{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T16:24:00Z","timestamp":1783009440428,"version":"3.54.5"},"reference-count":40,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2019,5,13]],"date-time":"2019-05-13T00:00:00Z","timestamp":1557705600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100010661","name":"Horizon 2020 Framework Programme","doi-asserted-by":"publisher","award":["687795"],"award-info":[{"award-number":["687795"]}],"id":[{"id":"10.13039\/100010661","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Conventional myoelectric controllers provide a mapping between electromyographic signals and prosthetic functions. However, due to a number of instabilities continuously challenging this process, an initial mapping may require an extended calibration phase with long periods of user-training in order to ensure satisfactory performance. Recently, studies on co-adaptation have highlighted the benefits of concurrent user learning and machine adaptation where systems can cope with deficiencies in the initial model by learning from newly acquired data. However, the success remains highly dependent on careful weighting of these new data. In this study, we proposed a function driven directional forgetting approach to the recursive least-squares algorithm as opposed to the classic exponential forgetting scheme. By only discounting past information in the same direction of the new data, local corrections to the mapping would induce less distortion to other regions. To validate the approach, subjects performed a set of real-time myoelectric tasks over a range of forgetting factors. Results show that directional forgetting with a forgetting factor of 0.995 outperformed exponential forgetting as well as unassisted user learning. Moreover, myoelectric control remained stable after adaptation with directional forgetting over a range of forgetting factors. These results indicate that a directional approach to discounting past training data can improve performance and alleviate sensitivities to parameter selection in recursive adaptation algorithms.<\/jats:p>","DOI":"10.3390\/s19092203","type":"journal-article","created":{"date-parts":[[2019,5,13]],"date-time":"2019-05-13T11:00:57Z","timestamp":1557745257000},"page":"2203","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":18,"title":["Directional Forgetting for Stable Co-Adaptation in Myoelectric Control"],"prefix":"10.3390","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9760-0752","authenticated-orcid":false,"given":"Dennis","family":"Yeung","sequence":"first","affiliation":[{"name":"Department of Electrical Engineering and Automation, Aalto University, 02150 Espoo, Finland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7883-2697","authenticated-orcid":false,"given":"Dario","family":"Farina","sequence":"additional","affiliation":[{"name":"Department of Bioengineering, Imperial College London, London SW7 2AZ, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7394-9474","authenticated-orcid":false,"given":"Ivan","family":"Vujaklija","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering and Automation, Aalto University, 02150 Espoo, Finland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2019,5,13]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1302\/0301-620X.37B3.506","article-title":"The Use of Meyo-electric Currents in the Operation of Prostheses","volume":"37","author":"Battye","year":"1955","journal-title":"J. Bone Joint Surg."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1302\/0301-620X.47B3.411","article-title":"Myo-Electric Control of Powered Prostheses","volume":"47","author":"Bottomley","year":"1965","journal-title":"J. Bone Joint Surg."},{"key":"ref_3","first-page":"31","article-title":"New developments in prosthetic arm systems","volume":"8","author":"Vujaklija","year":"2016","journal-title":"Orthop. Res. Rev."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"643","DOI":"10.1682\/JRRD.2010.09.0177","article-title":"Electromyogram pattern recognition for control of powered upper-limb prostheses: State of the art and challenges for clinical use","volume":"48","author":"Scheme","year":"2011","journal-title":"J. Rehabil. Res. Dev."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Wurth, S.M., and Hargrove, L.J. (2014). A real-time comparison between direct control, sequential pattern recognition control and simultaneous pattern recognition control using a Fitts\u2019 law style assessment procedure. J. NeuroEng. Rehabil.","DOI":"10.1186\/1743-0003-11-91"},{"key":"ref_6","unstructured":"Zhang, W., White, M., Zahabi, M., Winslow, A.T., Zhang, F., Huang, H., and Kaber, D. (2016, January 9\u201312). Cognitive workload in conventional direct control vs. pattern recognition control of an upper-limb prosthesis. Proceedings of the 2016 IEEE International Conference on Systems, Man, and Cybernetics (SMC), Budapest, Hungary."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1109\/MSP.2012.2203480","article-title":"Myoelectric Control of Artificial Limbs\u2014Is There a Need to Change Focus? [In the Spotlight]","volume":"29","author":"Jiang","year":"2012","journal-title":"IEEE Signal Process. Mag."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1250","DOI":"10.1109\/TBME.2012.2232293","article-title":"Classification of Simultaneous Movements Using Surface EMG Pattern Recognition","volume":"60","author":"Young","year":"2013","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"756","DOI":"10.1109\/TNSRE.2014.2305097","article-title":"Real-Time and Simultaneous Control of Artificial Limbs Based on Pattern Recognition Algorithms","volume":"22","author":"Hkansson","year":"2014","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.1109\/TBME.2008.2007967","article-title":"Extracting Simultaneous and Proportional Neural Control Information for Multiple-DOF Prostheses From the Surface Electromyographic Signal","volume":"56","author":"Jiang","year":"2009","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1186\/1743-0003-9-42","article-title":"EMG-based simultaneous and proportional estimation of wrist\/hand kinematics in uni-lateral trans-radial amputees","volume":"9","author":"Jiang","year":"2012","journal-title":"J. NeuroEng. Rehabil."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1109\/TNSRE.2011.2178039","article-title":"Simultaneous and Proportional Estimation of Hand Kinematics From EMG During Mirrored Movements at Multiple Degrees-of-Freedom","volume":"20","author":"Muceli","year":"2012","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1016\/j.bspc.2014.03.006","article-title":"Real-time, simultaneous myoelectric control using visual target-based training paradigm","volume":"13","author":"Ameri","year":"2014","journal-title":"Biomed. Signal Process. Control"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"eaat3630","DOI":"10.1126\/scirobotics.aat3630","article-title":"Simultaneous control of multiple functions of bionic hand prostheses: Performance and robustness in end users","volume":"3","author":"Hahne","year":"2018","journal-title":"Sci. Robot."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1186\/s12984-018-0363-1","article-title":"Online mapping of EMG signals into kinematics by autoencoding","volume":"15","author":"Vujaklija","year":"2018","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1109\/TNSRE.2013.2287383","article-title":"Is Accurate Mapping of EMG Signals on Kinematics Needed for Precise Online Myoelectric Control?","volume":"22","author":"Jiang","year":"2014","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"4437","DOI":"10.1038\/s41598-017-04255-x","article-title":"User adaptation in Myoelectric Man-Machine Interfaces","volume":"7","author":"Hahne","year":"2017","journal-title":"Sci. Rep."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"2537","DOI":"10.1109\/TBME.2011.2159216","article-title":"The Effects of Electrode Size and Orientation on the Sensitivity of Myoelectric Pattern Recognition Systems to Electrode Shift","volume":"58","author":"Young","year":"2011","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"908","DOI":"10.1016\/j.jelekin.2012.04.009","article-title":"The Effect of Perspiration on the sEMG Amplitude and Power Spectrum","volume":"22","author":"Damecour","year":"2012","journal-title":"J. Electromyography Kinesiol."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1109\/TNSRE.2014.2305111","article-title":"The extraction of neural information from the surface EMG for the control of upper-limb prostheses: Emerging avenues and challenges","volume":"22","author":"Farina","year":"2014","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"906","DOI":"10.1299\/jsmec.43.906","article-title":"On-line Learning Based Electromyogram to Forearm Motion Classifier with Motor Skill Evaluation","volume":"43","author":"Nishikawa","year":"2000","journal-title":"JSME Int. J. Ser. C"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Kato, R., Yokoi, H., and Arai, T. (2006, January 9\u201315). Real-time Learning Method for Adaptable Motion-Discrimination using Surface EMG Signal. Proceedings of the 2006 IEEE\/RSJ International Conference on Intelligent Robots and Systems, Beijing, China.","DOI":"10.1109\/IROS.2006.282492"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1109\/TNSRE.2009.2023282","article-title":"Adaptive Pattern Recognition of Myoelectric Signals: Exploration of Conceptual Framework and Practical Algorithms","volume":"17","author":"Sensinger","year":"2009","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1186\/1743-0003-10-44","article-title":"Application of a self-enhancing classification method to electromyography pattern recognition for multifunctional prosthesis control","volume":"10","author":"Chen","year":"2013","journal-title":"J. NeuroEng. Rehabil."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"961","DOI":"10.1109\/TNSRE.2015.2492619","article-title":"Improving the Robustness of Myoelectric Pattern Recognition for Upper Limb Prostheses by Covariate Shift Adaptation","volume":"24","author":"Vidovic","year":"2016","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1109\/TNSRE.2016.2562180","article-title":"Cascaded Adaptation Framework for Fast Calibration of Myoelectric Control","volume":"25","author":"Zhu","year":"2017","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"956","DOI":"10.1109\/TNSRE.2019.2907200","article-title":"Counteracting Electrode Shifts in Upper-Limb Prosthesis Control via Transfer Learning","volume":"27","author":"Prahm","year":"2019","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"8","DOI":"10.3389\/fnbot.2014.00008","article-title":"Stable myoelectric control of a hand prosthesis using non-linear incremental learning","volume":"8","author":"Gijsberts","year":"2014","journal-title":"Front. Neurorobot."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"618","DOI":"10.1109\/TNSRE.2015.2401134","article-title":"Concurrent Adaptation of Human and Machine Improves Simultaneous and Proportional Myoelectric Control","volume":"23","author":"Hahne","year":"2015","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"026006","DOI":"10.1088\/1741-2552\/aa87cf","article-title":"Model and experiments to optimize co-adaptation in a simplified myoelectric control system","volume":"15","author":"Couraud","year":"2018","journal-title":"J. Neural Eng."},{"key":"ref_31","unstructured":"Astrom, K.J.K.J., and Wittenmark, B. (2008). Adaptive Control, Dover Publications."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1016\/0005-1098(81)90070-4","article-title":"Implementation of self-tuning regulators with variable forgetting factors","volume":"17","author":"Fortescue","year":"1981","journal-title":"Automatica"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1016\/S1474-6670(17)61051-6","article-title":"Tracking of Slowly Varying Parameters by Directional Forgetting","volume":"17","year":"1984","journal-title":"IFAC Proc. Vol."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1109\/TNSRE.2013.2278411","article-title":"Intuitive, Online, Simultaneous, and Proportional Myoelectric Control Over Two Degrees-of-Freedom in Upper Limb Amputees","volume":"22","author":"Jiang","year":"2014","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"026017","DOI":"10.1088\/1741-2552\/aa9666","article-title":"Robust extraction of basis functions for simultaneous and proportional myoelectric control via sparse non-negative matrix factorization","volume":"15","author":"Lin","year":"2018","journal-title":"J. Neural Eng."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1007\/s11517-014-1215-1","article-title":"Adaptive common average filtering for myocontrol applications","volume":"53","author":"Rehbaum","year":"2015","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S1050-6411(01)00033-5","article-title":"Sampling, noise-reduction and amplitude estimation issues in surface electromyography","volume":"12","author":"Clancy","year":"2002","journal-title":"J. Electromyogr. Kinesiol."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"1725","DOI":"10.1016\/S0005-1098(00)00093-5","article-title":"A Directional Forgetting Algorithm Based on the Decomposition of the Information Matrix","volume":"36","author":"Cao","year":"2000","journal-title":"Automatica"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1080\/00222895.1989.10735486","article-title":"A note on the information-theoretic basis of Fitts\u2019 law","volume":"21","author":"MacKenzie","year":"1989","journal-title":"J. Motor Behav."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1080\/01621459.1974.10482955","article-title":"Robust Tests for the Equality of Variances","volume":"69","author":"Brown","year":"1974","journal-title":"J. Am. Stat. Assoc."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/9\/2203\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T12:51:27Z","timestamp":1760187087000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/9\/2203"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,5,13]]},"references-count":40,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2019,5]]}},"alternative-id":["s19092203"],"URL":"https:\/\/doi.org\/10.3390\/s19092203","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,5,13]]}}}