidou","year":"2015","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Castro, D.I., Varon, C., Torfs, T., Van Huffel, S., Puers, R., and Van Hoof, C. (2018). Evaluation of a Multichannel Non-Contact ECG System and Signal Quality Algorithms for Sleep Apnea Detection and Monitoring. Sensors, 18.","DOI":"10.3390\/s18020577"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1109\/TBME.2015.2468589","article-title":"Real-Time Patient-Specific ECG Classification by 1-D Convolutional Neural Networks","volume":"63","author":"Kiranyaz","year":"2016","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1285","DOI":"10.1109\/TMI.2016.2528162","article-title":"Deep Convolutional Neural Networks for Computer-Aided Detection: CNN Architectures, Dataset Characteristics and Transfer Learning","volume":"35","author":"Shin","year":"2016","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1240","DOI":"10.1109\/TMI.2016.2538465","article-title":"Brain tumor segmentation using convolutional neural networks in MRI images","volume":"35","author":"Pereira","year":"2016","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Rundo, F., Conoci, S., Ortis, A., and Battiato, S. (2018). An Advanced Bio-Inspired PhotoPlethysmoGraphy (PPG) and ECG Pattern Recognition System for Medical Assessment. Sensors, 18.","DOI":"10.3390\/s18020405"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"He, K., Zhang, X., Ren, S., and Sun, J. (2016, January 27\u201330). Deep Residual Learning for Image Recognition. Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition, Las Vegas, NV, USA.","DOI":"10.1109\/CVPR.2016.90"},{"key":"ref_19","unstructured":"Ioffe, S., and Szegedy, C. (arXiv, 2015). Batch normalization: Accelerating deep network training by reducing internal covariate shift, arXiv."},{"key":"ref_20","unstructured":"Makhzani, A., Shlens, J., Jaitly, N., Goodfellow, I., and Frey, B. (arXiv, 2015). Adversarial autoencoders, arXiv."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/7\/1731\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T12:44:34Z","timestamp":1760186674000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/7\/1731"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,4,11]]},"references-count":20,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2019,4]]}},"alternative-id":["s19071731"],"URL":"https:\/\/doi.org\/10.3390\/s19071731","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,4,11]]}}}