{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T22:18:27Z","timestamp":1767651507588,"version":"build-2065373602"},"reference-count":20,"publisher":"MDPI AG","issue":"10","license":[{"start":{"date-parts":[[2019,5,18]],"date-time":"2019-05-18T00:00:00Z","timestamp":1558137600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education","award":["NRF-2016R1D1A1B03934950"],"award-info":[{"award-number":["NRF-2016R1D1A1B03934950"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The enumeration of cellular proliferation by covering from hemocytometer to flow cytometer is an important procedure in the study of cancer development. For example, hemocytometer has been popularly employed to perform manual cell counting. It is easily achieved at a low-cost, however, manual cell counting is labor-intensive and prone to error for a large number of cells. On the other hand, flow cytometer is a highly sophisticated instrument in biomedical and clinical research fields. It provides detailed physical parameters of fluorescently labeled single cells or micro-sized particles depending on the fluorescence characteristics of the target sample. Generally, optical setup to detect fluorescence uses a laser, dichroic filter, and photomultiplier tube as a light source, optical filter, and photodetector, respectively. These components are assembled to set up an instrument to measure the amount of scattering light from the target particle; however, these components are costly, bulky, and have limitations in selecting diverse fluorescence dyes. Moreover, they require multiple refined and expensive modules such as cooling or pumping systems. Thus, alternative cost-effective components have been intensively developed. In this study, a low-cost and miniaturized fluorescence detection system is proposed, i.e., costing less than 100 US dollars, which is customizable by a 3D printer and light source\/filter\/sensor operating at a specific wavelength using a light-emitting diode with a photodiode, which can be freely replaceable. The fluorescence detection system can quantify multi-directional scattering lights simultaneously from the fluorescently labeled cervical cancer cells. Linear regression was applied to the acquired fluorescence intensities, and excellent linear correlations (R2 &gt; 0.9) were observed. In addition, the enumeration of the cells using hemocytometer to determine its performance accuracy was analyzed by Student\u2019s t-test, and no statistically significant difference was found. Therefore, different cell concentrations are reversely calculated, and the system can provide a rapid and cost-effective alternative to commercial hemocytometer for live cell or microparticle counting.<\/jats:p>","DOI":"10.3390\/s19102301","type":"journal-article","created":{"date-parts":[[2019,5,20]],"date-time":"2019-05-20T11:05:07Z","timestamp":1558350307000},"page":"2301","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["An Alternative Approach to Detecting Cancer Cells by Multi-Directional Fluorescence Detection System Using Cost-Effective LED and Photodiode"],"prefix":"10.3390","volume":"19","author":[{"given":"Kyoungrae","family":"Cho","sequence":"first","affiliation":[{"name":"Department of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39253, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jeong-hyeok","family":"Seo","sequence":"additional","affiliation":[{"name":"Department of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39253, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gyeongyong","family":"Heo","sequence":"additional","affiliation":[{"name":"Department of Electronic Engineering, Dong-eui University, Busan 47340, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7298-4147","authenticated-orcid":false,"given":"Se-woon","family":"Choe","sequence":"additional","affiliation":[{"name":"Department of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39253, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2019,5,18]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Absher, M. (1973). Hemocytometer counting. Tissue Culture, Elsevier.","DOI":"10.1016\/B978-0-12-427150-0.50098-X"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"2438","DOI":"10.1038\/s41598-018-20913-0","article-title":"Poisson statistics-mediated particle\/cell counting in microwell arrays","volume":"8","author":"Ahrberg","year":"2018","journal-title":"Sci. Rep."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"739","DOI":"10.1126\/science.aad6770","article-title":"Flow cytometry strikes gold","volume":"350","author":"Robinson","year":"2015","journal-title":"Science"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"163","DOI":"10.3109\/07388551.2015.1128876","article-title":"Flow cytometry: Basic principles and applications","volume":"37","author":"Adan","year":"2017","journal-title":"Crit. Rev. Biotechnol."},{"key":"ref_5","unstructured":"Kaushik, S. (2019, May 18). Magnetic Flow Cytometry for Point-of-Care Applications. Available online: https:\/\/cloudfront.escholarship.org\/dist\/prd\/content\/qt45b287bv\/qt45b287bv.pdf?t=ony7gq."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1111\/jth.13514","article-title":"Standardization of microparticle enumeration across different flow cytometry platforms: Results of a multicenter collaborative workshop","volume":"15","author":"Cointe","year":"2017","journal-title":"J. Thromb. Haemost."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1007\/s00284-017-1370-3","article-title":"Cost-Effective Live Cell Density Determination of Liquid Cultured Microorganisms","volume":"75","author":"Kutschera","year":"2018","journal-title":"Curr. Microbiol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1088\/0957-0233\/13\/3\/306","article-title":"Quantification of scattering corrections to the Beer-Lambert law for transmittance measurements in turbid media","volume":"13","author":"Wind","year":"2002","journal-title":"Meas. Sci. Technol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/j.cvsm.2011.09.012","article-title":"Principles and Applications of Flow Cytometry and Cell Sorting in Companion Animal Medicine","volume":"42","author":"Wilkerson","year":"2012","journal-title":"Vet. Clin. N. Am. Small Anim. Pract."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"25530","DOI":"10.3402\/jev.v4.25530","article-title":"Simplified protocol for flow cytometry analysis of fluorescently labeled exosomes and microvesicles using dedicated flow cytometer","volume":"4","author":"Pospichalova","year":"2015","journal-title":"J. Extracell. Vesicles"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1155","DOI":"10.1016\/j.talanta.2009.01.033","article-title":"A low-cost light-emitting diode induced fluorescence detector for capillary electrophoresis based on an orthogonal optical arrangement","volume":"78","author":"Yang","year":"2009","journal-title":"Talanta"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1146\/annurev-anchem-071213-020059","article-title":"Light-Emitting Diodes for Analytical Chemistry","volume":"7","author":"Macka","year":"2014","journal-title":"Annu. Rev. Anal. Chem."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1016\/j.talanta.2017.07.022","article-title":"A facile and high sensitive micro fluorimeter based on light emitting diode and photodiode","volume":"175","author":"Geng","year":"2017","journal-title":"Talanta"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.transci.2015.10.008","article-title":"Tips and tricks for flow cytometry-based analysis and counting of microparticles","volume":"53","author":"Poncelet","year":"2015","journal-title":"Transfus. Apher. Sci."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"2839","DOI":"10.1039\/C7LC00706J","article-title":"3D-printed smartphone-based point of care tool for fluorescence- and magnetophoresis-based cytometry","volume":"17","author":"Knowlton","year":"2017","journal-title":"Lab Chip"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1007\/s12668-016-0359-x","article-title":"Improved Recordings of the Optical Intrinsic Signals in the Neonatal Rat Barrel Cortex","volume":"7","author":"Sintsov","year":"2017","journal-title":"BioNanoScience"},{"key":"ref_17","first-page":"83","article-title":"Fluorescence Activated Cell Sorting (FACS): An Advanced Cell Sorting Technique","volume":"2","author":"Ammara","year":"2017","journal-title":"PSM Biol. Res."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1016\/j.nima.2015.08.003","article-title":"Muon tracking system with Silicon Photomultipliers","volume":"799","author":"Arneodo","year":"2015","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1080\/24699322.2017.1379158","article-title":"Combinational light emitting diode-high frequency focused ultrasound treatment for HeLa cell","volume":"22","author":"Choe","year":"2017","journal-title":"Comput. Assist. Surg."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1177\/135965350400900309","article-title":"Simplified volumetric flow cytometry allows feasible and accurate determination of CD4 T lymphocytes in immunodeficient patients worldwide","volume":"9","author":"Cassens","year":"2004","journal-title":"Antivir. Ther."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/10\/2301\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T12:53:23Z","timestamp":1760187203000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/10\/2301"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,5,18]]},"references-count":20,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2019,5]]}},"alternative-id":["s19102301"],"URL":"https:\/\/doi.org\/10.3390\/s19102301","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2019,5,18]]}}}