{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T12:42:43Z","timestamp":1780317763173,"version":"3.54.1"},"reference-count":27,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2019,5,5]],"date-time":"2019-05-05T00:00:00Z","timestamp":1557014400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>In order to improve the practice in maintenance of power cables, this paper proposes a novel traveling-wave-based fault location method improved by unsupervised learning. The improvement mainly lies in the identification of the arrival time of the traveling wave. The proposed approach consists of four steps: (1) The traveling wave associated with the sheath currents of the cables are grouped in a matrix; (2) the use of dimensionality reduction by t-SNE (t-distributed Stochastic Neighbor Embedding) to reconstruct the matrix features in a low dimension; (3) application of the DBSCAN (density-based spatial clustering of applications with noise) clustering to cluster the sample points by the closeness of the sample distribution; (4) the arrival time of the traveling wave can be identified by searching for the maximum slope point of the non-noise cluster with the fewest samples. Simulations and calculations have been carried out for both HV (high voltage) and MV (medium voltage) cables. Results indicate that the arrival time of the traveling wave can be identified for both HV cables and MV cables with\/without noise, and the method is suitable with few random time errors of the recorded data. A lab-based experiment was carried out to validate the proposed method and helped to prove the effectiveness of the clustering and the fault location.<\/jats:p>","DOI":"10.3390\/s19092083","type":"journal-article","created":{"date-parts":[[2019,5,9]],"date-time":"2019-05-09T11:22:35Z","timestamp":1557400955000},"page":"2083","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":22,"title":["A Novel Traveling-Wave-Based Method Improved by Unsupervised Learning for Fault Location of Power Cables via Sheath Current Monitoring"],"prefix":"10.3390","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7048-4595","authenticated-orcid":false,"given":"Mingzhen","family":"Li","sequence":"first","affiliation":[{"name":"School of Electrical Engineering and Automation, Wuhan University, No. 299, Bayi Road, Wuchang District, Wuhan 430072, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianming","family":"Liu","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering and Automation, Wuhan University, No. 299, Bayi Road, Wuchang District, Wuhan 430072, China"},{"name":"Chinese Society for Electrical Engineering, No.1, Baiguang Road, Xuanwu District, Beijing 100761, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tao","family":"Zhu","sequence":"additional","affiliation":[{"name":"State Grid Hubei Electric Power Company, State Grid Corporation of China, No. 1701 Jiefang Avenue, Jiang\u2019an District, Wuhan 430013, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenjun","family":"Zhou","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering and Automation, Wuhan University, No. 299, Bayi Road, Wuchang District, Wuhan 430072, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chengke","family":"Zhou","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering and Automation, Wuhan University, No. 299, Bayi Road, Wuchang District, Wuhan 430072, China"},{"name":"School of Engineering and Built Environment, Glasgow Caledonian University, Cowcaddens Road, Glasgow G4 0BA, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2019,5,5]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"2207","DOI":"10.1109\/TLA.2018.8528236","article-title":"Faulted branch location in distribution networks based on the analysis of high- frequency transients","volume":"16","author":"Penaloza","year":"2018","journal-title":"IEEE Lat. Am. Trans."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1109\/MEI.2016.7528987","article-title":"Diagnosis and location of faults in submarine power cables","volume":"32","author":"Bawart","year":"2016","journal-title":"IEEE Electr. Insul. Mag."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1016\/S0022-0396(03)00170-0","article-title":"Existence, uniqueness and exponential stability of traveling wave solutions of some integral differential equations arising from neuronal networks","volume":"197","author":"Zhang","year":"2017","journal-title":"J. Differ. Equ."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1109\/TPWRD.2016.2589265","article-title":"Traveling-wave-based fault-location algorithm for hybrid multiterminal circuits","volume":"32","author":"Hamidi","year":"2017","journal-title":"IEEE Tran. Power Deliv."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1016\/j.energy.2016.03.001","article-title":"An acoustically matched traveling-wave thermoacoustic generator achieving 750 W electric power","volume":"103","author":"Wang","year":"2016","journal-title":"Energy"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1109\/61.484009","article-title":"Unsynchronized two-terminal fault location estimation","volume":"11","author":"Novosel","year":"1996","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Li, M., Zhou, C., Zhou, W., Wang, C., Yao, L., Su, M., and Huang, X. (2018). A novel fault location method for a cross-bonded HV cable system based on sheath current monitoring. Sensors, 18.","DOI":"10.3390\/s18103356"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Dashti, R., Salehizadeh, S., Shaker, H., and Tahavori, M. (2018). Fault Location in Double Circuit Medium Power Distribution Networks Using an Impedance-Based Method. Appl. Sci., 8.","DOI":"10.3390\/app8071034"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"2296","DOI":"10.1109\/TPWRD.2016.2551367","article-title":"Settings-free traveling-wave-based earth fault location using unsynchronized two-terminal data","volume":"31","author":"Lopes","year":"2016","journal-title":"IEEE Trans. Power Del."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"873","DOI":"10.1109\/TPWRD.2017.2711262","article-title":"Accurate two-terminal transmission line fault location using traveling waves","volume":"33","author":"Lopes","year":"2018","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_11","unstructured":"Lei, B., Xu, G., Feng, M., Zou, Y., Heijden, F., Ridder, D., and Tax, D. (2017). Unsupervised Learning. Classification, Parameter Estimation and State Estimation, JohnWiley & Sons, Ltd.. [2nd ed.]."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1266","DOI":"10.1109\/TIM.2018.2795178","article-title":"An unsupervised-learning-based approach for automated defect inspection on textured surfaces","volume":"67","author":"Mei","year":"2018","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Trogh, J., Joseph, W., Martens, L., and Plets, D. (2019). An unsupervised learning technique to optimize radio maps for indoor localization. Sensors, 19.","DOI":"10.3390\/s19040752"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"105043","DOI":"10.1088\/1367-2630\/11\/10\/105043","article-title":"Quantum filter reduction for measurement-feedback control via unsupervised manifold learning","volume":"11","author":"Nielsen","year":"2009","journal-title":"New J. Phys."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Saha, M.M., Izykowski, J., and Rosolowski, E. (2010). Fault Location on Power Networks, Springer.","DOI":"10.1007\/978-1-84882-886-5"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"847","DOI":"10.1109\/TDEI.2011.5931074","article-title":"Effect of tree channel conductivity on electrical tree shape and breakdown in XLPE cable insulation samples","volume":"18","author":"Chen","year":"2011","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_17","first-page":"2579","article-title":"Visualizing data using t-SNE","volume":"9","author":"Maaten","year":"2008","journal-title":"J. Mach. Learn. Res."},{"key":"ref_18","unstructured":"Ester, M., Kriegel, H., Sander, J., and Xu, X. (1996, January 4\u20138). A Density-Based Algorithm for Discovering Clusters in Large Spatial Databases with Noise. Proceedings of the 2nd ACM SIGKDD, Portland, Oregon."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"5376","DOI":"10.1109\/TIA.2015.2409802","article-title":"The feasibility of cable sheath fault detection by monitoring sheath-to-ground currents at the ends of cross-bonding sections","volume":"51","author":"Marzinotto","year":"2015","journal-title":"IEEE Trans. Ind. Appl."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Yang, Y., Hepburn, D.M., Zhou, C., Jiang, W., Yang, B., and Zhou, W. (2015, January 21\u221225). On-line Monitoring and Trending Analysis of Dielectric Losses in Cross-bonded High Voltage Cable Systems. Proceedings of the 9th International Conference on Insulated Power Cables, Paris, France.","DOI":"10.1109\/ICPADM.2015.7295268"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1049\/iet-gtd.2015.0899","article-title":"Critical aspects on wavelet transforms based fault identification procedures in HV transmission line","volume":"10","author":"Adly","year":"2015","journal-title":"IET Gener. Transm. Distri."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1016\/j.neucom.2016.08.021","article-title":"An investigation of rolling bearing early diagnosis based on high-frequency characteristics and self-adaptive wavelet de-noising","volume":"216","author":"Cui","year":"2016","journal-title":"Neurocomputing"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1109\/TEC.2015.2476835","article-title":"Wavelet packet decomposition-based fault diagnosis scheme for srm drives with a single current sensor","volume":"31","author":"Gan","year":"2016","journal-title":"IEEE Trans. Energy Convers."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1109\/TASSP.1976.1162830","article-title":"The generalized correlation method for estimation of time delay","volume":"24","author":"Knapp","year":"1976","journal-title":"IEEE Trans. Acoust. Speech Signal. Process."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1891","DOI":"10.1109\/TDEI.2012.6396945","article-title":"Partial discharge localization in transformers using uhf detection method","volume":"19","author":"Sinaga","year":"2012","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_26","first-page":"5","article-title":"Partial discharge monitoring of power transformers using UHF sensors. Part I: Sensors and signal interpretation","volume":"21","author":"Judd","year":"2005","journal-title":"IEEE Electr. Insul. Mag."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"9882","DOI":"10.3390\/s150509882","article-title":"Separation of radio-frequency sources and localization of partial discharges in noisy environments","volume":"15","author":"Robles","year":"2015","journal-title":"Sensors"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/9\/2083\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T12:49:15Z","timestamp":1760186955000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/9\/2083"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,5,5]]},"references-count":27,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2019,5]]}},"alternative-id":["s19092083"],"URL":"https:\/\/doi.org\/10.3390\/s19092083","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,5,5]]}}}