{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,6]],"date-time":"2026-09-06T04:02:18Z","timestamp":1788667338777,"version":"build-2803163510"},"reference-count":49,"publisher":"MDPI AG","issue":"10","license":[{"start":{"date-parts":[[2019,5,16]],"date-time":"2019-05-16T00:00:00Z","timestamp":1557964800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100010663","name":"H2020 European Research Council","doi-asserted-by":"publisher","award":["ADG669354 CyberCar"],"award-info":[{"award-number":["ADG669354 CyberCar"]}],"id":[{"id":"10.13039\/100010663","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Nanostructured materials have attracted considerable interest over the last few decades to enhance sensing capabilities thanks to their unique properties and large surface area. In particular, noble metal nanostructures offer several advantages including high stability, non-toxicity and excellent electrochemical behaviour. However, in recent years the great expansion of point-of-care (POC) and wearable systems and the attempt to perform measurements in tiny spaces have also risen the need of increasing sensors miniaturization. Fast constant potential electrodeposition techniques have been proven to be an efficient way to obtain conformal platinum and gold nanostructured layers on macro-electrodes. However, this technique is not effective on micro-electrodes. In this paper, we investigate an alternative one-step deposition technique of platinum nanoflowers on micro-electrodes by linear sweep voltammetry (LSV). The effective deposition of platinum nanoflowers with similar properties to the ones deposited on macro-electrodes is confirmed by morphological analysis and by the similar roughness factor (~200) and capacitance (~18    \u03bc   F\/mm     2    ). The electrochemical behaviour of the nanostructured layer is then tested in an solid-contact (SC)     L  i +     -selective micro-electrode and compared to the case of macro-electrodes. The sensor offers Nernstian calibration with same response time (~15 s) and a one-order of magnitude smaller limit of detection (LOD) (    2.6 \u00d7  10  \u2212 6      ) with respect to the macro-ion-selective sensors (ISE). Finally, sensor reversibility and stability in both wet and dry conditions is proven.<\/jats:p>","DOI":"10.3390\/s19102260","type":"journal-article","created":{"date-parts":[[2019,5,16]],"date-time":"2019-05-16T11:21:22Z","timestamp":1558005682000},"page":"2260","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Fast Procedures for the Electrodeposition of Platinum Nanostructures on Miniaturized Electrodes for Improved Ion Sensing"],"prefix":"10.3390","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2725-468X","authenticated-orcid":false,"given":"Francesca","family":"Criscuolo","sequence":"first","affiliation":[{"name":"Laboratory of Integrated Systems, \u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne (EPFL), 1015 Lausanne, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Irene","family":"Taurino","sequence":"additional","affiliation":[{"name":"Laboratory of Integrated Systems, \u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne (EPFL), 1015 Lausanne, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Van","family":"Dam","sequence":"additional","affiliation":[{"name":"Holst Centre, Interuniversity Microelectronics Centre (IMEC), 5656 AE Eindhoven, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3599-8515","authenticated-orcid":false,"given":"Francky","family":"Catthoor","sequence":"additional","affiliation":[{"name":"Department ESAT, Interuniversity Microelectronics Centre (IMEC), 3001 Leuven, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcel","family":"Zevenbergen","sequence":"additional","affiliation":[{"name":"Holst Centre, Interuniversity Microelectronics Centre (IMEC), 5656 AE Eindhoven, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sandro","family":"Carrara","sequence":"additional","affiliation":[{"name":"Laboratory of Integrated Systems, \u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne (EPFL), 1015 Lausanne, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giovanni","family":"De Micheli","sequence":"additional","affiliation":[{"name":"Laboratory of Integrated Systems, \u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne (EPFL), 1015 Lausanne, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2019,5,16]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1021\/acs.chemrev.8b00172","article-title":"Functional Nanomaterials and Nanostructures Enhancing Electrochemical Biosensors and Lab-on-a-Chip Performances: Recent Progress, Applications, and Future Perspective","volume":"119","author":"Wongkaew","year":"2019","journal-title":"Chem. Rev."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1021\/ac5039863","article-title":"Electrochemical Sensors and Biosensors Based on Nanomaterials and Nanostructures","volume":"87","author":"Zhu","year":"2015","journal-title":"Anal. Chem."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3389\/fchem.2014.00063","article-title":"Nanomaterials for biosensing applications: A review","volume":"2","author":"Holzinger","year":"2014","journal-title":"Front. Chem."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1016\/j.trac.2015.11.004","article-title":"Rational design of all-solid-state ion-selective electrodes and reference electrodes","volume":"76","author":"Hu","year":"2016","journal-title":"Trends Anal. Chem."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"8391","DOI":"10.1021\/acs.chemmater.8b04152","article-title":"Engineered Noble-Metal Nanostructures for in Vitro Diagnostics","volume":"30","author":"Xi","year":"2018","journal-title":"Chem. Mater."},{"key":"ref_6","first-page":"70","article-title":"Miniaturization for Point-of-Care Analysis: Platform Technology for Almost Every Biomedical Assay","volume":"23","author":"Schumacher","year":"2012","journal-title":"J. Int. Fed. Clin. Chem. Lab. Med."},{"key":"ref_7","unstructured":"Bakker, E., and Xie, X. (2014). Shrinking Ion-Selective Sensors for Success. Anal. Sci., 20."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1016\/j.tibtech.2014.04.005","article-title":"Non-invasive wearable electrochemical sensors: A review","volume":"32","author":"Bandodkar","year":"2014","journal-title":"Trends Biotechnol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1021\/acssensors.6b00250","article-title":"Wearable Chemical Sensors: Present Challenges and Future Prospects","volume":"1","author":"Bandodkar","year":"2016","journal-title":"ACS Sens."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1002\/elan.201200349","article-title":"Wearable Electrochemical Sensors and Biosensors: A Review","volume":"25","author":"Windmiller","year":"2013","journal-title":"Electroanalysis"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1038\/s41928-018-0043-y","article-title":"Wearable sweat sensors","volume":"1","author":"Bariya","year":"2018","journal-title":"Nat. Electron."},{"key":"ref_12","first-page":"3825","article-title":"A novel electrochemical sensor for non-invasive monitoring of lithium levels in mood disorders","volume":"2018","author":"Criscuolo","year":"2018","journal-title":"Eng. Med. Biol. Soc."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1038\/nature16521","article-title":"Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis","volume":"529","author":"Gao","year":"2016","journal-title":"Nature"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"15890","DOI":"10.1038\/s41598-018-33565-x","article-title":"Wearable Sensor System for Detection of Lactate in Sweat","volume":"8","author":"Currano","year":"2018","journal-title":"Sci. Rep."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"4625","DOI":"10.1073\/pnas.1701740114","article-title":"Autonomous sweat extraction and analysis applied to cystic fibrosis and glucose monitoring using a fully integrated wearable platform","volume":"114","author":"Emaminejad","year":"2017","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1039\/b9ay00184k","article-title":"A wearable electrochemical sensor for the real-time measurement of sweat sodium concentration","volume":"2","author":"Schazmann","year":"2010","journal-title":"Anal. Methods"},{"key":"ref_17","first-page":"730","article-title":"A wearable multisensing patch for continuous sweat monitoring","volume":"93","author":"Crewther","year":"2017","journal-title":"Biosens. Bioelectron."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"7216","DOI":"10.1021\/acsnano.6b04005","article-title":"A Wearable Electrochemical Platform for Noninvasive Simultaneous Monitoring of Ca2+ and pH","volume":"10","author":"Nyein","year":"2016","journal-title":"ACS Nano"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1011","DOI":"10.1021\/acssensors.6b00356","article-title":"Noninvasive Alcohol Monitoring Using a Wearable Tattoo-Based Iontophoretic-Biosensing System","volume":"1","author":"Kim","year":"2016","journal-title":"ACS Sens."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"434","DOI":"10.1016\/j.snb.2013.12.002","article-title":"Miniaturized water quality monitoring pH and conductivity sensors","volume":"193","author":"Banna","year":"2014","journal-title":"Sens. Actuators B Chem."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"6731","DOI":"10.1021\/ac800823f","article-title":"Elimination of undesirable water layers in solid contact polymeric ion-selective electrodes","volume":"80","author":"Veder","year":"2008","journal-title":"Anal. Chem."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1007\/s10008-008-0608-1","article-title":"Quality control criteria for solid-contact, solvent polymeric membrane ion-selective electrodes","volume":"13","author":"Lindner","year":"2009","journal-title":"J. Solid State Electrochem."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"65","DOI":"10.4028\/www.scientific.net\/AST.77.65","article-title":"Recent Progress in Disposable Ion-Selective Sensors for Environmental Applications","volume":"77","author":"Matzeu","year":"2012","journal-title":"Adv. Sci. Technol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"10224","DOI":"10.1021\/acs.analchem.7b01560","article-title":"Wearable Sweatband Sensor Platform Based on Gold Nanodendrite Array as Efficient Solid Contact of Ion-Selective Electrode","volume":"89","author":"Wang","year":"2017","journal-title":"Anal. Chem."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.trac.2013.06.009","article-title":"Trends in Analytical Chemistry Applications of nanomaterials in potentiometric sensors","volume":"51","author":"Yin","year":"2013","journal-title":"Trends Anal. Chem."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1316","DOI":"10.1021\/ac071156l","article-title":"Ion-selective electrodes using carbon nanotubes as ion-to-electron transducers","volume":"80","author":"Crespo","year":"2008","journal-title":"Anal. Chem."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"2698","DOI":"10.1039\/c3an00313b","article-title":"A potassium sensor based on non-covalent functionalization of multi-walled carbon nanotubes","volume":"138","author":"Parra","year":"2013","journal-title":"Analyst"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"35169","DOI":"10.1021\/acsami.7b07346","article-title":"Carbon Nanotube-Based Ion Selective Sensors for Wearable Applications","volume":"9","author":"Roy","year":"2017","journal-title":"ACS Appl. Mater. Interfaces"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1016\/j.aca.2014.10.033","article-title":"A simple approach for fabricating solid-contact ion-selective electrodes using nanomaterials as transducers","volume":"853","author":"Liang","year":"2015","journal-title":"Anal. Chim. Acta"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.aca.2015.03.038","article-title":"An all-solid-state polymeric membrane Pb2+-selective electrode with bimodal pore C60 as solid contact","volume":"876","author":"Li","year":"2015","journal-title":"Anal. Chim. Acta"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1039\/b719759d","article-title":"Fullerene-based electrochemical buffer layer for ion-selective electrodes","volume":"133","author":"Fouskaki","year":"2008","journal-title":"Analyst"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"618","DOI":"10.1039\/C1AN15705A","article-title":"All-solid-state potassium-selective electrode using graphene as the solid contact","volume":"137","author":"Li","year":"2012","journal-title":"Analyst"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"22570","DOI":"10.1021\/jp306234u","article-title":"Reduced graphene oxide films as solid transducers in potentiometric all-solid-state ion-selective electrodes","volume":"116","author":"Riu","year":"2012","journal-title":"J. Phys. Chem. C"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"1529","DOI":"10.1016\/j.elecom.2011.10.018","article-title":"Electrochemistry Communications Development of an all-solid-state potassium ion-selective electrode using graphene as the solid-contact transducer","volume":"13","author":"Ping","year":"2011","journal-title":"Electrochem. Commun."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"3473","DOI":"10.1021\/ac203480z","article-title":"Application of electrochemically reduced graphene oxide on screen-printed ion-selective electrode","volume":"84","author":"Ping","year":"2012","journal-title":"Anal. Chem."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"624","DOI":"10.1016\/j.snb.2015.10.054","article-title":"Few-layer graphene and polyaniline composite as ion-to-electron transducer in silicone rubber solid-contact ion-selective electrodes","volume":"224","author":"Boeva","year":"2015","journal-title":"Sens. Actuators B"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"2773","DOI":"10.1080\/00032719.2015.1045594","article-title":"Carbon-Supported Platinum Nanoparticle Solid-State Ion Selective Electrodes for the Determination of Potassium","volume":"48","author":"Cabaj","year":"2015","journal-title":"Anal. Lett."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"7771","DOI":"10.1021\/ac3011507","article-title":"Advantages and limitations of reference electrodes with an ionic liquid junction and three-dimensionally ordered macroporous carbon as solid contact","volume":"84","author":"Zhang","year":"2012","journal-title":"Anal. Chem."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"4621","DOI":"10.1021\/ac070132b","article-title":"Ion-selective electrodes with three-dimensionally ordered macroporous carbon as the solid contact","volume":"79","author":"Lai","year":"2007","journal-title":"Anal. Chem."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/j.elecom.2014.10.014","article-title":"Using sp2-C dominant porous carbon sub-micrometer spheres as solid transducers in ion-selective electrodes","volume":"50","author":"Ye","year":"2015","journal-title":"Electrochem. Commun."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"1007","DOI":"10.1016\/j.electacta.2016.11.069","article-title":"Simple and Efficient Synthesis of Gold Nanoclusters and Their Performance as Solid Contact of Ion Selective Electrode","volume":"222","author":"Xu","year":"2016","journal-title":"Electrochim. Acta"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"11038","DOI":"10.1021\/ac5029209","article-title":"All-solid-state polymeric membrane ion-selective miniaturized electrodes based on a nanoporous gold film as solid contact","volume":"86","author":"Yin","year":"2014","journal-title":"Anal. Chem."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"1986","DOI":"10.1016\/j.talanta.2011.07.049","article-title":"Gold nanoparticles solid contact for ion-selective electrodes of highly stable potential readings","volume":"85","author":"Jaworska","year":"2011","journal-title":"Talanta"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1016\/j.electacta.2015.01.143","article-title":"Solid-Contact Ion-Selective Electrodes (ISEs) based on Ligand Functionalised Gold Nanoparticles","volume":"159","author":"Matzeu","year":"2015","journal-title":"Electrochim. Acta"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"10255","DOI":"10.1021\/ac402885y","article-title":"Potentiometric sensors with carbon black supporting platinum nanoparticles","volume":"85","author":"Cabaj","year":"2013","journal-title":"Anal. Chem."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"15277","DOI":"10.1038\/srep15277","article-title":"Fast synthesis of platinum nanopetals and nanospheres for highly-sensitive non-enzymatic detection of glucose and selective sensing of ions","volume":"5","author":"Taurino","year":"2015","journal-title":"Sci. Rep."},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Criscuolo, F., Lobello, L., Taurino, I., Demarchi, D., Carrara, S., and Micheli, G.D. (2018, January 28\u201331). Mixed gold and platinum nanostructured layers for all-solid-state ion sensors. Proceedings of the IEEE Sensors Conference, New Delhi, India.","DOI":"10.1109\/ICSENS.2018.8630299"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.aca.2018.04.062","article-title":"Highly-stable Li + ion-selective electrode based on noble metal nanostructures as solid-contacts","volume":"1027","author":"Criscuolo","year":"2018","journal-title":"Anal. Chim. Acta"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"4932","DOI":"10.1021\/ac990497z","article-title":"Potential Stability of All-Solid-State Ion-Selective Electrodes Using Conducting Polymers as Ion-to-Electron Transducers","volume":"71","author":"Bobacka","year":"1999","journal-title":"Anal. Chem."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/10\/2260\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T12:52:20Z","timestamp":1760187140000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/10\/2260"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,5,16]]},"references-count":49,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2019,5]]}},"alternative-id":["s19102260"],"URL":"https:\/\/doi.org\/10.3390\/s19102260","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,5,16]]}}}