{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,11]],"date-time":"2026-11-11T22:14:00Z","timestamp":1794435240158,"version":"4.9.1"},"reference-count":24,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2019,5,2]],"date-time":"2019-05-02T00:00:00Z","timestamp":1556755200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["1777017"],"award-info":[{"award-number":["1777017"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"name":"National Key R&amp;D Program of China","award":["2017YFC0601804"],"award-info":[{"award-number":["2017YFC0601804"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The grounding grid is critical to the safety and stability of a power system. Corrosive cracking of the grounding conductor is the main cause of deterioration of grounding grid performance. Existing fault diagnosis methods for grounding grids are limited by the number and distribution of grounding leads, and some of them cannot be used for online detection. This paper proposes a grounding grid detection method based on magnetic source excitation. The measuring device consists of four coils, two horizontal excitation coils, and two vertical receiving coils. The secondary magnetic field signal is extracted from the primary field and the background field by properly positioning the coils, such that the measured signal can reflect the underground media more accurately. The measuring device of the method is portable, the measurement process is contactless with the grounding grid, and it is not limited by the grounding leads. Furthermore, it has a strong anti-interference ability and can realize online detection. It was proven by simulations and experiments that the proposed method has a higher measurement accuracy and stronger anti-interference ability when compared with existing methods. This paper also discusses the influence of various factors such as the number and the location of the breakpoints, the frequency of the excitation source, the soil resistivity, and stratification from the measurement data. It was proven that the method has high precision and a wide application range, and is important for guiding significance and reference value in engineering applications.<\/jats:p>","DOI":"10.3390\/s19092046","type":"journal-article","created":{"date-parts":[[2019,5,2]],"date-time":"2019-05-02T03:15:22Z","timestamp":1556766922000},"page":"2046","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":30,"title":["A Non-Destructive Testing Method for Fault Detection of Substation Grounding Grids"],"prefix":"10.3390","volume":"19","author":[{"given":"Xiujuan","family":"Wang","sequence":"first","affiliation":[{"name":"School of Electrical Engineering, Chongqing University, State Key Laboratory of Power Transmission Equipment and System Security, Chongqing 400044, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhihong","family":"Fu","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering, Chongqing University, State Key Laboratory of Power Transmission Equipment and System Security, Chongqing 400044, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yao","family":"Wang","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering, Chongqing University, State Key Laboratory of Power Transmission Equipment and System Security, Chongqing 400044, China"},{"name":"Chongqing Triloop Prospecting Technology Co. Ltd., Chongqing 402660, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Renkuan","family":"Liu","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering, Chongqing University, State Key Laboratory of Power Transmission Equipment and System Security, Chongqing 400044, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lin","family":"Chen","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering, Chongqing University, State Key Laboratory of Power Transmission Equipment and System Security, Chongqing 400044, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2019,5,2]]},"reference":[{"key":"ref_1","unstructured":"(2000). IEEE Guide for Safety in AC Substation Grounding. IEEE Stand., 1\u2013192."},{"key":"ref_2","unstructured":"(2012). IEEE Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials of a Grounding System. IEEE Stand., 1\u201386."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"761","DOI":"10.1109\/TSG.2011.2175456","article-title":"Online Monitoring of Substation Grounding Grid Conditions Using Touch and Step Voltage Sensors","volume":"3","author":"Long","year":"2012","journal-title":"IEEE Trans. Smart Grid."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1886","DOI":"10.1109\/TPWRD.2005.848632","article-title":"Current North American Assessment and Refurbishment Practices of Substation Grounding Systems","volume":"20","author":"Gillies","year":"2005","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1918","DOI":"10.1109\/TPAS.1981.316535","article-title":"Application of a Digital Signal Analyzer to The Measurement of Power System Ground Impedances","volume":"100","author":"Lu","year":"1981","journal-title":"IEEE Trans. Power Appar. Syst."},{"key":"ref_6","first-page":"3215","article-title":"In Impedance Measurement of Grounding Systems with Alternative Fall-of-potential Method","volume":"5","author":"Dimcev","year":"2000","journal-title":"IEEE Ind. Appl. Conf."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"739","DOI":"10.1109\/61.956764","article-title":"Influence of Inductive Coupling between Leads on Ground Impedance Measurements Using The Fall-of-Potential Method","volume":"16","author":"Ma","year":"2001","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"881","DOI":"10.1109\/TPWRD.2002.803738","article-title":"Extended Analysis of Ground Impedance Measurement Using the Fall-of-Potential Method","volume":"17","author":"Ma","year":"2002","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1250","DOI":"10.1109\/TPWRD.2005.860245","article-title":"Computation of Ground Resistances and Assessment of Ground Grid Safety at 161\/23.9-kV Indoor-Type Substation","volume":"21","author":"Chang","year":"2006","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1109\/TPWRD.2006.870980","article-title":"Novel Measurement System for Grounding Impedance of Substation","volume":"21","author":"Zeng","year":"2006","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1954","DOI":"10.1109\/TPWRS.2008.923812","article-title":"Improved Methodology for High-Frequency Low-Current Measurement of Grounding Rod Impedance","volume":"23","author":"Llovera","year":"2008","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"788","DOI":"10.1109\/TPWRD.2003.813895","article-title":"Seasonal Influences on Safety of Substation Grounding System","volume":"18","author":"He","year":"2003","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1109\/TPWRD.2013.2240704","article-title":"Fault Current-Division Factor of Substation Grounding Grid in Seasonal Frozen Soil","volume":"28","author":"He","year":"2013","journal-title":"IEEE Trans. Power Del."},{"key":"ref_14","unstructured":"Hu, J., Zeng, R., He, J., Sun, W., Yao, J., and Su, Q. (2000, January 4\u20137). Novel Method of Corrosion Diagnosis for Grounding Grid. Proceedings of the 2000 International Conference on Power System Technology (PowerCon 2000), Perth, Australia."},{"key":"ref_15","unstructured":"Zeng, R., He, J., Hu, J., Lu, G., and Luo, B. (2002, January 13\u201318). The Theory and Implementation of Corrosion Diagnosis for Grounding System. Proceedings of the Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting, Pittsburgh, PA, USA."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1109\/20.996125","article-title":"Diagnosis of breaks in substation\u2019s grounding grid by using the electromagnetic method","volume":"38","author":"Zhang","year":"2002","journal-title":"IEEE Trans. Magn."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Ma, Y. (2009, January 4\u20136). Investigating Grounding Grid Integrity Based on The Current Injection Method. Proceedings of the 41st North American Power Symposium, Starkville, MS, USA.","DOI":"10.1109\/NAPS.2009.5484048"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"63","DOI":"10.2478\/v10178-012-0005-z","article-title":"A Fault Diagnosis Method for Substation Grounding Grid Based on the Square-Wave Frequency Domain Model","volume":"19","author":"Zhang","year":"2012","journal-title":"Metrol. Meas. Syst."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1109\/TIM.1983.4315120","article-title":"Metal detector for tracing submarine telecommunication cables","volume":"32","author":"Asakawa","year":"1983","journal-title":"IEEE Trans. Instr. Meas."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"6475","DOI":"10.1109\/TIE.2017.2682033","article-title":"Configuration Detection of Substation Grounding Grid Using Transient Electromagnetic Method","volume":"64","author":"Yu","year":"2017","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_21","first-page":"19","article-title":"Integrated Analysis Software for Grounding, EMF, and EMI","volume":"2","author":"Farid","year":"1993","journal-title":"IEEE Comput. Appl. Power"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1109\/TPWRD.1986.4308036","article-title":"Electromagnetic fields generated by overhead and buried short conductors, part 1\u2013single conductors","volume":"4","author":"Dawalibi","year":"1986","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1109\/TPWRD.1986.4308037","article-title":"Electromagnetic fields generated by overhead and buried short conductors, part 2\u2013ground networks","volume":"4","author":"Dawalibi","year":"1986","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1181","DOI":"10.1109\/TMAG.2007.892283","article-title":"Grounding Performance Analysis of the Substation Grounding Grids by Finite Element Method in Frequency Domain","volume":"43","author":"Qi","year":"2007","journal-title":"IEEE Trans. Magn."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/9\/2046\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T12:48:43Z","timestamp":1760186923000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/9\/2046"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,5,2]]},"references-count":24,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2019,5]]}},"alternative-id":["s19092046"],"URL":"https:\/\/doi.org\/10.3390\/s19092046","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,5,2]]}}}